A Study on the Grounding Resistance Effects of Lightning Arrester for Lightning Stroke Protection in Electric Distribution Systems (배전계통에서 낙뢰보호용 피뢰기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.107-114
    • /
    • 2010
  • Lightning is the discharging of high-voltage charged cells within clouds to earth other or to the earth. Lightning protection grounding is essential for the protection of buildings, distribution lines, and electrical equipment from lightning surges. Equipment grounding is for the purpose of controlling the voltage to earth within predictable limits. This paper investigates the effects of lightning arrester grounding resistance by analysing the neutral to earth voltages and arrester break down voltages when the lightning strike hits the distribution line. The case study was simulated numerically and graphically through the use of the EDSA software program.

A Study on Effect of Neutral Resistance Deterioration to 154㎸ Power Capacitances (154 ㎸ SC Neutral Resistor 절연이 콘덴서 뱅크에 미치는 영향)

  • Jeon, Sang-Dong;Kim, Gi-Il;Jeong, Kyu-Won;Ryu, Hee-Young;Lee, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.345-346
    • /
    • 2008
  • 최근에 콘덴서 뱅크에서 자주 일어나는 고장의 유형은 콘덴서의 내부절연파괴, 리액터의 소손이 주를 이루고 있다. 그중에서 콘덴서 셀의 절연파괴가 수대에서 십 수대까지 동시에 발생하기도 한다. 이러한 현상의 대부분은 차단기의 투입 시 서지전압과 전류에 의해 서서히 진행 혹은 갑작스런 고장으로 진행되고 있다. 이중에서 저항기의 절연열화가 진행되면 차단기 투입 시 순간적인 절연파괴를 일으켜 급준파의 전류를 더 급준하게 만들면서 콘덴서나 리액터의 열화를 더욱 더 가중시키며 순간적으로 저항기의 역할을 못하게 되어 안정상태를 더욱 해치는 역할을 수행하게 된다. 이 논문에서는 콘덴서 뱅크와 중성점 저항기의 특성을 분석하고 중성점 저항기의 절연성능을 보강하여 전, 후의 서지전류 특성을 비교함으로써 실제 계통에서 중성점 저항기의 절연열화가 콘덴서 뱅크에 미치는 영향에 대해서 알아보고자 한다.

  • PDF

Modeling and Line Current Control of a Three Phase Voltage Source Inverter using an LCL filter in a Balanced Delta Circuit (LCL 필터를 사용하는 삼상 전압형 인버터의 모델링과 계통전류 제어)

  • Lee, Sang-In;Lee, Kui-Jun;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.18-20
    • /
    • 2007
  • 3상 계통 연계 형 인버터 시스템은 낮은 THD를 가지는 계통 전류를 공급해주기 위해 LCL 필터를 사용한다. LCL 필터를 사용하는 가장 큰 장점은 낮은 스위칭 주파수에서도 만족할 만한 수준의 THD를 가지는 계통 전류를 생성시킬 수 있다는 점이다. 반면에, 단점은 LCL필터를 포함하는 계통 연계 형 인버터 시스템의 전달함수에 하나의 공진 극점이 존재한다는 점이다. 이것은 계통 전류 제어 loop에서, 안정성 문제에 영향을 미친다. 정확한 제어를 위해서 시스템의 전달함수는 필수적이다. 여기서 중요한 점은 많은 저자들이 시뮬레이션과 실험을 할 때, 중성점이 없는 회로에서 행하지만 회로 해석을 할 때에는 중성점이 있는 회로에서 해석을 한다는 점이다. 그래서 우리는 등가 델타회로에서 LCL 필터를 포함한 전체 시스템의 수학적인 모델을 제안한다. 이 모델은 모든 인덕터와 커패시터의 기생 저항을 고려한다. 또한 이 논문은 계통 전류를 제어하기 위한 제어기의 해석적인 설계 절차를 포함한다. 제안한 수학적인 모델을 입증하기 위해, PSIM을 통한 시뮬레이션과 Simulink를 통한 시뮬레이션 결과를 비교하였다.

  • PDF

MOVEMENT OF ELECTRIC NEUTRAL POINT ON NON GROUNDED SYSTEM (비접지계통 중성점이동 현상 분석)

  • Lee, Jong-Hweon;Jeon, Myeong-Ryeal;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.28_29
    • /
    • 2009
  • 전력계통의 비접지 계통에 지락 고장이 발생하면 중성점 이동으로 고장이 발생하지 않은 건전상의 전위가 상승한다는 사실은 누구나 다 알고 있다. 이는 전기적으로 균형을 이루고 있는 계통에 지락 고장으로 상간 불균형이 초래되기 때문인데 보통 비접지 계통의 보호는 1상 지락 시는 고장전류가 거의 없기 때문에 영상 과전압을 이용한 한시 보호계전 방식으로, 2중 접지 시는 과전류 계전방식으로 보호 하고 있다. 그런데 고장전류가 없어 상대적으로 파급이 적을 것 같은 1상 지락고장 시 건전 상에 발생한 과전압이 또 다른 고장을 유발, 더 큰 고장으로 진전되어 많은 복구비용을 발생하게 하거나 예상치 못한 현상을 일으켜 고장원인을 분석하고 처리하는데 어려움을 초래하기도 한다. 본 논문은 발전소 비접지 계통에서 발생하는 중성점이동 현상에 대해서 논하고자 한다.

  • PDF

Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships (선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성)

  • Lee, Yun-Hyung;Ryu, Ki-Tak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.689-696
    • /
    • 2018
  • System grounding is applied to the neutral point of a power source to secure the from any abnormal voltage and/or grounding fault. System grounding, which is applied mainly in ships is an ungrounded and resistance grounded system. Vessels using the MV power system with 3.3kV, 6.6kV, and 11kV mainly adopt a high resistance grounding system among the resistance grounding systems. The ground fault accounts for 95% of all faults occurring in the electrical system and when a fault occurs, the line-to-ground voltage of the power system is increased excessively, which adversely affects the onboard insulation system. This study analyzed the variation characteristics of the line-to-ground voltage neutral point according to the degree of ground fault in a resistance ground system applied in vessels. For this purpose, the characteristics of the grounding system were first explained, and the modeling of the neutral point potential of the line-to-ground voltage of the resistance grounding system in the vessels was derived. Finally, this study examined how the line-to-ground voltage, line voltage, and neutral point change according to various variable environments through MATLAB simulations.

A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems (배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin;Lee, Kang-Soo;Choi, Sun-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.113-119
    • /
    • 2010
  • A safe grounding design is used for providing means to carry electric currents into the earth under fault conditions without exceeding any operating limits and for assuring that a person in the vicinity of grounded facilities is not exposed to danger of critical electrical shock. Transformer neutral point grounding is for the purpose of controlling the voltage to earth within tolerable limits under a line-to-ground fault. Transformer frame grounding is for the purpose of minimizing the hazardous potential within safety criteria appearing at the faulted equipment. ills paper deeply investigates the grounding resistance effects of distribution power transformers by analysing the neutral to eatth voltages and touch voltages when the fault occurs.

3-level 3-phase Bidirectional Transformerless Inverter with High Efficiency (고효율의 3-level 3-phase 무변압기형 양방향 인버터)

  • Jeong, Yeong-Seung;Jeong, Seo-Gwang;Noh, Jun-Taek;Shin, Ik-Du;Kwon, Bong-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.201-202
    • /
    • 2016
  • 본 논문에서는 고효율을 갖는 3-level 3-phase 무변압기형 양방향 인버터를 제안한다. 제안된 인버터는 두 개의 직류링크 커패시터를 통해 연결된 3-level dc-dc 컨버터와 T-type 인버터로 구성된다. 따라서 낮은 전압 스트레스를 가지며 스위칭 및 도통 손실이 줄어들고 변압기가 없어 높은 전력 밀도와 고효율을 달성한다. 스위칭에 의해 발생하는 직류링크 중성점 변화에 따른 출력 전압왜곡은 제안된 중성점 제어 알고리즘을 통해 직류링크 전압의 균형을 맞추어 최소화된다. 또한 T-type 인버터는 제안하는 제어 알고리즘을 통해 높은 품질의 계통전류를 출력한다. 본 논문에서는 제안된 인버터의 이론적 해석 및 시작품의 실험을 수행하여 타당성을 검증하였다.

  • PDF

Small-Signal Modeling and Control of Three-Phase Grid-Connected 3-Level Neutral-Point-Clamped Inverter with a LCL Filter (LCL 필터를 사용한 계통 연계형 3-레벨 인버터의 소신호 모델링 및 제어)

  • Jung, Hong-Ju;Ku, Nam-Joon;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.376-377
    • /
    • 2011
  • 본 논문에서는 LCL 필터를 사용한 계통 연계형 3-레벨 인버터의 소신호 등가모델을 유도하는 과정과 이 모델을 이용한 계통 전류 및 중성점 전류 제어기를 설계하는 내용을 소개한다. 소신호 등가모델은 평균화 과정, 변동과 선형화 과정을 통해 유도하였다. 특히, 중성점 전류 제어기 설계를 위한 DC 링크단의 소신호 모델은 새로운 스위칭 함수를 적용시킴으로써 유도하였다. 제안된 방식의 검증을 위하여 시뮬레이션을 실시하였고 또한, 소용량 프로토타입을 제작하여 실험 결과를 통해 본 논문에서 제안한 모델링 및 제어기설계의 타당성을 입증하였다.

  • PDF