• Title/Summary/Keyword: 중공 기둥

Search Result 64, Processing Time 0.03 seconds

Seismic Resistance of Cast-In-Place Concrete-Filled Hollow PC Columns (현장타설 콘크리트 채움 중공 PC기둥의 내진성능)

  • Lim, Woo-Young;Park, Hong-Gun;Oh, Jung-Keun;Kim, Chang-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.35-46
    • /
    • 2014
  • Two types of cast-in-place concrete-filled hollow PC (HPC1, HPC2) columns were developed to reduce lifting load of heavy-weight PC columns and to improve the structural integrity of joints. To form the hollow PC columns, a couple of prefabricated PC panels was used for HPC1, and special hoops were used for HPC2. Lateral pressure of wet concrete on PC faces was measured while placing the concrete inside the columns. To evaluate the seismic resistance, full scale specimens of two HPC columns and a conventional RC column were tested under combined axial compression and lateral cyclic loading. The test results showed that the structural performance of the proposed HPC columns such as intial stiffness, maximum strength, and displacement ductility was comparable to that of the conventional RC column, but the energy dissipation of HPC2 slightly decreased after rebar-buckling. However, all the test specimens satisfied the energy dissipation requirement specified in ACI 374.

Evaluation of Structural Performance the Hollow PC Column Joint Subjected to Cyclic Lateral Load (반복 횡하중을 받는 유공 PC 기둥 접합부의 구조성능 평가)

  • Seo, Soo-Yeon;Yoon, Seong-Joe;Lee, Woo-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.335-343
    • /
    • 2008
  • In order to improve the workability in erecting Precast Concrete (PC) members and enhance the seismic resistance capacity of the joints in PC moment frames, a new PC column and its construction process are introduced in this paper. This column is manufactured by centrifugal force in keeping the hollow tube inside; the hollow is little bit wide and the grout can be poured from top to bottom after erection at site so that more compact grouting is possible in horizontal joint. The repeated cyclic loading test for four full scaled specimens was conducted to evaluate the seismic resistance capacity of the joint designed by the proposed system. For the continuity of main reinforcements in column, two connecting methods are used in designing specimens; one is to use mechanical connector and other is lab splice. From the cyclic lateral loading test, it was found that the seismic capacity of the developed PC column joint is comparable to that of monolithic joint.

Failure Behavior of Hollow Circular RC Column According to the Spacing of Spirals (나선철근 간격에 따른 중공 원형 RC 기둥의 파괴거동)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.46-55
    • /
    • 2016
  • Three small scale hollow circular reinforced concrete columns(4.5 aspect ratio) were tested under cyclic lateral load with constant axial load. Diameter of section is 400 mm, hollow diameter is 200 mm. The selected test variable are transverse steel ratio. Volumetric ratio of spirals of all the columns is 0.302~0.604% in the plastic hinge region. It corresponds to 45.9~91.8% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The final objectives of this study are to provide quantitative reference data and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, steel fracture, etc. In this paper, describes mainly failure behavior, strength degradation behaviour, displacement ductility of circular reinforced concrete bridge columns with respect to test variables.

An Experimental Study on the Behaviours of Hollow CFT Column Subjected to Axial Load (중공 콘크리트충전 각형강관 기둥의 거동에 관한 연구 (I. 중심 압축실험))

  • Kim, Cheol-Hwan;Kim, Jong-Kil
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.69-76
    • /
    • 2006
  • Concrete Filled Steel Tube (CFT) system is advantageous because it increases the load-carrying capacity without increasing the size of column. However CFT system has many benefits, it is not applied to field generally because of its heavyweight and difficulty of concrete filling method. As a solution to these problems, we proposed concrete filled steel tube column with hollow made by factory-manufactured PC method. The hollow concrete filled steel tube system is expected to obtain the high strength and high capacity of deformation despite it is a lightweight. This study deals with mechanical properties, strength and deformation, of hollow concrete filled steel tube subjected to axial load. 9 specimens were tested to examine mechanical properties closely, and the following results were obtained: All specimens basically showed higher initial rigidity and maximum strength with increased concrete filling rate. And most specimens showed almost linear behavior until around 80% of maximum strength regardless of filling rate, it is estimated that the elastic range is up to a half of the maximum strength which is the yield strength level.

  • PDF

Initial Shear Strength of Hollow Sectional Columns Subjected to Lateral Force (횡하중을 받는 RC 중공단면 기둥의 초기전단강도)

  • Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.1-14
    • /
    • 2009
  • Ductility-based seismic design is strongly required for the rational and cost-effective design of RC piers, and a reliable evaluation of shear strength is indispensable for its success. Unlike the flexural behavior of RC columns, shear behavior is highly complex, due to its many effects such as size, aspect ratio, axial force, ductility and so on. To address this, many design and empirical equations have been proposed considering these effects. However, these equations show significant differences in their evaluation of the initial shear strength, and the reduction in strength with the increase of ductility. In this study, the characteristics of initial shear strength of hollow sectional columns were investigated using experiments with the parameters of aspect ratios, void ratios, web area ratios and load patterns. The test results were analyzed through a comparison with the values predicted by empirical equations. On the basis of the mechanical characteristics and test results, a new empirical equation was proposed, and its validity was assessed.

Ductility of Circular Hollow Reinforced Concrete Piers Internally Confined by a Steel Tube (내부 강관 보강 원형 R.C 기둥의 연성 거동 특성)

  • Han, Taek-Hee;Han, Sang-Yun;Han, Keum-Ho;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.2 s.9
    • /
    • pp.127-137
    • /
    • 2003
  • In locations where the cost of concrete is relatively high, or in situations where the weight of concrete members is to be kept to a minimum, it may be economical to use hollow R.C. members. The ductility of circular hollow R.C. columns with one layer of longitudinal and spiral reinforcement placed near the outside face of the section and the steel tube placed on the inside face of the section is investigated. Such hollow sections are confined through the wall thickness since the steel tube is placed. In this study, moment-curvature analyses are conducted with Mander's confined concrete stress-strain relationship. The variables influenced on the ultimate strain is the ratio and yield strength of confining reinforcement and the compression strength for confined concrete. From this ultimate strain - the transverse reinforcement ratio relationship, the transverse reinforcement ratio for circular hollow reinforced columns with confinement is proposed. The proposed transverse reinforcement ratio is confirmed by experimental results.

Initial shear strength of RC hollow sectional columns (RC 중공단면 기둥의 초기전단강도 특성)

  • Sun, Chang-Ho;Kim, Ick-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.449-450
    • /
    • 2009
  • In this study, the characteristics of initial shear strength of hollow sectional columns were investigated by experiments with parameters of the aspect ratios, void ratios, web area ratios and load patterns. The test results were analyzed with comparison of the values expected by the empirical equations. The empirical equation was newly proposed on the basis of mechanical characteristics and test results, and its validity was evaluated.

  • PDF

Characteristics of the shear behavior of RC rectangular sectional columns and initial shear strength considering the ratio of longitudinal bars (RC 사각단면 기둥의 전단거동특성과 축방향철근비를 고려한 초기전단강도)

  • Lee, Jong-Seok;Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.27-36
    • /
    • 2010
  • It is well known that the shear strength of an RC column subjected to a lateral force decreases with the increase of the displacement ductility of column. This decreasing rate of shear strength is quite dependent on the initial shear strength. Therefore, the evaluation of the initial shear strength is important to predict the shear strength with reasonable accuracy. The shear behavior is complex because many parameters, such as the sectional shape, aspect ratio, axial force, longitudinal bars and ductility, are mutually interactive. In this study, the initial shear strength has been investigated by experiments varying parameters such as the aspect ratios, void ratios, ratio of longitudinal bars and sectional types. A new empirical equation for the initial shear strength, considering the ratio of the longitudinal bars, has been proposed and its validity has been assessed.

Failure Behavior of Non-seismic RC Column with aspect ratio of 4.0 (형상비 4.0인 비내진 철근콘크리트 기둥의 파괴거동)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.59-66
    • /
    • 2020
  • Two octagonal RC bridge columns of small scale model were tested under cyclic lateral load with constant axial load. One in two specimens was solid cross section, the other was hollow cross section. The volumetric ratio of transverse spiral hoop of all specimens is 0.00206. The columns showed flexure-shear failure. Failure behavior and seismic performance were investigated. The test results showed that the structural performance of the hollow specimen such as initial crack pattern, initial stiffness, and energy dissipation performance was comparable to that of the solid specimen, but the lateral strength, ultimate displacement, energy dissipation performance of hollow specimen noticeably decreased after drift ratio of 3%.

Punching Shear Strength of the Void Transfer Plate (중공 전이 슬래브의 뚫림 전단 강도)

  • Han, Sang-Whan;Park, Jin-Ah;Kim, Jun-Sam;Im, Ju-Hyeuk;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.367-374
    • /
    • 2010
  • The transfer slab system is a structural system that transfers the loads from the upper shear wall structure to the lower columns. This is a costly system due to a very thick slab, and the relatively high cost can be mitigated by introducing voids in the slab. However, this system of flat plate containing voids is vulnerable to brittle failure caused by punching shear in vicinity of slab-column connection. Thus, the punching shear capacity of the void system is very important. However, the current code doesn't provide a clear design provision for the strength of slabs with a void section. In this study, experimental study was conducted to investigate the punching shear strength of the void slab system. The shear strength of the specimens was predicted by current code and previous researches. In result, the punching shear strength of the void system is determined as the least value calculated at critical section located a distance d/2 from the face of the column and the center of the void section using the effective area at critical section.