• 제목/요약/키워드: 주택에너지

Search Result 600, Processing Time 0.028 seconds

Blind Optimal Operating Schedule for Reviewing the Energy Load Reduction of Apartment House (공동주택의 에너지 부하량 저감을 위한 블라인드 운영스케줄 검토)

  • Ma, Jun-ChaO;Lee, Jun-Gi;Kim, Sung-Hoon;Lee, Gab-Taek;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.63-68
    • /
    • 2016
  • In this study, through portion of the blind control which the user can adjust the deration and the main loads, night for energy reduction during the review of the energy difference between the cooling and heating load periods in order to present the best operation schedules of the blind control. The result, Cooling period, the venetian blind is installed the day or the day and night CASE adjusted to $0^{\circ}$ was identified as optimal for the operating schedule. Heating period, the day, without installed the blinds, the Venetian blind is installed only at night CASE adjusted to $0^{\circ}$ or $45^{\circ}$ angle of the slats, which have been identified as optimal for the operating schedule.

Energy Load according to the Units of Apartment House (공동주택 세대 위치에 따른 에너지 부하량)

  • Kim, Sung-Hoon;Lee, Jun-Gi;Kim, Yong-Tae;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.78-83
    • /
    • 2015
  • In Korea, multi-housing in one of the most common types of residential space due to its easy management and convenience. In particular, south-facing plate-type(一) multi-housing has attracted a great deal of public interest because it consumes less energy compared with other types of multi-housing, making it advantageous from an energy-saving perspective. Although there have been many studies on the annual energy consumption of multi-housing in relation to building shape and area of window, there have not been sufficient research on the annual energy consumption of multi-housing in relation to individual units of the multi-housing. The purpose of this study is to propose a strategy for reducing energy consumption in plate-type(一) multi-housing, taking the units with the lowest energy consumption as the standard. The result, Standard Models's energy load was as 4000 ~ 5600kWh, and Passive Houses's energy load was less than Stand Models at the 1600kWh.

A Study on Load Control Method for Home Energy Management System (H-EMS) Considering the Human Comfort (주거자 만족도를 고려한 주택 에너지관리 시스템의 부하제어 방법 연구)

  • Jeon, Jeong-Pyo;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1025-1032
    • /
    • 2014
  • The effective energy management method will provide the significant advantage to the residential customers under real time pricing plan since it can reduce the electricity charge by controlling the energy consumption according to electricity rate. The earlier studies for load management mainly aim to minimize the electricity charges and peak power but put a less emphasis on the human comfort dwelling in the residence. The discomfort and displeasure from the energy management only focusing on reduction of electricity charge will make the residential customer reluctant to enroll the real time pricing plan. In this paper, therefore, we propose optimal load control strategy which aim to achieve not only minimizing the electricity charges but also maintaining human comfort by introducing "the human comfort coefficient." Using the human comfort coefficient, the energy management system can reflect the various human personality and control the loads within the range that the human comfort is maintained. Simulation results show that proposed load control strategy leads to significant reduction in the electricity charges and peak power in comparison with the conventional load management method.

Performance Evaluation of Adhesively Fixed External Insulation and Finish System Using Vacuum Insulation Panels for Apartment Buildings (공동주택 습식 진공 외단열시스템 성능 평가)

  • Park, Si Hyun;Lim, Jae Han;Song, Seung Yeong
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.45-53
    • /
    • 2013
  • For the target goal of Zero-energy House construction in 2025, the government announced that the insulation regulations will be continuously enhanced. It has been predicted that high-performance insulation materials, such as vacuum insulation panel (VIP), should be used to decrease the thickness of outer walls. The aim of this study was to evaluate the performance of adhesively fixed external insulation and finish system (EIFS) with VIP. The energy performance of a base model with conventional internal insulation system and three alternatives of EIFS with VIP were analyzed by three-dimensional heat transfer simulation. Construction cost and convenience of each alternative were also evaluated and compared. As results, effective alternatives in terms of each performance as well as overall performance considering the weighting factors of each performance were suggested.

Analysis for Thermal Effect by an Unheated Housing Unit in Apartment (공동주택에서 비난방세대가 미치는 열적 영향)

  • Lee, Eun-Ju;Koo, Junemo;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.42-47
    • /
    • 2016
  • Adjacent housing units suffer inevitable thermal losses if an unheated unit exists in an apartment building. Thermal loss of the units adjoining the unheated apartment can be neglected because the contact area is small and insulators are located in the walls. When insulators are not included in the slab between the upper and lower units, 70% of the heat supplied by an Ondol system may be used in the original unit, but 30% is transferred to the unit on the lower floor. Another 30% can be obtained from the ceiling if the upper floor housing unit is heated. This strong thermal connection is a characteristic of Ondol heating in apartment buildings. When there is an unheated unit, the lower floor unit uses 42.3% more heating energy if there is no insulation and 19.5% if a 35 mm insulator is used as in the current guidelines. Therefore, much thicker insulation should be applied to weaken the thermal connection.

A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System (중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구)

  • Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.

  • PDF

Study on Optimal Control Algorithm of Electricity Use in a Single Family House Model Reflecting PV Power Generation and Cooling Demand (단독주택 태양광 발전과 냉방수요를 반영한 전력 최적운용 전략 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Lee, Kyoung-ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.381-386
    • /
    • 2016
  • An optimization algorithm is developed based on a simulation case of a single family house model equipped with PV arrays. To increase the nationwide use of PV power generation facilities, a market-competitive electricity price needs to be introduced, which is determined based on the time of use. In this study, quadratic programming optimization was applied to minimize the electricity bill while maintaining the indoor temperature within allowable error bounds. For optimization, it is assumed that the weather and electricity demand are predicted. An EnergyPlus-based house model was approximated by using an equivalent RC circuit model for application as a linear constraint to the optimization. Based on the RC model, model predictive control was applied to the management of the cooling load and electricity for the first week of August. The result shows that more than 25% of electricity consumed for cooling can be saved by allowing excursions of temperature error within an affordable range. In addition, profit can be made by reselling electricity to the main grid energy supplier during peak hours.

The Evaluation of Energy Efficiency of Apartment Units after Conversion of Balconies into an Integrated Part of Interior Living Space by Computing with ECO2 Software

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.11-16
    • /
    • 2016
  • Purpose: International efforts to save Earth's environment against global warming and environmental pollution have been made in many countries. Energy consumption of buildings has been continuously increasing, and it has been over 40% of total energy consumption in the world. Energy consumption of buildings in Korea reaches 24% of total energy consumption. So, Korea government has executed building energy rating systems to control energy consumption of buildings. Method: This study was carried out to evaluate the energy performance of apartment unit plans according to converting balconies into living areas. For the study, six types of input models were made. Two input models(SP1 and SP 2) were the standard units that balcony areas were not converted into living areas, and four ones(EP 1, EP 2, EP 3 and EP 4) were the extended unit plans that balcony areas were turned into living areas. All of them were simulated with ECO2 software to assess building energy efficiency. Result: According to the results, the energy performance of the EP 2 and EP 4 models were 21. 8% higher than SP 1 model and 9.2% higher than SP 2 model.

A Monitoring System of Energy Usage for Apartment Houses Using Smart TV (스마트TV를 이용한 공동주택의 에너지 사용 모니터링 시스템)

  • Park, Sungsoo;Jin, Younghoon;Nam, Sanghun;Chai, Youngho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.6
    • /
    • pp.451-460
    • /
    • 2013
  • This paper presents the necessary elements and data flow in developing a monitoring system of energy usage for apartment houses with a Smart TV. Energy consumption data in each home are collected and analyzed in the HUB station by way of measuring instruments. And the amount of energy usage, such as electricity, gas, hot water, heating, water and other utilities are displayed through the Smart TV application. Energy consumption Database in the HUB station are processed and displayed in the browser of a Smart TV through XML, JAVASCRIPT and Flash. Smart TV users can get the energy consumption status through the energy consumption analysis display of the Smart TV application and improve the energy efficiency by comparing the usage patterns with neighboring houses. And the application display energy usage information, consumption ranking, rates to user as well. Furthermore, usage of last month or year can be compared to help to reduce the energy usage. The proposed system can provide the information about the amount of energy use to be reduced and the warning on the waste of energy.

A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System (공동주택 지역난방 수질기준 설정에 관한 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Woo, Dal-Sik;Oh, June;Ahn, Chang-Koo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF