• Title/Summary/Keyword: 주택면적

Search Result 239, Processing Time 0.028 seconds

Occupants Control Patterns of Indoor Shading Devices in Apartment Buildings (공동주택 거주자의 실내 차양장치 사용행태에 관한 연구)

  • Lee, Yoon Jeong;Kim, Jeong-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.12-20
    • /
    • 2014
  • There is no comprehensive consensus of the control patterns people op::rate shadings or the motivating factors that influence their decisions. Patterns of shading devices use can affect the energy consumption of buildings. Therefore, this study aims to analyze shading device usage patterns based on the physical factors that can affect occupants behavior. First, control patterns of indoor shading devices in apartment buildings were monitored by taking pictures. Next, frequency of shading device use together with their shading portions was analyzed based on two physical factors such as window orientation and floor level. The results showed that about 35% of the monitored apartment buildings utilized indoor shading devices. Also, the south-facing apartments were more dynamically used than their east-facing counterparts. On the contrary, there was no general trend in regards to the shading operation patterns.

Feasibility Study on Remodeling Project By Using Real Option Model : Focusing on Apartment House Remodeling (실물옵션을 활용한 공동주택 리모델링 사업성 평가에 관한 연구 - 아파트 리모델링 사례를 중심으로 -)

  • Yeon, JungHoon;Lee, Hyun-Soo;Park, Moonseo;Kim, Sooyoung;Ahn, Joseph
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.39-50
    • /
    • 2014
  • After the global financial crisis, domestic construction industry has gone through a rapid recession. This resulted in gradual market shift towards architectural remodeling. Architectural remodeling not only improves residential environment but it has many advantages such as increase of each unit's exclusive area, free space within the horizontal or extension of an annex building, and increase number of household through splitting the household of bigger pyeong, etc. However, in case of the Korean market for apartment remodeling, due to various regulations and problem with business promotion procedures, majority of business is slow despite the figure that remodeling volume is not that small. Also, feasibility study which decides to push ahead public house remodeling business will have a flaw using net present value's law; it has a flaw of not considering properties of each phase of remodeling business and future's uncertainty. Hence, this research will improve the problem of traditional value assessment method of net present value's law. It will also consider one of the real options such as binomial model in order to supplement NPV which is used in current feasibility study. This research was based on real successful cases of public house remodeling and it was possible for feasibility study which was more realistic and valid. This research provided foundation for development of Korean public house remodeling market. There is high anticipation of increasing the validity by improving the problems of current feasibility study and economic efficiency assessment.

Economic Valuation of an Urban Landscape - With a Focus on Independence Park - (도시 녹지경관의 경제적 가치평가 - 독립공원을 중심으로 -)

  • Moon, Yoon-Seok;Lee, Jung-A;Chon, Jin-Hyung;Park, Ho-Jeong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.70-77
    • /
    • 2009
  • The purpose of this study is to evaluate the economic value of an urban landscape. The site of this study was Independence Park in Seoul. Before measuring economic valuation, an amount of view analysis was performed to learn the visual characteristics of the landscape. As a result, the green space ratio of the park is approximately 64%. This study estimates the intrinsic value of an urban landscape that might be included in housing prices using a hedonic price model. The hedonic price model is a statistical analysis that is often used to estimate intrinsic values of certain attributes of a product. The Box-Cox model was adopted as an analysis tool while the housing price for $3.3m^2$ was used as a dependent variable and housing and landscape features as independent variables. Results show that the value of the landscape of the Independence Park is approximately 2.2% of the housing market price. The Landscape variables of the park is the second most significant of the 8 variables. This shows that residents perceived the view of the urban landscape as one of the most significant factors in their living environment. The study also indicates that urban landscapes play important roles in improving quality of life and in influencing housing prices. The implication of the study can be said to be the potential of the urban landscape as a significant urban infrastructure. These results can be used to help make policy decisions to preserve and/or develop urban landscapes.

Qualitative Equity of Neighborhood Parks in Daegu According to Socioeconomic Status (사회경제적 지위에 따른 대구시 근린공원 질적 가치 형평성)

  • Jung, Mijeong;Jung, Taeyeol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.2
    • /
    • pp.45-55
    • /
    • 2020
  • In terms of environmental justice, urban parks play a pivotal role in imperative amenities allowing for physical activity. The reasonable distribution of urban park services must be considered in terms of community demand and the context of the park. The purpose of this study is to analyze the inequity of qualitative park service according to the socioeconomic status(SES) in Daegu. The qualitative service was assessed for 82 neighborhood and walking-distance parks by utilizing the NGST(Neighborhood Green Space Tool). The inequity was analyzed by SES variables(ratio of basic living recipients, ratio of single-parent families, average housing sales, dilapidated dwelling ratio, and park area per capita). The features of the qualitative equity in Daegu is as follows. First, urban park planning in Daegu is in parallel with the development of residential areas rather than the local policy. The development pattern of parks stretching from center of the city to outskirts clearly dissociates the city based on socioeconomic status. The parks in the center are relatively old and poorly managed. Second, overall neighborhood parks lacked recreational facilities. The facilities are significantly influenced by the housing values around them. The lower the recreation facility score, the higher the floor gradient of the urban parks constraining physical activities. Third, the quantitative supply of parks has nothing to do with the quality of the urban parks. Green space distribution is highly dependent on natural park areas, so the park area per capita cannot be a standard for assessing qualitative equity.

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

A Study on the Calculation of Thermal Consumption Unit of Apartment (공동주택의 열사용량원단위 산정에 관한 연구)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.388-393
    • /
    • 2014
  • Energy consumption unit in a building is classified according to uses of electricity, gas, and oil, and it has been studied steadily as a material for establishing policy standards for energy saving in buildings. Meanwhile, consumption unit in apartment house can be calculated differently according to its survey method and area standard. Therefore, with the necessity of reestablishing energy consumption unit, this study has researched thermal energy consumption, Supply dwelling area Exclusive dwelling area, completion year and housing type of 23,791 households of 31 complex in Daejeon. As a result, (1) there was about 20% difference between supply and exclusive dwelling areas. (2) On the basis of exclusive dwelling area, thermal energy consumption unit was calculated as $104.9kWh/m^2{\cdot}a$ in 2010, $104.6kWh/m^2{\cdot}a$ in 2011, and $107.7kWh/m^2{\cdot}a$ in 2012.

Change Detection of Building Demolition Area Using UAV (UAV를 활용한 건물철거 지역 변화탐지)

  • Shin, Dongyoon;Kim, Taeheon;Han, Youkyung;Kim, Seongsam;Park, Jesung
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_2
    • /
    • pp.819-829
    • /
    • 2019
  • In the disaster of collapse, an immediate response is needed to prevent the damage from worsening, and damage area calculation, response and recovery plan should be established. This requires accurate detection of the damage affected area. This study performed the detection of the damaged area by using UAV which can respond quickly and in real-time to detect the collapse accident. The study area was selected as B-05 housing redevelopment area in Jung-gu, Ulsan, where the demolition of houses and apartments in progress as the redevelopment project began. This area resembles a collapsed state of the building, which clear changes before and after the demolition. UAV images were acquired on May 17 and July 9, 2019, respectively. The changing area was considered as the damaged area before and after the collapse of the building, and the changing area was detected using CVA (Change Vector Analysis) the Representative Change Detection Technique, and SLIC (Simple Linear Iterative Clustering) based superpixel algorithm. In order to accurately perform the detection of the damaged area, the uninterested area (vegetation) was firstly removed using ExG (Excess Green), Among the objects that were detected by change, objects that had been falsely detected by area were finally removed by calculating the minimum area. As a result, the accuracy of the detection of damaged areas was 95.39%. In the future, it is expected to be used for various data such as response and recovery measures for collapse accidents and damage calculation.

Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment (공동주택에서 지열 냉난방 시스템 적용시 경제성 분석)

  • Park, Yongboo;Park, Jongbae;Lim, Haesik;Baek, Sungkoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.11-18
    • /
    • 2007
  • This paper studied the economical efficiency of ground source heat pump system under various conditions in apartments which have important effects on the housing market. And this study analysed the initial cost increase, saved managing cost and recovery time of initial cost. Analysis result showed as time of heating-cooling and water heating increases, the amount of saved managing cost increased much than the initial construction cost, so recovery time shortened. And as the net area of apartment increases, the recovery time increased. The study of the relation between the installation type and recovery time of initial construction cost showed when heat-cooling system adapted ground source heat and water heating system adapted waste heat, the initial construction cost was recovered most quickly. When Ground Source Heating system was used for the heating-cooling and water heating system, ground source heating system was used for the heating-cooling and waste heat used for water heating, and ground source heating system was used for the heating-cooling and LNG used for water heating, the construction cost increased 72,000, 66,900 and 62,300 won each per $m^2$ compared to the current system (package air-conditioner, heating and water heating using LNG).

  • PDF

Residential Choice and Mobility of Korean Babyboomer after Retirement (한국 베이비붐세대의 은퇴 후 주거 선택과 이동 특성)

  • Lim, Ki-Heung;Baek, Sungjoon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.438-449
    • /
    • 2014
  • This paper is aimed to study on residential choice after retirement. For this reason, this study is analyzed in three aspects ; the factors of residential choice, preferred house types and scales, the characterization of residential mobility. This study reached several conclusions. Firstly, Korea baby boomers are likely to select their residence with different factors after retirement, and they are likely to choose their residence in the view of comfort and convenience. Secondly, apartment resident ratio is shown to be reduced after retirement, and the preference for the country houses and town houses is shown to be increased. Thirdly, the baby boomers don't reduce their residential scale in batches, while they are to show a different appearance depending on the retention scale of housing. Fourthly, The 62.4% of Korean baby boomers is to plan move their residences after retirement, 52.3% of movers, more than half of them, is to go to the different residential area. Fifth, it is analyzed that different variables are to influence on the local and regional of residential mobility of the baby boomers in Korea.

Indoor Visual Environmental Estimate Experiment Evaluation of See Through BIPV Curtainwall System (가시성확보 BIPV 커튼월시스템의 실내 시환경 예측 시험 평가)

  • Cha, Kwangseok;Jo, Boram
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.108-108
    • /
    • 2011
  • 공동주택에서 2025년 정부가 추진하고 있는 Zero Energy 건축물 구현과 친환경에 대한 탄소배출 저감 문제로 재생에너지 생산시스템의 추가 적용은 반드시 필요하다. 따라서 공동주택 적용 및 활용성을 높일 수 있는 BIPV시스템 개발을 통하여 설치면적 확보와 세대 활용성을 높일 수 있도록 하는 것이 필요하다. 특히 거실 창호의 경우 주방향이 남향, 남동 또는 남서향으로 배치되어 태양광을 적용하기에 적합한 특성을 가지고 있다. 그러나 창호는 건물외피의 역할과 재실자가 조망과 정보취득을 얻을 수 있는 중요한 통로가 되기 때문에 단열 문제나 시야 차폐의 문제는 발생하지는 않도록 하는 것이 필요하다. 본 연구에서는 a-si타입 모듈 2개를 10% 투과율로 Bsck Coating 색상을 달리한 모듈과 c-si BIPV 모듈을 커튼월 창호시스템으로 개발, 일반 2중 창호시스템과 비교 평가를 위해 실제 Test bed 건물에 시공하여 시환경 및 실내 창측면 온도변화 측정 분석을 진행하였다. 현재 국내외 출시되고 있는 a-si see through 모듈은 10~30%의 투과율로 창 마감재로 대체가 가능하나 건축 환경(시환경,열환경)에 대한 분석은 전무한 상태이다. 본 연구에서는 시환경과 창유리면의 열 부하, 자외선, 적외선 차폐 및 가시광선의 투과율에 대한 평가와 Back Coating에 따른 색온도 평가를 통해서 a-si BIPV의 공동주택 세대 발코니 창호 적합성에 대한 검토를 진행하였다. 연구결과는 아래와 같다. ${\bullet}$ 실내조도는 청천공 정오기준 가시성 확보 모듈의 경우 2,300 ~ 3,500lx를 나타내고 있어 대비 현상이나 창측의 급격한 조도 변화가 적은 시환경 구축이 가능 ${\bullet}$ 12시경 휘도는 창측면, 실내 벽체, 코너 바닥면을 대상으로 a-si BIPV 모듈을 적용한 경우 휘도비가 12:1로 KS나 IESNA의 광원과 근접면의 비 20:1 범위에 모두 존재, 적합한 것으로 분석되었으나 c-si의 경우는 그림자로 인한 대비 현상이 발생, 작업 시환경 문제 발생. ${\bullet}$ 이중시스템 창호와 비교하여 단열 성능 떨어짐. 발전시간대 창유리 면 온도 상승 으로 하절기 냉방부하 증가. ${\bullet}$ 자외선은 100% 가까이 차단, 적외선은 13~42%만 투과되고 가시광선은 13% 투과율을 나타내어 일반 창에 칼라 코팅을 적용하는 것과 유사한 경향을 나타냄.

  • PDF