• Title/Summary/Keyword: 주사기

Search Result 1,122, Processing Time 0.025 seconds

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

Synthesis of Methanol from Carbon Dioxide (I). Study on Cu / ZnO Catalyst System (이산화탄소에 의한 메탄올 합성 (제 1 보). Cu / ZnO 촉매계 연구)

  • Sung Yun Cho;Ki Won Jun;Dae Chul Park;Kyu Wan Lee
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.558-567
    • /
    • 1989
  • The synthesis of methanol from carbon dioxide and hydrogen was studied for various compositions of Cu/ZnO catalyst system. Effect of the composition ratio of CuO and ZnO on the catalytic activity in the above reaction and the relationship between the activity and the characteristics of the catalysts were explained from the result of surface area measurements, SEM, XRD, and XPS. The major products of the reaction were methanol and carbon monoxide. The selectivity to methanol increased with increase of the copper oxide content in the catalyst up to CuO: ZnO = 30:70 weight ratio, and decreased rapidly when the content is above 70%. SEM and BET measurements, indicate that this point corresponds to the increasing point of the catalyst crystallite size and the decreasing point of the surface area. As to the Cu/Cu + Zn atomic ratio, the surface concentration of copper measured by XPS decreased remarkably when the copper oxide content in catalyst was higher than 50%. All the unreduced catalysts had almost same binding energy of Cu(2P3) level, but the binding energy for $Cu(2P^3)$ level of reduced catalysts was lowered than that of calcined catalysts. The surface copper species which was in the maximum amount when the CuO:ZnO composition in the catalyst was 30:70, existed as zero valent copper. This result agreed with the experimental result that the highest rate of methanol formation was observed when the CuO content in the catalyst was 30%. It was postulated that these reduced catalysts performed with a relatively strong basicity because the formation rate of acetone was higher than that of propylene in isopropanol decomposition as measured in a pulse type reactor.

  • PDF

Potentiation of Antitumor Effect of Radiotherapy by Recombinant Tumor Necrosis Factor-$\alpha$ (방사선의 항암작용에 대한 재조합 TNF-$\alpha$의 효과)

  • Seong Jinsil;Shin Hang Chul;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.225-231
    • /
    • 1998
  • Purpose : To determine whether TNF-$\alpha$ increases the antitumor effect of radiotherapy in murine syngeneic tumor system. Materials and Methods : Syngeneic murine tumors of MCa-K or MCa-4 (mammary carcinoma), OCa-I (ovarian carcinoma), or HCa-I(hepatocarcinoma were grown in hind legs of C3Hf/HeJ mice. When tumors were grown to 6 mm in mean diameter mice were treated with TNF-$\alpha$, radiation, or combination of the both. Gamma-radiation was given as a single dose of 30 Gy for HCa-I and 15 Gy for other tumors using Cobalt-60 teletherapy unit. A novel TNF-$\alpha$ mutein developed in Korea, was intraperitoneally administered daily at a dose of 10 ug per mouse for 7 days. In combination of radiation and TNF-$\alpha$, the drug was started 1 hour after radiation. Tumor growth delay assay was used to measure the tumor response to the treatment. Results : Among 4 tested tumors, TNF-$\alpha$ alone showed significant antitumor activity in MCa-K and OCa-I tumors, which showed absolute growth delay (AGD) of 5.0 days and 6.5 days, respectively. In combination with radiation, TNF-$\alpha$ showed significant delay of AGD (41.1 days) in OCA-I compared to AGDs of TNF-$\alpha$ alone and radiation, i.e., 6.5 days and 26.9 days, respectively(p<0.05). Enhancement factor was 1.29 in OCa-I, which showed supraadditive effect. TNF-$\alpha$ did not show significant delay of AGDs in the remaining 3 tumors compared to AGDs of TNF-$\alpha$ alone and radiation. Conclusions: TNF-$\alpha$ alone showed antitumor effects in MCa-K and OCa-I. In combination with radiation, TNF-$\alpha$ acted in supraadditive way in OCa-I only. The results of this study imply that the combination of TNF-$\alpha$ and radiation has different therapeutic potential depending on tumor model and further study is advocated.

  • PDF

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

The effect of 8 French catheter and chest tube on the treatment of spontaneous pneumothorax (자연기흉에 있어서 8 French 도관과 흉관의 삽입 치료 효과)

  • Kang, Yoon-Jeong;Koh, Hyoung-Gee;Shin, Jong-Wook;Lim, Seong-Yong;Choi, Jae-Sun;Yu, Ji-Hoon;Park, In-Won;Choi, Byoung-Whui;Hue, Sung-Ho;Seo, Seung-Cheon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.410-419
    • /
    • 1996
  • Background : Spontaneous pneumothorax have been managed with a variety of methods. The technique most frequently used is chest tube drainage. Small caliber catheters were first used in the management of pneumothorax complicating the percutaneous needle aspiration lung biopsy, and the try to treat spontaneous pneumothorax also has been reported. However, the value of small caliber catheters in spontaneous pneumothorax has not been fully evaluated. So, we tried to elucidate the efficacy of 8 French catheter in the management of spontaneous pneumothorax. Method : From January, 1990, to April, 1994, 44 patients with spontaneous pneumothorax treated at Chung-Ang university hospital were reviewed. The patients were sub-divide into 8 French catheter insertion group (n=21) and chest tube insertion group (n=23). We compared the presence of underlying lung disease, the extent of the collapse, the duration of indwelling catheter and complication between two groups. Results : 1) The duration of indwelling showed no significant difference between 8 French catheter group and chest tube. But, complication after insertion as subcutaneous emphysema was developed in only chest tube group. (p<0.05) 2) In the primary spontaneous pneumothorax, all case of the pneumothorax of which size was less than 50% showed complete healing with 8 French catheter insertion. Whereas the success rate in patients with large pneumothorax (more than 50%) was tended to be dependent on the age. 3) In the patients with secondary spontaneous pneumothorax who were managed with 8 French catheter, the success rate was trended to be high if the underlying disease of pneumothorax was not COPD and if the patient was young. Conclusion : These results show that 8 French catheter insertion probably was effective in the pneumothorax less than 50%, the primary spontaneous pneumothorax, young age or secondary pneumothorax not associated with COPD.

  • PDF

List-event Data Resampling for Quantitative Improvement of PET Image (PET 영상의 정량적 개선을 위한 리스트-이벤트 데이터 재추출)

  • Woo, Sang-Keun;Ju, Jung Woo;Kim, Ji Min;Kang, Joo Hyun;Lim, Sang Moo;Kim, Kyeong Min
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2012
  • Multimodal-imaging technique has been rapidly developed for improvement of diagnosis and evaluation of therapeutic effects. In despite of integrated hardware, registration accuracy was decreased due to a discrepancy between multimodal image and insufficiency of count in accordance with different acquisition method of each modality. The purpose of this study was to improve the PET image by event data resampling through analysis of data format, noise and statistical properties of small animal PET list data. Inveon PET listmode data was acquired as static data for 10 min after 60 min of 37 MBq/0.1 ml $^{18}F$-FDG injection via tail vein. Listmode data format was consist of packet containing 48 bit in which divided 8 bit header and 40 bit payload space. Realigned sinogram was generated from resampled event data of original listmode by using adjustment of LOR location, simple event magnification and nonparametric bootstrap. Sinogram was reconstructed for imaging using OSEM 2D algorithm with 16 subset and 4 iterations. Prompt coincidence was 13,940,707 count measured from PET data header and 13,936,687 count measured from analysis of list-event data. In simple event magnification of PET data, maximum was improved from 1.336 to 1.743, but noise was also increased. Resampling efficiency of PET data was assessed from de-noised and improved image by shift operation of payload value of sequential packet. Bootstrap resampling technique provides the PET image which noise and statistical properties was improved. List-event data resampling method would be aid to improve registration accuracy and early diagnosis efficiency.

Biological Activities and Artificial Cultivation of Cordyceps pruinosa Petch (붉은자루동충하초의 자실체 증식 특성)

  • Hong, In-Pyo;Nam, Sung-Hee;Jung, I-Yeon;Sung, Gyoo-Byung;Kim, Hyun-Bok;Jung, In-Mo;Cho, Soo-Muk;Lee, Min-Woong
    • Journal of Mushroom
    • /
    • v.3 no.4
    • /
    • pp.133-139
    • /
    • 2005
  • Fruiting bodies of Cordyceps have been regarded as popular folk and effective medicines to treat human diseases such as asthma, bronchial and lung inflammation, and kidney disease. Cordyceps pruinosa (Clavicipitaceae; Hypocreales; Ascomycotina) has received special attention for medicinal purpose due to its various physiological activites. The nucleoside derivative N6-(2-hydroxyethyl) adenosine (HEA) isolated from it showed a $Ca^{2+}$ antagonistic effect and negative inotropic response. The artificial production of fruiting body of C. pruinosa has not been tried successfully yet by using living silkworm substrate. To develop techniques for the production of C. pruinosa stromata on a large scale, the infection of Bombyx mori with C. pruinosa and the growth characteristics of stroma of C. pruinosa were investigated. Also, studied about biological activities of fruiting body formed on silkworm. Infection rate of the silkworm pupae with C. pruinosa was the highest in injection inoculation. The formation of the fruiting body of C. pruinosa was quite good in the room controlled at $21{\sim}25^{\circ}C$, over 91% of relative humidity and over 1500 lx. Glucose concentration was high in the fruiting bodies of the silkworm pupae infected with C. pruinosa on a dry weight basis. The most abundant amino acid in the fruiting bodies was arginine and phenylalanine. The fruiting bodies of silkworm pupae infected with C. pruinosa was rich in oleic acid. The high amount of citric acid was found in the fruiting bodies of silkworm pupae infected with C. pruinosa.

  • PDF

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS (반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석)

  • Hwang, Soo-Youn;Oh, So-Ram;Lee, Yoon;Lim, Sang-Min;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 2009
  • This study aimed to assess the influence of different cross-sectional area on the cyclic fatigue fracture of Ni-Ti rotary files using a fatigue tester incorporating cyclical axial movement. Six brands of Ni-Ti rotary files (ISO 30 size with. 04 taper) of 10 each were tested: Alpha system (KOMET), HeroShaper (MicroMega), K3 (SybronEndo), Mtwo (VDW), NRT (Mani), and ProFile (Dentsply). A fatigue-tester (Denbotix) was designed to allow cyclic tension and compressive stress on the tip of the instrument. Each file was mounted on a torque controlled motor (Aseptico) using a 1:20 reduction contra-angle and was rotated at 300 rpm with a continuous, 6 mm axial oscillating motion inside an artificial steel canal. The canal had a $60^{\circ}$ angle and a 5 mm radius of curvature. Instrument fracture was visually detected and the time until fracture was recorded by a digital stop watch. The data were analyzed statistically. Fractographic analysis of all fractured surfaces was performed to determine the fracture modes using a scanning electron microscope. Cross-sectional area at 3 mm from the tip of 3 unused Ni-Ti instruments for each group was calculated using Image-Pro Plus (Imagej 1.34n, NIH). Results showed that NRT and ProFile had significantly longer time to fracture compared to the other groups (p < .05). The cross-sectional area was not significantly associated with fatigue resistance. Fractographycally, all fractured surfaces demonstrated a combination of ductile and brittle fracture. In conclusion, there was no significant relationship between fatigue resistance and the cross-sectional area of Ni-Ti instruments under experimental conditions.

Detection of TNF-alpha in Serum as the Effect of Corticosteroid to the Myocardial Protection in Cardiopulmonary Bypass (체외순환시 스테로이드의 심근보호효과에 관한 혈청내 TNF-alpha 측정의 의의)

  • 최영호;김욱진;김태식;조원민;김학제
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.502-508
    • /
    • 1998
  • Proinflammatory cytokines such as tumor necrosis factor-$\alpha$(TNF-$\alpha$) have been implicated in myocardial and organ dysfunction associated with postperfusion syndrome. We tested the hypothesis that cytokine productions are depressed by preoperative cortiosteroid injection for cardiopulmonary bypass(CPB) and the postoperative courses will be better than without steriod pretreated cases. Cardiac surgery was performed in randomized blind fashion for 20 patients from June 1996 to September 1996. In the steroid group(n=10), corticosteroid(dexamethasone 1 mg/kg) was injected 1 hour before anesthetic induction, but in the control group(n=10), nothing was injected. Each of groups were sampled 11 times as scheduled for TNF-$\alpha$ bioassays. We have checked EKG, cardiac enzymes(CPK, LDH with isoenzyme), WBC count preoperative day, one day and three days after operation. Viatal signs were continuously monitored for three postoperaive days. In the postoperative period three patients in the control group had elevated body temperature and four patients had hypotension that required considerable intravenous fluid administration. But steroid injected patients showed normal body temperture and acceptable blood pressures without supportive treatment. CPK enzymes rose in control group higher than steroid group at postoperative 1st and 3rd day(CPK; 1122$\pm$465 vs 567$\pm$271, 864$\pm$42 vs 325$\pm$87), and CPK-MB enzymes rose in control group higher than steroid group at postoperative 1st day(106.4$\pm$115.1 vs 29.5$\pm$22.4)(P=0.02). Arterial tumor necrosis factor-$\alpha$ rose during cardiopulmonary bypass, peaking at 5 minutes before the end of aortic cross clamping(ACC-5min) in steroid group(11.9$\pm$4.7 pg/ml), and 5 minutes before the end of cardiopulmonary bypass(CPB-5min) in control group(22.3$\pm$6.8 pg/ml). The steroid pretreated patients had a shorter period of time in respirator suport time, ICU stay day, hospital admission day. We conclude that corticosteroid suppress cytokine production during and after cardiopulmonary bypass, and may improve the postoperative course through inhibition of reperfusion injury such as myocardial stunning and hemodynamic instability.

  • PDF