• Title/Summary/Keyword: 주방설비

Search Result 61, Processing Time 0.027 seconds

HACCP Model for Quality Control of Sushi Production in the Eine Japanese Restaurants in Korea (일본전문식당의 급식품질 개선을 위한 HACCP 시스템 적용 연구)

  • 김혜경;이복희;김인호;조경동
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.13 no.1
    • /
    • pp.25-38
    • /
    • 2003
  • This study was conducted to establish the microbiological quality standards applying the HACCP system on sushi items of Japanese restaurant in Korea. The study evaluated hygienic conditions of kitchen and workers, pH time-temperature relationship, and microbial assessments during whole process of sushi making in 2001. Overall hygienic conditions were normal for both kitchen and for workers by 3 point scale, but hygienic controls against the cross-contamination were still needed. Each process of sushi making was performed under the risk of microbial contamination, since pH value of most of ingredients was over pH 4.6 and also production time(3.5~6 hrs) were long enough to cause problems. Microorganisms were high enough to cause foodborne illness ranged 8.0$\times$10$^2$~3.3$\times$10$^{6}$ CFU/g of TPC and 1.0$\times$10$^1$~1.6$\times$10$^3$CFU/g of coliforms, although TPC, coliforms and Staphylcoccus aureus were within the standard limits (TPC 10$^2$~10$^{6}$ CFU/g, coliforms 10$^3$CFU/g). However, Salmonella and Vibrio parahaemolyticus were not detected. High populations TPC and coliforms were also found in the cooks' hands and cooking utensils(TPC 10$^2$~10$^{6}$ CFU/100cm$^2$and Coliforms 10$^1$~10$^3$CFU/100cm$^2$). Based on the CCP decision tree analysis, the CCPs were the holding steps far six sushi production line except the tuna and the thawing step for tuna sushi. In conclusion, overall state of sushi production was fairly good but much improvement was still needed.

  • PDF

A Study on the Pressure Drops of T-Branch Pipes (분기배관의 압력강하에 관한 연구)

  • Nam, Jun-Seok;Baek, Chang-Sun;Kwon, Soon-Kwan;Kim, Dong-Hyun;Min, Kyung-Tak;Kim, Byoung-Gon;Lee, Sung-Ho
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.272-277
    • /
    • 2008
  • This study is performed for propose that exactly equivalent length of TBP in the applied at water-based fire protection system. For predict the measuring position of equivalent length, we determined the measuring position using the FVM about pressure drop of TBP. For the reckon of the exact about measured value we compared with the result of FVM and we knew the similar value each other. Using the results we proposed the friction loss measuring position that inlet of main dirction is 20 times of appellation diameter in main pipe, outlet of main dirction is 10 times of appellation diameter in main pipe and outlet of branched direction is 20 times of appellation diameter.

On Kitchen Workers' Job Stress Caused by Kitchen Facilities (주방 설비가 조리 종사원의 직무 스트레스에 미치는 영향에 관한 연구)

  • Jung, Jin-Woo
    • Culinary science and hospitality research
    • /
    • v.13 no.3
    • /
    • pp.263-277
    • /
    • 2007
  • In order for a cook to cook, there should be a space called a kitchen; moreover, to prepare good food, there should be good kitchen facilities in the kitchen. With good facilities, the cook can save time and have higher productivity. On the other hand, with poor facilities, equipment and utensils, the cook can get demotivated, have poor capability, suffer from high stress and possibly can cause some diseases. Therefore, better facilities are essential for cooking environment. The purpose of this study is to find out how significant the job stress is according to the demographic characteristics. Also, how kitchen facilities and moving line influence the job stress. In order to answer above questions, 278 copies of questionnaire were made and given to cooks at hotels with five star or similar ranks. Using SPSS Win 12.0 the statistics package, frequency, factor and reliability analysis were conducted. Then, regression analysis was carried out. As a result of the test, difference analysis on statistic characteristics was partly found. In addition, facilities and moving line affected job stress. Also, working area in the kitchen inversely influenced the job stress.

  • PDF

Perceived Importance of Kitchen Equipment and Facilities on Cook's Hygienic Performance in Deluxe Hotels (특급호텔주방의 위생관련 시설 및 설비에 대한 중요도 인식에 따른 조리사의 위생관리 직무수행도 평가)

  • Yoo, Seung-Seok;Shin, Young-Chel
    • Korean journal of food and cookery science
    • /
    • v.23 no.1 s.97
    • /
    • pp.25-32
    • /
    • 2007
  • The objective of this study was to investigate the effect of the perceived importance of kitchen equipment and facilities on the hygienic performance of cooks in deluxe hotels. Cooks and chefs at 7 different deluxe hotels participated in this study. Out of 490 questionnaires administered, 456 (93.1%) were completed and 419 (91.9%) were analyzed using a statistical package SPSS 12.0. The results were as follows. First, the correlation between sanitary equipment, including HACCP system, in the hotel kitchens and the hygienic management performance confirmed the significant effect of the sanitary equipment on the performance of the cooks and chefs. Second, the sanitary facilities in the hotel kitchens greatly affected the hygienic management performance. The results also demonstrated that the sanitary equipment provided the same contribution to the performance irrespective of the job level, management type and HACCP practice. However, the sanitary facilities greatly affected the management type expecially the chain hotels. The hygienic management performance did not affect the cooking stage (before-cooking and during-cooking), but affected the after-cooking stage according to the management type and the HACCP practice, but not the job level.

Analysis on the Discharge Characteristics of New Cell Structure for Luminous Efficacy Improvement in an AC Plasma Display Panel (교류형 플라즈마 표시키의 발광 효율 개설을 위한 실 구조의 방전 특성 분석)

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.7-13
    • /
    • 2008
  • Through two-dimensional numerical simulations, we analyzed the effects of new cell structure for the luminous efficacy improvement in an ac plasma display panel. In the new structure with 5 electrodes, two auxiliary electrodes are arranged between X and Y electrodes with long gap. Through the application of adequate auxiliary pulse on the address electrode, the luminous efficacy in the new cell structure showed the improvement of 52[%] in comparison with that of conventional cell structure with short gap between X and Y electrodes. Consequently, as the short gap discharge between auxiliary electrodes decreases and the long gap discharge between X and Y electrodes increases, the result of VUV generation efficacy shows higher improvement. The reliability of simulation result could he confirmed by the experimental result in the test panel.

Preferences of Stroke Patients for Kitchen Environment in Residential Space (주거공간의 부엌 환경 특성에 대한 뇌졸중 환자의 선호)

  • Baek, Da-Rae;Jung, Yeon-Jin;Kang, Suk-Gu;Kim, Hee-Jung;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • Objective : The purpose of this study was to investigate the preferences of kitchen environment for stroke patients. Methods : The subjects of this study were 97 who have experience in rehabilitation therapy at hospitals in Busan. A questionnaire was distributed and collected from February 24th to March 13th, 2014. Descriptive statistics of frequency Study were used to analyze data. Results : First, the subjects demand for improvement that use a chair for work and install non-slip tiles. Second, they preferred the non-slip mat, boilers in heating equipment, drawer storage, L-shaped safety handle, adjustable sink of the height, automatic cutout of gas leak, faucet of touch-sensitive type, ㄷ-shaped kitchen and the ceiling-type hood in ventilation system. Third, they need kitchen items such as the sink self coming down, scissors for slices and knife to avoid hand injury. Conclusion : This study would contribute to kitchen environment for fall prevention and ease in use.

  • PDF

Recognition Study on Introduction of HACCP to Industry Foodservice (사업체 급식의 HACCP 제도 도입을 위한 인지도 조사)

  • 이헌옥;심재영;신현아;정덕화;엄애선
    • Korean journal of food and cookery science
    • /
    • v.18 no.3
    • /
    • pp.355-364
    • /
    • 2002
  • For the introduction of HACCP to industry food service, a survey was conducted from 150 dieticians and 40 managers on their recognition on HACCP system. The questionnaire of the survey included the status of current food safety management, management responsibilities, recognition on HACCP, problems in HACCP introduction. The majority of respondents was satisfied with the current food safety management, and the food service managers were more confident than dieticiant in terms of food safety. Foodservice managers (100%) and dieticians (96%) recognized HACCP system; however, they responded the application of HACCP to industry food service were only 27% and 12.5%, respectively. They pointed out the reasons that they cannot introduce HACCP to their industry food service were the lack of benefits and good facilities. Dieticians strongly recognized the need of correction oi food safety manasement in industry food service, compared with food service managers. The results suggest that the introduction of HACCP to industry food servife should be accomplislled by continuous education and information on food safety, improving facilities and a variety of benefits to HACCP-implemented companies from the government.

Developement of a Design Manual for Kitchen Facility in Foodservice Outlets: A Case Study on a Seolleongtang Specialized Restaurant (푸드서비스시설의 주방 설비 산정 매뉴얼 개발: 설렁탕 전문 식당 사례 적용)

  • Choi, Gyeong-Gy;Chang, Hye-Ja
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.67-77
    • /
    • 2021
  • Concerns regarding work and food safety in foodservice operations are growing. The purpose of the study is to suggest guidelines for designing foodservice facilities, including school foodservices and Korean restaurants. A case of a franchise restaurant specializing in a Korean food item, Seolleongtang, was used to explain the facility design. The contents of the manual included ways to determine space allocation, calculate the application of utilities and the diameters of supply utility pipelines, and suggestions on how to decide on air conditioning equipment. The standards of the American Gas Association and the Japan Foodservice Equipment Association (JFEA) were applied to design the restaurant space. The JFEA standards and knowledge based on experience and statistics were applied to calculate the usage of utilities like fuel and water. The standards of JFEA and the Society of Heating, Air-Conditioning, and Sanitary Engineers of Japan were applied to calculate the diameters of the water supply and drainage pipelines. For the setting of the heating, ventilation, and air conditioning systems, three ways to carry out the calculation of effective ventilation were explained, as well as options to dicide the standard parameters of the duct and ventilation fans. This manual can contribute to the design of effective and efficient foodservice facilities and help secure the work safety of foodservice employees thereby ensuring food safety.

The Microbiological Evaluation of Environments and Facilities at Food Service Operations in Elementary School (초등학교 단체급식 소의 환경과 급식설비에 대한 미생물 평가)

  • 정동관;류은순
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.2
    • /
    • pp.216-220
    • /
    • 2002
  • The microbiological examinations of food service operations were conducted for the hygienic evaluation at four elementary schools in Busan, Korea. Total one hundred and seventy two swabbed samples using sponge were collected from the surface of environments, utensils and equipments of food service facilities and analyzed by measuring the total, coliform and psychrotrophic count. Sampling sites were the surfaces of floors, drains, walls, knives, cutting boards, rubber gloves, vinyl aprons, plastic containers, carriers, shelves, trays, dry shelves, electric tray dryer, food containers, soup containers, rice cookers, frying pans, boiling cookers, refrigerators, dumb waiters and dishwashers. The swabbed samples kept in an ice-parked box were transported to a laboratory and analyzed. The results demonstrated that the degree of contamination depended on the sampling sites. Averages of total counts of surface swab samples were ranged from 0.62 to 7.79 Log CFU/200 cm$^2$. The level of coliforms were ranged from not detectable to 5.26 Log CFU/200 cm$^2$, and those of psychrotrophs from not detectable to 6.15 Log CFU/200 cm$^2$. The severely contaminated sites were dumb waiters, drains, rice cookers, knives, plastic containers and floors. Also cutting boards, rubber gloves, carriers, drying shelves, vinyl aprons, boiling cookers, soup containers, frying pans and refrigerators were highly contaminated with the level of abode 3.5 Log CFU/200 cm$^2$. Therefore, those sites should be focused and controlled according to control points of sanitation standard operating procedures (SSOP). Also, periodic microbiological examination in addition to visual examination is recommended on these highly contaminated sites indicated above results at food service operations in elementary school.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.