A Numerical Study on the Particle Collection Characteristics of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 입자포집 특성에 관한 수치해석)

  • 김기정;배귀남;김영일;허남건
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.792-800
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^3$/h. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The air velocity and pressure distributions were discussed in detail. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and 100㎥/h. The particle collection efficiency of a grease filter increases with increasing the particle diameter, the particle density, and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter. The cut-off diameter of the tested grease filter representing 50-% collection efficiency is about 11.6$\mu$m for water droplets at $100m^3$/h.

A Study on the Improvement Strategies for Exhaust Performance in Commercial Kitchen Hoods (상업용 주방후드의 배기성능 개선방안에 관한 연구)

  • 박진철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.439-445
    • /
    • 2003
  • The purpose of this study is to suggest the improvement strategies for exhaust performance in composite kitchen hoods. The Exhaust only hood, the 2-way compensating hood and the 3-way compensating hood were selected, and the laboratory experiments were performed to compare the local exhaust efficiency and the indoor temperature distributions according to the variations of the hood type and supply/exhaust air velocity. The results of this study can be summarized as follows. The compensating hood has better performance than exhaust only hood in the aspect of local exhaust efficiency and temperature distribution. The 3-way compensating hood shows the best performance when the supply air velocity is about 2.7 m/s, and the 2-way compensating hood at the supply air velocity of 3.5 w/s. In the same exhaust rate condition, if the exhaust area of the hood is increased and therefore the exhaust velocity is lowered, the supply air velocity is also lowered to get the optimum performance. The optimum exhaust velocity range of the commercial kitchen hood which derived from this study is 0.48 ∼ 0.55 m/s.

Exhaust Characteristics of Kitchen Hood System with Inclined Air Curtain (에어커튼형 주방 레인지후드의 배기 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.594-599
    • /
    • 2014
  • There have been many cases that the air curtain installed in the apartment can not well remove the gases such as carbon dioxide and particles such as smokes, oils and vapors generated during the cooking to disperse the pollutants into the room. This study uses the numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed on the range hood of kitchen. As a result of the study, it turned out that, when the air amount supplied by air curtain through the slot was about 60% of exhaust amount, the capturing efficiency of range hood for pollutants increased by 70~80% more than the case without the air curtain. Even when the exhaust amount was small, the capturing efficiency was improved a lot with the use of air curtain. In case that the air flow velocity of slot was greater than 2 m/s, the capturing efficiency turned out to decrease.

Performance Analysis and Testing of a Cross-Flow Aluminum Heat Exchanger for Kitchen Ventilation (주방환기용 직교류 알루미늄 열교환기의 성능해석 및 시험)

  • Kim N.H.;Cho J.P.;Han S.P.;Choi J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.193-201
    • /
    • 2006
  • Thermal performance model was developed for a cross-flow aluminum heat exchanger with relatively short passage. Appropriate heat transfer coefficient and friction factor equations for laminar channel flow were obtained considering developing regions. The heat exchanger was analyzed using the unmixed cross-flow ${\epsilon}$-NTU relationship considering leak-age between streams. Thermal contact between corrugations and plates was also considered. Tests were separately conducted for two samples - one made of non-treated aluminum sheets, and the other made of varnish-treated ones. The samples were made by stacking corrugations and plates one after another. The model adequately predicted the thermal performance and pressure drop of the non-treated heat exchanger. The thermal performance of the varnish-treated one was $7{\sim}12%$ overpredicted, and the pressure drop of the varnished-treated heat exchanger was $5{\sim}15%$ underpredicted. The air leakage ratio of the non-treated heat exchanger was $23{\sim}26%$. The ratio decreased to less than $10%$ with the varnish treatment.

Prediction of the ventilation performance in a kitchen with various locations of gas range and window (가스렌지와 창문위치에 따른 주방 배기성능 예측)

  • 김경환;이재헌;박명식;이대우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

A Numerical Study on the Design of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 형상설계에 관한 수치해석)

  • 김기정;배귀남;김영일;허남건
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.619-629
    • /
    • 2003
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. Since the inertial impaction is a dominant particle removal mechanism of the grease filter, the performance of the filter is greatly affected by the geometry. This numerical study has been conducted to investigate the effect of geometry on the performance of grease filters for four models having nominal flowrate of 100 m$^3$/h. Four models were designed by changing the shape of impaction surface, the length of eyelid, and the number of eyelids of the grease filter. The flow field and particle trajectories in the grease filter with a flow chamber were simulated using the commercial code of STAR-CD. The difference of air velocity and pressure distributions among four models was discussed in detail. The collection efficiency curves and the pressure drops of four models were also compared. It was found that the grease filter model with flat top surfaces shows highest performance among four models, having high particle collection efficiency and relatively low pressure drop. The cutoff diameter of this model representing 50-% collection efficiency is about 7.1 ${\mu}{\textrm}{m}$ for water droplets at 100 m$^3$/h.

Semantic Access Path Generation in Web Information Management (웹 정보의 관리에 있어서 의미적 접근경로의 형성에 관한 연구)

  • Lee, Wookey
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.2
    • /
    • pp.51-56
    • /
    • 2003
  • The structuring of Web information supports a strong user side viewpoint that a user wants his/her own needs on snooping a specific Web site. Not only the depth first algorithm or the breadth-first algorithm, but also the Web information is abstracted to a hierarchical structure. A prototype system is suggested in order to visualize and to represent a semantic significance. As a motivating example, the Web test site is suggested and analyzed with respect to several keywords. As a future research, the Web site model should be extended to the whole WWW and an accurate assessment function needs to be devised by which several suggested models should be evaluated.

  • PDF

A Study on Fire Risk Assessment of a Small Space using Fire Simulation (시뮬레이션 분석을 통한 소규모 공간 화재위험성 평가에 관한 연구)

  • Ham, Eun-Gu;Kim, Dong-Cheol;Roh, Sam-Kew;Lee, Chang-Woo;Ko, Jae-Sun
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.341-344
    • /
    • 2015
  • 본 논문에서는 소규모 공간을 규정하였다. 광의의 소규모 공간이란 바닥 면적이 $300m^2$ 미만으로서 소방관련법 상 소화설비 설치대상에서 제외되는 공간에 해당한다. 또한 협의의 개념으로 소방관련법 상 소화설비 설치대상에 해당하나 바닥 면적이 $300m^2$ 미만 중에 소화설비 설치가 제외되는 공간과 피트공간과 그 밖의 소방관련법 상 소화설비 설치대상에 포함되지 아니하는 주방을 의미한다. 소규모 공간이지만 사용 용도가 창고 등과 겸용으로 사용되어 화재하중을 예상하기 어려우며 소화설비가 요구되는 공간이다. 본 연구는 다양한 화재원인 중에 전기화재에 관한 것으로 전기설비의 안전성능 기준이 강화되고 제품의 질적 수준이 향상됨에 따라 발화요인별 화재 발생률이 다소 둔화되고 있으나 전기화재는 여전히 화재사고의 상당한 부분을 차지하고 있는 실정으로 소규모에서 발생할 수 있는 화재를 대상으로 하여 구획된 소공간유형의 EPS실에서 케이블 등의 가연성물질에 대한 화재위험성을 시뮬레이션 분석을 통하여 산정하였다.

  • PDF

The Usefulness of Diffusion-weighted MR Imaging for Differentiation between Degenerative Spines and Infectious Spondylitis (퇴행성 척추와 감염성 척추염의 감별에 있어서 확산강조영상의 유용성)

  • 박원규;변우목;최준혁
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.152-157
    • /
    • 2002
  • Purpose : The differential diagnosis between Modic type I degenerative spine and infectious spondylitis sometimes is difficult, because the affected bone marrows in both disease show similar signal intensity on conventional MR imaging. We evaluate the usefulness of diffusion-wighted MR imaging for differential diagnosis between Modic type I degenerative spine and infectious spondylitis. Materials and methods : The spin-echo and diffusion-weighted MR images of eight patients with Modic type I degenerative spines and 14 patients with infectious spondylitis diagnosed by clinical findings or CT-guided biopsies we re analyzed. The diffusion-weighted imaging sequence was based on reversed fast imaging with steady-state precession (PSIF). Signal intensity changes of the vertebral bone marrow on conventional spin-echo and diffusion-weighted MR imaging were compared between degenerative spine and infectious spondylitis. Results : On T1-weighte d images, the affeted bone marrow in both disease showed hypointense signals. On T 2-weighted images, all of type I degenerative spine and 11 of infectious spondylitis showed hyperintensity, and three of infectious spondylitis showed heterogeneo us mixed signal intensity. On diffusion-weighted MR images, all of type I degenerative spine were hypointense with peripheral high signal intensity to normal vertebral body, but infectious spondylitis was hyperintense (n = 11) and hypointense (n=3). Conclusion : Diffusion-weighted MR imaging is useful to differentiate Modic type I degenerative spine from infectious spondylitis. On diffusion-weighted images, the high singal intensity of bone marrow suggests infectious spondylitis, whereas the low signal intensity of bone marrow with peripheral focal high signal intensity suggests type I degenerative spine.

  • PDF

A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain (유도공기 및 에어커튼을 이용한 주방 레인지후드 성능 개선에 관한 수치모사)

  • Sohn, Deok-Young;Lim, Ji-Hong;Choi, Yun-Ho;Park, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.321-327
    • /
    • 2007
  • In an apartment house that is generally air-tight and well insulated, the combustion gas from cooking devices is the major source of air pollution in the kitchen. It spreads throughout the house affecting the overall Indoor all quality. In this study, the performance of the kitchen range hood which employs air induction and air curtain was investigated by numerical simulation. The results are compared with that of two other kitchen range hoods which are in general use. The two general types of range hoods considered in the present calculations are box and plate type range hoods. The former has a large capture space between the filter and suction duct, while the latter has little. It was found that the capture efficiency of the kitchen range hood with air induction and air curtain Is higher than that of the general types of range hoods by 20% approximately The reason may be because the air induction and the air curtain block the air stream escaping from the front and the side part of range hoods effectively and because an additional fan for air induction and air curtain increases suction flow rates.