• Title/Summary/Keyword: 주기적안전성평가

Search Result 243, Processing Time 0.043 seconds

Application of Eddy Current Sensor for Measurement of TBM Disc Cutter Wear (TBM 디스크커터의 마모량 측정을 위한 와전류센서의 적용 연구)

  • Min-Sung Park;Min-Seok Ju;Jung-Joo Kim;Hoyoung Jeong
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.534-546
    • /
    • 2023
  • If the disc cutter is excessively worn or damaged, it becomes incapable of rotating and efficiently cutting rockmass. Therefore, it is important to appropriately manage the replacement cycle of the disc cutter based on its degree of wear. In general, the replacement cycle is determined based on the results of manual inspection. However, the manual measurements has issues related to worker safety and may lead to inaccurate measurement results. For these reasons, some foreign countries are developing the real-time measurement system of disc cutter wear by using different sensors. The ultrasonic sensors, eddy current sensors, magnetic sensors, and others are utilized for measuring the wear amount of disc cutters. In this study, the applicability of eddy current sensors for real-time measurement of wear amount in TBM disc cutters was evaluated. The distance measurement accuracy of the eddy current sensor was assessed through laboratory tests. In particular, the accuracy of eddy-current sensor was evaluated in various environmental conditions within the cutterhead chamber. In addition, the measurement accuracy of the eddy current sensor was validated using a 17-inch disc cutter.

The Evaluation of Usefulness of Two Times Elution a Day of $^{99m}Tc$ Using $^{99}Mo$-$^{99m}Tc$ Generator ($^{99m}Tc$ 발생기의 24시간 내 2회 용출의 유용성 평가)

  • Kim, Jeong-Ho;Seo, Han-Kyung;Jeong, Yeong-Hwan;Kim, Yeong-Su;Kim, Byung-Cheol;Gwon, Yong-Ju;Lee, Jeong-Ok;Park, Yeong-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.83-86
    • /
    • 2010
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo$-$^{99m}Tc$ generator (generator) is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. Therefore we have tried to seek the new method which could run generator to increase activity of $^{99m}Tc$ in this study. Materials and Methods: The $^{99m}Tc$ activity obtained from 5 times elution for 5 days from Monday to Friday using two generators was compared with 10 times elution. Appearance test, pH test, LAL test, sterility test, chemical impurity(Al) test, radio chemical purity test, ratio of $^{99}Mo$/$^{99m}Tc$ activity test have been done to check the stability of $^{99m}Tc$ eluting from generator respectively. Results: The $^{99m}Tc$ activity obtained from 5 times elution for 5 days was 168.2 GBq (4545 mCi) and 10 times was 230.5 GBq (6230 mCi). All quality control tests were within normal limit. Conclusion: We got to know that 2 times elution a day obtained more $^{99m}Tc$ activity than one time elution in this study.

  • PDF

Performance Analysis of Routing Protocols for WLAN Mesh Networks (WLAN Mesh 망을 위한 라우팅 기법의 성능 분석)

  • Park, Jae-Sung;Lim, Yu-Jin;Ahn, Sang-Hyun
    • The KIPS Transactions:PartC
    • /
    • v.14C no.5
    • /
    • pp.417-424
    • /
    • 2007
  • Mesh networks using WLAN technology have been paid attention as a key wireless access technology. However, many technical issues still exist for its successful deployment. One of those issues is the routing problem that addresses the path setup through a WLAN mesh network for the data exchanges between a station and a wired network. Since the characteristics of a WLAN mesh network can be very dynamic, the use of single routing protocol would not fit for all environments whether it is reactive or proactive. Therefore, it is required to develop an adaptive routing protocol that modifies itself according to the changes in the network parameters. As a logical first step for the development, an analytical model considering all the dynamic features of a WLAN mesh network is required to evaluate the performance of a reactive and a proactive routing scheme. In this paper, we propose an analytical model that makes us scrutinize the impact of the network and station parameters on the performance of each routing protocol. Our model includes the size of a mesh network, the density of stations, mobility of stations. and the duration of network topology change. We applied our model to the AODV that is a representative reactive routing protocol and DSDV that is a representative proactive routing protocol to analyze the tradeoff between AODV and DSDV in dynamic network environments. Our model is expected to help developing an adaptive routing protocol for a WLAN mesh network.

Microbiological Safety Evaluation on Ice Cream and Ice Pop Products (빙과류의 품목별 제품의 미생물학적 안전성 평가)

  • Yu, Jeong-Wan;Kim, So-Hyun;Hong, Dong-Lee;Kim, Hyeon-Jae;Jeong, Eun-Joo;Lee, Jae-Hwa;Yang, Ji-Young;Lee, Yang-Bong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.4
    • /
    • pp.367-373
    • /
    • 2019
  • In order to evaluate the microbiological safety of ice cream products, the total viable bacterial counts were measured in 6 kinds of ice pops, 5 kinds of non-milk fat ice cream, and 5 kinds of milk fat ice cream, sold in local markets. In addition, E. coli, S. aureus, B. cereus, and L. monocytogenes were artificially inoculated in three types of ice cream products and stored at $-5^{\circ}C$, $-10^{\circ}C$, and $-18^{\circ}C$, respectively, and after inoculation, viable cells were measured periodically. As a result of the total viable count, about 1~2 log CFU/mL was detected in 16 kinds of ice cream products. As a result of inoculation with microorganisms at various temperatures, the number of viable cells decreased as the storage period became longer, and the higher the storage temperature, the faster the microorganisms died. Especially, the microorganisms were killed faster in the ice pop products than in the other ice cream products, and the microorganisms were killed relatively slower in the milk ice cream. L. monocytogenes and S. aureus were relatively stable in frozen conditions compared to other microorganisms. The microbial contamination of commercial ice cream was lower than the allowable standard of the Korean Food Code. Microorganisms did not proliferate when the microorganism was inoculated at freezing temperature. Therefore, it is expected that the microbiological safety of frozen foods will be ensured if the sanitary control and disinfection of raw materials are thoroughly carried out during the production of frozen confections and the temperature control during distribution and storage is well maintained.

A Study on the Characteristics of Motion Response of Stern Trawlers in Following Seas (선미식 트롤선의 추파중 선체동요특성에 관한 연구)

  • Kang, Il-Kwon;Park, Byung-Soo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.226-233
    • /
    • 2002
  • In the field of research of sea keeping quality, much development has been made in recent years using the method of calculation based on the strip theory. It is very important to investigate the hull response of a fishing vessel in waves to ensure the safe navigation and fishing operation in rough seas by preserving excellent sea keeping qualities. For this purpose, the author measured various responses of three fishing vessels in waves using real sea experimental measuring system and analyzed the experimental data The results obtained can be summarized as follow. 1. The amplitudes of pitching motion in the experiments appeared low values with more than one peak occasionally in following sea and quartering sea, and the band width of those was found to be wide relatively. 2. The amplitudes of rolling motion in the experiments appeared high values with only one peak in following sea and quartering sea regardless of ship's tonnage, and the band width of those was found to be narrow relatively. 3. The comparisions of theoretical results with those of experiments for the pitching motions and rolling motion in following sea and quartering sea show that the theoretical values are higher slightly than those of experiments in both directions and the period at which the peak appears in the calculations and the experiments has good agreement approximately 4. The calculated responses of two vessels under a assumed wave of 2.2m height and 5.0sec period showed that the response of pitching motion of ship-A are 2.2 times bigger than those of ship-C in following sea and quartering sea, and the response of rolling motion of ship-A is 4.2 times bigger than that of ship-C in quartering sea.

Coupled Finite Element Analysis of Partially Saturated Soil Slope Stability (유한요소 연계해석을 이용한 불포화 토사사면 안전성 평가)

  • Kim, Jae-Hong;Lim, Jae-Seong;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.35-45
    • /
    • 2014
  • Limit equilibrium methods of slope stability analysis have been widely adopted mainly due to their simplicity and applicability. However, the conventional methods may not give reliable and convincing results for various geological conditions such as nonhomogeneous and anisotropic soils. Also, they do not take into account soil slope history nor the initial state of stress, for example excavation or fill placement. In contrast to the limit equilibrium analysis, the analysis of deformation and stress distribution by finite element method can deal with the complex loading sequence and the growth of inelastic zone with time. This paper proposes a technique to determine the critical slip surface as well as to calculate the factor of safety for shallow failure on partially saturated soil slope. Based on the effective stress field in finite element analysis, all stresses are estimated at each Gaussian point of elements. The search strategy for a noncircular critical slip surface along weak points is appropriate for rainfall-induced shallow slope failure. The change of unit weight by seepage force has an effect on the horizontal and vertical displacements on the soil slope. The Drucker-Prager failure criterion was adopted for stress-strain relation to calculate coupling hydraulic and mechanical behavior of the partially saturated soil slope.

An Approach to Risk Assessment of City Gas Pipeline (도시가스 배관의 위험평가 방법론 제시)

  • Park Kyo-Shik;Lee Jin-Han;Jo Young-Do;Park Jin-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.33-40
    • /
    • 2003
  • In this work, a novel approach was introduced to assess cost of loss resulting from risk as well as to help deciding inspection period through quantifying risk. In order to quantifying risk of city gas pipeline, frequency and consequence analysis were required. The main causes of city gas accident were analyzed to be digging, external corrosion, ground movement, and equipment failure. Tools to evaluate frequency of each cause was also suggested. Among city gas accidents, fire damage is the dominant one and mainly discussed; fatality, burning injury, and damage to building were estimated using the consequence model suggested. By combining frequency and consequence analysis, evaluating cost of risk management together with calculating example. This work could be applicable for city gas companies to plan how to manage risk most effectively.

  • PDF

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

A Study on the Reliability Analysis and Risk Assessment of Liquefied Natural Gas Supply Utilities (천연가스 공급설비에 대한 기기신뢰도 분석 및 위험성 평가)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.8-20
    • /
    • 2003
  • Natural gas has been supplied through underground pipelines and valve stations as a new city gas in Seoul. In contrast to its handiness the natural gas has very substantial hazards due to fires and explosions occurring from careless treatments or malfunctions of the transporting system. The main objectives of this study are to identify major hazards and to perform risk assessments after assessing reliabilities of the composing units in dealing with typical pipeline networks. there-fore two method, fault tree analysis ;1nd event tree analysis, are used here. Random valve stations are selected and considered its situation in location. The value of small leakage, large rupture, and no supply of liquefied natural gas is estimated as that of top event. By this calculation the values of small leakage are 3.29 in I)C valve station, 1.41 in DS valve station, those of large rup-lure are $1.90Times10_{-2}$ in DC valve station, $2.32$\times$10^{-2}$ in DS valve station, and those of no supply of LNG to civil gas company are $2.33$\times$10 ^{-2}$ , $2.89$\times$10^{-2}$ in each valve station. And through minimal cut set we can find the parts that is important and should be more important in overall system. In DC valve station one line must be added between basic event 26,27 because the potential hazard of these parts is the highest value. If it is added the failure rate of no supply of LNG is reduced to one fourth. In DS valve station the failure rate of basic event 4 is 92eye of no supply of LNG. Therefore if the portion of this part is reduced (one line added) the total failure rate can be decreased to one tenth. This analytical study on the risk assessment is very useful to prepare emergency actions or procedures in case of gas accidents around underground pipeline networks and to establish a resolute gas safety management system for loss prevention in Seoul metropolitan area.

A Design of Secure Electronic Health Information Management Protocol in the Internet of Things Environment (사물 인터넷 환경에서 안전한 전자의료정보 관리 프로토콜 설계)

  • Park, Jeong Hyo;Kim, Nak Hyun;Jung, Yong Hoon;Jun, Moon Seog
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.10
    • /
    • pp.323-328
    • /
    • 2014
  • ZigBee based on the most vulnerable part of u-Healthcare system that uses the ZigBee communication is the wireless section. ZigBee communication sectors to identify vulnerabilities in this paper, we propose to compensate. ZigBee has been raised from the existing vulnerabilities organize and ZigBee also uses the 64bit address that uniquely identifies a vulnerability that was defined as exposure. And to prevent the exposure of a unique identifying address was used to address a temporary identification. ZigBee security services, the proposed system during the Network Key for encryption only use one mechanism of Residential Mode is used. Residential Mode on all nodes of the entire network because they use a common key, the key is stolen, your network's security system at a time are at risk of collapse. Therefore, in order to guard against these risks to the security policy Network Key updated periodically depending on the method used to. The proposed evaluation and comparative analysis of the system were exposed in the existing system can hide the address that uniquely identifies a public key Network Key also updated periodically, so that leaks can occur due to reduced risk.