• Title/Summary/Keyword: 주기기

Search Result 2,374, Processing Time 0.032 seconds

Effect of Flavopiridol on Radiation-induced Apoptosis of Human Laryngeal and Lung Cancer Cells (후두암 및 폐암 세포주에서 Flavopiridol이 방사선에 의한 아포토시스에 미치는 영향)

  • Kim, Su-Zy;Kwon, Eun-Kyung;Lee, Seung-Hee;Park, Hye-Jin;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.227-232
    • /
    • 2007
  • Purpose: To investigate the flavopiridol effect on radiation-induced apoptosis and expression of apoptosisrelated genes of human laryngeal and lung cancer cells. Materials and Methods: A human laryngeal cancer cell line, AMC-HN3 and a human lung cancer cell line, NCI-H460, were used in the study. The cells were divided into four groups according to the type of treatment: 1) control groups; 2) cells that were only irradiated; 3) cells treated only with flavopiridol; 4) cells treated with flavopiridol and radiation simultaneously. The cells were irradiated with 10 Gy of X-rays using a 4 MV linear accelerator. Flavopiridol was administered to the media at a concentration of 100 nM for 24 hours. We compared the fraction of apoptotic cells of each group 24 hours after the initiation of treatment. The fraction of apoptotic cells was detected by measurement of the sub-G1 fractions from a flow cytometric analysis. The expression of apoptosis-regulating genes, including cleaved caspase-3, cleaved PARP (poly (ADP-ribose) polymerase), p53, p21, cyclin D1, and phosphorylated Akt (protein kinase B) were analyzed by Western blotting. Results: The sub-G1 fraction of cells was significantly increased in the combination treatment group, as compared to cells exposed to radiation alone or flavopiridol alone. Western blotting also showed an increased expression of cleaved caspase-3 and cleaved PARP expression in cells of the combination treatment group, as compared with cells exposed to radiation alone or flavopiridol alone. Treatment with flavopiridol down regulated cyclin 01 expression of both cell lines but its effect on p53 and p21 expression was different according to each individual cell line. Flavopiridol did not affect the expression of phophorylated Akt in both cell lines. Conclusion: Treatment with flavopiridol increased radiation-induced apoptosis of both the human laryngeal and lung cancer cell lines. Flavopiridol effects on p53 and p21 expression were different according to the individual cell line and it did not affect Akt activation of both cell lines.

Effect of PLA2 Inhibitor Rutin on Endotoxin-Induced Acute Lung Injury (내독소로 유도된 급성폐손상에서 PLA2의 억제제인 Rutin의 효과)

  • Kim, Seong-Eun;Lee, Young-Man;Park, Won-Hark
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.31-42
    • /
    • 2004
  • Acute respiratory distress syndrome (ARDS) is a kind of acute lung injury characterized by inflammatory disruption of alveolar-capillary barrier and notorious for its high mortality. Neutrophils cause cell damage through the production of free radicals, inflammatory mediators, and proteases in ARDS. $PLA_2$ might serve a primary regulatory role in the activation of neutrophils. This present study was performed to elucidate the effect of rutin known as $PLA_2$ inhibitor on ARDS induced by endotoxin. Endotoxin had increased lung myeloperoxidase (MPO) activity, BAL (bronchoalveolar lavage) protein content, numbers of neutrophils in BALF (bronchoalveolar lavage fluid) compared with those of control rat (p<0.001). In addition, histological evidence of lung injury was correlated with neutrophil influx into alveolar space and cerrous perhydroxide granules were found in lining of endothelial cell, alveolar type I, II cells. In contrast, pretreated group of rutin had significantly decreased all of the parameters (p<0.001). These data suggest that inhibition of $PLA_2$ is one step approach that block the process of ARDS. Accordingly, we conclude that rutin can be used as the prophylactic agent for ARDS on the bases of these experimental results.

Early Surgical Revascularization for Acute Myocardial Infarction (급성 심근 경색후 관상 동맥 우회술의 조기 적용)

  • 지현근;이원용
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1077-1082
    • /
    • 1997
  • To assess the early results, risk factors and optimal timing for coronary artery bypass graft surgery(CABG) after an acute myocardial infarction(AMI), we reviewed our 19 patients who underwent CABG within 30 days after AMI, between June 1994 and October 1996. This study excluded 1 patient whose diagnosis was AMI with ventricular septal rupture. 14 of the patients were male and 5 were female. Their ages ranged from 41 to 77 years(mean age, 60.6$\pm$ 10.4 years), and the amount of time between AMI and CABG ranged from 8 hours to 24 days(mean time, 10.6$\pm$6.4 days). There were 11 anteroseptal infarctions and 8 inferior wall infarctions. 11 patients had trsnsmural infarctions and 8 had subendocardial infarctions. Indications of operations were p imary revascularization and postinfarction angina. Three patients required preoperative intra-aortic balloon pump(IABP) support, and 4 additional patients required IABP to be separated from cardiopulmonary bypass. An average of 3.6 $\pm$ 0.6 vessels per patient were bypassed. The early mortality rate for these 19 patients was 5.3% and late mortality rate was 5.5%, 1-year and 2-year actuarial survival rates were 89.5% Univariate analysis of mortality showed that an ejection fraction less than 30% and intraopretative IABP supports were associated with risk factors(p value=0.018 and 0.015 respectively). Age, sex, time to CABG, emergency operations, types and locations of infarctions were not significant. Although our studies have weak p.oints in that there was only a small number of patients and the lack of long-term results, we could conclude that early myocardial revascularization is relatively safe after AMI for those individuals with an ejection fraction greater than 30%.

  • PDF

Evaluation of the testicular toxicity caused by 2-bromopropane in rats (랫드에 있어서 2-bromopropane에 의해 유발된 정소독성의 평가)

  • Kim, Jong-choon;Lee, Hyun-sook;Yun, Hyo-in;Chung, Moon-koo
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.2
    • /
    • pp.361-371
    • /
    • 2000
  • It has been recently reported that 2-bromopropane (2-BP) induces male reproductive toxicity in both human and experimental animals. However, delayed effects of 2-BP on male reproductive system have not been investigated in detail. The present study was conducted to investigate the testicular toxicity of 2-BP and to determine the recovery of normal spermatogenesis in Sprague-Dawley rats. Male rats aged 5 weeks were administered 1,000mg/kg 2-BP by gavage daily for 4 weeks and sacrificed sequentially at 1, 2, 3, 4 and 12 weeks after initiation of 2-BP treatment. Testicular toxicity was evaluated qualitatively by histopathological examinations and quantitatively by reproductive organ weights, spermatid head count, and repopulation index. In the 2-BP treated rats, the body weights was significantly suppressed and the weights of testes and epididymides were also decreased in a time-dependent manner. On histopathological examination, spermatogonia in stages I-VI and preleptotene and leptotene spermatocytes in stages VII-IX were strongly depleted at 1 week of dosing. Spermatogonia were depleted extensively in all spermatogenic stages at 2 weeks. Continuing with the evolution of spermatogenic cycle, zygotene spermatocytes, pachytene spermatocytes, and round spermatids were sequentially depleted at 2, 3, and 4 weeks of dosing due to the depletion of their precursor cells. Vacuolization of Sertoli cells and spermatid retention were also observed at all time points, suggesting that 2-BP induced Sertoli cell dysfunction. At 12 weeks, after 8 weeks recovery, most of the tubules appeared severely atrophic and were lined by Sertoli cells only. Leydig cell hyperplasia in the interstitial tissue was also found. In addition, dramatic reductions in the number of spermatid heads and repopulation index were observed, indicating that 2-BP-induced testicular injury is irreversible. These results indicate that 4 weeks repeated-dose of 1,000mg/kg 2-BP results in a progressive germ cell loss due to the depletion of spermatogonia followed by long-term testicular atrophy in SD rats.

  • PDF

Differences in the Soundscape Characteristics of a Natural Park and an Urban Park (자연공원과 도시공원의 Soundscape 특성 차이)

  • Gim, Ji-youn;Lee, Jae-Yoon;Ki, Kyong-Seok
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.1
    • /
    • pp.112-118
    • /
    • 2017
  • The purpose of this study is to clarify the characteristics of the soundscape in a natural park and an urban park. The study sites were a natural park (Chiaksan Nationalpark) and an urban park (Rose Park) in Wonju City, Gangwon Province. Soundscape recording was conducted using Digital Recorder from April 2015 to January 2016. The analysis period was 8 days per season, with a total of 64 days (2 places). Analysis items were soundscape's daily cycle, soundscape type, and seasonal variation. According to the result of the daily cycle analysis of the soundscape, the natural park was dominated by the biophony in accordance with the cycle of the sun, and the airplane sound was observed in the daytime. Meanwhile, anthrophony was consistently produced in the urban park 24 hours a day. As a result of the detailed type analysis of the soundscape, the sources of biophony were classified into wild birds, mammals, insects and amphibians, and the sources of geophony were classified into rain and wind. The anthrophony was mostly airplane sound. In the urban park, wild birds appeared to most influence the biophonic sounds while rain and the wind were the most frequent sounds that contribute to geophony. The most influential components of anthrophony in the urban park were in the order of automobiles, people, music, construction, cleaning, and airplane sound. As a result of the seasonal difference analysis of the soundscape, it was statistically significant that the natural park shows higher biophony in spring, summer, and autumn compared to the urban park. Anthrophony in the urban park appeared to be higher than the natural park in all seasons. The significance of this study is that it is the first study to identify the characteristics of the soundscape of a natural park and an urban park emanating from different landscapes in South Korea.

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times (호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Woong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • The gated RapidArc may produce a dosimetric error due to the stop-and-go motion of heavy gantry which can misalign the gantry restart position and reduce the accuracy of important factors in RapidArc delivery such as MLC movement and gantry speed. In this study, the effect of stop-and-go motion in gated RapidArc was analyzed with varying gating window time, which determines the total number of stop-and-go motions. Total 10 RapidArc plans for treatment of liver cancer were prepared. The RPM gating system and the moving phantom were used to set up the accurate gating window time. Two different delivery quality assurance (DQA) plans were created for each RapidArc plan. One is the portal dosimetry plan and the other is MapCHECK2 plan. The respiratory cycle was set to 4 sec and DQA plans were delivered with three different gating conditions: no gating, 1-sec gating window, and 2-sec gating window. The error between calculated dose and measured dose was evaluated based on the pass rate calculated using the gamma evaluation method with 3%/3 mm criteria. The average pass rates in the portal dosimetry plans were $98.72{\pm}0.82%$, $94.91{\pm}1.64%$, and $98.23{\pm}0.97%$ for no gating, 1-sec gating, and 2-sec gating, respectively. The average pass rates in MapCHECK2 plans were $97.80{\pm}0.91%$, $95.38{\pm}1.31%$, and $97.50{\pm}0.96%$ for no gating, 1-sec gating, and 2-sec gating, respectively. We verified that the dosimetric accuracy of gated RapidArc increases as gating window time increases and efforts should be made to increase gating window time during the RapidArc treatment process.

Report on the External Audits Conducted by Korean Society of Medical Physics (한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고)

  • Huh, Hyun Do;Cho, Kwang Hwan;Cho, Sam Ju;Choi, Sang Hyoun;Kim, Dong Wook;Hwang, Ui-Jung;Kim, Ki Hwan;Min, Chul Kee;Choi, Tae Jin;Oh, Young Kee;Lee, Seoung Jun;Park, Dahl;Park, Sung-Kwang;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • The aim of this work is to verify the self-quality assurances in medical institutions in Korea through the external audits by the group of experts and have a mutual discussion of the systematic problems. In order to validate the external audits 30 of 80 medical institutions across the nation were picked out considering the regional distribution and the final 25 institutions applied voluntarily to take part in this work. The basic rules were setup that any information of the participants be kept secrete and the measurements be performed with the dosimetry system already verified through intercomparision. The outputs for 2 or more photon beams, the accuracy of gantry rotation and collimator rotation and the poistional accuracy of MLC movement were measured. The findings for the output measurement showed the differences of -0.8%~4.5%, -0.79%~3.01%, and -0.7%~0.07% with respect to that of the verified dosimetry system for the 6MV, 10MV, and 15MV, respectively. For the reference absorbed dose 8 (16%) of 50 photon beams in 25 medical institutions differed 2.0% or greater from the reference value. The coincidences of Field size with x-ray beam and radiation isocenters of Gantry roration and collimator rotation gave the results of within ${\pm}2$ mm for every institute except 2 institutions. The positional accuracy of MLC movement agreed to within ${\pm}1$ mm for every institute. For the beam qualities of 6 MV photon beams kQ values showed the distribution within 0.4% between maximum and minimum. For the protocols 21 institutions (84%) used absorbed dose to water based protocol while 4 insitutions (16%) used air kerma based one. 22 institutions employed the SSD technique while 3 institutions did the SAD one. External audit plays an important role in discovering the systematic problems of self-performing Quality Assurances and having in depth discussion for mutual complementation. Training experts of international level as well as national support system are required so that both the group of experts of medical physicists and government laboratory could perform together periodical and constant external audits.

Design of Thermo-optic Switch with Low Power Consumption by Electrode Optimization (전극 구조의 최적화를 통한 저전력 열광학 스위치 설계)

  • Choi, Chul-Hyun;Kong, Chang-Kyeng;Lee, Min-Woo;Sung, Jun-Ho;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.266-271
    • /
    • 2009
  • We designed a thermo-optic switch based on a directional coupler with not only a high extinction ratio but also significantly low power consumption. The switch operates by using the thermo-optic effect of the polymer which the refractive index changes by heating the electrode. If the electrode is not powered (OFF), the input light will be coupled completely to the other waveguide. When the electrode is powered at a certain level (ON), input light launched into the input waveguide will remain in that waveguide due to the lower index adjusted in the other waveguide. The switch based on the directional coupler was designed using the generalized extinction ratio curve and the lateral shift of the input waveguide. The coupling length is 1,610 ${\mu}m$ and the extinction ratios are -28 and -30 dB for ON and OFF states, respectively. The electrode structures were optimized by thermal analysis. The transported heat into the waveguide is increased, as the electrode width (w) is increased and the center distance between the electrode and the waveguide (d) is decreased. Also, because the heat generated in the electrode affects the other waveguide, the temperature difference between two waveguides is varied as the given w and d. There are specific conditions which have the maximum of the temperature difference. That of the temperature difference is increased as the width and the temperature of the electrode are increased. Especially, when the switch is designed using the condition with the maximum of the temperature difference for switching, the temperature of the electrode can be decreased. We expect this condition will be the novel method for the reduction of the power consumption in a thermo-optic switch.

Effect of Rainwater Sprinkling System Utilization for Reducing Heat Stress in Milking Cows during Intense Heat Time (폭염시 착유우 고온스트레스 경감을 위한 빗물관수시스템 이용 효과)

  • Choi, Dong-Yoon;Cho, Sung-Back;Park, Kyu-Hyun;Yang, Seong-Hak;Hwang, Ok-Hwa;Kwag, Jung-Hoon;Jeong, Kwang-Hwa;Song, Jun-Ik;Yoo, Yong-Hee;Ahn, Hee-Kwon
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.21-28
    • /
    • 2012
  • Since the temperature during summer is higher than the temperature which is suitable for milking cows, high temperature stress have severely affected dairy farmers due to decreased milk production. This study was carried out to investigate the effect of rainwater sprinkling system for reducing heat stress in milking cows during intense heat time. Treatment conditions were divided into 2 types ; No rainwater sprinkling (T1) and Rainwater sprinkling (T2). Temperature in the milking cow shed, feed intake, milk yield, respiration rate and rectal temperature were measured to investigate the effect of hot environment on the physiological, productive responses in milkig cows. The results obtained are summarized as follows : The daily milk yields were 24.5 and 27.4 kg per head in T1 and T2 during experimental period. The respiration rate was significantly higher in T1 than those of T2. The rectal temperature in T1 ($40.6^{\circ}C$) was higher than those of T2 ($39.8^{\circ}C$). It was suggested that rainwater sprinkling system installed in the dairy cow shed was effective means to reduce heat stress of milking cow.

Analysis of the Characteristics of Water Quality Difference Occurring between High Tide and Low Tide in Masan Bay (만조와 간조시 마산만 수질의 농도차 발생 특성의 분석)

  • Yoo, Youngjin;Kim, Sung Jae
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.102-113
    • /
    • 2019
  • Slack-tide sampling was carried out at 6 stations at high and low tide for a tidal cycle during spring tide of the early summer (June) and summer (July, August) of 2016 to determine the difference of water quality according to tide in Masan Bay, Korea. The mixing regime of all the water quality components investigated was well explained through the correlation with SAL. In the early summer and summer, TURB, DSi and NNN which mainly flow into the bay from the streams and SS, COD, AMN and $H_2S$ which mainly indicate the internal sink and source materials have a property of conservative mixing and non-conservative mixing, respectively. The conservative mixing showed a good linear relationship of the water quality between high and low tide, and the non-conservative mixing showed a variation of different pattern each other. Factor analysis performed on the concentration difference data sets between high and low tide helped in identifying the principal latent variables for them. In early summer, multiple effects (tidal action, natural influx and internal sinks and sources etc.) acted in combination for the differences to be distributed evenly in four factors (VF1~4), since there were few allochthonous inputs as a low-water season. On the contrary, in summer, the parameters showing large concentration difference at ST-1 affected by stream water were concentrated in one factor (VF1) and clearly distinguished from the parameters affected by the internal sinks and sources. In fact, there is no estuary (bay) that always maintains steady state flow conditions. The mixing regime of an estuary might be changed at any time due to the change of flushing time, and furthermore the change of end-member conditions due to the internal sinks and sources makes the occurrence of concentration difference inevitable. Therefore, when investigating the water quality of the estuary, it is necessary to take a sampling method considering the tide to obtain average water quality data.