• Title/Summary/Keyword: 주광

Search Result 122, Processing Time 0.022 seconds

Analysis of Simulation of Daylight and Experiment for Determining on Effective Dimming Ratio (효과적인 조광제어시스템 적용을 위한 주광시뮬레이션과 실험데이터 분석)

  • Kim, Ga-Young;Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • This study proposes to increase the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing daylight incident. A photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, received a proper dimming signal from DCU. Generally it is effective to control artificial lighting with the different control ratio of each zone by setting a photosensor as same number and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. As a result of grasping the distribution of daylight previously and analyzing daylight and dimming data, we can dim different dimming ratios to each zone of artificial lighting by a single photosensor.

Calibration Mirror Mechanism with Fail-Safe Function (결함안전 기능을 고려한 교정 반사경 구동장치)

  • Lee, Kyong-Min;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.7
    • /
    • pp.682-687
    • /
    • 2011
  • Calibration mirror mechanism has been widely used for on-board calibration with black body. The calibration mirror is deployed to reflect the radiation energy from the black body to the image sensor for calibrating the sensor system. After the calibration, the calibration mirror is stowed not to hide a main optical path. It also has a fail-safe function which can stow the mirror by just removing the input power of motor when the calibration mirror is stopped at certain position during the calibration. In the present work, the operation concept, design, torque analysis and functional test results of the calibration mirror mechanism with the aforementioned function have been introduced and investigated.

A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System (소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구)

  • 김한성;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2003
  • This paper presents field measurements on daylighting and electric lighting with dimming controlled systems for a small office in Seoul, Korea. And the main purpose of this study is to provide the evaluation data of lighting energy performance when a dimming system is installed. For the performance evaluation, the mock-up room(3.6x7.2x2.6[m]) was used for the actual test. The results of this study were as follows; 1) The correlation between daylight illuminance at a workplane(Ed) and the photosensor signal(Sd) was an important factor affecting the performance of daylight responsive dimming system, 2) The mock-up office space gained a sufficient workplace illuminance of 579[lux] with the dimming control system 3) About 53[%J of monthly lighting energy could be saved using the dimming control system.

Application of Sun Control Devices and Energy Conservation (Theory and Practice) (주광제어 장치를 이용한 건물의 에너지 절약(이론 및 실제))

  • Han, Hyun-Joo;Cho, Yil-Sik;Song, In-Choon
    • Solar Energy
    • /
    • v.10 no.2
    • /
    • pp.77-85
    • /
    • 1990
  • In the present analysis, a number of sun control devices are examined for their performance in promoting the interior visual environment. Two exemplary cases are introduced for their excellence in harnessing the concept of daylighting and passive concepts. Of these, the Johnson Controls branch office building in Salt Lake City manifests the effectiveness of light shelves and clerestory windows in implementing these concepts. Distinct optical characteristics are found for overhangs, light shelves, louvers, and blinds as they interfere with the path of sunlight. Substantial amount of energy could be saved if the fundamentals of these devices are truly understood in their application to residential and commercial buildings. Sustained efforts should be made in this regard by the builders, architects, energy consultants, and educators who make contributions in energy management.

  • PDF

The prediction of reduction ranges of daylight illuminance in small office for sky and shading conditions (천공 및 차양조건에 따른 소규모 사무실의 주광 조도 감소범위 예측)

  • Jang, Seo Yeon
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.33-41
    • /
    • 2019
  • This study examines the distributions of daylight illuminance in a small office space under clear and cloudy sky conditions. Three shading conditions using Venetian blinds were applied for the analysis of daylight illuminance. Computer simulations using the Lightscacpe were conducted for the daylight conditions applied to the office space. Results indicate that the illuminance differences between clear and cloudy sky for south-facing conditions were greater than those for north-facing conditions. The differences in December and June were the greatest and smallest, respectively. For the north-facing conditions, the daylight illuminance at 10:00, 12:00 and 14:00 in June and September under the cloudy sky was higher than those under the clear sky conditions. For all daylight conditions, the biggest amount of illuminance reduction occurred when the shading device conditions were changed from the no blind to the 45 degree blinds. As the distance from window increased, the shading effect that occurred when the shading device conditions were changed from the horizontal blind to the 45 degree blinds increased.

Evaluation on the Characteristics of Daylight Distributions of Grating Louver System in a Pair Glass by Computer Simulation (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.1-9
    • /
    • 2009
  • A recent research trend on the Daylight Responsive Dimming Systems, using available daylight for energy savings, is to integrate automated roller shading systems and venetian blind systems which are vertically controlling daylight to indoor based on sun profile angle. Therefore, this paper suggests Grating Louver System into a pair glass as a new shading system, which can control daylight vertically and horizontally. The optimized spacing of louvers, which is to block direct sunlight into a space, was calculated. And then, the system was simulated for analysis and evaluation of characteristics of daylight by Desktop Radiance 2.0.

Proposal of the Prediction Equation for Interior Daylight Illuminance (실내 주광조도 분포 예측식의 제안 및 검증)

  • Park, Woong-Kyu;Park, Tae-Ju;Kang, Gyu-Min;Lee, Sang-Yup;Song, Doosam
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.114-123
    • /
    • 2013
  • In these days, most of the office buildings are being required to save energy for maintenance. lighting system constitutes 20% to 30% of the total annual electrical energy consumption in office buildings. As an energy saving strategy for lighting system, dimming control system based on illuminance sensors came into use. But the system is accompanied with many illuminance sensors to control lighting and needs a lot of initial investment. In this study, the prediction equation for indoor daylighting illuminance distribution is proposed through the review for conventional research results and field measurements. The proposed equation was verified by the comparison between predicted results and field measurement results. The developed prediction equation for daylighting can be used to control the indoor illuminance level with the limited sensor when dimming control system is operated.