• 제목/요약/키워드: 좌심실 보조장치

검색결과 40건 처리시간 0.029초

좌심실보조장치 수술 환자의 드레싱 방법에 따른 드라이브라인 감염 실태 (Driveline Infections Incidence According to Dressing Methods for Patients with Left Ventricular Assist Device Implantation)

  • 최남경;최수정;최지연;박선희
    • 임상간호연구
    • /
    • 제28권2호
    • /
    • pp.167-176
    • /
    • 2022
  • Purpose: Driveline infection (DLI) is one of the major adverse events of Left Ventricular Assist Device (LVAD). The purpose of this study was to explore the incidence of DLI according to the driveline dressing methods. Methods: This study was a retrospective cohort study that investigated the medical records of 75 patients who implanted LVAD from January 2015 to December 2020 at a hospital in Seoul, Korea. Traditionally, sandwich dressing method was applied until October 2019, after which newly winded dressing method was adopted for driveline dressing to LVAD patients. The outcome variables were compared between sandwich dressing method applied group (n=41) and winded dressing method applied group (n=34). The follow-up period for DLI was 1 year. Results: When compared participants' characteristics, there was no difference between the two groups, except the type of LVAD device. The incidence of DLI was 17.1% in sandwich dressing group, while no infection was found in winded dressing group (p=.011). Conclusion: Although there were difference in the LVAD devices, it is considered that winded dressing contributed to the reduction of DLI. Further research on standardized dressing methods was required for DLI prevention in Korea.

관상동맥 폐동맥 이상 기시증의 외과적 치료 후 좌심실 및 승모판 기능의 변화 (Changes of Ventricular Function and Mitral Regurgitation after Repair of Anomalous Origin of Coronary Artery from the Pulmonary Artery)

  • 이정렬;오세진;김웅한;김용진;노준량;배은정;노정일;윤용수
    • Journal of Chest Surgery
    • /
    • 제38권8호
    • /
    • pp.523-528
    • /
    • 2005
  • 배경: 좌관상동맥 폐동맥 이상 기시증의 수술적 치료 후 좌심실 기능 및 승모판 폐쇄부전의 변화 양상을 분석하고자 하였다. 대상 및 방법: 1986년 4월부터 2002년 7월까지 12명의 환자가 좌관상동맥 폐동맥 이상 기시증으로 외과 교정을 받았다. 연령의 중앙값은 4개월이었고 10명의 환자가 관상동맥 전이술을, 1명이 Takeuchi수술, 1명이 복재정맥을 이용한 관상동맥 우회술을 시행 받았다. 승모판 성형술은 1명에서 동시에 시행하였고 나머지 모든 환자들에서 승모판 폐쇄부전의 정도와 관계없이 승모판에 대한 성형술 및 치환술을 하지 않았다. 결과: 수술로 인한 조기사망은 2명$(16.7\%)$이었으며 평균 추적관찰 기간은 $7.1\pm4.14년(7개월$\sim$13년)이었다. 4명의 환자에서 수술 후 $2.2\pm1.1$일의 순환 보조가 필요하였고 그 중 좌심실 보조 장치를 사용한 경우가 1명 있었다. 수술 후 좌심실 단축율은 $17.7\pm9.6\%$에서 $33.4\pm9.1\%$으로 증가하였고(p<0.05) 좌심실 이완기말 직경의 평균값은 $41.8\pm7.0\;mm에서 $33.1\pm7.3\;mm로(p<0.05), 수축기말 직경의 평균값은 $33.4\pm7.9\;mm에서 $22.2\pm7.5 \;mm로(p<0.05) 각각 감소하였다. 수술 전 승모판 폐쇄부전은 생존 환자 모두에서 수술 후 1년째 시행한 심초음파 검사상호전이 관찰되었고, 이후 4년 추적관찰 도중에도 점진적으로 호전되었다. 추적관찰 도중 2명의 환자가 재수술을 받았는데 수술 후 3도 이상의 승모판 페쇄부전이 남아 승모판 성형술을 시행하거나 Takeuchi수술을 받은 환자에서 우심실 유출로 협착으로 인해 재수술하였다. 걸론: 좌관상동맥 폐동맥 이상 기시증은 수술적 교정, 특히 관상동맥 전이술을 시행한 경우 훌륭한 단기 및 장기 성적을 보였으며 좌심실 기능 및 승모판 페쇄부전증의 개선을 확인할 수 있었다. 그러나 승모판 폐쇄부전에 대한 동반 수술 적응증에 대한 지표는 지속적으로 탐색해야 할 것이다

동물실험을 통한 공압식 좌심실보조장치의 평가 (Evaluation of Pneumatic Left Ventricular Assist Device for Animal Experiment)

  • 이혁수;오혜정;이상훈;김삼현;서필원;박성식;이계한;안혁;황승옥
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.235-236
    • /
    • 1998
  • The purpose of this paper is to develop diaphragm type pneumatic Left Ventricular Assist Device(LVAD) for clinical application and to evaluate its performance through the mock circulation and animal experiment. The blood housing and diaphragm are made by polyurethane. The relations of cardiac output us. beat rate and cardiac output vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. We performed animal experiment and 4 animals survived more than 24hrs. As a result, the hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

좌심실보조장치의 출구 캐뉼라의 삽관 위치에 따른 혈액관류에 대한 시뮬레이션 연구 (Simulation Study of Blood Perfusion according to Outflow Cannulation Site of Left Ventricular Assist Device)

  • 지인혁;김형균;임기무
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.135-142
    • /
    • 2015
  • Outflow cannulation site of left ventricular assist device(LVAD) chosen by considering anatomical structure of thoracic cavity and vascular system. Though outflow cannulation site influences blood perfusion at each branch, there is no standard rule or quantitative data. In this study, we computed the amount of blood perfusion at each arterial branch numerically according to outflow cannulation sites(ascending aorta, aortic arch, descending aorta). We generated computational meshes to the three-dimensionally reconstructed arterial system. Clinically measured arterial pressure were used for inlet boundary condition, porous media were applied to mimic blood flow resistance. Blood perfusion through left common carotid artery was 2.5 times higher than other cases, and that through right common carotid artery was 1.1 times higher than other branches. Although this is simulation study, will be useful reference data for the clinical study of LVAD which considers blood perfusion efficiency.

적응 학습방식의 신경망을 이용한 좌심실보조장치의 모델링 (Adaptively Trained Artificial Neural Network Identification of Left Ventricular Assist Device)

  • 김상현;김훈모;류정우
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.387-394
    • /
    • 1996
  • This paper presents a Neural Network Identification(NNI) method for modeling of highly complicated nonlinear and time varing human system with a pneumatically driven mock circulatory system of Left Ventricular Assist Device(LVAD). This system consists of electronic circuits and pneumatic driving circuits. The initiation of systole and the pumping duration can be determined by the computer program. The line pressure from a pressure transducer inserted in the pneumatic line was recorded System modeling is completed using the adaptively trained backpropagation learning algorithms with input variables, heart rate(HR), systole-diastole rate(SDR), which can vary state of system. Output parameters are preload, afterload which indicate the systemic dynamic characteristics. Consequently, the neural network shows good approximation of nonlinearity, and characteristics of left Ventricular Assist Device. Our results show that the neural network leads to a significant improvement in the modeling of highly nonlinear Left Ventricular Assist Device.

  • PDF

좌심실보조장치의 혈액주머니용 코팅재료로서 PU-PEO-SO3의 in vivo 혈액적합성에 관한 연구 (In Vivo Blood Compatibility of PU-PEO-SO3 as Coating Material for Blood Sac of Left Ventricular Assist Device ( LVAD))

  • 한동근;김종원
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권1호
    • /
    • pp.19-26
    • /
    • 1994
  • Sulfonated poly (ethyleneoxide)-grafted polyurethane (PU-PEO-$SO_3$) prepared by bulk modification was coated on a blood sac for electrohydraulic left ventricular assist device (ELVAD) implanted in dogs and its in vivo blood compatibility on shear stress was studied as compared with untreated Po. The effect of the wall shear stress on the protein adsorption unlike platelet adhesion is dependent on the surface characteristics of the material, although less proteins seem to be adsorbed in the region of the high shear stress. The thickness of total proteins adsorbed on PU-PEO-SOJ (400 ${\AA}$) by trans¬mission electron microscopy(TEM) was considerably lower than that of untreated PU(l,000~1,600 ${\AA}$), but PU-PEO-$SO_3$ showed high albumin adsorption, low fibrinogen and IgG adsorption, and low platelet adhesion as compared with untreated PU, suggesting that PU-PEO-$SO_3$ is more in vivo blood compatible. Therefore, it appears that such a blood compatible PU-PEO-$SO_3$ is useful for blood contacting biomaterials including artificial organs.

  • PDF

관상동맥 우회술의 조기성적 (Early Result of Coronary Artery Bypass Surgery)

  • 박재형;이원용;김응중;홍기우
    • Journal of Chest Surgery
    • /
    • 제30권2호
    • /
    • pp.158-163
    • /
    • 1997
  • 한림대학교 의료원 강등성심 병원에서는 1994년 7월 처음으로 관상동맥 우회술을 시행한 이래 1995 년 8월까지 총 48례의 관상동맥 우회술을 시행하였다. 이 중 응급상황하에서 수술을 시행한 10례와 좌 주관상동맥 성형술을 시행한 6례를 제외한 32례의 조기 성적을 추적하였다. 남녀비는 14:18이었고, 나이는 37~81세였다. 환자들의 특징은 32명 중 26명이 불안정형 협심증, 6명이 안정성 협심증이었고, 이 들 중 9명에서 심근 경색증의 기왕력이 있었다. 5명에서 좌심실 박출계수가 40% 이하로 좌심실 기능이 떨어져 있었고 만성신부전증 환자가 1명 있었다. 관상동맥 위험인자는 흡연, 고혈압, 고지방혈증, 당뇨, 비만 등이 었고, 관상동맥의 협착 정도는 세 혈관질환이 21례, 두혈관 질환이 7례, 한혈관질환이 2례, 좌주 관상동맥 질환이 2례였다. 수술은 온혈심정지액으로 심정지 유도후, 냉혈심정지액을 관상정맥동을 통해 지속적으로 관류시켰으며, 대동맥 차단시간은 평균 105분(66~183분)이었고, 총 심폐관류시간은 평 f 242.4분(119~852분)이었다. 이식혈관은 1례를 제외하고는 모든 환자에서 내유동맥을 사용하였고, 2례에서 요골동맥을 사용하였으\ulcorner, 나머지 이식편은 대복재정 맥을 사용하였다. 사용된 총이식편수는 103개로 환자당 3.22개였고, 총 이식편의 32%에서 동맥 이식편을 사용하였다. 수술 후 4례 에서 저심박출증으로 IABP를 사용하였고, 술 후 심근경색은 2례에서 발생하였다. 그외의 합병증으로는 호흡부전, 부정맥, 종격동염, 출혈, 뇌혈관경 색 등이었다. 술후 2례에서 사망하여 조기 사망률은 6.25%였으며, 1례는 저심박출증으로심폐기의 이탈이 안되어, 1례는 심근경색증으로 양심실 보조장치 제거후 67일만에 사망하였다. 추적관찰중 2례에서 흉통이 재발하여 관상동맥 조영술 시행결과, 7개의 이식편 중 2개에서 폐색(우판상동맥으로의 이식편) 이 보였으나, 투약으로 통증은 호전되었고, 1례에서 술후 3달만에 갑자기 심정지가 발생하여 사망하였다.

  • PDF

요골동맥을 이용한 관상동맥우회술 -조기성적 (Coronary Artery Bypass Surgery with Radial Artery -Early Results)

  • 나찬영;이영탁;박국양;이해영;김욱성;박?현;홍민수;심재천;권오춘
    • Journal of Chest Surgery
    • /
    • 제30권3호
    • /
    • pp.275-281
    • /
    • 1997
  • 요골동맥을 이용한 관상동맥 우회 술은 1970년대초 처음 도입되었으나 요골동맥 연축(spasm)에 의한 이식편의 부전으로 사용이 중지되었으나, 1980년대 후반 칼슘 길항제등 새로운 연축 방지제의 개발과 요골동맥 채취방법(harvesting technique)의 개선으로 다시 사용하게 되었다. 저자들은 1994년 10월부터 1995년 7월까지 총 36례에서 요골동맥 자유이식 편을 이용하륵 관상동맥우 회술을 시행하였다. 이들중 34례에서 좌측 내흉동맥을 동시에 사용하였으며 15례(42%)에서는 모든 이 식편을 동맥이식 편으로 사용하였다. 총 123개의 원위부 문합중(환자당 평균 3.4개) 좌측 내흉동맥을 사용한 문합이 36개,복재정맥을 이용한 문합이 23개였으며 나머지 64개의 윈위부 문합은 요골동맥을 사 용하였고(환자당 평균 1.8개), 요골동맥을 이용한 문합이 전체문합수의 52%를 차지하였다. 요골동맥이 식편의 원위부 문합장소는 좌측회선지(circunflex artery)가 38개, 사선지(diagonal artery)가 18개, 우측 관상동맥이 6개, 좌전하행 지(left anterior descending artery)가 2개로 분포하였다. 요골동맥을 하나의 이 식편으로 사용한 경우가 10례, 순차적문합으로 사용 \ulcorner경우가25례 및 두개의 이식 편으로 나누어 사용 한 경우가 1례였다. 관상동맥 우회 술과 동반된 수술로는 관상동맥 내막절제술이 14례, 관상동맥 포편성 형술(patch angioplasy)이 4례, 승모판막 재건술이 1례, 심근경색후 심실중격파열 봉합술이 1례였다. 수 술후 합병증으로는 요골동맥을 채취한 측의 엄지손가락 감각이상이 2례, 술후 출혈이 1례,저심박출증 으로 좌심실보조장치 1례등이 있었으며 이중 좌심실보조장치를 시행한 1례에서 사망하였다. 조기추적 관상동맥 조영술은 생존한 35례중 11례(31%)에서 수술후 79일에서 210일(평균 126일)에 시행하여 좌측 내흉동맥 및 복재정맥은 100%, 요골동맥은 95%의 개방률을 보였다. 생존한 환자 모두에서 협심증의 재 발은 없었다. 결론적으로 본 연구에서는 아직 증례의 부족과 짧은 추적기간으로 요골동맥 이식편의 우 월성은 입증할 수 없으나 단기적으로 만족할만한 것으로 향후 더 많은 경험의 축적과 장기적 인 추적이 요할 것으로 사료된다.

  • PDF

인공신경망을 이용한 기계식 판막의 생체외 모의 혈전현상 검출 (In-Vitro Thrombosis Detection of Mechanical Valve using Artificial Neural Network)

  • 이혁수;이상훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.429-438
    • /
    • 1997
  • 기계식 판막은 매몰식 인공장기에 널리 사용돼 왔으며, 판막의 이상은 환자의 죽음으르 의미한다. 판막의 이상에 영향을 미치는 것은 많은 요소들이 있는데 대표적으로 기계적인 고장과 혈전현상이 있다. 그래서 비침습적으로 이것들을 발견하는 것이 필요하게 된 것이다. 이 논문의 목적은 스펙트럼의 해석과 인공신경망을 이용하여 혈전현상을 발견하는데 있다. 신호의 측정은 공압식 좌심실 보조장치에 장착한 기계식 판막으로부터 마이크로폰과 증폭기를 이용하였다. 디스크 위의 모의 혈전현상과 봉합링의 주위에 혈전현상, 20%, 40% 60%로 자라나는 혈전현상은 펠레세인과 실리콘을 이용하여 제작하였다. 기초 성능 평가를 위해 1KHz 정현파를 인가하여 시스템을 평가하였으며, 정상적인 판막과 5 종류의 혈전현상의 스펙트럼은 혈전현상의 정보를 지닌 개폐시 peak의 신호 파형에서 구하였다. 데이터의 정량적인 해석을 위해 7,000개의 입력 노드와 20개의 은닉층과 1개의 출력층으로 이루어진 인공신경망을 사용하였다. 결론적으로 훈련된 인공신경망을 사용한 결과 정상 판막과 비정상 판막을 판단하는데 90%의 판단능력을 보였다. 이상의 실험을 통해 판막의 이상유무를 신호의 스펙트럼 해석과 인공신경망을 통해 평가할수 있음을 알 수 있었다. 본 논문의 결과는 앞으로 인공장기를 몸속에 지니고 있는 환자에게서 장기의 상태를 지속적으로 감시할 수 있는 기술적 토대를 제공할 것이다.

  • PDF

동물실험을 통한 전기유압식 좌심실 보조장치의 성능 평가 (Evaluation of Electrohydraulic Left Ventricular Assist Device through Animal Experiment)

  • 최재순;정찬일;최원우;박성근;조영호;엄경식;이종진;원용순;김희찬;김원곤;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.84-87
    • /
    • 1996
  • We have been developed electrohydraulic left ventricular assist device and done various in vivo evaluation on the device. Through the in vivo experiment conducted from Jan. 23, 1996 to Feb. 8, we could have experience of long-term evaluation fur the first time. The sheep used in this experiment had survived for 16 days. We used new actuator with reduced size and linear motion guide replacing oil box and ball bearings. Also, we used improved blood chamber with reduced size, reduced weight facilitating fixing the chamber to animal's body, and polymer sac having improved folding pattern. Against suction problem, we used absolute pressure limiter only. Motor current for driving this new actuator was not much higher than older one. Effective stroke volume was about 48 cc. Thrombosis was found around top area and peripheral boundary of the sac and valves. There was no sign of damage from suction problem in the atrium observed at autopsy. Main cause of death was presumed to be progressive formation of thrombosis in the cannulae. In this paper, the results of this experiment are documented.

  • PDF