• Title/Summary/Keyword: 종파

Search Result 126, Processing Time 0.028 seconds

Detection of Hydride Blisters in Zirconium Pressure Tubes using Ultrasonic Mode Conversion and Velocity Ratio Method (초음파 모드 변환 및 속도비 방법에 의한 지르코늄 압력관의 수소화물 블리스터 탐지)

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Young-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.334-341
    • /
    • 2003
  • When the pressure tubes(f are in contact with the calandria tube(CT) in the pressurized heavy water reactor(PHWR), the temperature difference between inner and outer wall of W results in a thermal diffusion of hydrogen (deuterium) and hydride blisters are formed on the outer surface of PT. Because the hydride blisters and zirconium matrix are acoustically continuous, it is not easy to distinguish the blisters from the matrix with conventional ultrasonic method. An ultrasonic velocity ratio method was developed to detect small hydride blisters on the zirconium pressure tube. Hydride blisters were grown in the PT specimen using a steady state thermal diffusion device. The flight times of longitudinal echo and reflected shear echo from the outer surface were measured accurately. The velocity ratio of the longitudinal wave to the shear wave was calculated and displayed using contour plot. Compared to the conventional flight time method of longitudinal wave, the velocity ratio method shows superior sensitivity to detect smaller blisters as well as better images for the blister shapes. Detectable limit of the outer shape of the hydride blisters was conservatively estimated as $500{\mu}m$, with the same specifications of ultrasonic transducer used in the actual PHWR pressure tube inspection.

Seismic Studies on Ground Motion using the Multicomponent Complex Trace Analysis Method (다성분 복소 트레이스 분석법을 이용한 지진파 입자운동 연구)

  • Lee, So-Young;Kim, Ki-Young;Kim, Han-Joon
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.37-48
    • /
    • 2000
  • In order to investigate in-line ground motions caused by earthquakes, we examine the multicomponent complex trace analysis method (MCTAM) for the synthetic data and apply it to real earthquake data. An experimental result for synthetic data gives correct information on the arrival times, duration of individual phases, and approaching angles for body waves. Rayleigh waves are also easily identified with the MCTAM. A deep earthquake with magnitude of 7.3 was chosen to test various polarization attributes of ground motions. For P waves, instantaneous phase difference between the vertical and the in-line horizontal components ${\phi}(t)$, instantaneous reciprocal ellipticity ${\rho}(t)$, and approaching angle ${\tau}(t)$ are computed to be ${\pm}180^{\circ},\;0{\sim}0.25,\;and\;-30^{\circ}{\sim}-45^{\circ}$, respectively. For S waves, ${\phi}(t)$ tends to vary while ${\rho}(t)$ have values of $0{\sim}0.3\;and\;{\tau}(t)$ remains near vertical, respectively. A relatively low frequency signal registered just prior to the S wave event is interpreted as a P-wave phase based on its polarization characteristics. Velocities of P and S waves are computed to be 8.633 km/s and 4.762 km/s, and their raypath parameters 0.074 s/km and 0.197 s/km. Dynamic Poisson's ratio is obtained as 0.281 from the velocities of P and S waves.

  • PDF

Application of Laser Ultrasonic Technique for Nondestructive Evaluation of Wall Thinning in Pipe (배관부 감육 손상의 비파괴 평가를 위한 레이저 초음파 기술 적용)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu;Yoon, Suk-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.361-367
    • /
    • 2013
  • Many of the nuclear power plant pipe is used in high temperature and high pressure environment. Wall thinning frequently caused by the corrosion. These wall thinning in pipe is expected gradually increase as nuclear power become superannuated. Therefore there is need to evaluate wall thinning in pipe and corrosion defect by non-destructive method to prevent the accident of the nuclear power facility due to pipe corrosion. Especially for real-time assessment of the wall thinning that occurs in nuclear power plant pipe, the laser ultrasonic technology can be measured even in hard-to-reach areas, beyond the limits of earlier existing contact methods. In this study, the optical method using laser was applied for non-destructive and non-contact evaluation. Ultrasonic signals was acquired through generating ultrasonic by pulse laser and using laser interferometer. First the ultrasonic signal was detected in no wall thinning in pipe, then a longitudinal wave velocity was measured inside of pipe. Artificial wall thinning specimen compared to 20, 30, 40 and 50% of thickness of the pipe was produced and the longitudinal wave velocity was measured. It was possible to evaluate quantitatively the wall thinning area(internal defect depth) cause it was able to calculate the thickness of each specimen using measured longitudinal wave velocity.

A Method for Noninvasive Diagnosis of Bone using Ultrasonic Doppler Method (초음파 Doppler법에 의한 생체 경조직의 비침투적인 진단을 위한 기초실험)

  • 박무훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.7
    • /
    • pp.3-11
    • /
    • 1998
  • 본 논문에서는 분포정수선로의 간단한 모델을 이용해서, 외부에서 진동을 가했을 때 에 뼈 표면에서 발생하는 굴곡파의 전파속도와 종파의 전파속도를 구할 수 있는 새로운 측 정원리를 제안했다. 이 측정원리를 이용해서, 봉(brass, polymethylmethacrylate)표면에 발생 하는 정재파에 대한 속도의 공간분포를 laser Doppler법으로 측정해서, 각각의 주파수에 대 한 전파속도를 구했다. 이 새로운 측정방법은 in vivo에서 초음파 Doppler법을 이용해서 뼈 의 이상(골다공증, osteoporosis)진단의 가능성을 제시했다.

  • PDF

Stress Evaluation by Measuring Ultrasonic Velocity (초음파 음속측정에 의한 응력평가에 관한 연구)

  • Lee, Bum-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.138-144
    • /
    • 1999
  • Longitudinal wave and shear wave velocity changes of PMMA Polymer meterial under the the unidirection load were measured. The Third-order elastic modulus and acousto-elastic modulus of PMMA are obtained. The theoretical and experemental values of the velocity change of each wave by stress are compared each other and the validity of theoretical expression is examinated.

  • PDF

A Study of the Detection for Underclad Cracks of Nuclear Pressure Vessel (원자력 압력용기의 피복하부 결함검출에 대한 고찰(II))

  • Park, C.S.;Kang, K.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.31-39
    • /
    • 1993
  • It has not been performed to inspect the underclad cracking of nuclear pressure vessel in Korea since there is no code requirements for inspection. However, underclad cracks in nuclear pressure vessels have been reported since the early 1970s. The aim of this experiment is to find the suitable ultrasonic inspection techniques for underclad cracking. The various transducers, for example $70_{\backprime}$ refracted longitudinal wave, 50/70 multibeam, SLIC-40, SLIC-50, are used in this investigation. Experiments on prescreening blocks and a demonstration block under the same condition as in the nuclear power pressure vessels show that the $70_{\backprime}$ refracted longitudinal wave method is the best one for the length evaluation and also gives a good signal pattern for detection of the crack, while the 50/70 multibeam transducer is more effective for the detection of underclad cracking. On the other hand, the SLIC-50 transducer using M-SPOT(Satellite Pulse Observation Technique) and M-PET (Peak-Echo Technique) methods is the most effective one for the depth of underclad crack estimation.

  • PDF

Ultrasonic Transducer Design for the Axial Flaw Detection of Dissimilar Metal Weld (이종금속 용접부 축방향 결함 검출을 위한 초음파 탐촉자 설계)

  • Yoon, Byung-Sik;Kim, Yong-Sik;Yang, Seung-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.536-542
    • /
    • 2011
  • Dissimilar metal welds in nuclear power plant are known as very susceptible to PWSCC flaws, and periodically inspected by the qualified inspector and qualified procedure during in-service inspection period. According to field survey data, the majority of their DMWs are located on tapered nozzle or adjacent to a tapered component. These types of configurations restrict examination access and also limit examination volume coverage. Additionally, circumferential scan for axially oriented flaw is very difficult to detect located on tapered surface because the transducer can't receive flaw response from reflector for miss-orientation. To overcome this miss-orientation, it is necessary adapt skewed ultrasonic transducer accomodate tapered surface. The skewed refracted longitudinal ultrasonic transducer designed by modeling and manufactured from the modelling result for axial flaw detection. Experimental results showed that the skewed refracted longitudinal ultrasonic transducer get higher flaw response than non-skewed refracted longitudinal ultrasonic transducer.

Effects of Depth-varying Compressional Wave Attenuation on Sound Propagation on a Sandy Bottom in Shallow Water (천해 사질 퇴적층에서 종파감쇠계수의 깊이별 변화가 음파손실에 미치는 영향)

  • Na, Young-Nam;Shim, Tae-Bo;Jurng, Moon-Sub;Choi, Jin-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2E
    • /
    • pp.76-82
    • /
    • 1994
  • The characteristics of bottom sediment may be able to vary within a few meters of depth in shallow water. Since bottom attenuation coefficient as well as sound velocity in the bottom layer is determined by the composition and characteristics of sediment itself, it is reasonable to assume that the bottom attenuation coefficient is accordingly variable with depth. In this study, we use a parabolic equation scheme to examine the effects of depth-varying compressional wave attenuation on acoustic wave propagation in the low frequency ranging from 100 to 805 Hz. The sea floor under consideration is sandy bottom where the water and the sediment depths are 40 meters and 10 meters, respectively. Depending on the assumption that attenuation coefficient is constant or depth-varying, the propagation loss difference is as large as 10dB within 15 km. The predicted propagation loss is very much comparable to the measured one when we employ a depth-varying attenuation coefficient.

  • PDF

Change in Ultrasonic Characteristics with Isothermal Heat Treatment of 2.25Cr-1Mo Steel (등온열처리에 따른 2.25Cr-1Mo강의 초음파 특성 변화)

  • Nam, Young-Hyun;Baek, Un-Bong;Park, Jong-Seo;Nahm, Seung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.353-358
    • /
    • 2013
  • The ultrasonic characteristics of 2.25Cr-1Mo steel were investigated in relation to the isothermal heat treatment temperature and time. Charpy impact tests and hardness tests were conducted on individual specimens with three different heat treatment conditions. A pulse-echo method with longitudinal waves was used to measure the attenuation and velocity of ultrasonic waves. The FATT (fracture appearance transition temperature) increased with an increase in the isothermal heat treatment time, which implies that the toughness decreased. As the isothermal heat treatment time and temperature increased, the longitudinal wave velocity and ultrasonic attenuation coefficient were raised.

Oblique Incidence Technique for Ultrasonic Nonlinear Characterization in SUS316L Alloy (SUS316L 강의 초음파 비선형 특성평가를 위한 경사입사기법)

  • Baek, Seung-Hyun;Lee, Tae-Hun;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.345-351
    • /
    • 2010
  • The oblique incidence technique for ultrasonic nonlinear characterization was studied in stainless steel 316L alloy subjected to high cycle fatigue. A dog-bone plate specimen was prepared to make different faitgue-driven deformation at each position where the stress concentration could occur in the middle of specimen. In addition to the normal transmission technique, the oblique incidence technique which is newly suggested in this study, was used to measure ultrasonic nonlinear parameter. The fatigued specimen shows higher ultrasonic nonlinear parameter than the virgin specimen for both techniques. Ultrasonic nonlinear parameter highly increases in the middle of test specimen where the stress concentration existes. Relative nonlinear parameter has strong correlation with fatigue damage. Consequently, the oblique incidence technique with longitudinal wave can be potential to characterize high cycle fatigue damage.