Tumor Motion Tracking during Radiation Treatment using Image Registration and Tumor Matching between Planning 4D MDCT and Treatment 4D CBCT (치료계획용 4D MDCT와 치료 시 획득한 4D CBCT간 영상정합 및 종양 매칭을 이용한 방사선 치료 시 종양 움직임 추적)

  • Jung, Julip;Hong, Helen
    • Journal of KIISE
    • /
    • v.43 no.3
    • /
    • pp.353-361
    • /
    • 2016
  • During image-guided radiation treatment of lung cancer patients, it is necessary to track the tumor motion because it can change during treatment as a consequence of respiratory motion and cardiac motion. In this paper, we propose a method for tracking the motion of the lung tumors based on the three-dimensional image information from planning 4D MDCT and treatment 4D CBCT images. First, to effectively track the tumor motion during treatment, the global motion of the tumor is estimated based on a tumor-specific motion model obtained from planning 4D MDCT images. Second, to increase the accuracy of the tumor motion tracking, the local motion of the tumor is estimated based on the structural information of the tumor from 4D CBCT images. To evaluate the performance of the proposed method, we estimated the tracking results of proposed method using digital phantom. The results show that the tumor localization error of local motion estimation is reduced by 45% as compared with that of global motion estimation.

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF

Evaluation on the Usefulness of Lung Tumor Stereotactic Radiosurgery Applying the CyberKnife $Synchrony^{TM}$ Respiratory Tracking System (사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치를 이용한 폐종양 방사선수술의 유용성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Choi, Jun-Gu;Chae, Hong-In
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.379-386
    • /
    • 2010
  • This study evaluated the motion of tumors during the entire period of therapy and the accuracy of radiosurgery among forty eight lung tumor patients who were underwent radiosurgery using the CyberKnife Synchrony Respiratory Tracking System. The motion of lung tumor was measured by the coordinates of a gold acupuncture needle inserted into the tumor or the area around the tumor using the CyberKnife image guided system. Then the accuracy of radiosurgery was evaluated based on the error of correlation computed with the motion tracking system. The lung tumor motion is Cranio-Caudal direction by an average of $2.63{\pm}1.87\;mm$, moved left-right direction by $1.13{\pm}0.71\;mm$, and anterior-posterior direction by $1.74{\pm}1.16\;mm$. The degree of rotational movement was $1.66{\pm}1.66^{\circ}$ on X axis, $1.20{\pm}0.97^{\circ}$ on Y axis, and $1.18{\pm}0.73^{\circ}$ on Z axis. The vector of translation movement was measured to be $3.78{\pm}2.00\;mm$ on the average. The results show that directions of Cranio-Caudal(p < 0.001), anterior-posterior direction(p < 0.029), and three dimensional vector value(p < 0.002) showed statistical significance, because the lower side of tumor showed more intensive movement compared to the upper side of tumor. The radiosurgery was carried out by compensating the motion of tumor after accurate investigation of the correlation error with the average of $0.95{\pm}0.62\;mm$ during the lung tumor radiosurgery with the CyberKnife Synchrony Respiratory Tracking System.

Management Strategy and Surveillance of Intraductal Papillary Mucinous Neoplasm-Gastroenterologist's Viewpoint (췌관 내 유두상 점액종양의 치료 전략과 추적 관찰-소화기내과의 관점)

  • Kim, Tae Hyeon;Chon, Hyung Ku
    • Journal of Digestive Cancer Reports
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • The length, the frequency, and the methods of surveillance for intraductal papillary mucinous neoplasm (IPMN) of the pancreas are still debating. According to the recent guidelines, IPMN is stratified into "high-risk stigmata" or absolute indication and "worrisome features" or relative indication as a guide in managing these patients, either those with resection of the lesion or those under surveillance. The risk of malignant transformation was quite low for branch duct-IPMNs without worrisome features or high risk stigmata. However, because the incidence rate of pancreatic cancer in these patients increase linearly with time, continued long-term surveillance is therefore important for patients with low-risk, as well as higher-risk, IPMN. Considering the high prevalence of malignancy, main duct-IPMN should be treated by surgical resection. Among patients with these type IPMNs, segmental dilatation of the main pancreatic duct without any mural nodules and larger than 10 mm of main pancreatic duct might not be immediately resected and need very careful examination and observation. The risk related to a major pancreatic resection must balance the risk of surveillance in patients with IPMN of the pancreas who have co-morbidity and are elderly.

Performance Evaluation of the Tumor Tracking Method Using Beam on/off Interface for the Treatment of Irregular Breathing (호흡이 불규칙한 환자의 치료를 위한 Beam on/off Interface를 이용한 종양 추적 치료 방법의 성능 평가)

  • Lee, Minsik
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.343-349
    • /
    • 2018
  • Dose rate regulated tracking is known to be an efficient method which adaptively delivers tracking treatments when patient breathing is irregular. The Motion Management Interface (MMI, Varian Medical System, CA), which provides beam on/off switching during treatment is available for clinic. Study is to test if delivering the adaptive tumor tracking is feasible for irregular breathing using beam switching with MMI. 55 free breathing RPM traces acquired from lung cancer patients are used. The first day RPM traces of the patients are utilized to design preprogrammed tracking MLC patterns, of which periods are intentionally reduced by 20% in order to catch up the variation of patient breathing irregularity in the treatment day. Eligibility criteria for this technique are the variation of amplitude and period less than 20%. An algorithm which determines beam on/off every 100 ms by considering the preprogrammed (MLC) positions and current breathing positions is developed. Tracking error and delivery efficacy are calculated by simulating the beam-switching adaptive tracking from the RPM traces. Breathing patterns of 38 patients (70%) met the eligibility criteria. Tracking errors of all of the cases who meet the criteria are less than 2 mm (average 1.4 mm) and the average delivery efficacy was 71%. Those of rest of the cases are 1.9 mm and 48%. Adaptive tracking with beam switching is feasible if patient selection is based on the eligibility criteria.

Thoracic Intramedullary Schwannoma Aggravated on Follow-up MRI: Case Report and Review of the Literature (추적 자기공명영상에서 악화된 흉추 척수내 신경집종: 증례보고 및 문헌고찰)

  • Lee, So-Yeon;Jee, Won-Hee;Kim, Sun-Ki;Jung, Chan-Kwon;Park, Chun-Kun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.207-212
    • /
    • 2009
  • Schwannoma is a rare intramedullary tumor. There has been no reported case about interval aggravation on follow-up MR imaging. We report initial and follow-up MR findings of a thoracic intramedullary schwannoma with syringomyelia and edema in a patient without neurofibromatosis. Intramedullary schwannoma should be included for differential diagnosis of intramedullary tumor even though followup MR imaging shows interval increase in size of the tumor and extent of associated edema to mimic malignancy.

  • PDF

Preliminary Results of Fractionated Stereotactic Radiotherapy for Benign Brain Tumors (양성 뇌종양에 대한 분할 정위 방사선치료의 예비 결과)

  • Choi, Byung-Ock;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 2003
  • Purpose : To evaluate the role of fractlonated sterotactic radiotherapy (FSRT) in the management of benign brain tumors, we reviewed the clinical, and radiographic responses of patients treated. Methods and Materials : Between March 1995 and March 2002, 36 patients with benign brain tumors were treated by FSRT. The pathological diagnoses consisted of pituitary adenomas (12 patients), cranio-pharyngiomas (5 patients), meningiomas (10 patients), and acoustic neurinomas (9 patients). Radiotherapy doses of 25 to 35 Gy (3~6 Gy/fraction, 5~10 fractions) were prescribed to the 85~90% isodose line, depending upon the location, size and volume of the tumors. The median clinical and radiographical follow up periods were 31 (range, 2~74) and 21 (range, 4~56) months, respectively. Results : In the 35 patients that could be evaluated for their clinical response, 13 (37.1%) were considered improved, 16 (45.7%) stable and 6 (17.2%) worse. Of the 33 patients who had radiographic studies, tumor shrinkage was noted in 17 (51.5%), tumor stabilization in 13 (39.4%), and tumor progression in 3 (9.1%). Of the 17 tumor shrinkage patients, 7 (21.2%) showed a complete response. Acute radiation-induced complications occurred iin 11 (30.6%) patients. Conclusions : FSRT is considered a safe and effective treatment method for begin brain tumors, but large numbers of patients, with relatively long follow-up periods are needed to assess the exact role or effect of FSRT.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.