• Title/Summary/Keyword: 좁은밴드

Search Result 56, Processing Time 0.027 seconds

Effects of Flight Conditions on IR Signature from Aircraft Exhaust Plume (비행조건에 따른 항공기 배기플룸의 IR 신호 특성)

  • Go, Gun-Yung;Kim, Man-Young;Baek, Seung-Wook
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.58-66
    • /
    • 2012
  • The IR signature and radiative base heating from an aircraft plume have been important factors for aircraft survivability in modern battle fields. In order to enhance the aircraft survivability and reduce the base heating, infrared signatures emitted from an aircraft exhaust plume should be determined. In this work, therefore, IR signatures and radiative base heating characteristics are examined in the plume exhausted from the aircraft with operating at altitude of 5 km in M=0.9 and 1.6, respectively. As a result, it is found that the particular wavelength IR signature has high spectral characteristics because of $H_2O$ and $CO_2$ gases in the plume, and the radiative heat flux coming into the base plane increases with higher Mach number and shorter distance.

Effects of Flight Conditions on IR Signature from Aircraft Exhaust Plume (비행조건에 따른 항공기 배기플룸의 IR 신호 특성)

  • Go, Gun-Yung;Kim, Man-Young;Baek, Seung-Wook
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.282-289
    • /
    • 2012
  • The IR Signature and radiative base heating from an aircraft plume have been important factors for aircraft survivability in modern battle fields. In order to enhance the aircraft survivability and reduce the base heating, infrared signatures emitted from an aircraft exhaust plume should be determined. In this work, therefore, IR signatures and radiative base heating characteristics are examined in the plume exhausted from the aircraft with operating at altitude of 5km in M=0.9 and 1.6, respectively. As a result, it is found that the particular wavelength IR signature has high spectral characteristics because of $H_2O$ and $CO_2$ gases in the plume, and the radiative heat flux coming into the base plane increases with higher Mach number and shorter distance.

  • PDF

Comparative Study on Hyperspectral and Satellite Image for the Estimation of Chlorophyll a Concentration on Coastal Areas (연안 해역의 클로로필 농도 추정을 위한 초분광 및 위성 클로로필 영상 비교 연구)

  • Shin, Jisun;Kim, Keunyong;Ryu, Joo-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.309-323
    • /
    • 2020
  • Estimation of chlorophyll a concentration (CHL) on coastal areas using remote sensing has been mostly performed through multi-spectral satellite image analysis. Recently, various studies using hyperspectral imagery have been attempted. In particular, airborne hyperspectral imagery is composed of hundreds of bands with a narrow band width and high spatial resolution, and thus may be more effective in coastal areas than estimation of CHL through conventional satellite image. In this study, comparative analysis of hyperspectral and satellite-based CHL images was performed to estimate CHL in coastal areas. As a result of analyzing CHL and seawater spectrum data obtained by field survey conducted on the south coast of Korea, the seawater spectrum with high CHL peaked near the wavelength bands of 570 and 680 nm. Using this spectral feature, a new band ratio of 570 / 490 nm for estimating CHL was proposed. Through regression analysis between band ratio and the measured CHL were generated new CHL empirical formula. Validation of new empirical formula using the measured CHL showed valid results, with R2 of 0.70, RMSE of 2.43 mg m-3, and mean bias of 3.46 mg m-3. As a result of applying the new empirical formula to hyperspectral and satellite images, the average RMSE between hyperspectral imagery and the measured CHL was 0.12 mg m-3, making it possible to estimate CHL with higher accuracy than multi-spectral satellite images. Through these results, it is expected that it is possible to provide more accurate and precise spatial distribution information of CHL in coastal areas by utilizing hyperspectral imagery.

The GOCI-II Early Mission Marine Fog Detection Products: Optical Characteristics and Verification (천리안 해양위성 2호(GOCI-II) 임무 초기 해무 탐지 산출: 해무의 광학적 특성 및 초기 검증)

  • Kim, Minsang;Park, Myung-Sook
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1317-1328
    • /
    • 2021
  • This study analyzes the early satellite mission marine fog detection results from Geostationary Ocean Color Imager-II (GOCI-II). We investigate optical characteristics of the GOCI-II spectral bands for marine fog between October 2020 and March 2021 during the overlapping mission period of Geostationary Ocean Color Imager (GOCI) and GOCI-II. For Rayleigh-corrected reflection (Rrc) at 412 nm band available for the input of the GOCI-II marine fog algorithm, the inter-comparison between GOCI and GOCI-II data showed a small Root Mean Square Error (RMSE) value (0.01) with a high correlation coefficient (0.988). Another input variable, Normalized Localization Standard (NLSD), also shows a reasonable correlation (0.798) between the GOCI and GOCI-II data with a small RMSE value (0.007). We also found distinctive optical characteristics between marine fog and clouds by the GOCI-II observations, showing the narrower distribution of all bands' Rrc values centered at high values for cloud compared to marine fog. The GOCI-II marine fog detection distribution for actual cases is similar to the GOCI but more detailed due to the improved spatial resolution from 500 m to 250 m. The validation with the automated synoptic observing system (ASOS) visibility data confirms the initial reliability of the GOCI-II marine fog detection. Also, it is expected to improve the performance of the GOCI-II marine fog detection algorithm by adding sufficient samples to verify stable performance, improving the post-processing process by replacing real-time available cloud input data and reducing false alarm by adding aerosol information.

The Study on Improving Accuracy of Land Cover Classification using Spectral Library of Hyperspectral Image (초분광영상의 분광라이브러리를 이용한 토지피복분류의 정확도 향상에 관한 연구)

  • Park, Jung-Seo;Seo, Jin-Jae;Go, Je-Woong;Cho, Gi-Sung
    • Journal of Cadastre & Land InformatiX
    • /
    • v.46 no.2
    • /
    • pp.239-251
    • /
    • 2016
  • Hyperspectral image is widely used for land cover classification because it has a number of narrow bands and allow each pixel to include much more information in comparison with previous multi-spectral image. However, Higher spectral resolution of hyperspectral image results in an increase in data volumes and a decrease in noise efficiency. SAM(Spectral Angle Mapping), a method based on vector inner product to compare spectrum distribution, is a highly valuable and popular way to analyze continuous spectrum of hyperspectral image. SAM is shown to be less accurate when it is used to analyze hyperspectral image for land cover classification using spectral library. this inaccuracy is due to the effects of atmosphere. We suggest a decision tree based method to compensate the defect and show that the method improved accuracy of land cover classification.

Visible Light Photocatalytic Properties of Bismuth Ferrite Prepared By Sol-Gel Method (졸-겔법으로 제조된 Bismuth ferrite의 가시광 광촉매 특성)

  • Park, Byung-Geon;Chung, Kyong-Hwan
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.486-492
    • /
    • 2020
  • The method for preparing a perovskite-type bismuth ferrite (BFO) photocatalyst which reacts to visible LED light and the characteristics of visible light photocatalysis were investigated. BFO was prepared according to the sol-gel method. The prepared BFO consisted mainly of BiFeO3 structure and formed a nano-sized crystal including Bi24Fe2O39 structure. The BFO nano crystallines were identified from the UV-visible diffuse reflectance spectra to absorb UV and visible light up to about 600 nm. The bandgap of the BFO determined from the diffuse reflectance spectrum was about 2.2 eV. Formaldehyde was decomposed by the photoreaction of BFO photocatalysts with the visible light LED lamps with wavelengths of 585 nm and 613 nm. The narrow bandgap of BFO led to elicit BFO photocatalytic activity in visible LED light.

Synthesis and Optical Properties of $YNbO_4:RE^{3+}$ (RE=Eu, Dy) Phosphors

  • Park, Seong-Jun;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.174.1-174.1
    • /
    • 2013
  • 최근에 우수한 광학적 특성과 높은 화학적 안정성을 갖는 적황색 형광체 개발에 많은 노력이 경주되고 있다. 본 연구에서는 고상반응법을 사용하여 모체 결정 $YNbO_4$$Eu^{3+}$$Dy^{3+}$이온의 농도를 각각 체계적으로 치환 고용하여 발광 효율이 높은 적색과 황색 형광체를 제조하였다. 특히, $Eu^{3+}$$Dy^{3+}$이온의 농도를 달리하여 합성한 형광체 분말의 결정구조, 표면형상, 흡광과 발광 스펙트럼을 비교 분석하여 최적의 이온 농도를 조사하였다. 합성된 형광체 분말의 회절상은 $Eu^{3+}$$Dy^{3+}$이온의 함량비에 관계없이 모든 형광체 분말 시료는 약 $28,6^{\circ}$ 에서 최대값을 갖는 (021)면에서 발생하였고, 형광체 분말은 JCPDS #72-2077에 제시된 회절상과 일치하는 단사정계 결정 구조임을 확인 하였다. $Dy^{3+}$이온의 함량비가 0.01 mol에서 주 회절 피크의 세기는 최대이었으며, 함량비가 더욱 증가함에 따라 회절 피크의 세기는 점점 감소하였다. 이에 반하여, $Eu^{3+}$가 도핑된 형광체는 함량비가 0.15 mol일때 최대 회절피크가 관측되었다. $Dy^{3+}$이온이 도핑된 $YNbO_4$ 형광체의 경우에 두 종류의 흡광 스펙트럼이 관측되었다. 첫째는 약 267 nm를 피크로 하여 230~300 nm 영역에 걸쳐 폭넓게 분포하는 흡광 스펙트럼이고, 두 번째는 약 356, 393, 456 nm에 피크를 갖는 상대적으로 세기가 약하고 밴드폭이 좁은 흡광 스펙트럼이 관측되었다. $Eu^{3+}$이온이 도핑된 형광체 분말의 주 흡광 스펙트럼은 약 270 nm에 피크를 갖는 폭넓게 분포하는 전하전달 밴드이었다. $YNbO_4$ 형광체 분말의 발광 스펙트럼은 $Eu^{3+}$이온이 도핑된 경우에 620 nm에 강한 세기를 갖는 적색 발광이 관측되었고, $Dy^{3+}$이온이 도핑된 경우에는 580 nm에 최대 발광세기를 갖는 황색 발광 스펙트럼이 나타났다.

  • PDF

High Resolution Reconstruction of EO-1 Hyperion Hyperspectral Images Using IKONOS Images (IKONOS 영상을 이용한 EO-1 Hyperion Hyperspectral 영상자료의 고해상도 구축)

  • Lee, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.631-639
    • /
    • 2008
  • This study presents an approach to synthesize hyperspectral images of lower resolution at a higher resolution using the high resolution images acquired from a sensor of commercial satellites. The proposed method was applied to the reconstruction of EO-1 Hyperion images using the images acquired from IKONOS sensor. Based on the FitPAN-Mod pansharpening technique (Lee, 2008b), the hyperspectral images of 30m resolution were reconstructed at 1m resolution of IKONOS panchromatic image. In this study, the synthesized hyperspectral images of 50 bands, whose wavelengths range in the wavelength of panchromatic sensor, were generated from the three stages of high resolution reconstruction using FitPAN-Mod. The experimental results show that the proposed method effectively integrates the spatial detail of the panchromatic modality as well as the spectral detail of the hyperspectral one into the synthesized image. It indicates the proposed method has a potential as a technique to produce alternative images for the images that would have been observed from a hyperspectral sensor at the high resolution of commercial satellite images.

Luminescence Properties of YTa7O19 doped with Tm3+ (Tm3+ 도핑에 따른 YTa7O19의 형광특성)

  • Ryu, Hojin;Park, Hee-Dong
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.637-639
    • /
    • 1997
  • Samples of $YTa_7O_{19}$ doped with $Tm^{3+}$ were prepared using the solid state reaction method to investigate their photoluminescence characteristics. The samples were identified by XRD and SEM, and the optical measurement was also carried out. Under 359 nm excitation, $YTa_7O_{19}$ doped with $Tm^{3+}$ exhibited a narrow-band blue emission, at about 455 nm. The maximum emission intensity was obtained at $YTa_7O_{19}$ doped with 0.12 mole $Tm^{3+}$. This revealed the concentration quenching of emission intensity.

  • PDF

Quantum Dot Sensitized Photocatalyst by Plasma Immersion Ion Implantation (접수번호 : E-P02플라즈마 이온주입을 통한 양자점 감응형 광촉매)

  • Choe, Jin-Yeong;Park, Won-Ung;Jeon, Jun-Hong;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.390-390
    • /
    • 2011
  • 급속한 산업의 발달은 심각한 환경오염 및 에너지 문제를 가져왔다. 이를 해결하기 위하여 무한한 에너지원인 태양에너지를 원천으로 하는 친환경 정화소재로서의 광촉매(photocatalyst)를 통하여 인류의 에너지를 확보하는 것에 대한 관심이 급격하게 증가하고 있는 추세이다. 현재 광촉매로 가장 많이 사용되는 $TiO_2$의 경우 뛰어난 광활성에도 불구하고, 상대적으로 넓은 밴드갭(band gap) 으로 인한 가시광 응답성의 부재로 이를 해결하기 위한 많은 연구가 진행되고 있다. 따라서 본 연구에서는 PIII&D (plasma immersion ion implantation & deposition) 장비를 통하여 -60 kV의 펄스 고전압을 인가해 $TiO_2$에 좁은 band gap을 갖는 반도체를 이온주입하여 가시광 응답성을 갖는 양자점 감응(Quantum dot sensitized)형 광촉매를 제작하였다. 이온주입 후 시료의 chemical state와 crystallinity를 확인하기 위하여 X-ray photoelectron spectroscopy와 X-ray diffraction measurement를 이용하여 분석을 수행하였으며, 이러한 공정을 통해 제작된 양자점 감응형 광촉매의 가시광 응답성을 확인하기 위하여 UV/Vis 스펙트럼을 측정하였다. 또한 광촉매의 효율을 확인하기 위해 물 분해 장치(water splitting device) 를 제작하여 수소와 산소를 생성하였다.

  • PDF