• Title/Summary/Keyword: 조화신호

Search Result 58, Processing Time 0.023 seconds

Harmonic mode locking of 'Figure-of-Eight' fiber soliton laser using regenerative phase modulation (재생형 위상 변조에 의한 '8'자 구조 광섬유 솔리톤 레이저의 고차 조화 모드록킹)

  • 윤승철;박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.146-151
    • /
    • 1999
  • We demonstrated a harmonic mode locking scheme that used regeneratie phase modulation to get a high and stable repetition rate in a figure-of-eight fiber soliton laser. From the detected beat spectra of the laser output, a sinusoidal clock freguency tone of 400 MHz, the 96th harmonics of the fundamental mode locking frequency, was extracted with a high Q filter and was used to drive the phase modulator, resulting in stable output of soliton pulse train synchronized with the modulation signal. Generated soliton pulses had FWHM pulsewidth of 930 fs and 3.1 nm linewidth, yielding pulsewidth-bandwidth product of 0.359 that was close to the transform limit. As the modulation frequency always followed the beat frequency of laser modes, stable harmonic mode locking was achieved without the adjustment of the cavity length, which has been commonly required in actively mode-locked lasers.

  • PDF

Feature Extraction Algorithm for Distant Unmmaned Aerial Vehicle Detection (원거리 무인기 신호 식별을 위한 특징추출 알고리즘)

  • Kim, Juho;Lee, Kibae;Bae, Jinho;Lee, Chong Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.114-123
    • /
    • 2016
  • The effective feature extraction method for unmanned aerial vehicle (UAV) detection is proposed and verified in this paper. The UAV engine sound is harmonic complex tone whose frequency ratio is integer and its variation is continuous in time. Using these characteristic, we propose the feature vector composed of a mean and standard deviation of difference value between fundamental frequency with 1st overtone as well as mean variation of their frequency. It was revealed by simulation that the suggested feature vector has excellent discrimination in target signal identification from various interfering signals including frequency variation with time. By comparing Fisher scores, three features based on frequency show outstanding discrimination of measured UAV signals with low signal to noise ratio (SNR). Detection performance with simulated interference signal is compared by MFCC by using ELM classifier and the suggested feature vector shows 37.6% of performance improvement As the SNR increases with time, the proposed feature can detect the target signal ahead of MFCC that needs 4.5 dB higher signal power to detect the target.

Fault Diagnosis of High-Speed Rotating Machinery With Control Moment Gyro for Medium and Large Satellite Using Envelope Spectrum Analysis (포락선 스펙트럼 분석을 이용한 중대형 위성용 제어모멘트자이로의 고속회전체 고장진단)

  • Kang, Jeong-Min;Song, Tae-Seong;Lee, Jong-Kuk;Song, Deok-Ki;Kwon, Jun-Beom;Lee, Il;Seo, Joong-Bo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.6
    • /
    • pp.413-422
    • /
    • 2022
  • In this paper, the fault analysis of the momentum wheel, which is a high-speed rotary machinery of 'Control Moment Gyro' for medium and large satellite, was described. For fault diagnosis, envelope spectrum analysis was performed using Hilbert transformation method and signal demodulation method to find the impact signals periodically generated from amplitude modulated signals. Through this, the fault of the momentum wheel was diagnosed by analyzing whether there was a harmonic component of the rotational frequency and a bearing fault frequency in a specific frequency band with a high peak.

Design and Implementation of LPF to reduce EMI from 2.5Gbps SDH system (2.5Gbps SDH 시스템 전자파 감소용 저역통과필터 설계 및 제작)

  • 이성원;김영범
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.45-52
    • /
    • 2002
  • EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU(System Timing Genetation Unit), which is a 2.5Gbps SDH System and a major EMI source, was employed to simulate electromagnetic interface. In On-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed to minimize the effect of EMI between electronic components. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TIE and MTIE, two important quality measure in synchronous reference clcok, was assessed, ITU-T G8l3 requirements are satisfied.

  • PDF

A Basic Study on the Improvement of Leakage Error of the Acoustic Intensity (음향 인텐시티의 누설오차 개선에 관한 기초적 연구)

  • 정의봉;정호경;안세진;윤상돈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.345-350
    • /
    • 2003
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidably have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed data of a harmonic signal with a single frequency is formulated when there is leakage error. The method to eliminate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

Identification of Stiffness and Damping Matrix of Building Structures using Modal Characteristics (모드 특성을 이용한 건축 구조물의 강성 및 감쇠 행렬식별)

  • 강경수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.45-53
    • /
    • 2004
  • In this paper, the stiffness and damping matrix are experimentally constructed using the structural modal information on frequencies, damping ratio and modal vectors, which are obtained by shaking table tests. Free vibration, harmonic and white noise vibration tests are performed. The acceleration of the shaking table was used as the input signal, and the corresponding accelerations of each floor were measured as output signals. The characteristics and limitations of modal information from each test are compared. The results of this study would be a basic resource of the analytical and experimental studies on the system identification of structures.

Active Control of Harmonic Signal Based on On-line Fundamental Frequency Tracking Method (실시간 기본주파수 추종방법에 근간한 조화 신호의 능동제어)

  • 김선민;박영진
    • Journal of KSNVE
    • /
    • v.10 no.6
    • /
    • pp.1059-1066
    • /
    • 2000
  • In this paper. a new indirect feedback active noise control (ANC) scheme barred on the fundamental frequency estimation is proposed for systems with a harmonic noise. When reference signals necessary for feedforward ANC configuration are difficult to obtain, the conventional ANC algorithms for multi-tonal noise do not measure the reference signals but generate them with the estimated frequencies.$^{(4)}$ However, the beating phenomena, in which certain frequency components of the noise vanish intermittently, may make the adaptive frequency estimation difficult. The confusion in the estimated frequencies due to the beating phenomena makes the generated reference signals worthless. The proposed algorithm consists of two parts. The first part is a reference generator using the fundamental frequency estimation and the second one is the conventional feedforward control. We propose the fundamental frequency estimation algorithm using decision rules. which is insensitive to the beating phenomena. In addition, the proposed fundamental frequency estimation algorithm has good tracking capability and lower variance of frequency estimation error than that of the conventional cascade ANF method.$^{(4)}$ We are also able to control all interested modes of the noise, even which cannot be estimated by the conventional frequency estimation method because of the poor S/N ratio. We verify the performance of the proposed ANC method through simulations for the measured cabin noise of a passenger ship and the measured time-varying engine booming noise of a passenger vehicle.

  • PDF

SEM에 의한 전자파 펄스 반응의 해석

  • 이택경
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.2
    • /
    • pp.82-90
    • /
    • 1993
  • 전자파에 의한 산란현상의 해석은 지금까지 주로 시간조화함수의 형태를 지닌 전원에 의한 정 상상태의 산란에 관하여 이루어졌다. 그러나 레이다나 피파괴 검사, 전송선로 점검 등의 응용에서는 주로 펄스형태의 전자파를 사용하며, 따라서 시간에 따라 변화하는 함수형태의 전원에 의한 전자파의 산란해 석이 중요한 문제로 등장하였다. 또한 통신선로에서 외부의 잡음에 대한 혼신 등을 해석하거나, 낙뢰가 송 전선로에 미치는 영향을 해석하는 데에도 펄스신호의 산란해석이 필수적이다. 일반적인 함수의 형태를 지닌 전원에 의한 산란현상을 해석하기 위해서는 전원함수를 Fourier 변환하 여 주파수 영역의 스펙트럼을 구하고, 주파수영역에서의 산란해를 이용하여 Fourier 역변환을 하여 시간 영역의 해를 구할 수 있다. 주파수 영역에서의 산란판의 해를 Fourier 역변환 하기 위해서는 적분을 행하여야 하며, 일반적으로 적분과정에서 매우 복잡한 계산이 필요하고, 산란체의 구조가 복잡하여 해석 적인 해를 구할수 없는 경우에는 해석적으로 시간영역의 해를 구하는 것이 불가능하다. 시변 함수에 의 한 산란파를 구하기 위한 수치해석적 방법으로는 모멘트방법이나 유한요소법(Finite Element Method), 경계요소법(Boundary Element Method), 유한차분법(Finite Difference Method)등이 있으며, 해석적 해 를구할 수 없는 경우에 적용할 수 있는 반면에 많은 계산량이 요구된다.

  • PDF

Development of Comfort Sensing System for Human Environment (실내 환경의 쾌적도 측정시스템 개발)

  • Kang, Jeong-Ho;Lee, Jae-Yong;Kim, Woo-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.317-321
    • /
    • 2006
  • 본 연구는 웰빙 환경 조성에 적합한 습도센서, 온도센서와 기류센서를 이용한 쾌적도 측정시스템에 관한 것이다. 이 측정시스템이 나타내는 쾌적도는 기류와 온도에 민감하게 나타났다. 시스템을 위한 온도와 습도 일체형 센서와 기류센서를 설계 및 제작하고, 마이크로 컨트롤러에서 센서 신호를 측정하여 ISO7730에서 나타내는 예상온열 감지수(PMV)와 쾌적감 지수(CSV)를 계산하고, 각각의 계산 값을 LCD에 표시하도록 하였다. 인위의 환경에서 실험한 결과, 본 시스템이 공기조화시스템, 자동차 기류조정시스템, 가정과 사무실 병원 등의 많은 분야에 적용이 될 수 있음을 알 수 있었다.

  • PDF

Investigation on Excessive Vibration Signals of Two-Pole Generator Rotors in Balancing (발전기 양극 회전자 밸런싱에서의 이상 진동신호 분석)

  • 박종포;최성필;주영호
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.835-840
    • /
    • 1999
  • Cause of excessive vibration signals with twice the rotational speed of a 2-pole generator rotor in balancing for fossil power plants was investigated. The 2-pole generator rotor is treated as a typically asymmetric rotor in vibration analysis, and produces asynchronous vibration with twice the rotational speed for its own inertia and stiffness asymmetry. This paper introduces practical balancing procedure and experimental vibration data of the asymmetric 2-pole rotor in balancing, and presents the results of investigation into sources of the excessive vibration signals.

  • PDF