Identification of Stiffness and Damping Matrix of Building Structures using Modal Characteristics  

강경수 (동명정보대학교 건축공학과)
Publication Information
Journal of the Earthquake Engineering Society of Korea / v.8, no.2, 2004 , pp. 45-53 More about this Journal
Abstract
In this paper, the stiffness and damping matrix are experimentally constructed using the structural modal information on frequencies, damping ratio and modal vectors, which are obtained by shaking table tests. Free vibration, harmonic and white noise vibration tests are performed. The acceleration of the shaking table was used as the input signal, and the corresponding accelerations of each floor were measured as output signals. The characteristics and limitations of modal information from each test are compared. The results of this study would be a basic resource of the analytical and experimental studies on the system identification of structures.
Keywords
system identification; stiffness and damping matrix; modal information; shaking table test;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 F.T.K. Au, R.J. Jiang, and Y.K. Cheung., "Parameter identification of vehicles moving on continuous bridges," Journal of Sound and Vibration, Vol. 269, 2004, pp. 91-111.   DOI   ScienceOn
2 Juang, J.N., Applied System Identification, Prentice Hall, Englewood Cliffs, NJ., 1994.
3 Alvin, K.F., and Park, K.C., "Second-Order Structural Identification Procedure via State-Space-Based System Identification," AIAA Journal, Vol.32, 1994, pp.397-406.   DOI   ScienceOn
4 Berman, A. and Nagy, E.J., "Improvement of Large Analytical Model Using Test Data," AIAA Journal, Vol. 21, 1983, pp. 1168-1173.   DOI   ScienceOn
5 Ljung, L., System Identification: Theory for the User, Prentice Hall, Englewood Cliffs, NJ, 1987. 2.
6 민경원, 이상현, 김진구, 이영철, 이승준, 최현훈, "점탄성 감쇠기 적용을 위한 실물크기 5층 건물의 가진 및 시스템 식별", 한국지진공학회 논문집, 제7권, 제3호, 2003, pp. 1-7.   과학기술학회마을   DOI   ScienceOn
7 Chopra A.K, Dynamics of Structures : Theory and Applications to Earthquake Engineering, Prentice Hall, Englewood Cliffs, New Jersey, 2000.
8 황재승, 주석준, "구조물의 모드질량추정", 02추계학술대회논문집, 한국구조물진단학회, pp. 115-122.
9 Friswell, M.I., and Mottershead, J. E., Finite Element Model Updating in Structural Dynamics, Kluwer Academic Publishers, Boston, London, 1995.
10 Farhat, C. and Hemez, F.M., "Updating Finite Element Dynamic Models Using an Element-by-Element Sensitivity Methodology," AIAA Journal, Vol. 31, 1993, pp. 1702-1711.   DOI   ScienceOn
11 Li C. and Reinhorn J.C., "Experimental and Analytical Investigation of Seismic Retrofit of Structures with Supplemental Damping: Part II-Friction Devices," Technical Report NCEER-95-0009, National Centre for Earthquake Engineering Research, Buffalo, NY., 1995.
12 주석준, 박지훈, 민경원, 홍성목, "건축구조물의 지진응답 제어를 위한 시스템 식별의 실험적 연구", 한국지진공학회 논문집, 제3권, 제4호, 1999, pp. 47-59.   과학기술학회마을
13 Herman V. A. and Bart P., "Sensors and Systems for Structural Health Monitoring," Journal of Structural Control, Vol. 10, 2003, pp. 117-125.   DOI   ScienceOn
14 Dyke, S.J., Spencer Jr., B.F., Quast, P., Sain, M.K., Kaspari Jr., D.C., and Soong, T.T., "Experimental Verification of Acceleration Feedback Control Strategies for an Active Tendon System," Technical Report NCEER-94-0024, State University of New York at Buffalo, Buffalo, NY., 1994.
15 강경수, 이상현, 주석준, 민경원, "유한요소모델에 기초한 3층 건물모델의 시스템 식별", 03추계학술대회논문집, 한국소음진동공학회, pp. 72-77.   과학기술학회마을