A study on the Electrical Properties of Pressboard with Pulps and treatment Water (Pressboard의 펄프 및 수처리 조건에 따른 전기적 특성에 관한 연구)

  • Ahn, M.S.;Kim, I.S.;Cho, H.G.;Kang, D.P.;Son, S.D.;Son, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1370-1372
    • /
    • 1994
  • Power transformer has been expected to work with safety and reliability during the long period over 30 years. Pressboard has been effectively used as the insulating materials of transformer and they seem to be used as in insulating materials of transformer. This paper describes the results of a basic study on the electric strength, resistivity, permittivity and dielectric loss properties of pressboard to be made with some kinds of pulp and different waters.

  • PDF

A Study on The Electrical and Mechanical Characteristics due to accelerated degradation of Cycloaliphatic Epoxy Composites (CYCLOALIPHATIC 애폭시 복합재료의 가속열화에 미치는 전기적 및 기계적 특성에 관한 연구)

  • Kim, Hee-Gon;Cho, Han-Goo;Park, Yong-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1323-1326
    • /
    • 1994
  • the application of epoxy composite materials for outdoor insulating systems has some significant advantages compared with conventional inorganic materials, that is low weight in combination with high mechanical strength, small dimensions and design versatility. The experimental results for the basis composition and interlace characteristics of the matrix resin/inorganic fillers($SiO_2$) which are the composite materials have been studied. The electrical characteristics(electrical breakdown, dielectric, insulating resistivity, tracking) and mechanical characteristics( tensile strength, elongation, flexible strength) in the epoxy composite materials have been studied. The life of the epoxy composite material was evaluated by accelerated Weather-Ometer test and the degradation process due to outdoor exposure condition is discussed with respect to the mechanical and electrical properties.

  • PDF

Research and development of advanced COS for anti-contamination (염진해 특성이 향상된 COS의 개발에 관한 연구)

  • Kim, L.S.;Han, D.H.;Ahn, M.S.;Cho, H.G.;Kang, D.P.;Hwang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1599-1602
    • /
    • 1994
  • Recently, failure of COS(cut out switch) due to contamination has been increased. This paper is on the development of the contamination COS. 1 We designed a porcelain insulator of alternate shed for anti-contamination COS. 2 The COS was coated with HVIC(silicone) to improve resistivity to contamination. 3 The FOV characteristics of COS were examined to obtain dry FOV, wet FOV and contamination FOV.

  • PDF

Analysis of Electric Field Distribution of High Voltage Polymeric Bushing with Structure (초고압 폴리머 부싱의 구조에 따른 전계분포 해석)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.489-490
    • /
    • 2008
  • This paper describes the analysis of electric field distribution of high voltage polymeric bushing with structure. The high voltage bushing consists of FRP tube and housing made of LSR. The field control can be achieved by means of the design of such internal field shaper and top corona ring as grading electrodes. In accordance, the optimized design uses both internal and external elements for electric stress grading at critical parts of the bushing. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymeric bushing.

  • PDF

Series-Gap Characteristics of Polymeric Arrester for Transmission Line (송전선로용 폴리머 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, Young-Sun;Kim, Jong-Che
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

A Study on Bonded Joints of Composite Hollow Bushing (Composite Hollow Bushing의 접합기술에 관한 연구)

  • Cho, Han-Goo;Kang, Hyung-Kyung;Yoo, Dea-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.493-494
    • /
    • 2008
  • During the last years hollow core insulators started their success story in the field of high voltage engineering for electrical apparatus, substituting porcelain insulators. The termination, also named top and bottom fittings are used for the connection to the rest of the electrical apparatus. The top and bottom flange are attached to the composite to transmit mechanical load and also ensure the gas tightness. They are bonded by epoxy glue with a glass transition temperature of about $130^{\circ}C$-$150^{\circ}C$ the glass reinforced epoxy tube of filament winding. This paper describes the results of a study on the bonded joints of fiber reinforced epoxy tube and cast aluminum. This suggests that surface roughness and glue types play an important role in evaluating of gas sealing capability on the flange and fiber reinforced epoxy tube in the composite hollow bushing.

  • PDF

The Diagnosis of Polymeric Insulation Materials for Outdoor in the Salt Fog (Salt fog 내에서 옥외용 고분자 절연물의 절연진단)

  • Moon, J.S.;Kim, J.H.;Lee, J.H.;Song, W.C.;Cho, H.G.;Yoo, Y.S.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1569-1571
    • /
    • 2000
  • The ageing process was checked by leakage current monitoring in Salt Fog Method. In order to monitor leakage current, DAS with 12-bit, 8-channel A/D converter was prepared. The monitored components of leakage current were averages of the rms and peak, max peak, cumulative charge, and the cumulative number of peak pulses. The acquired data were stored to the disc periodically. And, surface conductivity was measured to investigate loss of hydrophobicity. The results suggest that surface conductivity and leakage current are well corresponding to initial loss of hydrophobicity.

  • PDF

Evaluation and Performance Test of Ball and Socet type Suspension Insulator for 300 kN Ultra High Voltage (300kN 초고압용 초고압용 볼소켓형 현수애자의 성능평가)

  • Kim, S.S.;Kim, K.U.;Her, J.C.;Cho, H.G.;Park, T.G.;Seo, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2026-2028
    • /
    • 2000
  • As the results of evaluation of its performance for 300 kN Ball and Socket type suspension insulators. There was electrically internal puncture of the solid insulating body of the insulating due to the steep front impulse voltage, which usually occurs puncture before external flash-over of insulators, moreover we have obtained satisfactory results in power arc test of 7.2kA cycle fatigue test with high qualify control index of 4.6, especially we have obtained more satisfactory results than that before improvement of its materials.

  • PDF

A Study on the Microstructral Uniformity and Surge Energy Capability of ZnO Varistor (ZnO 바리스터 미세조직 균일화와 새지 에너지 내량 향상에 관한 연구)

  • 한세원;조한구;서형권;정세영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.637-639
    • /
    • 1999
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, ZnO varistors are chosen by several electrical parameters according to their applications, namely 1mA DC voltage, 1eakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. But these Parameters have scattering properties due to the nonuniformity of electrical characteristics. In this study, the effect of the microstructrual nonuniformity on the surge absorption capability of ZnO varistors.

  • PDF

Basis Performance Evaluation and Design of Direct Current Arresters of Railway Rolling Stock (적류 전차 탑재용 피뢰기 설계 및 기본성능평가)

  • 김석수;허종철;이운용;한세원;조한구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.644-647
    • /
    • 1999
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for DC power system of railroad vehicles. The rated voltage is 1500v direct current. The main research works are focused on structure design by finite element method, rat ing vol tape, temporary over vol tape and studies of character int ice of polymeric surge arrester .