• Title/Summary/Keyword: 조한구

Search Result 232, Processing Time 0.029 seconds

The Performance Test and Mechanical Strength Analysis for 154kV Hollow Composite Insulator (154kV급 Hollow Composite Insulator의 기계적 강도해석 및 특성시험)

  • Park, Ki-Ho;Cho, Han-Gu;Han, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.495-498
    • /
    • 2002
  • This paper describes the results the problem of stress calculation and optimization into a FRP(Fiber-glass Reinforced Plastic) tube crimped into a metal end-fitting. This type of assembly is used mainly is used mainly for suspension and line post insulators. Fitting strength of FRP and flange of this study is required greatly from composite insulator to important special quality. Therefore, wish to seek analysis and mechanical strength performance that follow to FRP tube and flange of top and bottom mechanical fitting.

  • PDF

Application Technologies of Polymer Suspended Insulators for the Electric Track Line (전차 선로용 폴리머 현수애자의 적용 기술)

  • Han, Se-Won;Cho, Han-Goo;Song, Hong-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.59-61
    • /
    • 2001
  • Polymeric suspended insulators for the electric track line have been developed. The main elements to design polymeric insulators are the insulation ability related with materials of FRP core and housing, and the optimal structure related with fitting parts and interface characteristics. To confirm the design fitness of insulator samples the electric field distribution by FEM and mechanical stress distribution by NASTRAN program was analysed with housing shed shapes and fitting structure. The leakage distance and breakage voltage properties which are core parameters to determine electric insulation ability are selected according to the requirement values of user specification, then the power frequency wet withstand voltage was specified above 22kV and the leakage distance was required above 290mm. The contamination condition of the electric track line was the heavy class according to IEC 815 in order to retain the enough safety margin against overvoltages.

  • PDF

Analysis for Stress According to Pin Type of High Voltage Suspension Type Insulator (초고압 현수애자의 Pin 형상에 따른 응력해석)

  • Cho, H.G.;Park, K.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.140-142
    • /
    • 2001
  • In this study mechanical for stress according to Pin type of high voltage suspension type insulator. R-shaped metal pin. and a tapered metal pin having a tensile pin having a tensile strength of more than the breaking strength of insulating body are provided in porcelain insulating bodies, and a suspension insulator according to the present invention, a test for determining the tensile strength of the insulating body was made and the results. These insulators are designed and produced by using the computer analysis of mechanical and electrical stresses together with the technical know-how accumulated from long year of study into every respect of insulators.

  • PDF

Design and Manufacture Technology of Polymer Bushing for Pole Mount Transformer (배전급 주상 변압기용 폴리머 부싱 설계 및 제조기술)

  • Cho, Han-Goo;Lee, Un-Yang;Cheon, Jong-Uk;Park, Young-Doo;Kang, Young-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.145-149
    • /
    • 2005
  • Recently, polymer insulator and bushing that are used for high voltage application have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. The pole mount transformer installed in distribution system is acting direct role in supply of electric power and the electric power device should drive safely for long tenn. In this paper, the polymer bushing of pole transformer is designed adaptively to current assembly method, designed bushing is manufactured on basis of that result. The electric field of designed transformer is investigated by FEM program.

  • PDF

The analysis of leakage current characteristics of polymer insulators for estimation under Pollution conditions (고분자 절연물의 내오손 진단을 위한 누설전류 특성 해석)

  • Kim, I.S.;Han, S.W.;Cho, H.G.;Soh, J.J.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1452-1454
    • /
    • 1997
  • Properties of flashover in polymer insulators are very important under pollution environments. It is necessary to analyse flashover characteristics whether insulators are still safe or not. A lot of precious information can be got out of polluted polymer insulators through leakage current measurement. The behavior of partial arc discharge leads to flashover directly. It is possible to measure partial arc discharge as leakage current pulses analysis. The shape of histogram reflects degree of pollution, wetting and voltage stress level. It can be expressed by Weibull distribution function.

  • PDF

Zinc Oxide Varistors with Praseodymium Oxide (Praseodymium계 ZnO 바리스터의 제조 및 미세구조 연구)

  • Soh, J.J.;Han, S.W.;Kim, H.S.;Cho, H.G.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1342-1344
    • /
    • 1997
  • Zinc oxide varistors which contain rare earth metal oxides have been developed. These Varistors are widely used for low voltage surge-protection devices and high voltage arresters for electric power stations. The characteristics of varistors with praseodymium oxide as a principal additive are discussed. A two-phase microstructure with an intergranular phase between the ZnO grains.

  • PDF

The Development of Evaluation Technology for Transmission Lines NCI (송전용 Non-Ceramic Insulator의 성능평가 기술개발)

  • Kim, I.S.;Cho, H.G.;Park, W.K.;Hong, G.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1193-1195
    • /
    • 1997
  • The chief advantage of these NCI, from a handling viewpoint. was an up to 90% weight reduction over their porcelain counter. Diagnosis and the life expectancy of NCI for transmission lines depend on a number of factors, many of which are associated with natural tracking breakdown, while others are related to manufacturing conditions. Recently The importance of optimizing a NCI for good performance under a wide variety of test condition and diagnosis is emphasized ; as well as the increased importance of natural breakdown testing. Today, at transmission lines, NCI have become very popular at 154 through 345 kV.

  • PDF

The Evaluation of Tracking and Erosion Resistance of Silicone Rubber for Outdoor Use by the Inclined-Plane Method (경사평면법에 의한 옥외용 실리콘고우의 내트래킹성 및 내침식성 평가)

  • Kim, J.H.;Song, W.C.;Park, Y.G.;Kim, H.G.;Kim, I.S.;Han, S.W.;Cho, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1500-1502
    • /
    • 1997
  • We investigated the tracking and erosion resistance of the silicone rubber by Inclined-Plane Method. And, with the variation of the accelerated conditions such as the applied voltage and composition of contaminant, the change of the tracking characteristics according to such conditions was evaluated. The leakage current significantly increases with the increasing voltage, but the weight loss remains almost the same. The voltage above 5.0 kV isn't recommended because tracking breakdown occurs as fast as it does without erosion, and the typical discharge waveform was the form of rectifying wave.

  • PDF

A Study on the Lightning Surge Protection Methods on Transmission System and Substation (송전계통 및 변전소 뇌서지 보호방안 연구)

  • Kim Jae-Kwan;Jung Chae-Kyun;Lee Jong-Beom;Cho Han-Goo;Seo Je-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.279-285
    • /
    • 2005
  • The lightning causes the damage of power system equipments as well as large power failure. Therefore, the insulation design should be established not only to decrease the damage of the facilities itself but also to increase the reliability of electric power system. This paper describes the useful way applying underbuilt ground wire and guy wire in transmission tower that safely protect the substation equipments. One or more shield wires under the phase conductor will not intercept lightning stroke, but they may improve reduce lightning voltages almost as effectively as if they were above the phase conductors. And the guy wires will mitigate the tower surge response. These would not only reduce backflashover possibility but also minimize crest and duration of surges entering the substation. EMTP is used to analyze the efficiency of the proposed methods.

Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings (가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가)

  • Cho, H.G.;Kim, I.S.;Ahn, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF