• Title/Summary/Keyword: 조직지지

Search Result 554, Processing Time 0.023 seconds

Characteristics of porous Chitosan-Alginate-Gelatin Scaffold Cross-linked by Heat-treatment (열처리에 의해 가교된 다공성 키토산-알지네이트-젤라틴 지지체의 특성)

  • Sin, Byeong-Cheol;Choe, Min-Su;Han, Hui-Dong;Seong, Ha-Su
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.3
    • /
    • pp.224-231
    • /
    • 2006
  • agents used for enhancing mechanical properties of porous natural scaffolds, reduces biocompatability of the scaffolds, due to their inherent cytotoxicity. In this study, scaffolds which was composed of chitosan, alginate and gelatin were cross-linked by using heat treatment instead of cross-linking agent and mechanical properties of the cross-linked scaffold were investigated. Fourier transform infrared spectroscopy (FT-IR) analysis confirmed that cross-linking of heat-treated scaffold was formed via amide or ester linkage between the polymer chains. The heat-treated scaffold had interconnected pores with mean diameter of 100~200 m and showed more than two fold increase of water uptake in comparison with chemically cross-linked scaffold. Tensile strength of the heat-treated scaffold increased up to 130% compared to non cross-linked scaffold and average maximum elongation was 11.3%. The porous cross-linked scaffold with the improved mechanical property may be suitable as a biocompatable scaffold for tissue engineering.

Relationship among Emotional Labor, Burnout, Social Support and Turnover Intention of Nurse Practitioners in terms of Interdisciplinary Perspectives (융복합 관점에서 임상간호사들의 감정노동, 직무소진, 사회적 지지, 이직의도의 관계)

  • Kim, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.14 no.8
    • /
    • pp.331-342
    • /
    • 2016
  • The great attention has been shown the importance of human resource management in medical institutions. At this point, studies have stressed employees' psychological factors for maximizing their job performance and minimizing their turnover intention and burnout. This study, therefore, empirically examines the mediating effect of social support on the relationship between emotional labor, burnout, and turnover intention of medical institutions, focusing on nurse practitioners to contribute to hospital management for developing valuable strategies in the human resource sector of medical employees. The empirical results demonstrate: 1) the relationship between emotional labor and burnout of nurse practitioners is mediated by social support; and 2) the relationship between emotional labor and turnover intention of them is mediated by social support. This research results show that more understanding of nurse practitioners' psychological factors in response to decrease their burnout and turnover intention for developing human resource management of nurse organizations. Furthermore, the study could suggest efficient management ways of hospital through interdisciplinary human resource management in terms of business administration and psychology.

In Vivo Experiment of Tissue-Engineered Artificial Vessel (조직공학적 인조혈관의 생체 내 이식 실험)

  • 임상현;조승우;홍유선;김병수;유경종;장병철;최차용
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2004
  • The number of patients with coronary artery disease and peripheral vascular disease are increasing, and the need of small diameter vessel is also increasing. We developed small diameter artificial vessel and experimented in vivo. We got allogenic valve from mongrel dogs, and removed all cells from the allogenic valve. Then, we seeded autologous bone marrow cells onto the decellularized scaffold. After implantation of artificial vessel into the canine carotid artery, we performed angiography regularly. In case of vessel occlusion or at 8 weeks after operation, we euthanized dogs, and retrieved the implanted artificial vessels. Control vessels were all occluded except one (which developed aneurysmal dilatation). But autologous cell seeded vascular graft were patent by 4 weeks in one, by 6 in one and by 8 weeks in two. Histologic examination of patent vessel revealed similar structure to native artery. Tissue-engineered vascular graft manufactured with decellularized allogenic matrix and autologous bone marrow cells showed that tissue engineered graft had similar structure to native artery.

Fabrication and Characteristic Evaluation of Three-Dimensional Blended PCL (60 wt %)/β-TCP (40 wt %) Scaffold (3 차원 Blended PCL (60 wt %)/β-TCP (40 wt %) 인공지지체의 제작 및 특성 평가)

  • Sa, Min-Woo;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.4
    • /
    • pp.371-377
    • /
    • 2014
  • In tissue engineering, a scaffold is a three-dimensional(3D) structure that serves as a template for regeneration the functions of damaged tissues or organs. Among materials for scaffolds, polycaprolactone(PCL) and ${\beta}$-tricalcium phosphate(${\beta}$-TCP) are biodegradable and biocompatible. In this study, we fabricated 3D PCL, blended PCL (60 wt %)/${\beta}$-TCP (40 wt %), and pure ${\beta}$-TCP scaffolds by a multi-head scaffold fabrication system. Scaffolds with a pore size of $600{\pm}20{\mu}m$ was observed by scanning electron microscopy. The effects of 3D PCL, blended PCL (60 wt %)/${\beta}$-TCP (40 wt %) and pure ${\beta}$-TCP scaffolds were analyzed by evaluating their mechanical characteristics. In addition, in an in-vitro study using osteoblast-like saos-2 cells, we confirmed the effects of 3D scaffolds on cellular behaviors such as cell adhesion and proliferation. In summary, the 3D blended PCL (60 wt %)/${\beta}$-TCP (40 wt %) scaffold was found to be suitable for human cancellous bone in terms of its the compressive strength, biocompatibility, and osteoconductivity. Thus, blending PCL and ${\beta}$-TCP could be a promising approach for fabricating 3D scaffolds for effective bone regeneration.

조직공학에 사용되는 세포지지체의 기계적 특성

  • Kim, Min-Su;Kim, Hui-Gyeong;Ji, Min-Hui;Jo, Yeong-Sam
    • Journal of the KSME
    • /
    • v.52 no.12
    • /
    • pp.49-53
    • /
    • 2012
  • 이 글에서는 조직공학에 사용되는 재료들의 기계적 특성에 대해 간략하게 정리하였다. 당연하게도, 각각의 재료들은 그 기계적/화학적 특성에 맞는 제작방법이 필요하며, 이러한 기계적/화학적 특성들은 타겟 장기/조직이 필요로 하는 그것과 유사해야 한다.

  • PDF

Biodisc Tissue-Engineered Using PLGA/DBP Hybrid Scaffold (DBP/PLGA 하이브리드 담체를 이용한 조직공학적 바이오 디스크 개발)

  • Ko, Youn-Kyung;Kim, Soon-Hee;Jeong, Jae-Soo;Ha, Hyun-Jung;Yoon, Sun-Jung;Rhee, John-M.;Kim, Moon-Suk;Lee, Hai-Bang;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.31 no.1
    • /
    • pp.14-19
    • /
    • 2007
  • Demineralized bone particle (DBP) has been used as one of the powerful inducers of bone and cartilage tissue specialization. In this study, we fabricated DBP/PLGA scaffold for tissue engineered disc regeneration. We manufactured dual-structured scaffold to compose inner cylinder and outer doughnut similar to nature disc tissue. The DBP/PLGA scaffold was characterized by porosity, wettability, and water uptake ability. We isolated and cultured nucleus pulposus (NP) and annulus fibrosus (AF) cells from rabbit intervertebral disc. We seeded NP cells into the inner core of the hybrid scaffold and AF cells into the outer portion of it. Cellular viability and proliferation were assayed by 3-(4,5-dimethylthiazole-2-yl) -2,5- diphenyltetrazolium -bromide (MTT) test. PLGA and PLGA/DBP scaffolds were implanted in subcutaneous of athymic nude mouse to observe the formation of disc-like tissue in vivo. And then we observed change of morphology and hematoxylin and eosin (H&E). Formation of disc-like tissue was better DBP/PLGA hybrid scaffold than control. Specially, we confirmed that scaffold impregnated 20 and 40% DBP affected to proliferation of disc cell and formation of disc-like tissue.

The Effect of Pore Sizes on Poly(L-lactide-co-glycolide) Scaffolds for Annulus Fibrosus Tissue Regeneration (조직공학적 섬유륜재생을 위한 PLGA 지지체 제조시 다공크기의 영향에 관한 연구)

  • So, Jeong-Won;Jang, Ji-Wook;Kim, Soon-Hee;Choi, Jin-Hee;Rhee, John-M.;Min, Byung-Hyun;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.516-522
    • /
    • 2008
  • Biodegradable polymers have been used extensively as scaffolding materials to regenerate new tissues and the ingrowth of tissue have been reported to be dependent directly of the porosity, pore diameter, pore shape, and porous structure of the scaffold. In this study, porous poly (L-lactide-co-glycolide) (PLGA) scaffolds with five different pore sizes were fabricated to investigate the effect of pore sizes for AF tissue regeneration. Cellular viability and proliferation were assayed by MTT test. Hydroxyproline/DNA content of AF cells on each scaffold was measured. sGAG analyses were performed at each time point of 2 and 6 weeks. Scaffold seeded AF cells were implanted into the back of athymic nude mouse to observe the difference of formation of disc-like tissue depending on pore size in vivo. We confirmed that scaffold with $180{\sim}250{\mu}m$ pores displayed high cell viability in vitro and produced higher ECM than scaffold with other pore sizes in vivo.

Factors Affecting Organizational Commitment of Foreign Workers (외국인 근로자의 조직몰입에 영향을 미치는 요인 연구)

  • Lee, Yu-na;Ha, Kyu-soo
    • Journal of Venture Innovation
    • /
    • v.6 no.1
    • /
    • pp.161-179
    • /
    • 2023
  • More than 2 million foreigners were staying in Korea. In this study, the effect of individual and environmental characteristics of foreign workers on organizational commitment was empirically analyzed. A research model for empirical analysis was established. A research model was established independent variables by dividing them into four parts: personal desire, adaptability, organizational life, and social support and setting organizational commitment as dependent variables. Based on this research model, data collection for analysis was conducted in a survey method for foreign workers in Korea. An empirical analysis was conducted using SPSS 24 based on 200 valid sample of the respondents. The results of the empirical analysis were as follows. First, it was found that foreign workers' desire for achievement, language adaptability, relationships with supervisors and colleagues, future vision of jobs, and social support had a significant positive (+) effect on organizational commitment. On the other hand, the significant influence relationship of cultural adaptability was not tested. Second, factors that significantly affect organizational commitment was in the order of social support, relationships with supervisors and colleagues, future vision of jobs, language adaptability, and desire for achievement. Based on these research results, academic implications were presented, and practical implications were presented to increase the organizational commitment of foreign workers.

The accuracy evaluation of digital surgical stents according to supported type (디지털 수술용 가이드의 지지타입에 따른 정확도 평가)

  • Lee, Junyoun;Yoon, Minho;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. Materials and methods: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. Results: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. Conclusion: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.