• Title/Summary/Keyword: 조작장치

Search Result 461, Processing Time 0.029 seconds

How does the introduction of smart technology change school science inquiry?: Perceptions of elementary school teachers (스마트 기기 도입이 과학탐구 활동을 어떻게 변화시킬 것인가? -교육대학원 초등과학 전공 교사의 인식 사례를 중심으로-)

  • Chang, Jina;Joung, Yong Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.37 no.2
    • /
    • pp.359-370
    • /
    • 2017
  • The purpose of this study is to explore the changes caused by using smart technology in school science inquiry. For this, we investigated 12 elementary school teachers' perceptions by using an open-ended questionnaire, group discussions, classroom discussions, and participant interviews. The results of this study indicate that the introduction of technology into classroom inquiry can open up the various possibilities and can cause additional burdens as well. First, teachers explained that smart technology can expand the opportunities to observe natural phenomena such as constellations and changing phases of the moon. However, some teachers insisted that, sometimes, learning how to use new devices disrupts students' concentration on the inquiry process itself. Second, teachers introduced the way of digital measurement using smart phone sensors in inquiry activities. They said that digital measurement is useful in terms of the reduction of errors and of the simplicity to measure. However, other teachers insisted that using new devices in classroom inquiry can entail additional variables and confuse the students' focus of inquiry. Communication about inquiry process can also be improved by using digital media. However, some teachers emphasized that they always talked about both the purpose of using SNS and online etiquettes with their students before using SNS. Based on these results, we discussed the necessity of additional analysis on the various ways of using digital devices depending on teachers' perceptions, the types of digital competency required in science inquiry using smart technology, and the features of norms shaped in inquiry activities using smart technology.

Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture - (트랙터부착형 타워집재기 개발(I) - 설계 및 제작-)

  • Park, Sang-Jun;Kim, Bo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This study was conducted to develop a mobile tower-yarder with tractor for agriculture and forestry that is the efficient yarder in steep terrains, thinning operation and small scale logging operation. It was designed and manufactured that the power source of tower-yarder is equiped three hydraulic pump connected to PTO of tractor, and three hydraulic pump is used to operate the four motor for drum, the cylinder for clutch of interlocker, the cylinder for tower expanding and the out-rigger cylinder. It was to adopt the running skyline system and the inter-lock function, and to equip the double capstan drum, the storage drum and the clutch for interlock in the development of tower-yarder. It was to develop the tower-yarder which the winch torque of double-capstan drum, the traction force of double-capstan drum, the number of rotation of double-capstan drum and the line speed is $191kg{\cdot}m$, 1,910 kgf, 220.5 rpm and 138.5 m/min, respectively. And it was known that the optimum flange diameter of the main and haulback storage drum is about 360 mm and about 460 mm in order to storage the main line length of 250m and the haulback line length of 450 m. The carriage was made to adopt the running skyline system and to equip the lock function in order to the convenience of chocking and the fall down preventing of tree. It was provided to develop the wire remote controller for the inter-lock function, the convenience of control and the efficiency of yarding. In development process, this tower-yarder was attached the 3-point linkage hitch equipment and the tire wheel for the traction and moving of tower-yarder. Also, it was equipped that the out-rigger and the guy line in order to raise the safety and efficiency of yarding of tower-yarder.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향)

  • Sung, Hye-Jin;Ha, Jung-Hong;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.380-386
    • /
    • 2010
  • Objectives: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. Materials and Methods: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screwin force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. Results: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). Conclusions: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.

Clinical Aspects of Bacteremia in Medical and Surgical Intensive Care Units (내과 및 외과계 중환자실 환자 균혈증의 임상적 고찰)

  • Kim, Eun-Ok;Lim, Chae-Man;Lee, Jae-Kyoon;Mung, Sung-Jae;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Hwan;Choi, Jong-Moo;Pai, Chik-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.535-547
    • /
    • 1995
  • Background: Intensive care units(ICUs) probably represent the single largest identifiable source of infection within the hospital. Although there are several studies on ICU infections in respect to their bacteriology or mortality rate for individual types of ICU, few studies have compared ICU infections between different types of ICU. The aim of this study was to identify clinical differences in bacteremia between medical ICU(MICU) and surgical ICU(SICU) patients. Methods: 256 patients with bacteremia were retrospectively evaluated. Medical records were reviewed to obtain the clinical and bacteriologic informations. Results: 1) The mean age of the patients with bacteremia of MICU($58.6{\pm}17.2\;yr$) was greater than that of all MICU patients($54.3{\pm}17.1\;yr$)(p<0.01), but there was no significant difference in SICU patients(patients with bacteremia of SICU: $56.3{\pm}18.6\;yr$, all SICU patients: $62.0{\pm}16.8$)(p>0.05). ICU stay was longer(MICU patients: $23.4{\pm}40.8$ day, SICU patients: $30.3{\pm}26.8$ day) than the mean stay of all patients($6.8{\pm}15.5$ day)(p<0.05, respectively). Bacteremia of both ICU patients developed past the average day of ICU stay(all MICU patients: 7.9 day, all SICU patients: 6.0 day, MICU bacteremia: 19th day, SICU bacteremia: 17th day of ICU stay)(p<0.05, respectively). 2) There were no significant differences in mean age, sex, and length of stay of both ICU patients with bacteremia. 3) Use of antibiotics or steroid, use of percutaneous devices and invasive procedures before development of bacteremia were more frequent in SICU patients than in MICU patients(prior antibiotics use: MICU 45%, SICU 63%, p<0.05; steroid use: MICU 14%, SICU 36%, p<0.01; use of percutaneous devices: MICU 19%, SICU 39%, p<0.01; invasive procedures: MICU 19%, SICU 61 %, p<0.01). 4) The prevalence of community acquired infections was significantly higher in MICU patients than in SICU patients(MICU 42%, SICU 9%)(p<0.01), whereas SICU patients showed higher prevalence of ICU-acquired infection than MICU patients(MICU 48%, SICU 78%)(p<0.01). 5) There were no differences in causative organisms, primary sites of infection and time interval to bacteremia between both ICUs. 6) There were no significant differences in outcome according to pathogenic organisms or primary sites of infection. 7) The mortality rate was higher in patients with bacteremia than without bacteremia(MICU mortality rate: patients with bacteremia 72.5%, patients without bacteremia 36.0%, p<0.01; SICU mortality rate: patients with bacteremia 40.3%, patients without bacteremia 8.5%, p<0.05), and the mortality rate of MICU bacteremia was significantly higher compared with that of SICU bacteremia(MICU 72.5%, SICU 40.3%)(p<0.01). Conclusion: ICU patients with bacteremia stayed longer before the development of bacteremia, and showed higher mortality than the overall ICU population. The incidence of bacteremia was higher in MICU patients than SICU patients. MICU patients with bacteremia showed higher prevalence of liver diseases and acute respiratory failure, community-acquired bacteremia and greater mortality rate than SICU patients with bacteremia. SICU patients with bacteremia, on the other hand, showed higher prevalence of trauma, prior use of immunosuppressive agents, invasive procedures, and ICU-acquired bacteremia, and lower mortality rate than MICU patients with bacteremia.

  • PDF

Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images (방사선치료 시 환자자세 검증을 위한 분석용 도구 개발)

  • Lee Suk;Seong Jinsil;Kwon Soo I1;Chu Sung Sil;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.100-106
    • /
    • 2003
  • Purpose : To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproduclbility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT). The utilization of this system is evaluated through phantom and patient case studies. Materials and methods : We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, porial and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT Images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. Results : The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT. The results show that the localization errors are 0.8$\pm$0.2 mm (AP) and 1.0$\pm$0.3 mm (Lateral) in the cases relating to the brain and 1.1$\pm$0.5 mm (AP) and 1.0$\pm$0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software Conclusions : A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproduclbility of the patients' setup in 3DCRT and IMRT. With adjustment of the completed GUI-based algorithm, and a good quality DRR image, our software may be used for clinical applications.

Strategies of Car-Ferry Shipping Companies According to the Korea-China Free Trade Agreement (한·중 FTA 체결에 따른 수도권항만 카페리선사의 발전방안)

  • Park, Sung-Eun;Ahn, Seung-Bum
    • Journal of Korea Port Economic Association
    • /
    • v.34 no.1
    • /
    • pp.111-132
    • /
    • 2018
  • As China continues to evolve as a major economic power and the Free Trade Agreement (FTA) between the Republic of Korea and China was ratified on June 1, 2015, market volume between the two countries is expected to grow more rapidly. This study aims on improving the efficiency of car-ferry lines. We conducted two surveys- for shippers and forwarders of car-ferry companies, and container liners. The study analyzes the decision factors for delivery companies and their importance for shippers and forwarders of car-ferry companies and container liners. Based on analysis of prior studies on the competition for car-ferry companies and liners, three primary variables are selected-promptness, economics, and safety. The promptness variable consists of shipping time, loading/unloading time, and customs clearing time. The economic variable consists of marine transportation cost from a domestic harbor to China, loading/unloading cost in the harbor, and overland transport cost from the harbor to shippers inland. Finally, the safety variable consists of cargo damage rates, safety facilities, such as lashing and shoring, and punctuality of transportation time. The survey and AHP results show that the promptness, safety, and economics factors are 0.549, 0.309, and 0.142 in the shipper groups of car-ferry companies' category, respectively. It indicates that there is considerable difference in the importance of each factor. In contrast, the factors are 0.350, 0.348, and 0.302 in the forwarders category, which suggests that there is little difference in each factor's importance. As for shippers and forwarders of liners, the importance of each factor is found to be in the following order: economics, safety, and promptness.

SLUMPING TENDENCY AND RHEOLOGICAL PROPERTY OF FLOWABLE COMPOSITES (Flowable 복합레진의 slumping 경향과 유변학적 성질)

  • Lee, In-Bog;Min, Sun-Hong;Kim, Sun-Young;Cho, Byung-Hoon;Back, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.130-136
    • /
    • 2009
  • The aim of this study was to develop a method for measuring the slumping resistance of flowable resin composites and to evaluate the efficacy using rheological methodology. Five commercial flowable composites (Aelitefil flow:AF, Filtek flow:FF, DenFil flow:DF, Tetric flow:TF and Revolution:RV) were used. Same volume of composites in a syringe was extruded on a glass slide using a custom-made loading device. The resin composites were allowed to slump for 10 seconds at $25^{\circ}C$ and light cured. The aspect ratio (height/diameter) of cone or dome shaped specimen was measured for estimating the slumping tendency of composites. The complex viscosity of each composite was measured by a dynamic oscillatory shear test as a function of angular frequency using a rheometer. To compare the slumping tendency of composites, one way-ANOVA and Turkey's post hoc test was performed for the aspect ratio at 95% confidence level. Regression analysis was performed to investigate the relationship between the complex viscosity and the aspect ratio. The results were as follows. 1. Slumping tendency based on the aspect ratio varied among the five materials (AF

Microbial Hazard Analysis of Manufacturing Processes for Starch Noodle (당면의 제조공정별 미생물학적 위해요소 분석)

  • Cheon, Jin-Young;Yang, Ji Hye;Kim, Min Jeong;Lee, Su-Mi;Cha, Myeonghwa;Park, Ki-Hwan;Ryu, Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.420-426
    • /
    • 2012
  • The purpose of this study was to identify control points through microbiological hazard analysis in the manufacturing processes of starch noodles. Samples were collected from the ingredients, manufacturing processes, equipment and environment. Microbiological hazard assessments were performed using aerobic plate counts (APC), Enterobacteriaceae (EB), E. coli and five pathogens including B. cereus, E. coli O157:H7, L. monocytogenes, Salmonella spp., and S. aureus. The APC levels in raw materials were from 2.12 to 3.83 log CFU/g. The contamination levels after kneading were 4.31 log CFU/g for APCs and 2.88 log CFU/g for EB counts. APCs decreased to 1.63 log CFU/g and EB were not detected after gelatinization, but their levels slightly increased upon cooling, cutting, ripening, freezing, thawing, and separating. The reuse of cooling and coating water would be a critical source of microbial increase after cooling. After drying, APCs and EB counts decreased to 5.05 log CFU/g and 2.74 log CFU/g, respectively, and the levels were maintained to final products. These results suggest that the cooling process is a critical control point for microbiological safety, and the cooling water should be treated and controlled to prevent cross contamination by pre-requisite program.

Separation Permeation Characteristics of N2-O2 Gas in Air at Cell Membrane Model of Skin which Irradiated by High Energy Electron (고에너지 전자선을 조사한 피부의 세포막모델에서 공기 중의 O2-N2 혼합기체의 분리투과 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.261-270
    • /
    • 2019
  • The separation permeation characteristics of $N_2-O_2$ gas in air at cell membrane model of skin which irradiated by high energy electron(linac 6 MeV) were investigated. The cell membrane model of skin used in this experiment was a sulfonated polydimethyl siloxane(PDMS) non-porous membrane. The pressure range of $N_2$ and $O_2$ gas were appeared from $1kg_f/cm^2$ to $6kg_f/cm^2$. In this experiment(temperature $36.5^{\circ}C$), the permeation change of $N_2$ and $O_2$ gas in non-porous membrane by non-irradiation were found to be $1.19{\times}10^{-4}-2.43{\times}10^{-4}$, $1.72{\times}10^{-4}-2.6{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. That of $N_2$ and $O_2$ gas in non-porous membrane by irradiation were found to be $0.19{\times}10^{-4}-0.56{\times}10^{-4}$, $0.41{\times}10^{-4}-0.76{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. The irradiated membrane was significantly decreased about 4-10 times than membrane which was not irradiated. And ideal separation factor of $N_2$ and $O_2$ gas by non-irradiation was found to be from 1.32 to 0.42 and that of $N_2$ and $O_2$ gas by irradiation was found to be from 0.237 to 0.125. The irradiated membrane was significantly decreased about 4-5 times than membrane which was not irradiated. When the operation change(cut) and pressure ratio(Pr) by non-irradiation were about 0, One was increased to the oxygen enrichment and the other was decreased to the oxygen enrichment. The irradiated membrane was significantly decreased about 4-19 times than membrane which was not irradiated. As the pressure of $N_2$ and $O_2$ gas was increased, the selectivity was decreased. As separation permeation characteristics of $N_2-O_2$ gas in cell membrane model of skin were abnormal, cell damages were appeared at cell.