• Title/Summary/Keyword: 조명설비

Search Result 5,842, Processing Time 0.028 seconds

A Trend Analysis on Professional Engineer Examination in Korea Railway Signaling (출제경향 분석을 통한 철도신호기술사 고시의 학습방법 고찰)

  • Lim, Bea-Kyun;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.41-46
    • /
    • 2008
  • The railway is an important industry which quickly and safely transports a great deal of people and goods compared to other methods of transportation. Because there is not enough manpower in this field, professional engineers are urgently demanded. Although there are many people who apply for the Korea railway signaling professional engineer examination, they do not know how and what to prepare for it. This Paper analyzes the pattern of questions in the examination for the last fifteen years and the trend of the examination. The subjects which have been taught in railway related educational institutions for the last five years are also analyzed. This paper suggests some essential subjects that should be studied in order to show an easy way to obtain the certificate to those who prepare for the examination.

Low-Cost LED Driver Circuit using Power Factor Compensation Capacitor of Discharge Lamp (방전램프의 역률 보상용 콘덴서를 이용한 저가형 LED 구동회로)

  • Ko, Jae-Ha;Hwang, Jung-Goo;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.16-25
    • /
    • 2013
  • Now it's a trend to install a series of white fluorescent light and orange high pressure sodium lamps because tunnel lighting should be opaque to the safety of drivers from soot, dust, humidity, and fog. Also fluorescent lighting is replaced to LED due to the fact that it improves amenity and object recognition and LED lighting has gradually been improved its nature. In this paper, we have implemented the circuits of the yellow series of high-pressure sodium lamps and white series of LED lights at one board to improve the transparency and recognition of objects. It is possible for inductive high-pressure sodium lamps and the capacitive LED drivers to circuit without power factor compensation. Two circuit parts share only a small number of parts, so low cost LED drivers compared to conventional ones are possible. Therefore, the implementation of the hybrid lighting with high-pressure sodium lamps and LED lights that can be driven at the same time by one driving circuit is possible. The LED capacitive power factor was 0.91 while individually implemented the sodium lamp power factor was 0.98. It shows not only the 2% improvement of hybrid forms but also the efficiency and THD.

Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices (RCD와 SPD의 접속 위치에 따른 보호협조)

  • Lee, Bok-Hee;Park, Hee-Yeoul;Shin, Gun-Jin;Bae, Gwan-Young;Ryu, Chun-Hyoung;Lee, Kang-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.

Study on the method to evaluate performance of Light Collector in Light-collecting System (집광채광 설비 입사부의 성능 평가방법에 관한 연구)

  • Yoon, Yongsang;Mun, Sunhye
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.49.1-49.1
    • /
    • 2011
  • 집광채광 설비는 건축물의 조명에너지 절감 및 자연광의 실내 유입을 위해 적용 가능한 태양에너지설비로써 다른 신 재생 에너지 설비와 다르게 연간에너지생산에 대한 정량적 데이터가 아직까지 부재하다. 집광채광 설비의 설치효과를 판단하기 위해서는 집광채광 설비 설치에 따른 연간 에너지생산량 산출이 필요하며, 이를 위해서는 각 구성부분(집광부, 전송부 및 산광부)의 광전송 효율에 대한 데이터가 구축되어야 한다. 본 연구는 집광채광 설비의 효율 분석에 관한 첫 번째 단계로써 외부광속에 대한 집광부 통과 직후의 내부광속의 비율을 예측하였다. 국내에 보급된 집광채광 설비는 대부분 프리즘형과 광덕트형이며, 우선적으로 집광부 입사면의 경사각과 방위각이 다양하여 내부광속 산출방법론이 매우 복잡한 프리즘형을 분석대상으로 삼았다. 전일사량, 외부조도 및 집광부 내부조도가 측정되었으며, 외부광속으로부터 내부광속을 산출하는 공식을 유도하기 위해 천공상태에 따라 전일사량 측정치가 직산분리 되었다. Perez model과 Liu and Jordon에 의해 제시된 계산식과 입사면 및 집광부 면적을 고려하여 수평면 외부조도 측정치로부터 외부광속이 그리고 내부조도로부터 내부광속이 산출되었다. 입사면의 투과율이 동일하다는 전제 하에 천공상태에 따른 태양광 투과 비율을 도출한 결과, 담천공(Kt ${\leq}$ 0.3)에서 0.39, 부분담천공(0.3${\geq}$ 0.78)에서 1.0으로 나타났다. 도출된 투과비율을 외부광속에 적용하여 내부광속을 계산한 결과치와 측정치는 약 ${\pm}9%$ 정도의 차이를 보였다. 연간 기상데이터에 위와 같은 방법론이 적용되면 프리즘형 집광부의 연간 내부광속이 산출될 수 있다. 또한 기존 연구에서 제시된 발광효율 산출식과 일사 파장에 따른 시감도를 고려하면 매 시간별 외부조도도 산출이 가능하다. 일사량 측정치와 외부조도 측정치 사이의 상관관계를 분석한 결과 결정계수 $R^2$이 0.99인데 반해 일사량 측정치와 외부조도 계산치 사이의 상관관계 결정계수는 0.95로 측정치 보다 약간 작은 값을 갖는다. 이렇게 산출된 외부조도는 각 입사면의 면적을 반영하여 외부광속으로 변환되고, 앞서 산출된 천공상태별 투과비율이 적용됨으로써 내부광속이 도출될 수 있다. 이와 같은 집광부에 대한 연구를 바탕으로 향후 전송부와 산광부 효율을 도출하고 궁극적으로 집광채광 설비를 통해 실내에 전달되는 연간 빛에너지를 예측할 수 있을 것이다. 또한 본 연구의 방법론은 다른 형태의 집광채광 설비에도 적용이 가능할 것으로 판단되며, 국내 집광채광 설비의 연간 에너지생산량에 대한 폭 넓은 데이터 구축이 가능할 것으로 기대된다.

  • PDF

Analysis of Urban Park Nightscape based on the Design-Construction Process and Current Status - Focused on Yeouido Park - (도시공원 야간경관의 조성 과정과 실태 분석 - 여의도공원을 중심으로 -)

  • Kim, Hyun-Geun;Kim, Ah-Yeon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.2
    • /
    • pp.14-26
    • /
    • 2018
  • Light has been an essential part of human life. The advancement of technology has changed cities' nightscape and night activities in a drastic way. Lighting has influenced the identity of a city while promoting a variety of civic nighttime cultural pursuits, yet lighting design has not been considered adequately in the field of landscape architecture. This study aims to analyze the current status of lighting in urban parks through interviews with professionals, literature and regulation reviews, analysis of design documents and a field survey focused on Yeouido Park in Seoul. The findings and improvement directions are as follows. First, it is necessary to develop a specific lighting design method in order to avoid a marginalized, passive approach such as light fixture installation. Second, the existing standards of illuminance by KS A 3011 regulating only horizontal illuminance has turned out not to evaluate the current nightscape of urban parks properly. Therefore the criteria and guideline for analysis and design for nightscape should be articulated. Third, there are no design or management strategies to consider the changing landscape of urban parks, which is necessary due to the changing characteristics of park ecosystems. Lastly, detailed guidelines for distinguished spaces in urban parks should be studied and suggested.

Implementation of the Home Network System by use of the Power Line Communication (전력선통신을 이용한 홈 네트워크 시스템 구현)

  • Kim, Sun-Hyung;Lee, Doo-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.1
    • /
    • pp.124-130
    • /
    • 2011
  • In this paper, we propose a method for the efficient power use in power outage. The cost is high and conversion into the other function is difficult since the terminal used in conventional home network system has a dedicated function. This method is based on home network system employed with photovoltaic system. Throughout the modularization of the terminal, the variable function and cost reduction can be achieved. Additionally the unit cost can be reduced by using the power line communication. The prototype of light-control terminal has been implemented. The experimental results with the terminal show the performance of light-control system and the possibility of the commercialization can be achieved.

Efficient Lighting System for Amenity Light Environment (쾌적 빛 환경을 위한 효율적 조명 시스템)

  • Choi, Jong-Hyo;Oh, Myoung-Won;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.136-141
    • /
    • 2009
  • Considerable part of energy consumption is occurred by through buildings. Especially, Lighting energy consumption is most part of one in building. There is very various ways and systems for saving lighting energy. In method, It can be divided Passive Daylighting System and Active Daylighting System. Louver, Screen and use of window's character is representative ways of passive system. Reflection mirror, optical pipe and optical fiber is representative method of active system. Introducing day light on which place can't be introduced day light by typical method is important advantage of active system. Except introducing day lighting methods, efficient lighting management system can save lighting energy. It called lighting automation system. Representatively, Occupancy-related automation and Brightness-related automation system is that. According to occupancy and introducing daylighting level properly operate lamp's intensity of illumination that can save lots of energy. Though Introducing daylighting method, effective lighting system we can get proper intensity of illuminance level and energy saving.

  • PDF

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

Electric lighting energy saving through the use of a Fresnel lens based fiber-optic solar lighting system : Simulation and measurements (광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감 : 시뮬레이션 및 실측 비교)

  • Jeong, Haejun;Kim, Wonsik;Kim, Yeongmin;Han, Hyun Joo;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.34-44
    • /
    • 2017
  • This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

The Study of the Optical Current Sensor Using Magneto-Optic Effects (자기광학효과를 이용한 광전류센서에 관한 연구)

  • 전재일;이정수;송시준;정철우;박원주;이광식;김정배;김민수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.47-53
    • /
    • 2003
  • In this paper, we described the laboratory layout of the optical CT in connection with the measurement of large current based on Magneto-Optic Effects. It was used He-Ne laser for light source and was used PIN-Photodiode for light receiver. The sensing section was organized by winding optical fiber around conductor on the concept that the rotation angle of polarizing axis by Faraday Effect is proportional to the applied current in to conduction. The optical signal passed through optical fiber sensor was induced to analyzer arranged in the direction of $\theta$ for input polarization, and then analyzed its rotation angle and researched on operating characteristics of optical CT for 60[Hz] AC current measurement from l00[A] to 1000[A] was carried out. In this results, the output signals induced linearly with the current and proved that the intensity is increased with increasing turns of fiber through output differences which in accordance with turns of fiber and we verified that there is not only difference of the output with the medium between electric field and optical fiber, but also the lineality. Measuring the references and output intensities of the optical CT, ratio errors were within $\pm$7%. This confirmed that error rate will be improved by each medium and turns.