• Title/Summary/Keyword: 제작방법

Search Result 9,982, Processing Time 0.042 seconds

Effects of the mascara and eye shadow on theMR image distortion (자기공명영상 왜곡에서 마스카라와 아이섀도의 영향)

  • Lee, Hyun-Yong;Shin, Oun-Jae;Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Purpose : To evaluate the degree of the artifact which is caused by the mascara and the eye shadow when acquiring MR images and compare the difference of the image distortion according to the change of various pulse sequence. Material and Method : The popular domestic mascara and eye shadow products were selected from three different companies respectively and divided into two groups mascara (M1, M2, M3 ), eye shadow (E1, E2, E3). Self-designed quadrature type saddle coil which has 4 cm inside diameter, 8 cm length and which is for both Tx and Rx was used. MR image was acquired respectively after applying the mascara to the tape from study 1, the eye shadow to the tape from study 2 and adding the eye shadow to the mascara from study 3. The FSE(fast spin echo), the SE(spin echo), the GE(gradient echo) were used as pulse sequences. The degree of the image distortion which was measured from each sequence was analyzed in quality and quantity. Result : The mascara and the eye shadow caused the artifacts to the MR images partially and induced the image distortion. There was a little difference in terms of the degree of artifact according to the change of pulse sequence. From the study 3 in which the eye shadow was applied to the mascara, on the axial plane image, the width of artifact was 16.73 mm in the GE pulse sequence, 6.64 mm in the SE pulse sequence, and 6.19 mm in the FSE pulse sequence. The degree of the artifact appeared highly in order of the GE, the SE and the FSE. On the sagittal plane image, the length of artifact was 22.84 mm in the GE, 17.81 mm in the SE and it appeared highly with the SE and the FSE technique order. Conclusion : When examining the eyeball and the brain of a woman with the mascara and the eye shadow, we have to consider that the artifact caused by them can have an effect on the image diagnosis. We concluded that it is more suitable for a brain and a eyeball T2 emphasizing image to use the FSE technique than the GE technique.

  • PDF

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Analyses of Genetic Relationships of Rhizoctonia solani Isolates from Various Crop Species and Rapid Identification of Anastomosis Groups with RAPD Method (각종 작물에서 분리한 R. solani 균주들의 RAPD를 이용한 종내 그룹의 유전적 유연관계 분석 및 AGs 신속 간이동정)

  • Lee, Youn-Su;Choi, Hei-Sun;Kim, Kyoung-Su;Woo, Su-Jin;Kang, Won-Hee;Kim, Myoung-Jo;Shim, Jae-Ouk;Lee, Min-Woong
    • The Korean Journal of Mycology
    • /
    • v.26 no.3 s.86
    • /
    • pp.373-379
    • /
    • 1998
  • Rhizoctonia solani [Thanatephorus cucumeris (frank) Donk], one of the major soil-borne plant pathogens with world-wide distribution, can cause great damages on various crops. In Korea, sheath blight on rice caused by this pathogen is the major concern, and active studies on this pathogen have been performed. However, most of these studies were concerned with pathogenicity of the isolates instead of molecular analyses of different AGs of R. solani. Therefore, in this study, thirty isolates of Rhizoctonia solani collected from various sources were used for the analyses of genetic relationships among themselves and for the rapid anastomosis grouping with RAPD method. As a result, thirty isolates of known and unknown AGs were grouped into five subgroups and each group included AG-1, AG-2, AG-3, AG-4, and AG-5. RS-1 isolate was found to be closely related to AG-5. Isolates RS-4, RS-14, RS-17, and RS-16 were found to be closely related to AG-2-2(III B). Isolate RS-13 was closely related to AG-4, isolates RS-8 and RS-10 were closely related to AG-1(I B), and isolates RS-7 and RS-21 were closely related to AG-2-2(IV). Isolate RS-19 was closely related to AG-1(I C), and isolates RS-3, RS-5, RS-18, RS-6, and RS-15 were found to be closely related to AG-1.

  • PDF

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

Development of Agrobacterium-mediated Transformation Method for Domestically Bred Chrysanthemum Cultivar 'Moulinrouge' and Genetic Change of Leaf Morphology Using AtSICKLE Gene (아그로박테리움를 이용한 국내개발 국화품종 '무랑루즈'의 형질전환 기술 및 AtSICKLE 유전자를 이용한 엽형 변화 국화 형질전환체 개발)

  • Kim, Yun-Hye;Park, Hyun-Myung;Jung, Ji-Yong;Kwon, Tack-Min;Jeung, Soon-Jae;Yi, Young-Byung;Kim, Gyung-Tae;Nam, Jae-Sung
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.449-455
    • /
    • 2010
  • 'Moulinrouge' was selected as the best regenerating cultivar among 18 different spray-type chrysanthemum cultivars bred in the Gyeongnam Flowers Breeding Research Institute. When the leaf explants from standard- and spray-type chrysanthemum 'Jinba' and 'Moulinrouge' were incubated on MS basal medium supplemented with $0.5mg{\cdot}L^{-1}$ BA and $1.0mg{\cdot}L^{-1}$ NAA, both 'Jinba' and 'Moulinrouge' induced adventitious shoots that can be regenerated into plantlets. Based on these regeneration conditions, we developed an efficient $Agrobacterium$-mediated chrysanthemum 'Moulinrouge' transformation method by using sequential selection of shoots from low ($10mg{\cdot}L^{-1}$) to high ($30mg{\cdot}L^{-1}$) concentrations of kanamycin after co-cultivation of leaf explants with $Agrobacterium$ for 10 days and induction of shoots. All kanamycin resistant plants investigated with genomic PCR analysis carried the report gene, $AtSICKLE$, in their genome. Although expression levels of the report gene in the transgenic plants investigated with RT-PCR were relatively low because of inefficiency of CaMV 35S promoter in chrysanthemum, transgenic lines expressing $AtSICKLE$ efficiently showed leaf epinasty phenotype. We expect that our results will provide a useful method that can perform a high-throughput investigation of genes isolated and studied well in model plants for molecular breeding of chrysanthemum.

INFLUENCE OF THE COLOR OF COMPOSITE RESINS APPLIED TO LINGUAL SURFACE ON THE LABIAL TOOTH COLOR (설측 복합레진 색상이 치아 순측 색상에 미치는 영향)

  • Mun, Seung-Hui;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.309-323
    • /
    • 2009
  • In this study we evaluated the influence of both the thickness of residual enamel and the color of the composite resins applied to lingual surface on the labial surface color. Background plates were made by randomly (A1, A2, A6D, B1, B2, B3, C1, C2, C6D) selected colors of Filtek Supreme (3M ESPE, St. Paul, U.S.A.) composite resin. Crown portion of 9 maxillary central incisors were cut off and embedded with acrylic resin except labial surface. Samples of average thickness of 2.2 mm were obtained after cutting it in a thickness of 2.5 mm from the labial surface and sandpaper polish. The shade of composite resin background was measured using Spectrophotometer ($Spectrolino^{(R)}$, GretagMacbeth, Regensdorf, Switzerland). And CIE $L^{\ast}a^{\ast}b^{\ast}$value of 2.2 mm thickness tooth samples were measured on the 9 composite resin backgrounds. And then, the cutting side of tooth samples was ground to the extent of 1.9 mm, 1.6 mm, 1.3 mm, 1.0 mm and placed on composite resin backgrounds and measured $L^{\ast}a^{\ast}b^{\ast}$values with the same method. In all samples, $L^{\ast}$value and $b^{\ast}$value seemed to have a tendency of decreasing as thickness of tooth sample becomes thinner regardless of background colors (p < 0.05). But, $a^{\ast}$value didn't show the significant differences depending on the thickness.

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Assessment of Compensator Thickness in Proton Therapy (양성자 치료 시 사용되는 Compensator의 Thickness에 대한 적정성 평가)

  • Park, Yong Soo;Jang, Jun Yeong;Cho, Gwang Hyeon;Park, Yong Cheol;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.35-40
    • /
    • 2018
  • Purpose : The range of force differs from the size of proton energy used in our hospital. The compensator enables to change energy size based on distal thickness which also makes changes in dose rate. Therefore, the purpose of this study is to evaluate the effect of changing the thickness of compensator distal on dose range and beam on time. Subject and Methodology : Five low energy patients who have received proton therapy were selected as subjects for this study. Beam on was checked for the selected patients during the existing therapy. After then, the thickness of distal of compensator was increased by 2 cm up to 14 cm through proton therapy plan system(TPS) for comparative analysis. For the evaluation of dose range, the value of the target's conformity index(CI) and the maximum dose of rear side target's organ at risk(OAR) were compared. Furthermore, to evaluate the effect of therapy time, beam on time was compared by making compensator distal in each thickness. Result : The result of homogeneity index and conformity index of the increased compensator distal showed the same level in all patients. The comparison results of OAR of target rear side showed 7 cGy at spine cord of abdomen at maximum, 88 cGy at eyeball's RT lens, 391 cGy at RT lens of nasal cavity 51 cGy at trachea of the mediastinum, and 661 cGy at a small bowl of the pelvis. The comparison results of the beam on time showed a reduction from 126 seconds to 62 seconds for the abdomen, from 105 seconds to 37 seconds for the eyeball, from 187 seconds to 134 seconds for nasal cavity, from 100 seconds to 40 seconds for mediastinum, from 440 seconds to 118 seconds for the pelvis. Conclusion : The research result showed that as the distal thickness of compensator increased, the size of energy increased. In addition, beam on decreased due to the increase of dose rate. It is expected that the result would help reduce the treatment time and increase the convenience of patients if it is applied to liver patients who need respiratorygated therapy and pediatric patients. However, distal penumbra increased as the size energy increased. Therefore, in treating cases where OAR is in the vicinity of the target rear side, the influence of penumbra should be taken into account in adjusting thickness level of the compensator in proton therapy plan.

  • PDF

Factors Affecting Posttraumatic Stress of Emergency Medical Personnels (구급대원의 외상성 스트레스 영향요인)

  • Baek, Mi-Lye
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • This study not only investigates emergency medical personnel's posttraumatic stress(PTS), social support, work burden, and coping style but also identifies related factors which were exerted influence on PTS and active coping method of emergency medical personnels among the firefighters. The data were gathered from 143 emergency medical personnels who were receiving training. The data were collected by IES-R, consisting of twenty-two questions that determine the level of PTS, method used in Cho's research(2000) that deal with work burden, method used in Oh's article (2006) relating to social support, and sixty-two questions that deals with coping methods. Then the data gathered were analyzed using SPSSWIN 14.0 program. PTS of general characteristics showed significant difference in age, marriage status, education, and position. High risk group of PTS was 74(51.7%). Work burden, active and passive coping method, and three symptoms in PTS are significantly high(p=0.000) in high risk group. PTS was correlated with work burden(r=0.508, p=0.000), active coping method(r=0.375, p=0.000), and passive coping method(r=0.505, p=0.000) but not with social support. Related factors of PTS were work burden(0.371) and passive coping method(0.366). Also related factors of high risk group of PTS were work burden(odds ratio=1.064, 95% confidence interval:1.031-1.103) and passive coping(odds ratio=1.050, 95% confidence interval:1.022-1.080). Related factors of active coping method were PTS(0.392) and social support(0.158). To minimize the PTS of emergency medical personnels, the new policy should decrease their work burden and passive coping method and strengthen the social support to encourage active coping method.