• Title/Summary/Keyword: 정형해석

Search Result 305, Processing Time 0.03 seconds

Net Shaping Process to Minimize Cutting amount of Turbocharger Control Plate (터보차저 컨트롤 플레이트의 절삭량 최소화를 위한 정형공정)

  • Yoon, Pil-Hwan;Lee, Seon-Bong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.53-61
    • /
    • 2017
  • Turbocharger is a device for increasing the power of a vehicle engine. The control plate is the main component for fixing the vane of the turbocharger. Now, the control plate is made of austenite steel cutting after the casting process. It has excellent corrosion, heat resistance and mechanical characteristics of material. However, present the process is made by cutting after casting. when cutting is processed after casting, so materials, processing time, and processing energy are lost. Therefore, this study proposes a process to powder compact use of stainless steel Deklak2 and to minimize amount of cutting through net shape process. The mechanical properties of Deklak2 were verified by tensile test, hardness test and relative density measurement, and the governed equation was defined. Also, the curvature radius 1, 2 and the density, affects the shape, were selected as the design parameters, and the best process conditions was proposed through the Taguchi method and the evaluation of SN ratio. And then prototype molds were fabricated and compared with the results of the finite element analysis for the verification, and it was found that the tendency of relative density and dimension was coincided. Therefore, it was found that the amount of cutting can be minimized by only the net shape process after the sintering process and it can be applied to mass production.

Diagnosis and Management of Suspected Deltoid Injury (삼각인대 손상 의심 시 진단과 치료방법)

  • Yang, Sung Hun;Lee, Jun Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.1
    • /
    • pp.16-21
    • /
    • 2022
  • When an ankle lateral malleolar fracture is accompanied by a deltoid ligament rupture without a medial malleolar fracture, such an injury is called a bimalleolar equivalent fracture. This means that even if there is no bony injury on the medial side, there may be functional instability of the ankle joint due to damage to the deltoid ligament. Manual or gravity external rotational stress radiography is used to differentiate an ankle bimalleolar equivalent fracture from an isolated lateral malleolar fracture. If the medial joint gap is widened on the stress radiography, the deltoid ligament injury can be diagnosed, and surgical treatment for fibula fractures is recommended. After open reduction of the fibula fracture (with syndesmotic fixation if needed), a decision on the repair of the deltoid ligament is taken depending on the surgeons' preference and intraoperative findings. The deltoid ligament repair is performed by inserting a suture anchor (or anchors) in the medial malleolus and fixing the deep and superficial deltoid ligaments to the medial malleolus. The only randomized study to evaluate the utility of deltoid ligament sutures in ankle fractures did not support the deltoid ligament suture, but the study itself had many limitations. An appropriately powered, randomized, controlled trial of the deltoid ligament repair with both patient-reported outcome and radiographic outcome evaluation is needed in the future.

Comparion of models and boundary conditions in fluid simulation of high density Inductively Coupled Plasma Sources included ion temperature equation (이온 온도 방정식이 포함된 고밀도 유도결합 플라즈마원 수송 시뮬레이션을 위한 모델 및 경계 조건 비교)

  • Kwon, Deuk-Chul;Yu, D.H.;Lee, J.K.;Yoon, N.S.;Kim, J.H.;Shin, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1924-1926
    • /
    • 2004
  • 여러 그룹의 연구 결과로서 고밀도 유도결합 플라즈마원 유체 수송 시뮬레이션을 위해 다양한 경계 조건을 포함한 여러 가지 모델이 제시되어 왔다. 본 연구에서는 가능한 모델들과 경계 조건을 설정하여 FDM(finite difference method), up wind scheme, power-law scheme, die1ectric relaxation scheme[1]을 기반으로한 1차원 시뮬레이션을 통해 정확성과 수치 해석적 안정성 및 효율성 연에서 비교, 검토하였다.

  • PDF

A Study on Contact Force Analysis of Fixed Outer-Ring Type Epicycloid Plate Gear for Cycloidal Speed Reducer with Friction Effect (외륜 고정형 에피 사이클로이드 감속기의 작용력 해석법에 관한 연구)

  • Chang S.W.;Hong J.P.;Shin J.H.;Kwon S.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1652-1655
    • /
    • 2005
  • All teeth on the cycloidal plate gear exist in the contact motion with rollers and the forces are interacted between roller gears with cycloidal plate gears. So, the contact forces and friction forces must be required to improve the accuracy in design procedures of cycloidal speed reducers. This paper presents a force analysis considered the friction effect approach derived by static force equilibrium condition, geometrical adaptation, instant velocity center method and relative velocity method. Finally, the paper develops CAD-program for the construction of the design automation using the proposed method.

  • PDF

Multiple Slug and Pumping Tests for Quality Enhancement of Hydraulic Parameter Estimates (순간수위변화 및 양수시험을 통한 수리상수 추정의 문제점 분석)

  • 이진용;이강근;정형재;배광옥
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.14-22
    • /
    • 1999
  • Slug and pumping tests have been widely used to obtain hydraulic parameter estimates in the field. Although a variety of sources of error and uncertainty can be involved in the course of the test performance and data analysis, serious considerations on these sources are often neglected. In this study these various sources of error and uncertainty are analyzed or discussed using repeated slug and pumping test data and some guide lines are suggested to improve quality of parameter estimates from the slug and pumping tests.

  • PDF

Two-dimensional Analytic Solution of the Magnetic Field for the Ferrites of DC Magnetron Sputtering Device (DC 마그네트론 스퍼터링 장치의 영구자석에 의한 자기장의 2차원 해석적 해)

  • Yu Dong-Hun;Kwon Deuk-Chul;Lee Jong-Kyu;Yoon Nam-Sik;Kim Jung-Hyung;Shin Yong-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.7
    • /
    • pp.326-331
    • /
    • 2005
  • We obtain analytical expressions the magnetic field of ferrites for DC magnetron sputtering device, which has been widely used for vacuum thin film deposition, and suggested the equation on maximum radius of the magnetic field by analytic solution. Also, the analytic results are compared with some calculations using magnetization elements of right-angled hexahedron.

Automatic Generating Stopword Methods for Improving Topic Model (토픽모델의 성능 향상을 위한 불용어 자동 생성 기법)

  • Lee, Jung-Been;In, Hoh Peter
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.869-872
    • /
    • 2017
  • 정보검색(Information retrieval) 및 텍스트 분석을 위해 수집하는 비정형 데이터 즉, 자연어를 전처리하는 과정 중 하나인 불용어(Stopword) 제거는 모델의 품질을 높일 수 있는 쉽고, 효과적인 방법 중에 하나이다. 특히 다양한 텍스트 문서에 잠재된 주제를 추출하는 기법인 토픽모델링의 경우, 너무 오래되거나, 수집된 문서의 도메인이나 성격과 무관한 불용어의 제거로 인해, 해당 토픽 모델에서 학습되어 생성된 주제 관련 단어들의 일관성이 떨어지게 된다. 따라서 분석가가 분류된 주제를 올바르게 해석하는데 있어 많은 어려움이 따르게 된다. 본 논문에서는 이러한 문제점을 해결하기 위해 일반적으로 사용되는 표준 불용어 대신 관련 도메인 문서로부터 추출되는 점별 상호정보량(PMI: Pointwise Mutual Information)을 이용하여 불용어를 자동으로 생성해주는 기법을 제안한다. 생성된 불용어와 표준 불용어를 통해 토픽 모델의 품질을 혼잡도(Perplexity)로써 측정한 결과, 본 논문에서 제안한 기법으로 생성한 30개의 불용어가 421개의 표준 불용어보다 더 높은 모델 성능을 보였다.

Utility-interactive Photovoltaic Power Generation Systems with BESS for Power quality improvement (계통연계형 태양광 발전시스템의 계통정전시 BESS의 협조를 통한 전력품질개선)

  • Sim, Jun-Bo;Jung, Hyung-Su;An, Hyo-Jin;Kim, Jin-Hyo;Son, Kwang-Myoung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2271_2272
    • /
    • 2009
  • 본 논문에서는 전력품질 개선기능을 갖는 계통연계형 태양광발전과 BESS를 혼용하는 시스템을 제안한다. 계통연계형 태양광 발전시스템에서 전력계통의 정전 시 태양광 발전시스템의 안정도에 미치는 영향이 크기 때문에 확실하고 신속한 전력의 보상은 전체 시스템에 중요한 의미를 가진다. PSCAD를 이용하여 실제 주상 복합단지를 모델로 계통연계형 태양광 발전시스템의 계통정전 시에 BESS의 협조를 통하여 전력 품질을 개선하는 과정을 통하여 계통의 정전 시 부하로 공급되는 전압변동을 관찰하고 대책을 마련한다. 뿐만 아니라 전체 시스템의 현실적 요소를 분석하고 시뮬레이션과의 차이점을 해석한다.

  • PDF

Harmonic Impact Studies of Grid-Connected Photovoltaic Generation System (계통연계 태양광발전시스템 고조파 영향 검토)

  • Lee, Kang-Wan;Jung, Hyong-Mo;Lee, Sang-Min;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1134_1135
    • /
    • 2009
  • 태양광발전 출력은 인버터를 통하여 상업용 전력계통에 연계된다. 소형 태양광발전 전력은 다수의 수용가를 포함하고 있는 기존의 22.9kV 배전선로에 직접 연결되며, 비선형 전력전자소자로 구성된 인버터는 고조파를 발생하게 된다. 본 논문은 태양광발전소 고조파를 실측하여 이를 모델로 연계 전력계통에 미치는 고조파 영향을 전력계통 해석 도구인 소프트웨어로 분석한 것이다.

  • PDF

Effects of the Shape and the Absorption in Reverberation Rooms on the Space Variances of the Sound Pressure Level (잔향실의 형상(치수비)과 내부표면 흡음율이 음압의 공간편차에 미치는 영향)

  • 최석주;장영자
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.65-70
    • /
    • 1999
  • To examine the space variances of the sound pressure level for five different types (normal frequency spacing) of reverberation rooms, simulations were conducted using the Finite Element Method. In case of infinite surface impedance, nonrectangular reverberation rooms showed small Standard Deviations across the band of frequency, and in case of finite surface impedance, ideal rectangular reverberation rooms showed the similar results as those in irregular shaped reverberation rooms.

  • PDF