• Title/Summary/Keyword: 정점주파수

Search Result 34, Processing Time 0.02 seconds

The Microtremor HVSRs in the SW Korean Peninsula I: Characteristics of the HVSR Peak Frequency and Amplification (한반도 남서부의 상시미동 HVSR 연구 I: 정점주파수와 증폭효과의 특성)

  • Jung, Hee-Ok;Kim, Hyoung-Jun;Jo, Bong-Gon;Park, Nam-Ryul
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.541-554
    • /
    • 2010
  • Fifteen min-microtremor data sets were collected at 136 sites from a coastal area of Kunsan and 117 sites from an inland area of Jeonju located in SW Korea, and were analyzed for the HVSR (Horizontal to Vertical Spectral Ratio) of the sites. The microtremor spectra of the coastal area have stronger energy in the lower frequency range from 1-6 Hz than those of the coastal area. This result can be attributed to the effect of the waves and tides in the Keum river and the Yellow sea. Twenty four hours of measurement of the microtremor indicated that the microtremor spectrum correlates with the human activities, but the microtremor HVSR peak was observed consistently at the characteristic frequency for the site. The HVSR peaks were grouped into 4 types -"single peak", "double peak", "broad peak" or "no peak"- based on their shapes. More than 90% of the data sets exhibit peak frequencies ($F_0$) which can be easily identified. The distribution of $F_0$ reveals a close relationship with the topography and local geology of the areas, exhibiting high F0s in the hillside areas and low $F_0s$ in the reclaimed land area. While the amplitudes of microtremor HVSR peak frequencies are less than 4 in the downstream of the inland area, those of the recently reclaimed land in the coastal area are extremely high (more than 10). The results of this study indicate that detailed HVSR studies are essential for the earthquake hazard reduction of reclaimed lands.

Vibration Characteristics of the Oriental Melon by Vibration Test (진동시험에 의한 참외의 진동특성)

  • Kim, Man-Soo;Jung, Hyun-Mo;Kim, Ghi-Seok;Park, Chung-Gil
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.1
    • /
    • pp.29-42
    • /
    • 2005
  • During a long journey of agricultural products from the production area to markets, the quality of agricultural products was always affected by some degree of vibration. The vibration input during the transportation may cause serious agricultural product injury, and this damage is particularly severe whenever the vegetable inside package is free to bounce, and is vibrated at its resonant frequency. The objectives of this study were to determine the resonant frequency of the oriental melon and to investigate the relationships between resonant frequency and physical properties of the oriental melon such as mass, volume and major and minor axes. In this study vibration testing device was constructed to determine the vibration response of the oriental melon in frequency ranges of 5 to 150 Hz. The computer program for controlling the vibration shaker and the function generator and measuring the vibration characteristics of the oriental melon was developed. The ranges of resonant frequency and peak acceleration at resonance of the oriental melon were 51 to 73 Hz and 1.24 to 1.92 G-rms, respectively. The resonant frequency and the peak acceleration decreased with the increase of the sample mass, volume, major and minor axes of the oriental melon. Multiple regression models for resonant frequency and peak acceleration of the oriental melon as a function of mass, major axis and minor axis of the sample were developed and analyzed.

  • PDF

Vibration Characteristics of the Fruit and Vegetables during Transportation (I) - Vibration Charateristics of the Pear by Experimental Analysis - (유통중 청과물의 진동 특성 연구 (I) - 실험적 해석에 의한 배의 진동특성 -)

  • Kim, Man-Soo;Jung, Hyun-Mo;Kim, Ghi-Seok;Park, Chung-Gil
    • Korean Journal of Agricultural Science
    • /
    • v.30 no.2
    • /
    • pp.175-183
    • /
    • 2003
  • Fruit and vegetables are subjected to complex dynamic stresses in the transportation environment. During a long journey from the production area to markets, there is always some degree of vibration present. Vibration inputs are transmitted from the vehicle through the packaging to the fruit. Inside, these cause sustained bouncing of fruits against each other and container wall. These steady state vibration input may cause serious fruit injury, and this damage is particularly severe whenever the fruit inside the package is free to bounce, and is vibrated at its resonance frequency. The determination of the resonance frequencies of the fruit and vegetables may help the packaging designer to determine the proper packaging system providing adequate protection for the fruit, and to understand the complex interaction between the components of fruit when they relate to expected transportation vibration inputs. Instrumentation and technologies are described for determining the vibration response characteristics of the fruits with frequency range 3 to 150 Hz. The computer program for controlling the vibration exciter and the function generator and for measuring the vibration response characteristics of the fruits was developed. The resonance frequency of the pear ranged from 64.5 to 72.2 Hz and the amplitude at resonance was between 1.78 and 2.21 G-rms. The resonance frequency and amplitude at resonance decreased with the increase of the sample mass, and they were slightly affected by mechanical properties such as bioyield deformation and rupture deformation. Regression analysis was performed among the relatively high correlated parameters from the results of correlation coefficient analysis.

  • PDF

특정 주파수 모의신호 발생을 통한 수중음파의 전달손실 측정

  • 나영남
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.112-120
    • /
    • 1992
  • 수심 100m 이하 천해에서 저주파 대역 음파의 전달손실 양상을 규명하기 위해 한국 동해 남부해역 3개 정점에서 특정 주파수 모의신호 발생을 통한 전달손실을 측정하였다. 10개의 특정 주파수에 대해서 연속파(Continuous Wave)를 방생시킬 수 있는 저주파 음원기를 5 kts의 속도로 예인하고, 다시 육상으로 무선전송하여 각 센서에서의 수진준위를 정확하게 보정하였다. 음원으로부터 DIFAR 센서까지의 전달손실은 거리에 대한 Log 함수로 표시할 수 있었으며, 주파수별 전달손실을 비교, 분석한 결과 동해 남부해역에서의 최적 주파수는 800Hz 내외에서 존재하는 것으로 추정된다.

  • PDF

Characteristics of Carbon Nanotube Oscillator for Embedded System (임베디드 시스템을 위한 탄소나노튜브 오실레이터의 특성 해석)

  • Lee, Jun-Ha;Yang, Seung-Won
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.180-183
    • /
    • 2008
  • 탄소 나노 튜브(CNT)들로 구성된 다중벽 탄소 나노튜브 진동은 분자사이의 역학적인 시뮬레이션에 의해 조사되었다. 그 결과는, 벽간의 결합이 주파수 분할을 이끌고 세개의 주파수 제너레이터로써의 2차 함수 벽, 5차 벽, 6차벽으로 된 오실레이터와 직경으로부터 독립적인 적합성 제안을 위해 지속적인 세개의 정점이 있다는것을 보여준다. 더욱이 적어도 MWCNT 진동의 초기의 주파수중 하나는 이중벽진동의 초기주파수보다 낮다.

  • PDF

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

A Study on the Sources of Ambient Sea Noise in the Coastal Water of Pusan (부산 연안에서의 수중소음원에 관한 연구)

  • 김성부
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.2
    • /
    • pp.180-183
    • /
    • 1990
  • The variability of ambient noise with time and water depth is measured in the coastal water of Pusan. The Noise Spectrum levels are relatively high, and have standard deviations amounting to 3 to 4 dB with time and 2 to 3 dB with water depth in the B area of high ship activity. On the other hand, in the A area where shipping is sparse the standard deviations are only 1 to 2 dB with time and water depth respectively. These results show that ship traffic is one of the dominent sources at frequencies greater than 500Hz.

  • PDF

ECG Signal Compression using Feature Points based on Curvature (곡률을 이용한 특징점 기반 심전도 신호 압축)

  • Kim, Tae-Hun;Kim, Sung-Wan;Ryu, Chun-Ha;Yun, Byoung-Ju;Kim, Jeong-Hong;Choi, Byung-Jae;Park, Kil-Houm
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.5
    • /
    • pp.624-630
    • /
    • 2010
  • As electrocardiogram(ECG) signals are generally sampled with a frequency of over 200Hz, a method to compress diagnostic information without losing data is required to store and transmit them efficiently. In this paper, an ECG signal compression method, which uses feature points based on curvature, is proposed. The feature points of P, Q, R, S, T waves, which are critical components of the ECG signal, have large curvature values compared to other vertexes. Thus, these vertexes are extracted with the proposed method, which uses local extremum of curvatures. Furthermore, in order to minimize reconstruction errors of the ECG signal, extra vertexes are added according to the iterative vertex selection method. Through the experimental results on the ECG signals from MIT-BIH Arrhythmia database, it is concluded that the vertexes selected by the proposed method preserve all feature points of the ECG signals. In addition, they are more efficient than the AZTEC(Amplitude Zone Time Epoch Coding) method.

중력이상을 이용한 한반도 모호면 추출에 관한 연구

  • 김정우;조진동;김원균;민경덕;황재하;이윤수;박찬홍;황종선
    • Proceedings of the KSEEG Conference
    • /
    • 2003.04a
    • /
    • pp.258-264
    • /
    • 2003
  • 중력이상 및 수치고도모델을 이용하여 한반도 모호면 심도를 추출하였다 중력이상값은 인공위성고도레이더 관폭값을 주로 이용한 전지구 모델을 이용하여 데이터영역 뿐 만 아니라 주파수영역에서도 자료의 균질성을 확보하였다. 모호면 추출은 Kim et al. [2000a]에 의해 제안된 스펙트럼 대비법 및 후리에급수를 이용한 파워스펙트럼분석법을 이용하였다. 전자는 지각근형을 전제로, 지형에 의한 중력효과와 후리에어 중력이상을 파동수영역에서 대비하여 모호면의 심도를 계산하는 방법이고, 후자는 완전부우게 중력이상으로부터 푸리에변환을 이용하여 지하 밀도 변화층의 심도를 계산하는 방법이다. 이 두 모호면은 서로 0.53의 상관관계를 갖고 있으며, 이는 모호면 산출의 방법론적인 차이 및 계산상의 오차인 것으로 사료된다. 이렇게 두 가지 독립적인 방법으로 추출된 모호면을 하나로 통합하기 위한 한 방법으로, 두 모호면의 차이를 계산한 후, 이를 최소자승법을 이용, 두 모호면을 보정하였다. 결과적으로 한반도의 최종 모호면의 평균심도는 32.0km, 표준편차는 2.5km 이며, 최소, 최대 심도는 20.3, 36.6km으로 나타났다. 이 경우 지형에 의한 중력효과는 스펙트럼대비법에 의해 제거된 결과이나, 한반도의 지각이 완전한 지각판 내에 놓여 있어서 Airy-Heiskanin 지각균형설의 가정이 타당성이 있는가, 혹은 국부적인 응력장에 의해 한반도의 지각이 과연 얼마나 지지되고 있는가 하는 것에 대한 추가적인 연구가 필요하며, 이에 앞서, 일정한 밀도차를 갖는 연속적인 밀도변화층이 존재한다는 가정이 반드시 필요하다.에는 관련성을 갖고 있으며, 이는 유류 분해정도를 파악하는 지시자로써 특정 무기 오염물질을 이용할 수 있을 가능성이 있으므로 좀더 이들 관계성에 대한 연구가 진행될 필요성이 있다고 판단된다.고 과학적으로 분석할 수 있는 방법이 될 수 있을 것으로 기대된다. 의미를 되새기는 것으로 짧은 연구를 시작하겠다. 등은 활성 값이 70% 이상으로 퇴적물 독성이 상대적으로 낮았다. 이중나선 DNA 함량은 28.4 % - 49%로 대조군에 비해서 감소가 크다. 대부분의 정점이 대조군의 30% 내외로 정점 간의 차이는 크지는 않다. 그러나 다른 측정자료와 같이 정점 22에서 18%로 최소치를 나타내고, 정점 2, 12에서 20% 내외의 값을 보인다. 종합적으로 볼 때 오염물질의 유입이 크고, 광양제철 인근 정점 들이 모두 다른 정점에 비해서 낮아서, 퇴적물 독성이 높은 정점으로 조사되었다.hiwo의 광합성 능력은 낮은 농도들에서는 대조구와 유사하였으나, 5 $\mu\textrm{g}$/l의 높은 농도에서는 초기에 매우 낮은 광합성 능력을 보이다가 시간이 경과하면서 대조군보다 더 높은 경향을 나타냈다. 이러한 결과는 식물플랑크톤이 benso[a]pyrene의 낮은 농도에서 노출될 때는 이 물질을 탄소원으로 사용할 가능성이 있음을 시사한다. 본 연구의 결과들은 연안해역에 benso[a]pyrene과 같은 지속성 유기오염물질이 유입되었을 때 내정여부에 따라 식물플랑크톤 군집내 종 천이와 일차생산력에 크게 영향을 미칠 수 있음을 시사한다.TEX>5.2개)였으며, 등급별 회수율은 각각 GI(8.5%), GII

  • PDF

Effects of Transmittance of Diffusive Blur on Visual Acuity and Contrast Sensitivity (확산적 흐림의 투과율이 시력과 대비감도에 미치는 영향)

  • Yang, Seok-Jun;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.355-362
    • /
    • 2015
  • Purpose: To investigate the effects of the transmittance of diffusive blurson visual acuity and contrast sensitivity. Methods: Visual acuity and contrast sensitivity were measured by using Optec$^{(R)}$ 6500 in Healthy 30 subjects aged $22.83{\pm}0.50$ (male 13, female 17) who were recruited from university students. Cataract simulator was used as a tool for diffusive blur. Visual acuity and contrast sensitivity were measured with varying the transmittance of diffusive blur in order to simulate progression of cataract and concentration in fog. Results: Visual acuity was reduced proportionally with decreasing the transmittance of the diffusive blur as follows: $VA(T)=1.84{\times}10^{-2}T-0.645$. Contrast sensitivity was decreased in all spatial frequencies. Contrast sensitivity in a high spatial frequency band was a greater effect and was off the normal range of contrast sensitivity. The peak of contrast sensitivity was moved in the direction to low frequency. From an intersection point of contrast sensitivity function, we could calculated the transmittance of the diffusive blur being off the normal range and the shift to peak spatial frequency. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd at transmittance of about 78.70%, the contrast sensitivities for all frequencies at transmittance of about 69.71% were deviated from the normal range. Conclusions: The transmittance of diffusive blur causes a reduction in visual acuity and contrast sensitivity, a deviation of normal range of contrast sensitivity, and a shift of peak contrast sensitivity. Therefore the more attention is required when suffering from cataracts or driving in fog.