• Title/Summary/Keyword: 정적 하중 재하실험

Search Result 89, Processing Time 0.021 seconds

A Study on the Static and Dynamic Characteristics of Raised Girder Bridges (양각 거더교의 정적·동적특성에 관한 연구)

  • Ji-Yeon Lee;Sung Kim;Sung-Jin Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.851-858
    • /
    • 2023
  • Purpose: A study was conducted to ensure the structural safety of a raised girder bridge with improved cross-sectional efficiency compared to the conventional PSC girder. For this purpose, the cross-sectional specifications such as girder length, height, and width were determined, the arrangement of the tendons was designed, and the practical performance of the raised girder under static and dynamic loads was verified. Method: The static performance experiment examined the serviceability limit state by measuring behavioral responses such as deflection and cracking to primary and secondary static loads. In addition, the dynamic load loading experiment measured the acceleration and displacement behavior response over time to calculate the natural frequency and damping ratio to examine the usability limit state. Result: As a result of the static performance test, the deflection value based on the maximum applied load showed stable behavior, and the crack width measured at the maximum applied load level was very small, satisfying the serviceability limit state. In addition, a natural frequency exceeding the natural frequency calculated during the design of the dynamic loading experiment was found, and a damping ratio that satisfies the current regulations was found to be secured.

Estimation of Flexural Rigidity of R/C Beam Strengthened with CFS subjected to repeated loadings (반복하중을 받는 CFS로 보강된 R/C 보의 휨 강성 평가)

  • Kim, Chung-Ho;Jang, Jong-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.231-238
    • /
    • 2004
  • The deterioration of the flexural capacity by progressive crack and over deflection in R/C bridges is developed actually from the dynamic repeated loading due to vehicle traffics. Such a fact suggest a necessities of confirmation and estimation of the data acquired from monotonic incremental loading test. Therefore, this study carry out the monotonic incremental loading test and dynamic repeated loading test in R/C beams strengthened with CFS. By dynamic repeated loading test, the experiments confirmed the validities and fittness of the results acquired from monotonic incremental loading test and estimated the characteristics of the moment-curvature, degradation of the flexural rigidity, crack and failure.

Mechanical Performance Evaluation of RC Beams with FRP Hybrid Bars under Cyclic Loads (FRP 하이브리드 보강근을 가지는 RC보의 반복하중에 대한 역학적 성능 평가)

  • Hwang, Chul-Sung;Park, Jae-Sung;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • In the present work, a mechanical performances under cyclic loading in RC (Reinforced Concrete) beams with normal steel and FRPH (Fiber Reinforced Plastic Hybrid) bar are investigated. For the work, RC beam members with $200{\times}200{\times}2175mm$ of geometry and 24 Mpa of design strength are prepared, and 4-point-bending tests are performed for evaluation of cracking, yielding, and ultimate loads. Through static loading test, 48.9kN and 36.0 kN of yielding loads are measured for normal RC and FRPH beam, respectively. They have almost same ultimate load of 50.0 kN. Typical tension hardening behavior is observed in FRPH beam, which is caused by the behavior of FRPH bar with tension hardening. In cyclic loading conditions, FRPH beam has more smaller crack width and scattered crack pattern, and it shows more elastic recovery than normal RC beam. The energy dissipation ratio in FRPH beam is 0.83, which is greater than 0.62 in normal RC beam and it shows more effective resistance to cyclic loadings.

Beam Tests for Static and Fatigue Interface Shear Strength between Old and Njew Concretes (신구콘크리트 계면의 전단강도 측정을 위한 정하중 및 피로하중 보실험)

  • 최동욱
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.3
    • /
    • pp.137-147
    • /
    • 1997
  • Interface shear strength of' concrete under static loading and deterioratiion of interface strength by fatigue loading in shear were experimentally investigated using composite beam test specimens. Thirteen beams were constructed. Five composite beams were tested statically until interface delaminations were observed in the static tests. Seven composite beam and one monolithically cast beam were subjected to two to three million cycles of fatigue load. Test variables were interface roughness, interface shear reinforcement, and presence of interface bond. The average interface shear strength of the composite beams with bonded-rough interface was 6, 060 kPa. No interface delamination was observed after cycling for the composite beams with bonded - rough interface and interface bond was not influenced by repeated application of the shear stress of 2.000 kPa(about 1/3 of the static interface shear strength). Smooth interface and unbonded-rough interface with shear reinforcement deteriorated under repeated shear loading.

Development of Short-span Precast Concrete Panels for Railway Bridge (철도교용 단지간 프리캐스트 콘크리트패널의 개발)

  • Seol, Dae-Ho;Lee, Kyoung-Chan;Kim, Ki-Hyun;Youn, Seok-Goo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.545-553
    • /
    • 2016
  • This paper presents experimental static test results of the precast concrete panels developed for short-span concrete bridge deck form. Different from LB-DECK, concrete rib attached to the bottom surface of concrete panel, and Top-bar is not used at the top surface of concrete panel. Number of concrete ribs and cross-section details of concrete rib are determined from the analytical results of parametric study considering the span length and the thickness of concrete bridge decks. Shear rebars are installed at the top surface of concrete panel for composite action between precast concrete panel and cast-in-place concrete. In order to evaluate the safety and the serviceability of the developed short-span concrete panel subjected to design load, static load test is conducted. Three test panels with span length of 1.6m are fabricated, and during the load test displacements, strains and cracks of test panels are measured and final failure modes are investigated. Serviceability of the test panels is evaluated based on the results of displacements, cracking load, and crack width at the design load level. Safety is also evaluated based on the comparison of the ultimate strength and the factored design load of test panels. Based on the test results, it is confirmed the short-span precast concrete panel satisfies the serviceability and safety regulated in design codes. In addition, the range of span length of concrete bridge decks for the short-span concrete panel is discussed.

Structural Performance Analysis of New Type CFTA Girder Bridge (신형식 CFTA 거더 교량의 구조성능평가)

  • Lee, Ji-O;Jeong, Min-Chul;Park, Kyung-Hoon;Kong, Jung-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • In this research, static load test is performed to verify the arch effect and structural performance of CFTA(Concrete-Filled and Tied steel tubular Arch) girder, and FE(Finite Element) analysis is performed to investigate validity of the test result. CFTA girder is designed to maximize the benefit of each material, such as steel plate, filled concrete and PS tendon. Static load test is performed based on the frame-analysis result of 12m sample miniature model. The result of static load test is that structural performance and safety of CFTA girder are confirmed and there is different deflection mode with other structural form result from arch effect. FE analysis with ABAQUS is also performed to show the validity of the truck collision safety and static load test.

A Study on Static Behavior of 60 m span Half-Decked PSC Girder (Half-Deck을 포함한 60 m 경간 PS 콘크리트거더의 정적 거동 연구)

  • Kim, Tae Min;Park, Jong Heon;Kim, Moon Kyum;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.65-73
    • /
    • 2012
  • In this study, we tested structural performance of Half-Decked PSC girder which was developed for applying to long span bridge. We operated 4 point bending test with 60 m span full scale girder designed as simple bridge with hinge-roller boundary condition. Actuators were set on the both sides of girder, 5.5 m away from the center, and 4 stages of cyclic loading was applied at rate of 1 kN/sec. Through stages 1 to 4, loading and unloading 1,000 kN, 1,200 kN, 1,500 kN, and 2,000 kN were repeated and displacement, strain of concrete and steel, crack of girder were checked. From these results, the strength of girder was assessed and resilience and ductility were observed after removing the load. Since initial flexural crack occurred in the vicinity of 1,400 kN, non-linearity of load-displacement curve appeared and definite residual strain was measured at that point. The test result showed that initial cracking load was over twice the DB-24 load which means the developed girder had sufficient strength. To verify the experimental results, we numerically analyze the test and confirmed that the data were similar with results from the test above. Half-Decked PSC type of 60 m-girder developed in this study showed its adequate structural capacity through static loading test, which proved that possibility of applying the girder to actual bridges practically.

Behavior Analysis of Ultra-Thin Whitetopping in Field (얇은 콘크리트 덧씌우기 포장의 거동 평가)

  • Kang, Jang-Hwan;Jang, Jin-Yen;Koo, Han-Mo;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.6 no.1 s.19
    • /
    • pp.25-36
    • /
    • 2004
  • The total length of paved roads in Korea is 67,265 Km, and among these roads, about 40% of the national highways and 98% of local roads are paved with asphalt concrete. The major distress to asphalt pavement is rutting and fatigue crack. The permanent deformation including rutting accounts for about 75% of this distress. UTW(Ultra-Thin Whitetopping), which is known for its high-quality performance in asphalt pavement with rutting and cracking, seems to reduce maintenance costs significantly if it is used as the maintenance/repair method for domestic asphalt pavement. In the research, static load test was conducted to establish a behavior of Whitetopping under traffic and environmental condition. It showed that the effect of the thickness of the concrete layer and the temperature change was significant. In addition, the tensile strain as the wheel load position was close to interior and edge of concrete slab were increased up to 75% of maximum tensile strain. It showed that joint spacing must be considered in UTW design procedure.

  • PDF

Experimental Study on Behaviors of Prestressed Concrete Beam Reinforced by Prestressed External Tendon (단면 보강용 외부 긴장 강선을 사용한 프리스트레스트 콘크리트 보의 거동에 관한 실험적 연구)

  • Park, Chan-Sol;Kim, Kee-Dong;Han, Taek-Hee;Latif, Abdul;Kim, Doo-Kie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.222-229
    • /
    • 2022
  • The extensive use of external prestressing system with PSC-I beam to strengthen reinforced and prestressed concrete members requires the full understanding of the behavior of the strengthened members. The main approach of this research was to experimentally investigate the flexural performance of the PSC-I beam considering external tendon and an equation was developed which indicated the produced incremental stress in the tendon due to applied load. Further, this equation was verified through performing static loading tests on two experimental specimens considering the presence or absence of external tendon. The test results revealed that, the flexural performance enhanced due to the use of external tendon. Moreover, the magnitude of the estimated flexural strength using proposed stress increasing equation almost coincides with the experimental test results. However, it was the evident of the improvement of the flexural performance of the system by reinforcing with the external tendon and also proved that the proposed equation was valid and effective.

Experimental Study on the Inelastic Behavior of Single-layer Latticed Dome (단층 래티스 돔의 비탄성 거동에 대한 실험연구)

  • Kim, Jong-Soo;Kim, Sang-Dae;Kim, Myeong-Han;Oh, Myoung-Ho;Shin, Chang-Hoon
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.165-170
    • /
    • 2008
  • This study discusses the inelastic behavior of single-layer latticed dome, composed of tubular truss member and newly proposed joint sections, through loading test on the scale-down structure. The loading test was performed under displacement control conditions, using loading transfer system for the same value of point loads on all joints. Maximum applied load was nearly 1.6 times of the design load, and inelastic buckling occured beyond compressive yeilding in some members. The displacement of structure was maimtained upto the limit of oil jack. The behavior of latticed dome from the loading test was analyzed on the view of structural design practice.

  • PDF