• Title/Summary/Keyword: 정적 전단하중

Search Result 143, Processing Time 0.028 seconds

Inelastic Behavior of Reinforced Concrete Frame Structure with Shear Strength of Masonry Wall (조적벽의 전단강도를 고려한 철근콘크리트골조의 비탄성 거동)

  • Yoon, Tae-Ho;Kang, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4216-4222
    • /
    • 2011
  • In this study the inelastic behavior of the existing school buildings with infilled masonry walls is analysed by pushover method. The shear stiffness and strength of masonry wall is calculated from the prior experimets and verified by inelastic analysis. The height of infilled masonry wall affects the structural behavior. The higher the masonry wall height, the higher the initial shear stiffness and strength of masonry wall. As the cracks are developed, the strength of masonry wall is much decreased. The proposed inelastic analysis method shows similar results with the experiments and can be used as inelastic analysis model of reinforced concrete buildings with infilled masonry walls.

Nonlinear Analysis of RC Bridge Columns for Ductility Evaluation (철근콘크리트 교각의 연성도 평가를 위한 비선형해석)

  • 손혁수;이재훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.39-49
    • /
    • 2003
  • This research is a part of a research program to develope a new design method for reinforced concrete bridge columns under axial load and cyclic lateral load. A nonlinear analytical method is proposed to obtain moment-curvature relationship and lateral load-displacement relationship. Various analytical models that contribute seismic behavior of reinforced concrete bridge columns are adopted and modified by comparing quasi-static test results of reinforced concrete columns with spirals of circular hoops. The analysis adopts confined concrete model, longitudinal reinforcement test result of reinforced concrete columns with spirals or circular hoops. The analysis adopts confined concrete model, etc. The results obtained using the propose analytical method agree well with test results and give conservative estimations particularly for deformation capacity and ductility.

Seismic Performance of Piloti-Type Structures with Columns Strengthened with Aramid Fiber Sheets (아라미드 섬유시트로 기둥 보강된 필로티 구조물의 내진성능 평가)

  • Keun-Hyeok Yang;Ju-Hyun Mun;Chae-Rim Im;Kwang-Geun Rho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.201-210
    • /
    • 2023
  • This study is to evaluate the ductility strengthening effect of aramid fiber sheets on piloti-type structures. Two piloti-type structure specimens were prepared and tested under statical cyclic lateral loads. The ductility strengthening effect was validated from the analysis of lateral load-displacement relationship, displacement ductility ratio, work damage index and torsion behavior. Test results showed that the post-peak behavior of piloti-type structures with columns strengthened with aramid fiber sheets tended to be ductile resulting from preventing shear failure and minimizing torsion due to the effective lateral confinement of column concrete by aramid fiber sheet. Consequently, the displacement ductility ratio and work damage index of piloti-type structures with columns with strengthened with aramid fiber sheets were 4.63 and 42.81 times higher than those of non strengthened piloti-type structures.

A Study on Brace-height Ratio for Seismic Retrofit of School Building (학교 건축물의 내진 보강을 위한 가새 - 높이비에 관한 연구)

  • Lee, Hwa-Jung;Byon, Dae-Kun;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.10-17
    • /
    • 2020
  • The recent earthquake in Korea caused large and small damages to many school building. School building is an important building that is used as a shelter in the event of disaster. Among the seismic retrofit methods, the internal steel braced frame type method is used for its relatively easy construction and excellent performance. In this study, the maximum shear force and displacement were compared and examined by applying the brace frame to existing concrete school buildings. As a result, we verified the adequacy of the analytical model and compared and examined the effect of brace-height ratio on the span of the existing school buildings. The adequacy of the maximum shear force and displacement relationship can be confirmed in the model with a length of 0.3. In addition, seismic frame was applied to the actual non-seismic reinforced concrete school building, and the seismic performance was evaluated by nonlinear static analysis(Push-over analysis) according to the ratio of brace-height. As a result, the increase of the brace-height according to the brace-height ratio has the effect of increasing the maximum shear force and maximum load at the performance point. But the collapse of the braced frame due to the increase in the lateral stiffness occurred, indicating that seismic retrofit according to the proper brace-height is necessary. Therefore, in the seismic retrofit design of brace frame of existing school building, it is necessary to select the proper brace-height after retrofit analysis according to the brace-height ratio.

Failure Pressure Prediction of Composite T-Joint for Hydrodynamic Ram Test (수압램 시험을 위한 복합재 T-Joint의 파손 압력 예측)

  • Kim, Dong-Geon;Go, Eun-Su;Kim, In-Gul;Woo, Kyung-Sik;Kim, Jong-Heon
    • Composites Research
    • /
    • v.29 no.2
    • /
    • pp.53-59
    • /
    • 2016
  • Aircraft wing structure is used as a fuel tank containing the fluid. Fuel tank and joint parts are consists of composite structure. Hydrodynamic Ram(HRAM) effect occurs when the high speed object pass through the aircraft wing or explosion and the high pressure are generated in the fuel tank by HRAM effect. High pressure can cause failure of the fuel tank and the joint parts as well as the aircraft wing structure. To ensure the aircraft survivability design, we shall examine the behavior of the joint parts in HRAM effect. In this study, static tensile tests were conducted on four kind of the composite T-Joints. The failure behavior of the composite T-joint was examined by strain gauges and high speed camera. We examine the validity of the Finite Element Modeling by comparing the results of FEA and static tensile tests. The failure stresses and failure pressure of the composite T-Joint were calculated by FEA.

Assessment of Slip Sinkage of an Off-Road Tracked Vehicle from Model Track Experiments (모형궤도시험을 통한 야지궤도차량의 슬립침하 평가)

  • Baek, Sung-Ha;Shin, Gyu-Beom;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.49-59
    • /
    • 2018
  • When a tracked vehicle travels off-road, shearing action and ground sinkage occur on the soil-track interface and severely affect tractive performance of the tracked vehicle. Especially, the ground sinkage, which is induced by vehicle's weight (hereinafter referred to as static sinkage) and longitudinal forces in the direction of travel producing slip (hereinafter referred to as slip sinkage), develops soil resistance, directly restricting the tractive performance of an off-road tracked vehicle. Thus, to assess the tractive performance of an off-road tracked vehicle, it is imperative to take both of static sinkage and slip sinkage into consideration. In this research, a series of model track experiments was conducted to investigate the slip sinkage which has not been clarified. Experiment results showed that the slip sinkage increased with increasing the slip ratio, but the increasing rate gradually decreased. Also, the slip sinkage was found to increase as relative density of soil decreased and imposed vertical load increased. From the experiment results, the normalized slip sinkage defined as slip sinkage to static sinkage calculated in the identical condition was investigated, and an empirical equation for the slip sinkage was developed in terms of slip ratio, which allows vehicle operators to predict the slip sinkage in a given soil and operating conditions.

Pushover Analysis of a Five-Story Steel Framed Structure Considering Beam-to-Column Connection (보-기둥 접합부를 고려한 5층 철골골조구조물의 비탄성 정적해석)

  • Kang, Suk-Bong;Lee, Jae-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.129-137
    • /
    • 2010
  • In this study, a five-story steel frame was designed in accordance with KBC2005 to evaluate the effect of the beam-column connection on the structural behavior. The connections were designed as a fully rigid connection and as a semirigid connection. A fiber model was utilized to describe the moment-curvature relationship of the steel beam and column, and a three-parameter power model was adopted for the moment-rotation angle of the semirigid connection. To evaluate the effects of higher modes on structural behavior, the structure was subjected to a KBC2005-equivalent lateral load and lateral loads considering higher modes. The structure was idealized as a separate 2D frame and as a connected 2D frame. The pushover analysis of 2D frames for the lateral load yielded the top displacement-base shear force, design coefficients such as overstrength factor, ductility ratio, and response modification coefficient, demanded ductility ratio for the semirigid connection,and distribution of plastic hinges. The sample structure showed a greater response modification coefficient than KBC2005, the higher modes were found to have few effects on the coefficient, and the lateral load of KBC2005 was found to be conservative. The TSD connection was estimated to secure economy and safety in the sample structure.

Dynamic response of segment lining due to train-induced vibration (세그먼트 라이닝의 열차 진동하중에 대한 동적 응답특성)

  • Gyeong-Ju Yi;Ki-Il Song
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.4
    • /
    • pp.305-330
    • /
    • 2023
  • Unlike NATM tunnels, Shield TBM tunnels have split linings. Therefore, the stress distribution of the lining is different even if the lining is under the same load. Representative methods for analyzing the stress generated in lining in Shield TBM tunnels include Non-joint Mode that does not consider connections and a 2-ring beam-spring model that considers ring-to-ring joints and segment connections. This study is an analysis method by Break-joint Mode. However, we do not consider the structural role of segment lining connections. The effectiveness of the modeling is verified by analyzing behavioral characteristics against vibration loads by modeling with segment connection interfaces to which vertical stiffness and shear stiffness, which are friction components, are applied. Unlike the Non-joint mode, where the greatest stress occurs on the crown for static loads such as earth pressure, the stress distribution caused by contact between segment lining and friction stiffness produced the smallest stress in the crown key segment where segment connections were concentrated. The stress distribution was clearly distinguished based on segment connections. The results of static analysis by earth pressure, etc., produced up to seven times the stress generated in Non-joint mode compared to the stress generated by Break-joint Mode. This result is consistent with the stress distribution pattern of the 2-ring beam-spring model. However, as for the stress value for the train vibration load, the stress of Break-joint Mode was greater than that of Non-joint mode. This is a different result from the static mechanics concept that a segment ring consisting of a combination of short members is integrated in the circumferential direction, resulting in a smaller stress than Non-joint mode with a relatively longer member length.

A Study Shear Behavior of Reinforced Concrete Beams Mixed Steel Fiber (강섬유(鋼纖維)를 혼입(混入)한 철근(鐵筋)콘크리트 보의 전단학동(剪斷學動)에 관(關)한 연구(硏究))

  • Kwak, Kae Hwan;Lee, Kwang Myong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.4
    • /
    • pp.1-8
    • /
    • 1991
  • Recently the use of steel fibers has been increased in flexural members and columns of concrete structures subjected to cyclic loadings; such as bridge decks, highway roads, runway of airport, buildings, etc.. However only a few experimental tests have been carried out under fatigue loading. In the present study, the reinforced concrete beams with 1% and 2% steel fiber volume fraction are investigated with and without stirrups. It has been found that in fatigue tests, the failure of the beam is usually due to breaking of fibers rather than fiber pull-out. A comparison of experiments and numerical analysis using the nonlinear F.E.M. program (ADINA) is also presented herein.

  • PDF

Experiment Study on Shear Behavior of Polymer Concrete Beams (폴리머 콘크리트의 보의 전단거동에 관한 실험적 연구)

  • 곽계환;박종건;한휘남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.4
    • /
    • pp.39-47
    • /
    • 1994
  • This research focuses on producing a cheap polymer, and also experiments for marking with the high strength polymer concrete structures. At present only a few tests on shear behavior in polymer reinforced concrete beams(PRC) have been reported. In the current experiments, the reinforced concrete beams with polymer fraction are investigated. The beams in this study are supported by conventional stirrups at appropriate intervals and they are designed to take static loads. The strength of beams are measured and the behavior of beams under each loading are oh served in order to determine some advantages of adding polymer to reinforced concrete beams. The static testing data consist of load, displacement, and strain at specified reinforcement locations, and the support displacement In the static tests, it has been observed that the beams fail in the same way as RC. However, it is observed to he rather weak in impact, hut it can he said that its increase of strength and excellency of repairing are verified. Consequently this work strongly suggests that the steam-curing or the air-curing or the air-curing must be performed to increase the strength.

  • PDF