• Title/Summary/Keyword: 정적인장

Search Result 147, Processing Time 0.018 seconds

Tensile Properties of Hybrid Fiber Reinforced Cement Composite according to the Hooked & Smooth Steel Fiber Blending Ratio and Strain Rate (후크형 및 스무스형 강섬유의 혼합 비율과 변형속도에 따른 하이브리드 섬유보강 시멘트복합체의 인장특성)

  • Son, Min-Jae;Kim, Gyu-Yong;Lee, Sang-Kyu;Kim, Hong-Seop;Nam, Jeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.31-39
    • /
    • 2021
  • In this study, the fiber blending ratio and strain rate effect on the tensile properties synergy effect of hybrid fiber reinforced cement composite was evaluated. Hooked steel fiber(HSF) and smooth steel fiber(SSF) were used for reinforcing fiber. The fiber blending ratio of HSF+SSF were 1.5+0.5, 1.0+1.0 and 0.5+1.5vol.%. As a results, in the cement composite(HSF2.0) reinforced with HSF, as the strain rate increases, the tensile stress sharply decreased after the peak stress because of the decrease in the number of straightened pull-out fibers by increase of micro cracks in the matrix around HSF. When 0.5 vol.% of SSF was mixed, the micro cracks was effectively controlled at the static rate, but it was not effective in controlling micro cracks and improving the pull-out resistance of HSF at the high rate. On the other hand, the specimen(HSF1.0SSF1.0) in which 1.0vol.% HSF and 1.0vol.% SSF were mixed, each fibers controls against micro and macro cracks, and SSF improves the pull-out resistance of HSF effectively. Thus, the fiber blending effect of the strain capacity and energy absorption capacity was significantly increased at the high rate, and it showed the highest dynamic increase factor of the tensile strength, strain capacity and peak toughness. On the other hand, the incorporation of 1.5 vol.% SSF increases the number of fibers in the matrix and improves the pull-out resistance of HSF, resulting in the highest fiber blending effect of tensile strength and softening toughness. But as a low volume fraction of HSF which controlling macro crack, it was not effective for synergy of strain capacity and peak toughness.

Failure Analysis of Deteriorated Reinforced Concrete T-Girder Bridge Subject to Cyclic Loading (정적 반복하중을 받는 노후된 철근콘크리트 T형교의 파괴해석)

  • 송하원;송하원;변근주
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.291-301
    • /
    • 1998
  • In this paper, two dimensional and three dimentional modeling techniques are proposed for the failure analysis of deteriorated reinforced concrete T-girder bridge subjected to cyclic loading up to failure. For the nonlinear failure anaysis, a tension stiffening model which can consider degradation of bond between reinforcement and surrounding concrete due to corrision of rebars in old bridge is proposed and a modeling technique for the supports conditions of the bridges which can consider degradation of bearing at supports in old bridge is also proposed, The analysis results along with comparisons with full-scale failure-test results confirm that finite element modeling techniques in this paper can be well applied to the failure analyses of in-situ old reinforced concrete T-girder bridges subjected to cyclic loading and the support condition modeling especially affects the bridge strength significantly.

Static Tensile Strength Evaluation of Notched Coeposite Materials (노치를 갖는 복합재료의 정적강도평가(I))

  • 김윤해;김영식;서곡홍신
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.19-29
    • /
    • 1993
  • The static tensile tests of GFRP, ID300, CFRID300 and CFRPEEK were made on the plain and notched specimens at room temperature. The results were discussed based on linear notch mechanics which was proposed by H.Nistani. The fracture of notched GFRP, ID300, CFRID300 and CFRPEEK specimens is controlled by the elastic maximum stress, $({\sigma}_max)$, and the notch root racius,$\rho$, alone, independently of the other geometrical conditions. The relation between fracture nominal stress,$({\sigma}_max)$, and stress concentration factor, $K_t$ and a part where $({\sigma}_c)$ is nearly constant independent of $K_t$. A similar phenomenon can be seen in the fatigue tests of notched specimes under rotating bending or push-pull. The almost constant $({\sigma}_c)$ values correspond to the nearly constant apparent stress intensity factor, $K_{1pc}$ values, obtained by assuming ,$\rho$=0. This can be attributed to the existence of the stable crack. Linear notch mechanics is very useful for analyzing the static tensile fracture behavior of notched GFRP, ID300, CFRPEEK specimens.

  • PDF

The Behavior of Silt due to Volume Deformation Tendency (체적변형 경향에 따른 실트의 거동)

  • Jeong, Sang Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.5
    • /
    • pp.255-260
    • /
    • 1993
  • The behavior of pure silt was investigated by using an automated triaxial testing device. The stress-strain behavior of silt due to the volume deformation tendency was compared with the behavior of clay prior to failure and behavior at failure under monotonic undrained compression and extension conditions. A pure silica flour was chosen to form samples. The isotropically normally-consolidated samples with 450 kPa of effective mean confining pressure and overconsolidated samples through unloading were tested. Based on the experimental results, it was qualitatively identified that the undrained strength of normally-consolidated silt increases due to its dilatant nature which is not seen in clay. Also the overconsolidated silt shows a significantly different behavior under the monotonic loadings due to the volume deformation tendency.

  • PDF

A Study on the 43$0^{\circ}C$ Degradation Behavior of Cast Stainless Steel(CF8M)(I);Evaluation of Degradation mechanism, Static and Fatigue Strength (주조 스테인리스강 CF8M의 43$0^{\circ}C$ 열화거동에 관한 연구(I);열화기구.정적 및 피로강도평가)

  • Gwon, Jae-Do;Park, Jung-Cheol;Lee, Yong-Seon;Lee, U-Ho;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.1910-1916
    • /
    • 2000
  • The five classes of the thermally aged CF8M specimen are prepared using an artificially accelerated aging method. Namely, after the specimens are held for 100, 300, 900, 1800, and 3600hrs at 430$^{\circ}C$ respectively, the specimens are water-cooled to room temperature. The impact energy variations are measures for both the aged and virgin specimens through the Charpy impact tests in addition to the microstructure observation, tensile, hardness and fatigue crack growth tests. From the present investigation the following results are obtained : 1) The difference among the thermally degraded specimens can be distinguished through their microstructures, 2) Hardness and tensile strength are increased to 300hrs, degradation specimen, while elongation and reduction area are decreased to 3600hrs degradation specimen, and impact energy is decreased to 1800hrs degradation specimen, 3) The FCG rates for thermally degraded specimens are larger than that of the virgin specimen.

The strain measurement on the aluminum alloy welded transition joint (알루미늄 合金 異材熔接部의 變形率測定)

  • 옹장우;전제춘;오상진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.625-634
    • /
    • 1986
  • The strain distribution on a welded aluminum alloy transition joint produced by a static tensile load has been measured using a moire method combined with photoelastic coating method. The test specimens were made of aluminum alloy 6061-T6 and 2014-T6 butt welded with ER-4043 filler metal, and were post welded heat treated (solid solution heat treatment 502.deg. C 70min.) and precipitated (artificial aging 171.deg. C 600min.) to cause an abrupt change of mechanical properties between the base metals and weld metal. The photoelastic epoxy rubber was cemented on the specimen grating which had been reproduced on the specimen surface by using an electropolishing. The measurements were compared with strains computed by Finite Element Analysis. The following results were abtained. (1) The maximum strain were distributed along the center line in the transverse directiion of the weld metal. (2) The strain gradient along the fusion line increased approaching the V-groove tip and the maximum value was observed at a quarter of width from the V-groove tip. (3) The moire method combined with photoelastic coating was proved very useful for real time strain measurement in the welded aluminum alloy transition joint.

Analysis on the Bonded Single Lap-Joint Containing the Interface Edge Crack (에지계면균열을 갖는 단순겹치기 접착이음의 강도평가)

  • Yoo, Young-Chul;Park, Jung-Hwan;Lee, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.6
    • /
    • pp.159-166
    • /
    • 1998
  • The problem of interface crack in the bonded structures has received a great deal of attention in recent years. In this paper the aluminum bonded single lap-joint containing the interface edge crack is investigated. The tensile load and the average shear stress of the adhesive joints which have different crack length are obtained from the static tensile tests. The critical value of crack length to provoke the interface fracture is determined to a/L=0.4, where a is the interface crack length and L is the adhesive lap-length. The fracture mechanical parameters are introduced to confirm the existence of the critical crack length. The compliance and the stress intensity factors are calculated using the displacement and the stress near the interface crack tip by the boundary element method. These numerical results support the experimental results that the critical value of a/L is 0.4. It is known that the compliance and the stress intensity factors are the efficient parameters to estimate the bonded single lap-joint containing the interface edge crack.

  • PDF

Fatigue Life Evaluation of Spot Weldments of SPC Sheet Including Strain Rate Effect (변형률속도효과를 고려한 일반냉연강판 점용접부의 피로수명평가)

  • Song, Joon-Hyuk;Nah, Seok-Chan;Yu, Hyo-Sun;Kang, Hee-Yong;Yang, Sung-Mo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.48-53
    • /
    • 2006
  • A methodology is described for predicting the fatigue life of the resistance spot weldment including strain rate effect. Because it is difficult to perform a physical failure test with high strain rate, an analytical method is necessary to get the mechanical properties of various strain rate, To this end, quasi-static tensile-shear tests at several strain rate were performed on spot weldments of SPC. These test provided the empirical data with the strain rate. With these results, we formulated the function of fatigue life prediction using the lethargy coefficient which is the global material property from tensile test. And, we predicted the fatigue life of spot weldment at dynamic strain rate. To confirm this method for fatigue life prediction, analytical results were compared with the experimental fatigue data.

The Minimum Lap-spliced Length of the Reinforcement in the Steam Curing UHPC Bridge Deck Slab Joint (UHPC 바닥판 증기양생 현장이음부의 최소철근겹침이음길이)

  • Hwang, Hoon-Hee;Park, Sung-Yong
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2013
  • The static test was performed to verify the effect of the joint in the UHPC bridge deck slab and the minimum lap-spliced length was presented. A total of six test members was fabricated to estimate the static behavior of the steam curing UHPC bridge deck slab joint by the four points bending test method. The lap-spliced joint type was expected to be not only simple but also efficient in UHPC structure because of the high bond stress of UHPC. Test results show that the decrease of maximum flexural strength was about 30% and the minimum lap-spliced length which behaved similar to the continued reinforcement in strength and ductility was 150 mm.

Experimental Evaluation on Structural Performance of Large Diameter Reinforcing Steel Bars with Spliced Sleeves (대구경 기계적 철근 이음장치의 구조성능에 관한 실험적 평가)

  • Kwon, Ki Joo;Park, Dong Su;Joung, Won Seoup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.180-188
    • /
    • 2011
  • Recently a number of researches about mechanical splice have been studied to apply on a large diameter reinforcing steel bars of spliced sleeves. In this study the structural performance of large diameter reinforcing bars with spliced sleeves was evaluated. For the application of nuclear power plant structures, two different types of existing splices with #11, 14, 18 rebars were fabricated and static and dynamic test were performed on the basis of ASME SEC III DIV.2CC-4330.