• Title/Summary/Keyword: 정원계획

Search Result 221, Processing Time 0.027 seconds

A Study on the Basic Direction of Housign Product Development Considering the Characteristics of Urban Townhouse (도시형 타운하우스의 특성을 고려한 주택상품개발의 기본 방향에 관한 연구)

  • Seong, Ki-Seon
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.77-89
    • /
    • 2020
  • Nowadays, urban townhouses are being developed in various forms according to the characteristics of different regions in consideration of the trends of the housing market. Misperceiving the needs of consumers or their characteristics as a house for living, however, they often end up becoming products that are not suitable for urban life or degraded on account of reckless regional development. It is so unfortunate that such trial and error keeps being repeated. Urban townhouses are advantageous because there is no such problem as either invasion of privacy or noise from neighbors, and it is possible to have one's own garden and enlarged parking space, obtain quality of grounding, and plan unique interior and exterior design. They are also equipped with the strengths of apartment houses as well, for example, the efficiency of joint control in crime and disaster prevention or security, architecture of diaphragm walls with the separation of gates, or the planning of common space like a central square or park. Therefore, there is a great chance that they can be developed as the types of urban housing. Accordingly, the purpose of this study is to establish the basic direction of developing housing products right as space for urban life and maximize the roles of urban townhouses. By understanding their spatial as well as functional elements as a house for living, this author aims to provide a guideline for housing product development to realize urban townhouses that can meet consumer needs.

A Study on the Promotion Plan of the 2032 South-North Korea Joint Olympics (2032 남북공동올림픽 추진방안 연구)

  • Lee, Dong-Hee;Kim, Heung-Tae
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.8
    • /
    • pp.353-379
    • /
    • 2020
  • The 2032 South-North Joint Olympics is an agreement between the two Koreas. Through this, various efforts are needed to improve new inter-Korean relations and co-prosperity on the Korean Peninsula. The purpose of this study is to proceed with the 203 South-North Joint Olympics. This study was developed by literature reserch methods. The result of this study are as follows. First, Seoul-Pyongyang soccer exchange game will be promoted. Second, the International Peace Cup a relay race(Marathon) will be held. Third, Korea Peace Cup International Table Tennis Championships will be held. Fourth, I propose holding the Korea Sports Science Forum. Fifth, about 16-17 events are propose for North Korea to host the 2032 South-North Joint Olympics. Sixth, the decision to host the 2032 Summer Olympics is expected in 2022 or 2023. Seventh, it is necessary to promote the Inter-Korean Social Association cultural Exchange and Cooperation Committee or the Special Committee for the Promotion of the Inter-Korea Sports Exchange and Cooperation. Eighth, it is necessary to implement a five-year plan to promote Inter-Korea sports Exchange Cooperation or a five-year plan for Inter-Korea sports Exchange and Cooperation. Ninth, the North Korea player registration system will be promote to the South Korean K-1 League. Ten, suggest sports exchange and cooperation ahead of time. Eleventh, train experts on North Korean sports or exchange and cooperation. Finally, the South-North Korea sports exchange Agreement will be promoted. It also promotes the Inter-Korea sports Exchange and Cooperation Support Act.

Establishment of a Conservation Plan for Colony of Selaginella involvens (Sw.) Spring (부처손 군락지 보존계획의 수립)

  • Hong, Kwang-pyo;Kim, Inhye;LEE, Hyukjae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.449-455
    • /
    • 2022
  • The Colony of Selaginella involvens (Sw.) Spring in Sanyang-myeon, Mungyeong-si, can be divided into five types, and in the past, it was said that Selaginella involvens (Sw.) Spring formed colonies throughout the colony and grew naturally, but now it remains only in some sections. It was found that the Selaginella involvens (Sw.) Spring colony was damaged by artificial and natural factors, and as an artificial factor, the Selaginella involvens (Sw.) Spring was proven to be effective for medicinal and cremation, and many people were damaging the Selaginella involvens (Sw.) Spring colony without permission. Naturally, vines thrive and Selaginella involvens (Sw.) Spring die, and the reality is that the entire colony of Selaginella involvens (Sw.) Spring is in danger of being damaged if maintenance is not performed. On the other hand, there are sections that reproduce with symbiosis with some herbaceous plants, so it is necessary to plan and implement conservation strategies. In order to preserve the Selaginella involvens (Sw.) Spring colony, CCTV is needed to prevent artificial damage, and on the contrary, install facilities such as fences can easily burn up and create worse scenery, so it can preserve the good environment, restore recoverable areas, and install supplementary buffer zones.

The Existence and Design Intention of Jeong Seon's True-View Landscape Painting <Cheongdamdo(淸潭圖)> (겸재 정선(謙齋 鄭敾) <청담도(淸潭圖)>의 실재(實在)와 작의(作意))

  • SONG Sukho;JO Jangbin ;SIM Wookyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.2
    • /
    • pp.172-203
    • /
    • 2023
  • <Cheongdamdo>(true-view landscape painting) was identified in this study to be a folding screen painting painted by Jeong Seon(a.k.a. Gyeomjae, 1676~1759) in the 32nd year of King Yeongjo(1756) while exploring the Cheongdam area located in Mt. Bukhansan near Seoul. Cheongdam Byeol-eop(Korean villa), consisting of Waunru Pavilion and Nongwolru Pavilion, was a cultural and artistic base at that time, where Nakron(Confucian political party) education took place and the Baegak Poetry Society met. <Cheongdamdo> is a painting that recalls a period of autumn rainfall in 1756 when Jeong Seon arrived in the Cheongdam valley with his disciple Kim Hee-sung(a.k.a. Bulyeomjae, 1723~1769) and met Hong Sang-han(1701~1769). It focuses on the valley flowing from Insubong peak to the village entrance. The title has a dual meaning, emphasizing "Cheongdam", a landscape feature that originated from the name of the area, while also referring to the whole scenery of the Cheongdam area. The technique of drastically brushing down(刷擦) wet pimajoon(hanging linen), the expression of soft horizontal points(米點), and the use of fine brush strokes reveal Jeong Seon's mature age. In particular, considering the contrast between the rock peak and the earthy mountain and symmetry of the numbers, the attempt to harmonize yin and yang sees it regarded as a unique Jingyeong painting(眞境術) that Jeong Seon, who was proficient in 『The Book of Changes』, presented at the final stage of his excursion. 「Cheongdamdongbugi」(Personal Anthology) of Eo Yu-bong(1673~1744) was referenced when Jeong Seon sought to understand and express the true scenery of Cheongdam and the physical properties of the main landscape features in the villa garden. The characteristics of this garden, which Jeong Seon clearly differentiated from the field, suppressed the view of water with transformed and exaggerated rocks(水口막이), elaborately creating a rain forest to cover the villa(裨補林), and adding new elements to help other landscape objects function. In addition, two trees were tilted to effectively close the garden like a gate, and an artificial mountain belt(造山帶), the boundary between the outer garden and the inner garden, was built solidly like a long fence connecting an interior azure dragon(內靑龍) and interior white tiger(內白虎). This is the Bibo-Yeomseung painting(裨補厭勝術) that Jeong Seon used to turn the poor location of the Cheongdam Byeol-eop into an auspicious site(明堂). It is interpreted as being devised to be a pungsu(feng shui) trick, and considered an iconographic embodiment of ideal traditional landscape architecture that was difficult to achieve in reality but which was possible through painting.

A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient (3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰)

  • Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.

  • PDF

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

Examinations on Applications of Manual Calculation Programs on Lung Cancer Radiation Therapy Using Analytical Anisotropic Algorithm (Analytical Anisotropic Algorithm을 사용한 폐암 치료 시 MU 검증 프로그램 적용에 관한 고찰)

  • Kim, Jong-Min;Kim, Dae-Sup;Hong, Dong-Ki;Back, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 2012
  • Purpose: There was a problem with using MU verification programs for the reasons that there were errors of MU when using MU verification programs based on Pencil Beam Convolution (PBC) Algorithm with radiation treatment plans around lung using Analytical Anisotropic Algorithm (AAA). On this study, we studied the methods that can verify the calculated treatment plans using AAA. Materials and Methods: Using Eclipse treatment planning system (Version 8.9, Varian, USA), for each 57 fields of 7 cases of Lung Stereotactic Body Radiation Therapy (SBRT), we have calculated using PBC and AAA with dose calculation algorithm. By developing MU of established plans, we compared and analyzed with MU of manual calculation programs. We have analyzed relationship between errors and 4 variables such as field size, lung path distance of radiation, Tumor path distance of radiation, effective depth that can affect on errors created from PBC algorithm and AAA using commonly used programs. Results: Errors of PBC algorithm have showned $0.2{\pm}1.0%$ and errors of AAA have showned $3.5{\pm}2.8%$. Moreover, as a result of analyzing 4 variables that can affect on errors, relationship in errors between lung path distance and MU, connection coefficient 0.648 (P=0.000) has been increased and we could calculate MU correction factor that is A.E=L.P 0.00903+0.02048 and as a result of replying for manual calculation program, errors of $3.5{\pm}2.8%$ before the application has been decreased within $0.4{\pm}2.0%$. Conclusion: On this study, we have learned that errors from manual calculation program have been increased as lung path distance of radiation increases and we could verified MU of AAA with a simple method that is called MU correction factor.

  • PDF