• Title/Summary/Keyword: 정보재

Search Result 6,876, Processing Time 0.031 seconds

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

How Customer Experience Management in the Hotel Industry can Lead to a Willingness to Pay More (호텔 기업의 고객경험관리(CEM)는 기꺼이 더 지불하게 하는가?)

  • Choi, Wook-Hee
    • Culinary science and hospitality research
    • /
    • v.22 no.7
    • /
    • pp.267-280
    • /
    • 2016
  • Customer Experience Management (CEM) appeared as a complementary solution to overcome CRM limitations. CEM enhances profitability through building long-term relations with customers by understanding their experiences. This study aims at investigating the impact of customer experience quality on the willingness to pay more through customer satisfaction in the hotel businesses. The survey for this study was carried out on customers who had domestic hotel experience s within the last 6 months. Out of the 306 questionnaires retrieved, 225 valid responses were used for the empirical analysis that utilizied the statistical package programs SPSS 18.0 and AMOS 18.0. The research findings may be summarized as follows. First, as an outcome of the research hypothesis that each component of customer experience management would influence satisfaction, 'the peace of mind' & 'the moment of truth' were shown to have a significantly positive (+) impact on it. On the other hand, 'the product experience' was shown not to significantly influence it in a positive (+) way. Second, as an outcome of the research hypothesis that satisfaction would influence willingness to pay more. From the findings of the study, theoretical implications are as follows. It can be predicted that customer experience management will likely make customers more profitable because customers are willing to pay more with a sense of loyalty built through satisfaction of the hotel industry. In the practical implications, the dimension of experience quality examined by the study can be used as an index to measure and manage customer experience in the hotel industry.

Comparisons of Attitude on Media's Report for Avian Influenza between Poultry Breeder and Non-breeder (언론의 조류인플루엔자 보도에 대한 조류사육업자와 비사육업자의 태도 비교)

  • Oh, Gyung-Jae
    • Journal of agricultural medicine and community health
    • /
    • v.34 no.1
    • /
    • pp.58-66
    • /
    • 2009
  • Objectives: Active participation of poultry breeder in surveillance system of Avian Influenza (AI) is very important. Therefore this study was conducted to present basis data for active report of AI that is affected by media's coverage in poultry breeder. Methods: Subjects were 88 persons, 28 who were poultry breeder at epidemic area of AI and 60 who were general person at non-epidemic area. Data were collected by the trained investigator from Jul. 1 to Aug. 31, 2008. Respondents were interviewed by means of a structured questionnaire. Results: The third-person effect among perceptions of influence in media's report on the AI was higher in breeder (32.1%) than in non-breeder (10.0%). However, Confidence to media report on the AI was lower in breeder than in non-breeder. Intention to report of the AI was 71.4% in breeder respectively, was 90.0% in non-breeder. There was statistically significant lower in breeder than non-breeder. The cause of avoidance of report was 'economic damage' for 87.5%, which acocounted for the majority of cases. Confidence to media report on the AI were positively correlated with concern on the AI and perception on seriousness of the AI, but negatively correlated with the third-person effect. Conclusions: These results showed that intention to report of the AI of breeder was susceptible to influenced by the third person effect and confidence in media's report on the AI. Therefore we should give a special attention to increase active report of poultry breeder during epidemic period of AI which is consideration of reasonable strategy of media's coverage, including mind and emotion state of poultry breeder.

An Influence of the Korean Wave on Chinese Tourism to South Korea (중국인의 방한관광에 대한 한류의 영향)

  • Choi, Kyung-Eun
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.4
    • /
    • pp.526-539
    • /
    • 2007
  • The purpose of this study is to investigate the influence of the Korean Wave on Chinese tourism to South Korea through a behavioral analysis of Chinese tourists in the general group package tours. China suppressed the needs of the Chinese people's geographical movement and imposed restrictions on information about the outside world with the use of a policy of "closure" for a long time. But since reforms and open-door policies were introduced in China, especially in the context of relaxation of control policies over Chinese outbound tourism after the mid-1990's, more and more Chinese make trips abroad including visits to South Korea. In this situation, the recent Korean Wave(especially, drama/film) describes the Korean national image by forming a bridge between fiction and reality and plays a pivotal role in broadening or reconstructing the geographical imagination of the Chinese people who have been historically isolated from the outside world. Although Chinese have imagined the Korean nationscape on the basis of geopolitical or economic factors in the past, they have currently broadened or reconstructed their geographical imagination to include socio-cultural factors related closely to the Korean way of life due to the recent Korean Wave. This newly constructed geographical imagination led by the Korean Wave functions as an important pulling factor in Chinese destination choices, affecting Chinese tourists' motivation formation and the recommendation of main attractions. The more influential the Korean Wave is on their destination choice, the more the respondents select the cultural factors in both their motivation for tourism to South Korea and their recommendations of tourism attractions to other people. Through the analysis results of both satisfaction and intention to revisit, the more influential the Korean Wave is on their destination choice, the higher is the degree of both satisfaction and intention to revisit. In other words, although Chinese tourism to South Korea is chiefly in the general group package tours, Chinese tourists who are influenced by Korean Wave on their destination choice have more attachment to(or affection for) Korea as a tourism destination. This result suggests that the Korean Wave affects qualitative change - that is, change of attitude - as well as quantitative change in Chinese demand for tourism to South Korea.

Relationships between Fatty Acids and Tocopherols of Conventional and Genetically Modified Peanut Cultivars Grown in the United States (미국산 전통품종과 유전자 재조합 땅콩품종의 지방산과 토코페롤의 상관관계)

  • Shin, Eui-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1618-1628
    • /
    • 2013
  • Relationships between fatty acids and tocopherols in conventional and genetically modified peanut cultivars were studied by gas chromatography with flame ion detector and high performance liquid chromatography with fluorescence detection. Eight fatty acids and four tocopherol isomers in the sample set were identified and quantified. Oleic acid and linoleic acid are major fatty acids and the ratio of oleic and linoleic acids ranged from 1.11 to 16.26. Tocopherols contents were 6.76 to 12.24 for ${\alpha}$-tocopherol (T), 0.08 to 0.39 for ${\beta}$-T, 5.28 to 15.02 for ${\gamma}$-T, and 0.17 to 1.17 mg/100 g for ${\delta}$-T. Correlation coefficient (r) for fatty acids and tocopherols indicated a strong inverse relationship between oleic & linoleic acids (r=-0.97, P<0.05) and positive relationships between palmitic & linoleic acids (r=0.95, P<0.05) and ${\gamma}$-T & ${\delta}$-T (r=0.83, P<0.05). Principal component analysis (PCA) of fatty acids and tocopherols gave four significant principal components (PCs, with eigenvalues>1), which together account for 85.49% of the total variance in the data set with PC1 and PC2 contributing 45.27% and 21.33% of the total variability, respectively. Eigen analysis of the correlation matrix loadings of the four significant PCs revealed that PC1 was mainly contributed by palmitic, oleic, linoleic, and gondoic acids, while PC2 was by behenic acid, ${\beta}$-T, and ${\gamma}$-T. The score plot generated by PC1-PC2 identified sample clusters in the two spatial planes based on the oleic and linoleic acids. The score plot PC3-PC4 didn't separate sample groups.

Prevalence of Obesity and Its Relationship to Diet on Elementary Students (학동기 아동의 비만유병률과 체중조절 실태에 관한 연구)

  • Rho, Young-Ill;Kim, Kang-Ho;Yang, Eun-Seok;Park, Young-Bong;Park, Sang-Kee;Park, Jong;Moon, Kyung-Rye
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.2
    • /
    • pp.181-187
    • /
    • 2000
  • Purpose: The purpose of our study is to provide useful information for the prevalence of obesity by the standard weight for height and the relationship of the body image to dieting methods for weight control in children. Methods: The survey was performed by an anthropometry and a special questionnaire on children in grades 5 to 6 at elementary schools from May to June 1997 in Kwangju city. Results: 1) Selected individuals were categorized into obese, normal, thin by the standard weight for height and body image. The prevalence of obesity by the standard weight for height was 19.5%, normal was 70.5%, thin was 10.1% in males and respectively 10.5%, 66.3%, 23.1% in females. The prevalence of obesity in regards to body image was 18.4%, normal was 58.4%, thin was 23.2% in males and respectively 24.5%, 58.6%, 16.9% in females. 2) The obese body image was 6.8% in normal and thin groups in males and 19.4% in females. The body image of obese children who do not perceive themselves as obese was 32.6% in males and 28.7% in females. 3) The standard body image was 88.8% as realized by themselves, 77.9% when they compared themselves to friends, 62.7% as told by parents, 56.8% as told by friends, and 29.9% when they compared themselves to celebrities. 4) The source of information for dieting treatment was 44% from radio and television, 30% from books, newspapers, magazines, 17% from family and 9% from friends and seniors. 5) The prevalence of dieting according to the standard weight for height was 18.0% in thin, 18.7% in normal and 36.7% in obese group in males and respectively 17.8%, 22.4%, 46.3% in females. There was a statistically significant correlation between males and females (p<0.0005). 6) The prevalence of dieting up to 2 weeks in the thin and normal groups as recognized by weight centile was 17.3% according to body image. The prevalence of dieting up to 2 weeks in the obese groups was 37.2% according to body image (p<0.001). Conclusion: We suggest that many students perceived their body size incorrectly and tried weight control. The incorrect perception of body size seems to cause the problem of failure to thrive, malnutrition etc. It is necessary for further study to find and prevent side effects by unnecessary weight control and to provide proper health education and management about obesity.

  • PDF

Identification of the Pig β-1,3-N-acetylglucosaminyltransferase 1 (pB3GNT1) that is Involved in Poly-N-acetyllactosamine (poly-LacNAc) Synthesis (Poly-N-acetyllactosamine (poly-LacNAc) 합성에 관여하는 돼지 β-1,3-N-acetylglucosaminyltransferase I (pB3GNT1) 유전자 동정)

  • Kim, Ji-Youn;Hwang, Hwan-Jin;Chung, Hak-Jae;Hochi, Shinichi;Park, Mi-Ryung;Byun, Sung June;Oh, Keon Bong;Yang, Hyeon;Kim, Kyung-Woon
    • Journal of Life Science
    • /
    • v.28 no.4
    • /
    • pp.389-397
    • /
    • 2018
  • The structure of glycan residues attached to glycoproteins can influence the biological activity, stability, and safety of pharmaceutical proteins delivered from transgenic pig milk. The production of therapeutic glycoprotein in transgenic livestock animals is limited, as the glycosylation of mammary gland cells and the production of glycoproteins with the desired homogeneous glycoform remain a challenge. The ${\beta}$-1,3-N-acetylglucosaminylatransferase1 (B3GNT1) gene is an important enzyme that attaches N-acetylglucosamine (GlcNAc) to galactose (Gal) residues for protein glycosylation; however, there is limited information about pig glycosyltransferases. Therefore, we cloned the pig B3GNT1 (pB3GNT1) and investigated its functional properties that could attach N-acetylglucosamine to galactose residue. Using several different primers, a partial pB3GNT1 mRNA sequence containing the full open reading frame (ORF) was isolated from liver tissue. The ORF of pB3GNT1 contained 1,248 nucleotides and encoded 415 amino acid residues. Organ-dependent expression of the pB3GNT1 gene was confirmed in various organs from adult and juvenile pigs. The pB3GNT1 mRNA expression level was high in the muscles of the heart and small intestine but was lower in the lungs. For functional characterization of pB3GNT1, we established a stable expression of the pB3GNT1 gene in the porcine kidney cell line (PK-15). As a result, it was suggested that the glycosylation pattern of pB3GNT1 expression in PK-15 cells did not affect the total sialic acid level but increased the poly N-acetyllactosamine level. The results of this study can be used to produce glycoproteins with improved properties and therapeutic potential for the generation of desired glycosylation using transgenic pigs as bioreactors.

Current Status and Problems of PET/CT Data on CD for Inter-hospital Transfer (병원간 전송용 PET/CT 영상 CD자료의 현황 및 문제점)

  • Hyun, Seung-Hyup;Choi, Joon-Young;Lee, Su-Jin;Cho, Young-Seok;Lee, Ji-Young;Cheon, Mi-Ju;Cho, Suk-Kyong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: This study was performed to find the current problems of positron emission tomography/computed tomography(PET/CT) data on CD for inter-hospital transfer. Materials and Methods: The subjects were 746 consecutive $^{18}F$-fluorodeoxyglucose PET/CT data CDs from 56 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data CDs were reviewed and the email questionnaire survey about this was performed. Results: PET/CT data CDs from 21 of 56 hospitals(37.5%) included all transaxial CT and PET images with DICOM standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. According to this survey, the main reason of limited PET/CT data on CD for inter-hospital transfer was that the data volume of PET/CT was too large to upload to the Picture Archiving and Communication System. Conclusion: The majority of hospitals provided limited PET/CT data on CD for inter-hospital transfer, which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data on CD for inter-hospital transfer including all transaxial CT and PET images with DICOM standard format.

Usefulness of the Salivagram for the Diagnosis of Brain Lesions in Patients with Aspiration Pneumonia (뇌병변 환자에서 흡인성 폐렴 진단을 위한 Salivagram의 유용성)

  • Oh, Shin Hyun;Choi, Yung Sook;Ro, Dong Wook;Nam-Koong, Hyuk;Kim, Jae Sam;Leee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: Bed, living a long time is required in adult patients with brain lesions such as stroke, traumatic brain injury, and Parkinson's disease, causing pneumonia and respiratory diseases may be due to aspiration of food or saliva. In patients with recurrent pneumonia or pulmonary symptoms, there is a need to determine the possibility of pulmonary aspiration due to aspiration of saliva. Materials and Methods: Saliva due to aspiration pneumonia diagnosis in patients with brain lesions request for inspection to the Department of Nuclear Medicine, 10 patients (male 6, female 4) were included in this study. Patients were fasted before the test, $^{99m}Tc_{O4}$ 185 MBq (5 mCi) of less than 1 mL of solution was administered in the oral cavity. Administration and 20 minutes of dynamic imaging acquisition, and immediately after that the static images were acquired. Delayed scan after 2-4 hours if necessary. Results: Positivity rate of all 10 patients was 60%. In 4 patients showed positive reactions after the administration of oral cavity in a 20-minute dynamic imaging were able to confirm whether the aspiration. In the remaining 2 patients, four hours of additional delay tests were able to confirm whether the aspiration. Conclusion: Does not require changes in patient posture compared to the other checks that can be diagnosed with aspiration pneumonia. A simple test and takes less time. Therefore be useful in providing information for the diagnosis and treatment modality.

  • PDF

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF