• Title/Summary/Keyword: 정밀측정장비

Search Result 296, Processing Time 0.023 seconds

Geotomography Applied for the Integrity Test of Cast-in-place Piles (현장타설콘크리트말뚝의 건전도 평가를 위한 geotomography의 적용 연구)

  • Lee Jae-Kyung;Park Jong-Nam
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.5-12
    • /
    • 2005
  • Recently, geophysical prospecting methods have played very important roles in civil and environmental engineering problems. Technical advances in geophysical instruments and computer system made it possible to get underground images with very high resolution far purposes to resolve those problems. It was possible partly due to ever increasing demand for development of technologies needed to precisely detect polluted areas and prevent ground-related accidents. Based on the same demand, integrity tests of cast-in place piles draw more attention and development of accurate test procedures is required. Ultrasonic methods is one of most advanced non-destructive procedures. In the paper, a geotomography method is employed for the cast-in place pile integrity test using ultrasonic waves. The image of pile interior is scanned and scrutinized far better and more accurate decision in the cast-in place pile integrity. In this study, we firstly examined the accuracy fur tomography program with idealized synthetic models built in water tank: their position and size were changed in the tank and each case was studied. In the next stage, real concrete pile models were fabricated and images of anomaly areas inside the pile were scanned to successfully locate those areas.

The study on the quality characteristics factor of medium-sized orbit scroll (중형 선회 스크롤의 품질 특성 인자에 대한 연구)

  • Kim, Jae-Gi;Lim, Jeng-Taek;Kang, Soon-Kook;Park, Jong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.718-723
    • /
    • 2016
  • The use of the scroll compressor in the air conditioning of medium-sized vehicles has increased because of its low torque fluctuation, high energy efficiency and low noise. In addition, the main components of the compressor have been changed from steel to aluminum to reduce its weight, following studies on the constituent materials. The processing precision of the fixed scroll and orbiting involute scroll wrap of the scroll compressor must be below $10{\mu}m$. To ensure this, the surface roughness and contour tolerance are measured. To improve the hardness of the orbiting scrolls using aluminum subjected to anodizing treatment and as the base material, we used a sealing treatment and measured the resulting characteristics. The aluminum materials were made of an Al-Mg-Cu based alloy including small amounts of Ni, Fe, and Zn. The surface roughness was less than $3{\mu}m$ and the processing accuracy was within $10{\mu}m$. Also, the hardness of the nanodiamonds with CNTs used in the sealing treatment was more than 450. This was found to improve the hardness of the material by 50% or more compared to the water sealing treatment and there was little difference between the use of carbon nanotubes and nanodiamonds as sealing materials.

A Study on an Implementation of Control Panel of Sun Trackers and Monitoring System for Photovoltaic Generation Plants (태양광발전의 태양추적기제어반 및 모니터링시스템 구현에 관한 연구)

  • Lho, Tae-Jung;Park, Min-Yong;Lee, Seung-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3161-3167
    • /
    • 2010
  • Hall sensors of BLDC(brushless DC) motor are used to detect a position information for a control mechanism, which implements an algorithm for velocity and position control. Actual azimuth and altitude were measured to evaluate a control precision. The measurement revealed comparatively good accuracy that the measured values were $2.02^{\circ}$ and $1.01^{\circ}$ respectively, and the maximum error falls within $1.86^{\circ}$. The developed monitoring system of photovoltaic generation plants is a LCU(Local Control Unit) based on an integrated monitoring system which supports 1:N method for multiple simultaneous connections, remote control and real-time system state monitoring.

An Intelligent Robotic Biological Cell Injection System (바이오 셀 조작용 지능 로봇 시스템)

  • Shim, Jae-Hong;Cho, Young-Im;Kim, Jong-Hyeong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.4
    • /
    • pp.411-417
    • /
    • 2004
  • Recently, instruments and systems related on biological technology have been enormously developed. Particularly, many researches for biological cell injection have been carried out. Usually, excessive contact force occurring when the end-effector and a biological cell contact might make a damage on the cell. Unfortunately, the excessive force could easily destroy the membrane and tissue of the cell. In order to overcome the problem, we proposed a new injection system for biological cell manipulation. The proposed injection system can measure the contact force between a pipette and a cell by using a force sensor. Also, we used vision technology to correctly guide the tip of the pipette to the cell. Consequently, the proposed injection system could safely manipulate the biological cells without any damage. This paper presents the introduction of our new injection system and design concepts of the new micro end-effector. Through a series of experiments the proposed injection system shows the possibility of application for precision biological cell manipulation such as DNA operation.

Estimation of Hydrodynamic Derivatives of Submarine Model by Using VPMM Test (VPMM 시험을 이용한 잠수함 모형의 유체력 미계수 추정)

  • Jung, Jin-Woo;Jeong, Jae-Hun;Kim, In-Gyu;Lee, Seung-Keon
    • Journal of Navigation and Port Research
    • /
    • v.38 no.2
    • /
    • pp.97-103
    • /
    • 2014
  • In these days, the world has been increasing navy forces such as aircraft carriers and high-tech destroyers etc. and the importance of submarines is being emphasized. Therefore, accurate values of the derivatives in equations of motion are required to control motion of the submarines. Hydrodynamic derivatives were measured by the vertical planar motion mechanism(VPMM) model test. VPMM equipment gave pure heave and pitch motion respectively to the submarine model and the forces and moments were acquired by load cells. As a result, the hydrodynamic derivatives of the submarine are provided through the Fourier analysis of the forces and moments in this paper.

Experimental Investigation on Hydrodynamic Coefficients of Submarine Model by VPMM Test (VPMM 시험을 이용한 수중 잠수함 모형의 동유체력 계수 추정에 관한 연구)

  • Jung, Jin-Woo;Jeong, Jae-Hun;Kim, In-Gyu;Lee, Seung-Keon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.117-118
    • /
    • 2013
  • In these days, the world have been increasing navy forces such as aircraft carriers and high-tech destroyers etc. and the importance of submarines is being emphasized. Therefore, accurate values of the derivatives in equations of motion are required to control motion of the submarines. Hydrodynamic coefficients were measured by the vertical planar motion mechanism(VPMM) model test. VPMM equipment gave pure heave and pitch motion respectively to the submarine model and the forces and moments were acquired by load cells. As a result, the hydrodynamic coefficients of the submarine are provided through the fourier analysis of the forces and moments in this paper.

  • PDF

Development of Real-time Blood Pressure Monitoring System using Radio Wave (전파를 이용한 실시간 혈압 모니터링 시스템 개발)

  • Jang, Dong-won;Eom, Sun-Yeong;Choe, Jae-Ik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.308-311
    • /
    • 2015
  • Because worldwide interest in the health is increased, the real-time health monitoring system has been demanded to be more convenient non-contact and precise medical devices than conventional. Therefore we developed the blood pressure monitoring system using UWB(Ultra Wide Band) radio wave which contact to the human body through the radar and continuously collect a movement signal of the blood vessel. Then the collected data including pulse rate, systolic blood pressure, diastolic blood pressure is processed in real time. The system monitors and controls through a program-based embedded LCD(Liquid Crystal Display) using Qt GUI(Graphic User Interface) to be displayed in real time. We implement the system as a embedded system because of reducing the size of the limited resources. Existing PC GUI design mode is used relatively large memory, therefore it requires more CPU(Central Processing Unit) capacity and processing time.

  • PDF

Fabrication of the Integrated Triplexer Using Micro Block Stacking Method (Micro-block Stacking 방법으로 제작한 집적형 Triplexer 제작 및 특성 측정)

  • Yoon, Hyun-Jae;Kim, Jin-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.217-221
    • /
    • 2012
  • In this paper, we have fabricated by means of the "Micro-Block Stacking (MBS)" method the 8 pin mini DIL integrated Triplexer, which can transmit CATV and voice/data at the same time in a single fiber. Our MBS technique is a novel scheme of compact optical module packaging which secures precision positioning of the components on the optical beam path by prefixed stacks of ceramic blocks. The subassembly in which a laser diode, two receiver photodiodes, two WDM filters, and four micro lenses are integrated is only $5.40mm{\times}2.15mm{\times}1.05mm$ in size. As the Triplexer is aligned to the single mode fiber, the transmitter power of -14.5 dBm and the receiver sensitivities of 0.83 A/W, 0.73 A/W for 1550 nm, 1490 nm, respectively are obtained.

Femto-second Laser Ablation Process for Si Wafer Through-hole (펨토초 레이저 어블레이션을 이용한 Si 웨이퍼의 미세 관통 홀 가공)

  • Kim, Joo-Seok;Sim, Hyung-Sub;Lee, Seong-Hyuk;Shin, Young-Eui
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.3
    • /
    • pp.29-36
    • /
    • 2007
  • The main objectives of this study are to investigate the micro-scale energy transfer mechanism for silicon wafer and to find an efficient way for fabrication of silicon wafer through-hole by using the femtosecond pulse laser ablation. In addition, the electron-phonon interactions during laser irradiation are discussed and the carrier number density and temperatures are estimated. In particular, the present study observes the shapes of silicon wafer through-hole with $100\;{\mu}m$ diameter and it also measures the heat-affected area and the ablation depths fur different laser fluences by using the optic microscope and the three-dimensional profile measurement technique. First, from numerical investigation, it is found that the nonequilibrium state exists between electrons and phonons during laser irradiation. From experimental results, it should be noted that the heat-affected area increases with laser fluence, and the optimal conditions for through-hole formation with minimum heat affected zone are finally obtained.

  • PDF

Pick & Place Module consist of Linear Motor using Cogging Force Reduction Method (코깅힘 저감 방법을 적용한 선형모터로 구성되는 Pick & Place 모듈)

  • Chung, Myung-Jin
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.735-742
    • /
    • 2020
  • The pick & place module is used as a core module in the process equipment for producing and inspecting semiconductor components. The conventional pick & place module has the disadvantage that the precision and durability of the system are reduced and the size and weight of the module are increased by using a conversion device that converts rotary motion into linear motion. In this study, we proposed a pick & place module that implements up-and-down linear motion without a conversion device by improving such disadvantage and employs a linear motor with no limit on average thrust and travel distance. Design parameter values, that can reduce cogging force while maintaining average thrust by selecting parameters for designing a core type linear motor with a large thrust to volume ratio and analyzing the effect of cogging force according to design parameter changes through magnetic analysis, was selected. Average thrust and cogging force were measured for the pick & place module composed of the manufactured linear motor and compared with the design values.