• Title/Summary/Keyword: 정맥 도관

Search Result 86, Processing Time 0.029 seconds

Fracture of an Implantable Central Catheter Due to Pinch Off Syndrome (Pinch off 증후군에 의한 피하매몰형 중심정맥도관의 절단)

  • Yun, Ju-Sik;Oh, Sang-Gi;Song, Sang-Yun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.504-507
    • /
    • 2008
  • Implantable central venous catheters (Chemoport) are increasingly being used for vascular access, parenteral nutrition and administering chemotherapeutic agents. As with most invasive procedures, central venous catheterization is associated with numerous potential complications such as infection, thoromboembolism and occlusion. A rare but serous complication is the catheter fracture. We present here three cases of catheter fracture as a consequence of Pinch off syndrome, and we include a review of the relevant literature.

Clinical Review of Totally Implantable Venous Catheter (완전 거치형 정맥도관의 임상분석)

  • Kim, Jung-Tae;Oh, Tae-Yoon
    • Journal of Chest Surgery
    • /
    • v.40 no.10
    • /
    • pp.691-695
    • /
    • 2007
  • Background: The introduction of central venous catheters in 1979 has aided the administration of chemotherapy to oncologic patients. We analyzed the clinical reviews and complications of totally implantable venous catheters in an effort to achieve optimal management. Material and Method: We retrospectively studied 100 cases with totally implantable venous catheter at our hospital and we report the results. Result: 100 totally implantable venous catheters were placed in the right subclavian vein in 74 cases (74%), the left subclavian vein in 21 cases, the right jugular vein in 3 cases, the left jugular vein in 1 case and the right femoral vein in 1 case. The immediate complications were 5 cases in malposition of the catheter and 5 cases of arterial puncture. The late complications were 1 case of subclavian vein thrombosis, which was treated with anticoagulation, and 2 cases of pinch-of syndrome. There were no other early or late complications. Conclusion: The low rate of complications in this study confirms the safety and convenience of using totally implantable venous catheter in patients undergoing prolonged chemotherapy. Yet because Infection, thrombosis, and catheter fracture are the most common long term complications of totally implantable venous catheters, early diagnosis and management of these problems can prevent severe complications.

Deep Vein as a Graft Conduit (도관으로 사용된 심부정맥)

  • Yie, Kil-Soo;Cheon, Sung-Bin;Oh, Won-Sub;Ryu, Se-Min;Lee, Bong-Ki;Kim, Hyung-Rae;Kim, Keun-Woo
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.441-446
    • /
    • 2010
  • The ideal graft requires acceptable size, less tissue toxicity, resistance to infection, and long-term durability. Great saphenous veins are gaining popularity as acceptable graft conduits, but they require time to grow in caliber. We report 2 cases of graft bypass and reconstruction using superficial femoral veins to acheive immediate high-flow patency.

Saphenous Vein Graft as a Composite Graft in Patients Who Are Undergoing Off-pump Coronary Artery Bypass: The Early Results (복재정맥 복합도관을 이용하여 시행한 심폐바이패스를 사용하지 않는 관상동맥우회술의 조기 결과)

  • Hwang, Ho-Young;Kim, Jun-Sung;Choi, Eun-Seok;Lee, Jae-Hang;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.324-330
    • /
    • 2009
  • Background: The long term patency of the free saphenous vein graft, which is the most commonly used conduit, anastomosed to the ascending aorta has been reported to be lower than that of arterial grafts. We evaluated early clinical outcome and the angiographic patency of the saphenous vein composite graft based on the left internal thoracic artery, and compared these results with those of using arterial composite grafts. Material and Method: From September 2006 to October 2008, 419 patients underwent off-pump coronary revascularization. Among those, 295 patients (70.4%) were revascularized using composite grafts (group I: saphenous vein composite graft, n=71, group II: arterial composite graft, n=224). The clinical results were compared between the 2 groups. Early postoperative coronary angiograms were performed in all the patients. ($1.6{\pm}1.6$ days) Result: The number of the distal anastomosis per patient was $3.5{\pm}1.0$ and $3.1{\pm}0.8$ in group I and II, respectively (p=.002). The operative mortality (n=2, 0.7%) and postoperative complications such as atrial fibrillation (n=73, 24.7%), perioperative myocardial infarct (n=6, 2.0%), acute renal failure (n=6, 2.0%), reoperation for bleeding (n=5, 1.7%), cerebrovascular accident (n=3, 1.0%), and mediastinitis (n=1, 0.3%) were not related with the use of saphenous vein graft. Early coronary angiograms revealed a 96.9% (126/130) for the saphenous vein grafts and a 98.8% (479/485) for the composite graft in group II (p=.231). Conclusion: Our data suggested that a saphenous vein graft might be used as analtemative conduit to the arterial graft for constructing a composite graft, as based on our early clinical and angiographic results. Further study is required to establish the long-term efficacy of using a saphenous vein as a composite graft.

Complete Fracture of Totally Implantable Venous Catheter (완전 거치형 정맥도관의 완전 절단)

  • Kim, Jung-Tae;Chang, Woon-Ha;Oh, Tae-Yoon
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.946-948
    • /
    • 2006
  • The patient was a 42-year-old female with breast cancer who had an implantable central venous catheter inserted percutaneously into left subclavian vein for chemotherapy. The postinsertion chest x ray revealed that there was no compressive sigh of catheter. Three months after insertion of the catheter, the patient was admitted to the hospital for 4th chemotherapy. The port was accessed but blood could not be aspirated and the catheter could not be flushed. A chest x ray revealed that the catheter was completely transected at the point where the catheter passed under the clavicle. Percutaneous removal of the distal fragment of the catheter was accomplished. The patient was discharged after successful removal of fragment of catheter.

Epidemiology of central venous catheter related blood stream infections in pediatric patients (중심정맥 도관 관련 감염의 역학 고찰)

  • Kim, Jung Hyun;Eun, Ho Sun;Choi, Kyung Min;Kim, Dong Soo;Young, Dong Eun
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.2
    • /
    • pp.157-161
    • /
    • 2006
  • Purpose : The purpose of this study is to investigate the pathogens of central venous catheter-related blood stream infections and search for the association among the insertion site, the duration and the underlying conditions with the prevalence of central venous catheter-related blood stream infections under 15 years old. Methods : A retrospective study was performed from Jan, 2003 to Dec, 2003 in Severance Hospital on 112 patients who undertook central venous catheter insertions. Results : We examined 112 patients who undertook central venous catheter insertion. The mean age of patients was $4.77{\pm}4.12$ years old. Coagulase negative Staphylococci was the most common organism of central venous catheter-related blood stream infections accounting for 33.9 percent, followed by Eenterococcus faecium(9.3 percent), and Staphylococcus aureus(7.5 percent), The most common insertion site was the right femoral vein, followed by the right jugular vein and the left femoral vein. The mean insertion period was $14.17{\pm}12.00$ days. Conclusion : Central venous catheter-related blood stream infections were not only related to the underlying conditions, but also to the insertion site. We need to study the clinical importance of coagulase negative Staphylococci as it is part of the normal flora of the skin. In future, more studies are needed to take preventive measures and improve treatment methods.

A Study on Central Vein Cannulation Using Audible Doppler Guidance in Children and Infants (Audible Doppler Ultrasound(8 MHz)를 이용한 소아와 영아에서 중심정맥 도관 삽입술에 관한 연구)

  • Ahn, Young Joon;Jung, Jin Young;Hong, Soo-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1120-1125
    • /
    • 2002
  • Purpose : Percutaneous cannulation of the central vein in children and infants may be technically difficult and can cause serious complications. There are many techniques to improve the success rate and to decrease the complications in central vein cannulation. This study was undertaken to determine whether audible Doppler guidance can help operators improve the results of central vein cannultion in pediatric ICU. Methods : A total of 46 central vein cannulations were performed using audible Doppler guidance technique. Using an 8-MHz Doppler ultrasound device(Pocket-Dop II. iMex. USA), the artery and the vein were identified by their characteristic Doppler sounds. Results : There was a total of 46 patients with 20 boys and 26 girls, respectively. The mean age was $3years{\pm}45months$(range : 1-156 months). The number of infants was 18 and the mean age was $6.3{\pm}3.8$ months(range : 1-12 months). The most common site of central vein cannulation was the right internal jugular vein(63%). The cannulation was successful in 44 out of 46 procedures(96%). The success rate at the first attempt was 59% with 48% in the patients who had the history of previous cannulation and 70% in the patients who did not, respectively. The success rate in infants was 94%(17 out of 18). The average access time was $5.2{\pm}8.3$ minutes in children contrary to $7.5{\pm}10.3$ minutes in infants. There were no serious complications, but six patients had complications including four hematoma, one arterial puncture, and one pneumothorax. Conclusion : This central vein cannulation using Doppler guidance may improve the success rate of central vein cannulation and decrease the development of serious complications in infants and children.

Central Vein Occlusion Secondary to Hemodialysis Catheterization in Chronic Renal Failure Patient -One Case Report- (만성 신부전 환자에서 혈액투석 도관에 의한 중심정맥 폐쇄증의 수술치험 -1례 보고-)

  • Lee, Seock-Yeol;Lee, Jun-Bock;Lee, Man-Bok;Youm, Wook;Lee, Kihl-Rho
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.619-623
    • /
    • 1998
  • A 51-year-old male with chronic renal failure had marked swelling and tenderness of the right arm. Venography revealed central vein occlusion involving stenosis of right proximal subclavian vein, right internal jugular vein, and left distal innominate vein, and obstruction of right brachiocephalic vein. Multiple obstruction of these veins was thought to have resulted from repeated subclavian catheterization. Right subclavian-superior vena cava was bypassed with 10 mm Gore-tex vascular graft and then left subclavian vein with 8 mm Gore-tex vascular graft was bypassed to the 10 mm Gore-tex vascular graft. The results were excellent.

  • PDF

Umbilical venous line-related pleural and pericardial effusion causing cardiac tamponade in a premature neonate : A case report (제대정맥도관으로 인한 흉막삼출 및 심장압전을 동반한 심낭삼출 1례)

  • Hong, Eun Jeong;Lee, Kyung A;Bae, Il-Heon;Kim, Mi-Jung;Han, Heon-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.6
    • /
    • pp.686-690
    • /
    • 2006
  • Cardiac tamponade with pleural and pericardial effusion is a rare but life-threatening complication of umbilical venous catheterization in the newborn. It requires a timely diagnosis and urgent treatment, such as pericardiocentesis, to save lives of affected patients. Recently, we experienced a 7 day-old, very low birth weight infant, who developed a cardiac tamponade with pleural and pericardial effusions complicated by umbilical venous catheterization. The patient was successfully treated with pleural and pericardial drainages. Here, we report this case with a review of literature, since there has been no such previous case reported in Korea.

Morphologic Follow-Up of the Anastomotic Sites Using One-year and Five-year Angiography after Coronary Artery Bypass Grafting (관상동맥우회술 후 1년 및 5년 추적 관상동맥조영술을 이용한 문합부위의 형태학적 변화)

  • Cho Kwang Ree;Kim Jun-Sung;Choi Jae-Sung;Chae In-Ho;Oh Byung-Hee;Lee Myoung-Mook;Park Young-Bae;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.191-196
    • /
    • 2005
  • We analysed the characteristics of anastomotic sites after coronary artery bypass grafting (CABG) using coronary angiographies (CAGs) performed at one and five years postoperatively in the same patient population. Material and Method: Among the 219 patients who underwent isolated CABGs between January 1995 and December 1997, follow-up coronary angiograms were performed in 149 ($75.3\%$) patients at one year and in 115 ($58.1\%$) patients at five years postoperatively. FitzGibbon grading system was used to evaluate the anastomotic sites. Result: The patency rates of arterial grafts at one- and five-year were $96.5\%$ (192/199) and $93.1\%$ (134/144), which were higher than those of saphenous vein grafts (SVGs) ($82.9\%$ (224/270) and $77.5\%$ (141/182), respectively) (p=0.01). Although there were significant decreases in the patency rates between one- and five-year CAGs of both arterial and venous grafts, the proportion of FitzGibbon grade B among the SVGs was increased from $5.2\%$ (one-year) to $8.2\%$ (five-year), suggesting the progression of vein graft disease (p < 0.01). Conclusion: The patency rate of the arterial graft was higher than that of SVG in both one- and five-year CAGs. The attrition rate of saphenous vein graft was higher than arterial grafts.