• Title/Summary/Keyword: 정렬검사

Search Result 74, Processing Time 0.029 seconds

Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs) (다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교)

  • Gil, Jong-Won;Lee, Kwang-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.605-611
    • /
    • 2019
  • The purpose of this study is to manufacture a multi-function device (MFD) which can be applied to various types of weight-bearing view of the lower leg, and to compare the results with the images from the existing weight-bearing platforms (WBPs), thereby suggesting a clinical utilization. The MFD was manufactured, by considering the minimum adjustable heights of the platform for weight-bearing foot/ankle, platform for hindfoot alignment view, and X-ray tube of the X-ray device. A foot/ankle phantom was used to take the images of weight-bearing lateral foot in MFD and WBPs to compare the resolutions of the X-ray images using a quick modulation transfer function (MTF) program. Between both the images taken from the MFD and WBPs, there was no statistically significant difference found in the mean cycles per pixel (C/P) and the lines per image height (LPH) of the 50%-Contrast Spatial Frequency (MTF50), and 10-90% of Maximum Energy Rise Distance (10-90%), where p>0.05. The MFD is suggested for its clinical trial as a useful positioning device that can secure the patient's safety and manifoldly perform various inspections. Also, the recommendation of the positioning device as a policy can activate dedicated manufacturers, while also improving the quality of medical services.

Data Flow Analysis for Deriving Uniform Recurrence Equation from Loop Algorithms (루프 알고리즘으로부터 정규순환방정식 유도를 위한 자료흐름 분석)

  • Gu, Gyo-Min;Ha, Gyeong-Ju;Yu, Gi-Yeong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.2
    • /
    • pp.145-154
    • /
    • 1999
  • 본 논문에서는 주어진 문제의 루프 알고리즘으로부터 시스톨릭 어레이 구현이 용이한 정규 순환 방정식으로의 자동적 유도를 위한 대수적인 방법과 조건을 제시하였다. 이를 위하여 계산점 집합과 순차 정렬 벡터를 구하고, 행렬의 커널을 이용하여 자료 흐름 벡터를 찾았으며, 정규 파이프라이닝 가능성 조건을 제시하였다 그리고 각 계산점에 대한 배열 원소의 초기 입력 위치를 구하였다. 본 논문에서 제시된 방법을 사용하면 주어진 루프 알고리즘을 정규 순환방정식으로 자동적으로 유도 할 수 있으며, 주어진 알고리즘이 정규 순환 방정식으로 유도될 수 있는지를 검사할 수 있다.

Plagiarised Reports Detection System using Characteristcs of Korean Language and Local alignment Algorithm (한글 구조특성과 지역정렬 알고리즘을 사용한 표절 판정 시스템의 개발)

  • 전명재;박상돈;박웅;허진영;조환규
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.727-729
    • /
    • 2004
  • 최근 논문의 표절 및 저작권과 관련하여 여러 가지 사건들이 일어나 많은 관심과 우려를 불러일으키고 있다. 특히 인터넷 통신의 발달 및 워드프로세서의 기능 향상으로 인해 일선 교육현장에서의 표절에 간한 문제는 더욱 커지고 있다. 하지만 문서의 표절 여부를 가려내는 작업은 쉬운 일이 아니다. 과제로 제출되는 일반 문서의 경우 본문의 내용이나 문서의 개수를 고려해 볼 때 사람이 직접 표절 여부를 검사하는 것은 매우 힘든 작업이다. 그리고 어간, 어미의 변형이 쉽게 일어날 수 있는 한글의 경우에는 영어에서처럼 어절 단위로 두 문서를 비교하여 표절여부를 판정하는 기존의 방법은 적합하지가 않다 본 논문에서는 한글로 작성된 텍스트 문서의 표절 여부를 효과적으로 검출해 내기 위한 새로운 방법들을 제시하고 있다. 그리고 실제로 수집된 다양한 문서 데이터 집합들에 대해 각각의 방법들을 테스트해 보고 실제 데이터에서 가장 효율적인 방범이 어떤 깃인지 제시한다

  • PDF

GBAS Flight Testing and Performance Assessment using Flight Inspection Aircraft at Gimpo International Airport (비행검사용 항공기를 이용한 김포국제공항 GBAS 비행시험 및 성능평가)

  • Jeong, Myeong-Sook;Bae, Joongwon;Jun, Hyang-Sig;Lee, Young Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.1
    • /
    • pp.49-61
    • /
    • 2015
  • Ground Based Augmentation System(GBAS) is a system that offers an aircraft within 23 NM radius from the airport precision positioning service and precision approach service using the concept of Differential Global Positioning System(DGPS). After GBAS ground equipment installing at the airport, functionalities and performances of GBAS should be verified through the GBAS ground and flight testing. This paper describes the methods and results for GBAS flight test using the flight inspection aircraft at Gimpo International Airport. From the test results, we confirmed that the VDB data was received without misleading within the VDB coverage of Gimpo International Airport, and VDB field strength, protection level, and course alignment accuracy met the evaluation's criteria.

Aircraft Deformation Measurement using Industrial Photogrammetry (산업사진측량기법을 이용한 항공기 변형 측정)

  • Lee Jae-Kee;Jung Sung-Heuk;Yu Jung-Hum
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.2
    • /
    • pp.205-210
    • /
    • 2005
  • As industries developed, industrial goods have got more precise. It led producers to feel like having a way to confirm whether the goods are good enough for the needs of consumers or not. Because of that, producers got interested in industrial photogrammetry that can get accurate data quickly with non-confect method. therefore, this study was examined by photographing an O-2A aircraft which was a large and precise one to check the application of Industrial photogrammetry. To measure the aircraft, the check points, that was attached to it was used as it was not possible to measure the aircraft by its design. The experiment was carried out in three parts considering arrangement of the check points and measured with Pro-spot to check any deformation of its external form. As a result, this study enables us to conferm a state of the aircraft alignment promptly and to provide accurate data for producers, which helps them to make a decision.

Observation of Dynamic Movement of Probing Pin on PCB Pad Using Electrical Reliability Test (인쇄회로 기판의 전기검사에서의 미세 탐침과 패드의 동적 거동 현상 관측)

  • Song, Seongmin;Cha, Gangil;Kim, Myungkyu;Jeon, Seungho;Yu, SangSeok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.245-251
    • /
    • 2015
  • In an electrical reliability test of a printed circuit board (PCB), the impact of the micro probing pins on the PCB needs to be checked to ascertain the quality of the circuit. In this study, the impact of the dynamic movement of the probing pin on the pad was observed. As a misaligned pin can exert horizontal force on the pad of the PCB, this study focused on the behavior of a misaligned probing pin. The parameters of observation were the circular and flat edges of the probing pin. The effects of the speed of movement, diameter, and the length of projection of the probing pin were also investigated. The results demonstrated that slippage angle is strongly affected by the shape of the edge of the probing pin, and that projection length is an important factor affecting pin slippage. In contrast, the speed of movement of the probing pin was able to double the slippage angle.

The Efficacy of Conjugated Linoleic Acid and Carprofen in Progression of Early Stage of Experimentally Induced Osteoarthritis in Dogs (개에서 Conjugated Linoleic Acid와 Carprofen이 실험적 골관절염 초기 진행에 미치는 효능)

  • Park, Se-il;Bae, Jae-sung;Kwon, Young-sam;Jang, Hwan-soo;Li, Wen-xue;Lim, Jae-hyun;Eom, Ki-dong;Kim, Jung-eun;Jang, Kwang-ho
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.278-285
    • /
    • 2003
  • This study was performed to compare early stage changes following the administrations of Conjugated Linoleic Acid (CLA), Carprofen and their combinations in the experimental canine cranial cruciate ligament rupture. Twenty five mongrel dogs were divided into five groups; Groups 1, 2, and 3 received a sectioning the cranial cruciate ligament (CCL) of the right stifle joint, and were administered CLA (250 mg/kg/day/orally), carprofen (4.4 mg/kg/day/orally), and their combinations for 4 weeks beginning 4 weeks postsurgery, respectively. Group 4 received sectioning CCL and no treatment. Group 5 was composed of unoperated normal dogs. The macroscopic observation of cartilage erosions on both the condyles and plateaus were evaluated, and the severity of the cartilage lesions and synovial inflammation was examined histologically at eight weeks after surgery. Histological examinations including hematoxylin and eosin stain, standard toluidine blue method, PAS technique and Masson trichrome technique, hematologic and radiographic evaluation were perfonned after experimental surgery. Slight yellowish discoloration of the surface was found in some of the experimental dogs. However macroscopic findings showed no significant differences among the groups. In radiographic findings, cranial displacement of the proximal tibia relative to the femoral condyles in all groups was observed but no significant differences among the groups was seen. This study showed that oral administration of CLA, carprofen and their combinations revealed no early stage change in the canine stifle joint following experimental rupture of the cranial cruciate ligament.

Measurement of Tensile Properties for Thin Aluminium Film by Using White Light Interferometer (백색광간섭계를 이용한 알루미늄 박막의 인장 물성 측정)

  • Kim, Sang-Kyo;Oh, Chung-Seog;Lee, Hak-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 2010
  • Thin films play an important role in many technological applications including microelectronic devices, magnetic storage media, MEMS and surface coatings. It is well known that a thin film's material properties can be very different from the corresponding bulk properties and thus there has been a strong need for the development of a reliable test method to measure the mechanical properties of a thin film. We have developed an alternative and convenient test method to overcome the limitations of previous membrane deflection experiment and uniaxial tensile test by adopting a white light interferometer having sub-nanometer out-of-plane displacement resolution. The freestanding aluminium specimens are tested to verity the effectiveness of the test method developed and get the tensile properties. The specimens are 0.5 rum wide, $1{\mu}m$ thick and fabricated through MEMS processes including sputtering. 1 to 5 specimens are fabricated on Si dies. The membrane deflection experiments are carried out by using a homemade tester consisted of a motor-driven loading tip, a load cell, and 6 DOF alignment stages. The test system is compact enough to set it up beneath a commercial white light interferometric microscope. The white light fringes are utilized to align a specimen with the tester. The Young's modulus and yield point stress of the aluminium film are 62 GPa and 247 MPa, respectively.

Evolution of Exercise Performance and Medical Assessments in U-12 Youth Football Players (U-12 유소년 축구선수의 운동수행력 및 의학적 평가)

  • Seo, Sang-Won;Lee, Ho-Seong
    • 한국체육학회지인문사회과학편
    • /
    • v.56 no.5
    • /
    • pp.665-677
    • /
    • 2017
  • This study aimed to examine the evolution of exercise performance and medical assessments in U-12 youth football players. Participants were recruited from an youth football players (YFG, n=15; $11.2{\pm}0.9yrs$) and normal youth (CON, n=15; $11.5{\pm}0.6yrs$). Both groups were tested for exercise performance (health related physical fitness, skill related physical fitness, functional movement screen; FMS and Y-balance) and medical assessments (lower extremity alignment, range of motion; ROM and manual muscle test; MMT). YFG showed a positive effects on pacer in health related physical fitness, 50-m run and Single-leg standing with eyes closed in skill related physical fitness, active straight leg raise and rotary stability in FMS, non-dominant composite score in Y-balance, respectively compared to CON. However, YFG showed a negative effects on Q-angle of dominant and non-dominant in lower extremity alignment, dorsiflexion of non-dominant, plantarflexion of dominant and non-dominan in ROM, hip extension and abduction, knee flexion and extension of dominant, knee flexion and extension of non-dominant in MMT, respectively compared to CON. These results indicated that U-12 youth football players have shown excellent exercise performance, but medical assessments has proved negative effects.

Improvement of the Uniformity of Temperature Distribution inside Semiconductor Test Equipment Chamber (반도체 검사 장비의 챔버 내부 온도 분포의 균일성 개선)

  • Lee, Kwang-Ju;Jeong, Kyung-Seok;Park, Sung-Mun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3626-3632
    • /
    • 2010
  • Some design changes were made to enhance the uniformity of temperature distribution inside the chamber of semiconductor test equipment. The design changes include the installation of adjustable airflow controller inside the chamber, the alignment of the centers of heater and match plate, the change in the size and the shape of holes in match plate base, and the addition of new holes of 2 mm diameter in order to allow airflow directly to the temperature sensors. In order to verify their effects, the temperature distributions inside the chambers were measured using 32 RTD sensors before and after the design changes. The temperature distributions were in the ranges of 87.1 to $91.5^{\circ}C$ ($90{\pm}2.9^{\circ}C$) and 89.5 to $90.8^{\circ}C$ ($90{\pm}0.8^{\circ}C$) before and after the design changes, respectively. The above temperature distribution after design changes was maintained for longer than 15 minutes, which satisfied the target temperature range of $90{\pm}1^{\circ}C$ for longer than 10 minutes.