• Title/Summary/Keyword: 정량 토출

Search Result 18, Processing Time 0.034 seconds

A Study on High Viscosity Phosphor Dispensing Process for Implementation of High-Efficiency White LED (고효율 백색 발광다이오드 구현을 위한 고점도 형광체 정량 토출 공정 연구)

  • Yang, Young-Jin;Kim, Hyung-Chan;Ko, Jeong-Beom;Yang, Bong-Su;Dang, Hyun-Woo;Doh, Yang-Hoi;Cho, Kyung-Ho;Choi, Kyung-Hyun
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.97-102
    • /
    • 2014
  • Currently various studies are underway for dispensing high-viscosity phosphor. These studies have reported limitations and challenges in the dispensing process. The discharged amount of phosphor was approximately the same each time which is important for the implementation of high-efficiency white LED technology. This paper present high-viscosity phosphor dispensing process for white LED implementation by using electrostatic printing technology. The voltage controlled DOD (Drop-On-Demand) discharge experiment was studied to determine angle of drop meniscus at nozzle and dot diameter. With increase in Discharge voltage, the discharge angle of meniscus increased while dot diameter decreased. Therefore it can be concluded that we can control the discharge rate by controling the discharge angle of meniscus.

Pump operation based on pressure sensors for the damage reduction of water distribution system (상수도관망의 피해저감을 위한 센서기반 펌프운영)

  • Kwon, Hyuk Jae;Kim, Hyeong Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.200-200
    • /
    • 2019
  • 본 연구에서는 실제 가압장 및 가압장후단부의 상수도관망에 발생가능한 수충격해석을 수행하고 신뢰성해석을 수행하여 파괴확률을 정량적으로 산정하였다. 이를 위해 가압장의 펌프운영조건을 다르게 적용하였고 관말단부의 압력센서를 이용하여 토출압을 선택적으로 운영하면 수충격의 규모도 작아지고 파괴확률도 대폭 줄어드는 것을 확인할 수 있었다. 가압장의 토출압을 선택적으로 운영하기 위해서는 관말단부에 필수적으로 충분한 수압이 존재해야하며 이를 위해서 실시간 모니터링이 가능한 압력계를 설치하게 된다. 이 압력계로부터 수신되는 데이터를 통하여 펌프의 운영이 이루어지고 최소한의 에너지 사용을 통해 효율을 증대하고 피해율도 저감하게 된다. 본 연구에서 개발된 센서기반 펌프운영시스템이 적용된 실제 상수도관망은 현재 가압장의 운영조건으로 24시간 75m의 펌프 토출압을 유지하고 있으며 관말단부의 수용가에 충분한 수압이 전달되고 있다. 가압장의 고압유지는 관말단부에 충분한 수압을 전달하기 위한 것이지만 상수도관망에서 누수와 시설물에 대한 많은 피해를 유발할 수 있다. 따라서 본 연구에서는 가압장의 펌프토출압을 75m와 60m로 선택적 운영을 할 수 있도록 프로그램을 개발하였다. 기존 가압장의 운영조건과 선택적 운영조건을 사용하여 수충격해석을 수행하였고 신뢰성해석모형을 사용하여 파괴확률을 정량적으로 산정할 수 있었다. 가압장의 운영조건을 최적화하여 효율은 증대하고 피해율을 저감할 수 있는 방법을 찾을 수 있었다. 이를 위해서 가압장의 인버터 설치는 물론이고 펌프의 최적운영을 위해 개발된 펌프운영 프로그램을 가압장 배전반에 장착하여 경제적인 운영이 될 수 있을 뿐만 아니라 실제 상수관망에서 과도한 수압으로 인해 발생할 수 있는 여러 가지 피해를 최소화할 수 있을 것으로 판단된다. 또한, 본 연구에서는 기존의 펌프장 토출압으로 운영되었을 때와 비교하여 에너지 절감율을 정량적으로 산정하여 비교분석하였다. 가압장 후단의 작은 마을을 대상으로 하여 절감된 전기요금은 적은 양이라 할 수 있겠으나 개발된 시스템을 전국에 적용한다면 에너지 절감으로 인한 경제적 파급효과는 크다고 할 수 있다.

  • PDF

Four-Parameter Study on the Jet Regurgitnant Mode of Resonant Tube (공진 관의 토출 모드에 대한 네 가지 매개 변수 연구)

  • Chang Se-Myong;Lee Soogab
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.255-258
    • /
    • 2000
  • 초음속 유동장 내에 설치된 끝이 막힌 관에 의해 발생하는 공진 현상에는 스크리치 모드 (jet screech mode)와 토출 모드 (jet regurgitant mode)가 있다 이중 토출 모드는 원리상 음향학적 공진과 밀접한 관련이 있다. 본 연구에서는 경계 조건으로, 주어진 강도와 주파수를 갖는 마하 수의 진동을 통하여 압축성 유동장을 가진하는 개념적 모델을 통하여 공진 현상을 모사한다. 비선형 효과의 탐구를 위해 축대칭 오일러 방정식을 수치적으로 풀이하면서, 4 가지의 주요한 파라메터들 (가진 강도, 가진 주파수, 진 동부와 관 사이의 거리, 관의 깊이)을 추출하고 이에 대한 영향을 연구하였다. 또한 비선형 유동 효과에 의해 발생하는, 고전 이론에 의해 예측된 공진 주파수와의 차이를 정량적으로 나타내고 그 원인을 고찰하였다.

  • PDF

Quantitative Evaluation of Forest Fire Suppression Equipments as the Extinguishing Distance (진화거리에 따른 산불 진화 장비의 정량화 평가)

  • Kim, Jeong-Hun;Kim, Jang-Huan;Kim, Kyong-Ha;Lee, Byung-Doo;Shin, Jae-Youn
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.426-429
    • /
    • 2011
  • 산불 발생 시 진화를 위해 사용되는 주력 지상 진화장비 중 동력펌프 2종과 진화 차량을 대상으로 수원지로부터 발화 지점까지 진화거리에 따른 주요 성능을 측정하였다. 성능 측정은 분당 토출량, 토출 최대압력, 수평 분사거리, 수직 분사거리의 4개 항목이었으며, 노즐의 종류에 따른 영향을 동시에 고려하였다. 산불 진화 시 적정 거리를 측정한 결과 소형펌프의 경우 600m, 중형펌프의 경우 800~1000m 정도인 것으로 나타났다. 또한 분당 토출량은 3가지 펌프 모두 50m에서 1000m로 연결할 경우 52~62% 감소가 일어나며, 최대 토출압력은 26~30% 상승되어 부하 발생시 고압호스의 파손 우려도 있는 것을 알 수 있었다. 실험을 통해 소형펌프의 경우는 주 산불진화에 적합하지 않으며, 중형펌프의 경우 고압호스의 성능에 따라서 1000m이상의 거리에서도 사용이 가능할 것으로 사료된다.

  • PDF

Development of an Automatic Nutrient-Solution Mixing and Supplying System (다구역 재배용 양액 자동 조제.공급 시스템 개발)

  • 김기영;전성필;류관희
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2000
  • In recent, multi-sector nutriculture in which each sectors are managed with different compositions and supplying amounts of nutrient solution is being prevalent especially in large-scale greenhouses. This study was carried out to develop an automatic mixing and supplying system of nutrient solution for the multi-sector greenhouse which can control various compositions of nutrient solution and supplying amounts for each sector. The stock solution control device could control discharge of the stock solution with device actuating time. The experimental result showed high correlation between the discharge and the actuating time. The system could make nutrient solution of various compositions and showed possibility of changing compositions of nutrient solution according to changes of growth stages or environments. Undesirable remnant nutrient-solution effect on the next supply was decreased by lowering RC of the previous nutrient solution remaining in the tank and supply pipe through rinse process. To evaluate performance of the developed system, experiments that compare N $O_3$$^{[-10]}$ , and P $O_4$$^{3-}$ concentrations of nutrient solution made in laboratory level with those made by the developed system were conducted. The experimental results showed that the deviations for N $O_3$$^{[-10]}$ , and P $O_4$$^{3-}$ concentrations of nutrient solution composited by the developed system were -2.36% and -5.15%, respectively.

  • PDF

Characterization of Color Change in Injection Molding Process Using Hot Runner (핫 러너 사출 공정에서 수지의 색 교체 특성 연구)

  • Hong, Ji Sun;Shim, Hee Soo;Lee, Ji-Hyun;Kwon, Min-Kyung;Chung, Dong-Il;Kim, Sun Kyoung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.1
    • /
    • pp.111-115
    • /
    • 2015
  • In injection molding process using hot runners, color change is a critical issue. This work proposes a method of assessing the color change characteristics of thermoplastics polymers. A method that utilizes a capillary die to measure degree of color change has been devised and implemented. The extrudate from the capillary die has been imaged and quantized to a gray scale value. Based on the gray scale value, the degree of color change has been determined. Under given temperatures and extrusion velocity, its trend along with the number of extrusion has been obtained and analyzed.

정박 중 준해양사고 원인에 대한 빅데이터 분석 연구

  • No, Beom-Seok;Kim, Tae-Hun;Gang, Seok-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.144-146
    • /
    • 2018
  • 준해상사고를 줄이기 위하여 준해양사고 등을 분석하여 사고 예방에 활용하였다. 하지만 준해양사고 건수가 많은 대신 주내용이 정성적이기 때문에 다양한 정량적 데이터로 분석하기에는 현실적 어려움이 있었다. 이러 장단점을 고려하여 준해양사고에 대해서 그동안 단순한 내용 검토 방식에서 통계적 분석과 이를 통한 객관적 결과 토출이 가능한 빅데이터 기법를 적용한 연구가 필요하다. 이를 위해 10,000여건의 준해양사고 보고서를 전처리 작업을 통해 통일된 양식으로 정리하였다. 이 데이터를 기반으로 1차로 텍스트마이닝 분석을 통해 정박 중 준해양사고 발생 원인에 대한 주요 키워드를 도출하였다. 주요 키워드에 대해 2차로 시계열 및 클러스터 분석을 통해 발생할 수 있는 준해양 사고 상황에 대한 경향 예측을 도출하였다. 이번 연구에서는 정성적 자료인 준해양사고 보고서를 빅데이터 기법을 활용하여 정량화된 데이터로 전환할 수 있고 이를 통해 통계적 분석이 가능함을 확인하였다. 또한 빅데이터 기법을 통해 차 후 발생할 수 있는 준해양사고 객관적인 경향을 파악함으로써 예방 대책에 대한 정보 제공이 가능함을 확인할 수 있었다.

  • PDF

A Study on Development of Shutoff Operating System of Ultra-High Pressure Positive Displacement Pump (초고압 용적형 펌프의 체절운전시스템 개발에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul;Sung, Gi-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Ultra-high pressure positive displacement pump can discharge high pressure water with mass volume, which depends on periodic changes in volume that made by rotation motor. Its high efficiency of discharge is one of the most strong point of positive displacement pump. Due to its simple system structure, it can be miniaturized and lightened. Positive displacement pump can discharge high pressure with stable flow rate, irrespective of pressure fluctuate. This is the reason that positive displacement pump was used instead of centrifugal pump. In this study, shutoff operating system was developed for positive displacement pump to secure safety of high pressure operate. This shutoff system contains controller system, electronic clutch, and relief valve, and each part is mutual supplementation. Speed test was carried out in order to check operation of controller program and electronic clutch and fluid flow, venting experiment of the relief valve. It was confirmed that segment system of ultra-high pressure positive displacement pump is operated.