• Title/Summary/Keyword: 정격

Search Result 699, Processing Time 0.022 seconds

A Study on the Speech Transmission Index Method for Estimating Articulation of Loudspeaking Telephony (음성전송지수를 이용한 확성전화기의 명료도 평가 방법)

  • Jang, Dae-Young;Kang, Seong-Hoon;Sim, Dong-Yeon;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.32-39
    • /
    • 1994
  • The speech transmission quality in telephone is quantified in terms of loudness rating, but this method has been validated only for the handset telephony. The transmission quality of loudspeaking telephony in any room must be evaluated not only with speech transmission but also with background noise, echo and reverberation since the effect of room acoustics is much stroger for loudspeaking telephoy. Therefore, it requires a better approach to specify the quality of loudspeaking telephony. By calcuating the speech transmission index (STI), a physical method for measuring the quality of speech transmission was proposed by Steeneken. In this paper, the application of a STI method for estimating articulation of loudspeaking telephony was discussed. And the STI measurement system with high speed calculation was also three rooms, having different reverberation times. The result show that the STI decreases as the reverberation time of rooms increases. It suggests that speech transmission index method can be useful evaluating articulation of a loudspeaking telephony including the sound field characteristics.

  • PDF

A Study on the Development of an Energy Saving Ballast Water Treatment Device (I) (에너지 절감형 평형수 처리장치 개발에 관한 연구 (I))

  • Park, Dae-Won;Kil, Gyung-Suk;Choi, Yong-Ki;Choi, Chul-Young;Chang, Ji-Ho;Cheon, Sang-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.880-886
    • /
    • 2010
  • In this paper, we studied the application of low pressure ultra-violet (UV) lamps for the development of an energy saving ship's ballast water treat (BWT) device. We proposed the optimal arrangement of UV lamps by analyzing the energy radiated from medium- and low-pressure UV lamps. Based on the experimental results, we manufactured a disinfection chamber which is composed of low-pressure UV lamps. The rated power and the treatment capacity of the chamber are 216 [W] and 10 [$m^3$/h], respectively. This can replace a disinfection chamber treated by two 2 [kW] medium pressure lamps. The disinfection performance, however the power consumption is about one-eighteen compare to the medium pressure UV lamp, is over 94 [%] for bacteria, 93 [%] for zooplankton, and 94 [%] for phytoplankton. Therefore, it would be possible to develop an energy saving BWT device in a low capacity below 100 [$m^3$/h].

Dynamic Behavior Analysis of Floating Offshore Wind Turbine Including Flexible Effects of Tower and Blade (타워와 블레이드의 탄성효과를 고려한 부유식 해상풍력발전기의 동적거동해석)

  • Jung, Hye-Young;Sohn, Jeong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.905-911
    • /
    • 2012
  • To establish a floating offshore wind turbine simulation model, a tension leg platform is added to an onshore wind turbine. The wind load is calculated by using meteorological administration data and a power law that defines the wind velocity according to the height from the sea surface. The wind load is applied to the blade and wind tower at a regular distance. The relative Morison equation is employed to generate the wave load. The rated rotor speed (18 rpm) is applied to the hub as a motion. The dynamic behavior of a 2-MW floating offshore wind turbine subjected to the wave excitation and wind load is analyzed. The flexible effects of the wind tower and the blade are analyzed. The flexible model of the wind tower and blade is established to examine the natural frequency of the TLP-type offshore wind turbine. To study the effect of the flexible tower and blade on the floating offshore wind turbine, we modeled the flexible tower model and flexible tower-blade model and compared it with a rigid model.

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

Effects of Joongjeo($TE_3$) Supplementation Aekmoon($TE_2$) Draining on Changes in Cerebral Blood Flow and Blood Pressure in Normal Rats (수소양삼초경(手少陽三焦經) 정격(正格)의 자경보사(自經補瀉)(중저 보(中渚 補), 액문 사(液門 瀉)) 자침(刺鍼)이 정상 흰쥐의 뇌혈류량(腦血流量) 및 혈압(血壓)에 미치는 영향(影響))

  • Kim, Hee-Jung;Ryu, Chung-Ryul;Cho, Myeong-Rae
    • Journal of Acupuncture Research
    • /
    • v.25 no.6
    • /
    • pp.1-12
    • /
    • 2008
  • Objectives : Joongjeo($TE_3$) Supplementation Aekmoon($TE_2$) Draining is a method belongs to Ohaeng-acupuncture, using directional supplementation and draining. Methods : This study was designed to investigate the effects of $TE_3$ supplementation $TE_2$ draining on changes in cerebral blood flow(rCBF) and mean arterial blood pressure(MABP) in normal rats. For these reasons, the present author investigated rCBF and MABP using laser doppler flowmeter in normal rats. In addtion, the present author also investigated action mechanisms of $TE_3$ supplementation $TE_3$ draining on changes in rCBF and MABP too. Results : In this results, $TE_3$ supplementation $TE_2$ draining elevated rCBF in time-dependent manner, but MABP levels decresed by $TE_3$ supplementation $TE_2$ draining. Pre-treatment with indomethacin (IDM), an inhibitor of cyclooxygenase, inhibited increase of rCBF effectively. But pre-treatment with methylene blue(MTB), an inhibitor of guanylate cyclase, decreased rCBF levels. In addition, pre-treatment with IDM also decreased MABP levels, but pre-treatement with MTB increased MABP levels. Conclusions : In conclusion, these results suggest that $TE_3$ supplementation $TE_2$ draining is effective to treat patient with disease related to cerebral ischemia, because $TE_3$ supplementation $TE_2$ draining can increase rCBF. In addition, the mechanisms are thought to be related to guanylate cyclase pathways.

  • PDF

Development of a voltage-controlled output current source for zenor diode degradation analysis (제너다이오드의 열화평가를 위한 전압제어 출력 전류원 개발)

  • Kim, Jong-ho;Chang, Hong-ki;Kwon, Young-mok;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.5
    • /
    • pp.501-507
    • /
    • 2017
  • When zenor diode load current is necessary to be controlled by input voltage as a circuit load, existing voltage controlling method cannot be applied to it because the output current of zenor diode is changed due to breakdown voltage variations. We propose input voltage controlled output current source regardless of zenor breakdown voltage variation due to degradation resulted from severe current applied electronic component life test as a circuit load in this paper. We show breakdown voltage characteristics of this zenor diode circuit through simulation, applying adequate values for each component in order to verify the circuit composed of that method, and then show the result in which output current is controlled by input voltage. We confirmed the output current varies proportional to input voltage, and developed circuit shows a constant value independent of zenor diode breakdown voltage variations due to component degradations.

An Experimental Study on Wake Flow-Field of NREL 5 MW Wind Turbine Model (NREL 5 MW 풍력터빈 모형의 후류 유동장에 대한 실험적 연구)

  • Kang, Seung-Hee;Ryu, Ki-Wahn
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.2
    • /
    • pp.85-91
    • /
    • 2017
  • A wind tunnel test for 1/86 scaled down model of the NREL 5 MW offshore wind turbine was conducted to investigate the wake and flow fields. Deficit of flow speed in the wake region and variations of the turbulence intensity were measured using a hot wire anemometer at rated tip speed ratio of 11.4 m/s and a rotational speed of 1,045 rpm. According to the test results, velocity deficits along both of lateral and vertical directions were recovered within 2 rotor radii downstream from the rotating disc plane. The tip vortices effect was negligible after 5 rotor radii downstream from the rotating plane. Turbulence intensities showed maximum value around the blade tip, and decreased rapidly after one radius apart from the rotating plane, and those values were preserved until 6 rotor radii downstream.

Numerical Simulation for Behavior of Tidal Elevation and Tidal Currents in the South Sea (남해안의 조위 및 조류거동 수치모의)

  • Kwon, Seok-Jae;Kang, Tae-Soon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.3
    • /
    • pp.253-265
    • /
    • 2007
  • This study applied the previous results of the NAO model, a tidal correction model, to the open boundary condition for the behavior of tidal elevation and tidal currents in the South Sea. This study used the EFDC model considering the wetting and drying problem and using the $\sigma-coordinate$ as a vertical coordinate and generated two mesh cases of the constant grid size of 2.0 km and the variable grid size of $0.5\sim2.0km$. The numerical results for the tides showed that the predicted results were in quite good agreements with the observational data acquired from the tidal stations of the NORI. The predicted tides were observed to propagate from the east area to the west area in the South Sea. The verification results reveal that the numerical results are more correlated with the measured tidal data as the grid size decreases. The grid size of 2 km results in proper simulation of tidal currents in wide waterway and offshore area whereas the numerical results from the grid size of 0.5 km tend to somewhat underestimate the tidal currents affected by narrow waterway and topography in inner-bay.

Development of the Furling Control Type Small Wind Turbine System (과풍속 출력 제한형 소형 풍력 발전장치 개발)

  • Choi, Young-Chul;Kim, Chul-Ho;Lee, Hyun-Chae;Seo, Young-Taek;Han, Young-Oun;Song, Jung-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.693-701
    • /
    • 2012
  • In this study, a small wind turbine airfoil specialized for national wind condition was designed in order to develop the furling control type HAWT. And then a flow analysis was carried out based on the blade drawing which was designed to characterize of the developed airfoil. The result of the flow analysis showed that the torque on the 3 blades was 180.23N.m. This is equivalent to an output power of 5.66kw and an output efficiency of 0.44. Then we produced and constructed a 3kW - furling control type HAWT by getting the system unit design technology such as the specialized furling control device. By operating this turbine, we could get 3kW of the rated power at a wind speed of 10.5m/s through the ability test. Cut-in wind speed was 2m/s, generator efficiency was 92% at the rated power output. Sound power level was 87.2dB(A). Also we observed that the output power was limited to 10.5m/s with furling system operation.

Study on Turbopump-Gas Generator Open-Loop Coupled Test (터보펌프-가스발생기 개회로 연계시험 연구)

  • Kim, Seung-Han;Nam, Chang-Ho;Kim, Cheul-Woong;Moon, Yoon-Wan;Seol, Woo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.563-568
    • /
    • 2010
  • Turbopump-gas generator open-loop coupled tests are performed during the development of a 30tonf-LOx/Kerosene rocket engine. In the turbopump-gas generator open-loop tests, the propellants to gas generator are supplied from the outlets of turbopump, while the gas exhausted from the gas generator is vented out to the atmosphere, instead of being used to turbine driving. This paper presents the objectives, procedure, and results of the open-loop coupled test, in addition to a schematic representation of the test apparatus and the operating conditions for the test facility system and control system. The results of turbopump-gas generator open-loop coupled test confirm chill-down procedure, startup characteristics, nominal operability and smooth shutdown of the open-loop coupled Test Plant in test conditions simulating engine system operation environment.