• Title/Summary/Keyword: 정격

Search Result 699, Processing Time 0.026 seconds

Modeling for Power Supply Substation in Maglev Train System (자기부상열차 급전변전소의 모델링)

  • Lee, Yun-Seong;Kim, Jin-O;Kim, Hyung-Chul;Kim, Ju-Rak;Lee, Jun-Kyung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.3
    • /
    • pp.278-282
    • /
    • 2010
  • Since a power supply substation of the magnetic levitation train system includes a inverter which is necessary to change the frequency of power, it has a different characteristic comparing to any other railway system. Nowaday a study for determining rating of facilities constituting a power supply system and modeling that system is undergoing. In this paper, a analysis model for the power supply system of the magnetic levitation train using the 3-level inverter is proposed. And the analysis for output characteristic is performed using the PSCAD/EMTDC program. The control method about the output of 3-level inverter for supplying power to loads in magnetic levitation train system is also described.

Determination of Surge Tank Scale for Dam Safety Management (댐 안전관리를 위한 조압수조의 규모 결정)

  • Lee, Ho Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.164-174
    • /
    • 2007
  • Phenomena of hydraulic transient such as water hammer should be analyzed to design the pipeline systems effectively in dam. Surge tanks generally are used to reduce change in pressure caused by hydraulic transient from load changes on the turbines. In this study, the appropriate scale of surge tank with chamber is investigated for dam safety management. The variation of water level in the surge tank are computed using governing equation. Using the Thoma-Jaeger's stability condition, static and dynamic stability are investigate for the cases of flood water level, normal high water level, rated water level and low water level. Finally appropriate diameters of shaft and chamber are determined in the surge tank with chamber.

IPMSM Drives Using NPC 3-Level Inverters for the Next Generation High Speed Railway System (NPC 3-레벨 인버터를 적용한 차세대 고속전철 IPMSM의 구동)

  • Kwon, Soon-Hwan;Jin, Kang-Hwan;Kim, Sung-Je;Lee, Tae-Houng;Kim, Yoon-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.2
    • /
    • pp.129-134
    • /
    • 2012
  • In this paper, speed control of IPMSM drives for the next generation domestic high speed railway system using NPC 3-level inverters is presented. The NPC multilevel inverter is suitable for the high-voltage and high-power motor drive system because it has advantages in that the voltage rating of the power semiconductor devices and output current harmonics are reduced. For the speed control of IPMSM using NPC 3-level inverters, maximum torque control is applied in the constant torque region, and filed weakening control is applied in the constant power region. Simulation programs based on MATLAB/Simulink are developed. Finally the designed system is verified and their characteristics are analyzed by the simulation results.

A Literature Study on the Application of Spleen Tonifying Sa-Am Acupuncture in the Diagnosis of Cold-Heat & Deficiency-Excess (한열허실변증(寒熱虛實辨證)을 이용한 비정격(脾正格) 적응증 고찰)

  • Choi, Joon-Soo;Yim, Yun-Kyoung
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.31-37
    • /
    • 2006
  • Objectives & Methods : We investigated the cases for which spleen tonifying Sa-Am acupuncture was applied in ${\ulcorner}$Sa-Am-chim-gu-jeong-jeon(舍巖鍼灸正傳)${\lrcorner}$ and classified them according to the concepts of cold-heat & deficiency-excess for a better understanding of the application of spleen tonifying Sa-Am acupuncture. Results : 1. Tonification of Spleen Sa-Am acupuncture can be used to treat heat syndromes such as deficient fire caused by collapse of the spleen qi, stagnation of evil qi or spleen yin deficiency, by way of tonifying spleen qi, activating the flow of qi and blood or harmonizing spleen yin and yang. 2. Tonification of Spleen Sa-Am acupuncture can be used to treat cold syndromes such as weakness of spleen yang by way of promoting fire to generate earth, strengthening spleen yang and raising the clear yang. 3. Tonification of Spleen Sa-Am acupuncture can be used to treat deficiency syndromes such as malnutrition or poor appetite caused by spleen deficiency by way of tonifying spleen qi. 4. Tonification of Spleen Sa-Am acupuncture can be used to treat excess syndromes such as stagnation of qi and blood, abdominal mass or toxication by way of tonifying spleen qi and promoting the flow of qi and blood.

  • PDF

Maximum Torque Control of SynRM Drive with AIPI (AIPI에 의한 SynRM 드라이브의 최대토크 제어)

  • Ko, Jae-Sub;Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.16-28
    • /
    • 2010
  • This paper proposes maximum torque control of SynRM drive using artificial intelligent(AI)PI and artificial neural network(ANN). The control method is applicable over the entire speed range and considered the limits of the inverter's current and voltage rated value. For each control mode, a condition that determines the optimal axis current for maximum torque operation is derived. The proposed control algorithm is applied to SynRM drive system controlled AIPI and ANN controller and the operating characteristics controlled by maximum torque control are examined in detail.

Operation Characteristic of Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 동작 특성)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.561-568
    • /
    • 2011
  • This paper describes the operation characteristic of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS. A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of operation characteristic and controller design has not been known after the converter circuit was proposed. For the performance evaluation of PFC converter, single-phase 3kVA double-conversion UPS was tested. The performance of PFC converter is experimentally confirmed with followings - input current reference traking, input power factor correction.

PSIM Simulator for Analysis of Series HEV Operation (직렬형 HEV 운전 특성 분석을 위한 PSIM 시뮬레이터)

  • Lim, Deok-Young;Im, Jae-Kwan;Choi, Jae-Ho;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.487-497
    • /
    • 2010
  • This paper describes the PSIM simulator for the analysis of the series type HEV operation. The traction force of the series type HEV of which engine is electrically coupled with a traction motor is supplied from the traction motor only. The rating of each power train components, such as gear, motor, ESS, ICE/generator, is designed with the Energy-Based Modeling method and the Electrical Peaking Hybrid(ELPH) method. Under driving cycle, the designed series HEV is evaluated with the developed PSIM simulator. A comparison between the conventional braking and the regenerative braking is performed with the average motor input power. And the fuel economy analysis is carried out on the basis of the simulation results.

Capacitor Charger for Solid-state Marx modulator (Solid-state Marx modulator용 커패시터 충전기)

  • Kim, Shin;Bae, Jungsoo;Kim, Hyoung-Suk;Yu, Chan hun;Jang, Sung Roc
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.24-26
    • /
    • 2018
  • 본 논문은 Solid-state Marx modulator(SSMM)용 10kV, 1kW급 고전압 커패시터 충전기의 설계에 대해 기술한다. 직렬 공진형 인버터를 기반으로 Marx modulator용 충전기 구현을 위해 다수의 커패시터를 동시에 충전할 수 있도록 다단 변압기와 정류기를 사용하는 구조를 제안한다. 변압기 1차 권선으로 단일 턴의 고전압 케이블을 사용하여 설계하고, 작은 누설 인덕턴스만으로 공진 인덕터를 구현하기 위해 DCM(Discontinuous Conduction Mode)를 기반으로 공진 파라메터를 설계한다. 6개의 환형 코어에 각각 2개의 2차 권선을 권취하고 각 2차 권선은 배전압 정류회로와 연결되어 총 24개의 커패시터를 각각 417V로 동시에 충전할 수 있도록 설계한다. 본 논문에서는 DCM영역에서 동작하는 직렬공진형 컨버터의 공진 파라메터 상세 설계에 대하여 기술하고, 24개의 커패시터 직렬 결선을 통한 10kV, 1kW 정격운전 시뮬레이션 및 실험결과를 통해 제안된 회로를 검증한다.

  • PDF

Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback (정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증)

  • Jo, Jongmin;An, Hyunsung;Park, Jiho;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.141-143
    • /
    • 2018
  • 본 논문은 계통연계형 인버터의 단독운전 방지를 위해 정궤환을 이용한 무효전력 변동기법을 제안하였으며, 구현 및 실험을 통해 단독운전 방지 성능을 검증하였다. PCC 지점에는 양호도($Q_f$) 2.5의 특성을 갖는 3상 RLC 부하가 연결되며, 부하 공진주파수는 60Hz로 설정하였다. 무효전력 변동기법은 일정 크기로 주입되는 무효분과 주파수 편차를 이용한 정궤환으로부터 공급되는 무효분으로 구성된다. 계통연계 운전 시에는 일정한 무효전력 성분만이 공급되며 역률은 0.9975이다. 단독운전 발생 시, 일정 무효전력 때문에 변화된 PCC 주파수와 계통 정격주파수 간의 편차는 정궤환 성분을 활성화하고, 증가된 무효전력에 의한 PCC 주파수 변화를 검출하여 단독운전을 판단한다. 1.7kW 3레벨 T-타입 인버터를 통해 단독운전 방지 성능을 실험하였으며, 검출시간은 각각 53ms, 150ms로써 우수한 성능을 검증하였다.

  • PDF

Non-Isolated Soft-switching Converter using transformer resonant-inductor voltage limits (변압기의 공진인덕터 전압 제한을 이용한 비절연형 소프트 스위칭 컨버터)

  • Kim, Seung Joo;Yoo, Kwang Min;Shin, Chul Jun;Kwon, Sun Man;Lee, Byung Kwon;Park, Jeong Kurn;Kim, Dong Rak;Lee, Jun Young
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.303-304
    • /
    • 2013
  • 기술이 발전함에 따라 전력변환기의 소형화 고효율화가 요구되어지고, 이를 위해 고주파 스위칭 전력변환기가 필요로 하게 된다. 하지만 스위칭 주파수와 비례적으로 스위칭 손실이 증가하기 때문에 시스템의 효율이 감소한다. 이러한 문제를 해결하기 위해 DCM방식이나 공진을 이용한 ZVZCS(Zero-Voltage Zero-Currrent) 컨버터가 제안되고 있으나 소자의 정격용량이 커지는 단점을 갖는다. 또한 ZVT(Zero-Voltage Transition)를 포함한 소프트 스위칭 기법을 적용하는 다양한 컨버터가 제안되고 있으나 공진전류의 첨두에서 보조스위치가 스위칭을 하게 되어 보조스위치 스위칭 손실이 큰 단점이 있다. 본 논문에서는 변압기로 공진인덕터의 전압을 제한시켜 보조 스위치가 영전압/영전류 스위칭을 하게 함으로서 스위칭 손실을 발생시키지 않는 소프트 스위칭 구조를 제안한다.

  • PDF