• Title/Summary/Keyword: 접합부위

Search Result 238, Processing Time 0.028 seconds

Estimation of Moment Resisting Property for Pin Connection Using Shear Strength of Small Glulam Specimens (집성재 소시험편의 전단강도에 의한 핀접합부의 모멘트 저항성능 예측)

  • Hwang, Kweonhwan;Park, Joosaeng
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.58-65
    • /
    • 2008
  • Most connections for the glulam structural members consisted of connector and fastener. The mechanical behaviour of the connection can be occurred by the dowel bearing resistance and wood shear by the fastener. This study aims at the examination of the shear properties for the small specimen with lamination components and for the full-sized pin connection and the moment resisting property for the double shear full-sized pin connection using structural column and beam members. Small specimens including glue line shows greater density and shear strength by the lamination effect than other specimens. It is needed that estimations of double shear property and moment resistance for the pin connections should be adjusted in some degree. For the better and safe estimation of moment resistance strength for the column-beam pin connection, however, the shear strength of small specimens should be deducted by 10%.

Reliability evaluation of 1608 chip joint using Sn8Zn3Bi solder under thermal shock (Sn8Zn3Bi 솔더를 이용한 1608 칩 솔더링부의 열충격 신뢰성 평가)

  • Lee, Yeong-U;Kim, Gyu-Seok;Hong, Seong-Jun;Jeong, Jae-Pil;Mun, Yeong-Jun;Lee, Ji-Won;Han, Hyeon-Ju;Kim, Mi-Jin
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.225-227
    • /
    • 2005
  • Sn-8wt%Zn-3wt%Bi (이하, Sn-8Zn-3Bi) 솔더의 장기 신뢰성을 평가하기 위하여 열 충격 시험을 행하였다. 열 충격 시험은 $-40^{\circ}C$에서 $80^{\circ}C$범위에서 1000 사이클 동안 하였다. 접합 기판으로는 각각 OSP(Organic Solderability Preservative), Sn 그리고 Ni/Au 처리를 한 PCB(Printed Circuit Board) 패드를 사용하였다. 접합에 사용한 부품은 1608 Chip(Multi Layer Chip Capacitor, Chip Resistor) 으로 전극 부위에 Sn-37wt%Pb, Sn 도금하여 사용하였다. 솔더링 후 1608 Chip의 전단 강도와 솔더링부에서 미세조직 및 IMC(Inter Metallic Compound) 변화를 관찰하였다. 측정결과, Sn-8Zn-3Bi 솔더의 초기 전단 강도는 기판의 표면처리에 상관없이 약 40N 이상이었다. 그리고 열충격 시험 1000 사이클 후에는 모든 기판에서 2N 정도 약간의 강도 저하를 보였다.

  • PDF

Compressive Strength of Diagrid Node Using H-Shape Steel (H현강 Diagrid 접합부의 압축내력 단가)

  • Ju, Young-Kyu;Park, Soon-Jeon;Kim, Kyoung-Hwan;Chang, In-Hwa;Kim, Sang-Dae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.3
    • /
    • pp.91-99
    • /
    • 2008
  • As number of the buildings increases, it shows new trends such as twisted, tilted, taperer shape. As a structural solution for the new trend buildings, diagonal grid (Diagrid) structure was developed. Though a few buildings was built using diagird system, the structural performance of the corresponding node was not clearly identified. Therefore, experimental evaluation is needed to apply diagrid for higher buildings. In this study, the node was tested depending on the amounts of welding materials. As a result, the partial welding can provide enough strength for the node as required in the full penetration welding under monotonin compressive loadings.

  • PDF

A Study on the Prediction of Laser Spot Weld Shapes of Thin Stainless Steel Sheet (스테인레스 박강판의 레이저 점용접부 형상예측에 관한 연구)

  • Kang, H.S.;Hong, S.J.;Jun, T.O.;Jang, W.S.;Na, S.J.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.8
    • /
    • pp.102-108
    • /
    • 1998
  • 본 논문에서는 Nd-YAG 레이저 용접 프로세스를 이용하여 두께가 다른 STS304스테인레스 박강판을 대상으로한 점용접에 관한 연구로서, 레이저 용접은 미소부위에 효율적인 접합가공이 가능한 공정으로 비접촉식 가열원을 이용하기 때문에 접합공정 중 기계적 변형이 없고, 레이저 빔을 국부가열원으로 하여 매우 좁은 부분에 제한적으로 열을 가할 수 있어서 강한 금속적 결합이 요구되는 소형부품의 접합에 이용될 수 있다. 뿐만 아니라 공정 변수들을 변화시켜 실제 접합부에 들어 가는 입열량을 쉽게 제어할 수 있다는 등 많은 장점을 가지고 있다. 본 연구에서는 1mm이하의 스테인레스 박판에 대한 레이저 점용접을 FDM과 신경회로망을 이용하여 해석하고 용접부의 너겟 크기, 용접부 깊이 등의 형상을 예측하였다. 또한 레이저 점용접에 있어서의 주요 변수인 펄스 에너지, 펄스 타임, 박판의 두께, 두 판사이의 간극크기 등득 변화시켜 실험하고 수치해석을 검증하기 위하여 여러 가지 강에 대한 레이저 점용접 실험을 수행하였다. 또한 수치해석 시뮬레이션을 위하여 윈도우 프로그래밍을 개발하였다.

  • PDF

Analysis of CFT Beam-to-Column Connections with T-Stiffeners (T형 스티프너를 이용한 콘크리트 충전강관 기둥-보 접합부의 해석에 관한 연구)

  • Shin, Kyung Jae;Kim, Hyun Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.375-384
    • /
    • 2005
  • The goal of this paper is to understand the stress-transfer mechanism of concrete-filled tubular column to H-beam connections with external T-stiffener through the finite element method and to offer basic data for the design of T-stiffener. To identify the problems of previous test results, the same shapes of the full-scale test specimens were modeled for the finite element analysis. Results of the analysis were compared with the test results. Several stress and strain indices were used to understand the stress-transfer mechanism of connection with various T-stiffeners parameters. The models of analysis with different T-stiffener are grouped into TS, TSD, and TSH series. An alternative plan that decreases the stress concentration of beam flange to horizontal stiffener connection is proposed through the elasto-plastic finite element method. The basic design idea and minimum sizes of T-stiffener were proposed based on the various indices in relation to the connection details.

Pile-cap Connection Behavior Dependent on the Connecting Method between PHC pile and Footing (PHC말뚝과 확대기초 연결방법에 따른 접합부 거동)

  • Bang, Jin-Wook;Oh, Sang-Jin;Lee, Seung-Soo;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.25-32
    • /
    • 2016
  • The pile-cap connection part which transfers foundation loads through pile body is critical element regarding flexural and shear force because the change of area, stress, and stiffness occurs in the this region suddenly. The purpose of this study is to investigate the structural behavior of pile-cap connection dependent on fabrication methods using conventional PHC pile and composite PHC pile. A series of test under cyclic lateral load was performed and the connection behavior was discussed. From the test results, it was found that the initial rotational stiffness of pile-cap connection was affected by the length of pile-head inserted in footing and the location of longitudinal reinforcing bars. The types of pile and location of longitudinal reinforcing bars governed the behavior of pile-cap connection regarding load-carrying capacity, ductility, and energy dissipation.

Availability of Bone Scan in Chest Trauma Patients (흉곽부위 골절에 대한 골스캔의 유용성 고찰)

    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1085-1088
    • /
    • 1998
  • Background: In trauma patients, bony thorax are exposured to the trauma in many cases. With simple x-ray, we can not detect all definitive bony abnormalities, especially in less severe cases. Bone scan is very sensitive diagnostic method in such cases. Materials and methods: We experienced 680 cases and results were as follows. Results: 1. Diagnostic sensitivity was 97.4% and false negative rate was 2.6%. 2. In sensitivity study, the time factor(when we perform bone scan) was the most important thing according to trauma pattern. In rib fracture, sensitive test time was after 1 week. In sternal fracture, sensitive test time was after 1 week, too. In costochondral junction fracture and combined cases, it was after 3 days. Conclusions: We recommend timely using of bone scan as definitive diagnostic method in bony thorax trauma patients.

  • PDF

Girth Welding Procedure and Mechanical Properties of Gas Pipeline (가스배관 원주자동용접 공정 개발 및 기계적 특성 평가)

  • Kim, Woo-Sik;Kim, Young-Pyo;Kim, Choel-Man
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.84-84
    • /
    • 2009
  • 파이프라인을 건설함에 있어 가장 중요한 기술이 배관 용접기술이다. 즉 파이프와 파이프를 연결하는 작업이 공사 진척도를 결정하기 때문에, 이를 얼마나 경제적으로 신속하게 수행해 나가느냐하는 것은 건설기간 및 건설비용을 결정하는 핵심 요소이다. 가스배관 시공 원주용접 방법은 여러 가지 있는데, 현재 국내에서는 전량 수동용접을 채택하고 있다. 이 방법은 국내 가스배관을 건설한 초기부터 적용해온 것으로 우수한 품질을 확보할 수 있으며, 취약한 국내 자동화기술과 열악한 도로 매설 시공여건에서 적용하기 용이한 방안이다. 그러나 우수한 용접기량을 보유한 용접사가 점차 부족해지고, 배관시공 시간을 단축하고 비용을 줄이기 위한 필요성이 점차 커지면서 이를 해결할 수 있는 기술로서 자동원주용접방안이 있다. 이 기술들은 해외 가스배관에 이미 오래전부터 적용되어 용접부위 신뢰성과 품질 우수성을 확보하고 시공비용절감을 달성하고 있다. 자동용접을 적용하기 위해서는 용접절차를 수립하여 절차인증시험을 수행하고, 기존방안과 동일이상의 품질이 확보되며 효율성을 겸비해야만 한다. 국가 기본에너지의 안정적인 공급을 위해 적기 시공이 필요하고, 1 km당 10 억원 이상이 소요되는 배관시공비용 중 약 1/3이 용접비파괴검사 비용인 점을 감안할 때 품질이 확보되면서 경제적인 시공방안이 있다면 이를 적용하는 것이 국가 산업 경제적 측면에서 필요한 일이다. 이와 관련된 연구에서는 국내 가스배관 원주용접에 적용 가능한 용접공정을 검토하고, 용접절차를 수립하여 절차인증시험을 수행하였으며, 추가로 배관 원주 자동용접부위에 대한 기계적 특성 평가를 실시하였다. 현재 국내 건설여건과 비파괴검사 기준을 만족시키고 안전성과 효율성을 겸비한 방법으로는 초층과 2층은 수동 GTAW를 적용하고 나머지 층은 반자동 FCAW를 적용하는 방안이 적절한 것으로 판단된다. 전 층을 자동 GTAW로 용접하는 방안은 품질은 확보되지만 효율성측면에서 대형배관에는 적용하기 어려울 것으로 보이며, 해외에서 많이 사용되는 자동 GMAW 방안은 국내 비파괴검사기준을 만족시키기 어려워 검토대상에서 제외하였다. 본 논문에서는 두 가지 용접방법에 대한 용접공정개발과정과 원주용접부위 기계적 특성을 검토하여 최적방안을 제시하고자 한다.

  • PDF

The Effect of Finger Joint Location on Bending Strength Properties (핑거접합부의 위치가 휨강도성능에 미치는 영향)

  • Won, Kyung-Rok;Hong, Nam-Euy;Ryu, Hyun-Soo;Park, Han-Min;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.318-326
    • /
    • 2013
  • The effect of finger joint location and distance from joint to joint one another on 3 point mid-concentration bending strength properties was investigated in this experiment. Resorcinol-phenol formaldehyde (RPF) and aqueous vinyl urethane (AVU) was used to domestic Pinus densiflora Sieb. et Zucc and imported Picea sitchensis Carr. that have been cut to different width of 0.15 mm between finger tip and root width and the distance from loading point to finger joint was 0, 30, 40, 50, 60 mm. The effect was not found on the location and distance of finger joint for bending modulus of elasticity, while the efficiency of bending strength property increased proportionally as the location of finger joint from the load point and the distance between finger joint increased. No influence was shown by finger joint location and distance beyond 3 times of specimen thickness, since similar values were shown between the solid wood and no destruction occurred materials.

Reliability evaluation of 1608 chip joint using Sn8Zn3Bi solder under high temperature and high humidity (Sn8Zn3Bi 솔더를 이용한 1608 칩 솔더링부의 고온고습 신뢰성 평가)

  • Kim, Gyu-Seok;Lee, Yeong-U;Hong, Seong-Jun;Jeong, Jae-Pil;Mun, Yeong-Jun;Lee, Ji-Won;Han, Hyeon-Ju;Kim, Mi-Jin
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.228-230
    • /
    • 2005
  • Sn-8wt%Zn-3wt%Bi (이하, Sn-8Zn-3Bi) 솔더의 장기 신뢰성을 평가하기 위하여 고용고습시험을 행하였다. 고온 고습 시험은 $85^{\circ}C$/85RH 조건에서 1000 시간 동안 하였다. 접합 기판으로는 각각 OSP (Organic Solderability Preservative), Sn 그리고 Ni/Au 처리를 한 PCB(Printed Circuit Board) 패드를 사용하였다. 접합에 사용한 부품은 1608Chip 으로 MLCC(Multi Layer Ceramic Capacitor 이하, 1608C) 와 Chip Resister(이하, 1608R)을 사용하였으며, 이 두 부품의 전극부위에 Sn-10wt%Pb(이하 Sn-l0PB), Sn을 각각 도금하였다. 솔더링 후 1608C 와 1608R의 전단 접합 강도와 솔더링부에서 Zn상의 변화를 관찰하였다. 측정결과, Sn-8Zn-3Bi 솔더의 초기 전단 접합 강도는 기판의 표면처리에 상관없이 약 40N 이었다. 그러나 고온 고습 시험 1000 시간 후에는 기판의 표면처리에 상관없이 약 30N 까지 감소하였다. 하지만 이는 reference인 Sn-37Pb 솔더의 강도값과 거의 유사하며, 이는 Sn-8Bi-3Zn 솔더의 고온 고습 시험 후 전단강도 특성은 기존 유연솔더와 비교하여 동등이상이라고 평가할 수 있다.

  • PDF