• Title/Summary/Keyword: 접합방식

Search Result 324, Processing Time 0.025 seconds

A Study on Verification Tests according to Connection Design Methods of Steel Plate Concrete Structures (강판 콘크리트 구조 접합부의 설계방식에 따른 검증실험 연구)

  • Hwang, Kyeong Min;Lee, Kyung Jin;Yang, Hyun Jung;Kim, Won Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • In this study, out-of-plane flexural test was performed to analyze behavior properties for a beam specimen which imitated a structure with connection member between reinforced concrete and steel plate concrete part. Tie bars between a upper and a lower steel plate, and tie wide flange shapes between upper and lower ribs were designed to prevent the steel plate or the ribs from breakaway in the connection of the specimen. As a result of the test, ductile failure behavior of the specimen and the functionality of the tie members were conformed as originally intended. Also, tension tests were performed to evaluate the design appropriateness of two specimens produced to anchor and connect mechanically #14 bars. The two test results showed that the anchorage connection system behaves in elastic limit during the main bars yielded, and the integrity of the designed system was verified.

Performance Evaluation of the Stair Joints Constructed with Partial Precast Concrete System (프리캐스트 콘크리트 계단 접합부의 접합방식에 따른 성능평가)

  • Chang, Kug-Kwan;Lee, Eun-Jin;Jin, Byung-Chang
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.833-840
    • /
    • 2008
  • The time and cost can be reduced when applying partial precast concrete to the stair system in comparison to the cast-in-place or precast method. Because the performance of staircase which is used for evacuation can be largely different from connection types of precast concrete member, we tried to know structural behavior and performance evaluation according to each type of stair joints by experimental study. In the cast-in-place rigid joint, much reinforcement is needed in the end portion because much stress is concentrated in the middle portion. Also, in the pin joint which is used in the connection point, the maximum stress occurs in the middle point, so not only the amount of re-bar is increased but also the serviceability is largely decreased. The bolt type of semi-rigid joints proposed in this study had been increased strength and serviceability which is similar to the rigid joints. Also, its ductility was shown about 0.7 times in comparison to the rigid type and was about 2.8 times for the pin joint type. According to the classification of joint in Eurocode, it can be considered that it is one of the semi-rigid joints which are in the semi-rigid-full strength, and the structural behavior can be expected by using a model which applied to stiffness value decreased by 40 percent.

Rapid Theraml Annealing Effect on the Magnetic Tunnel Junction with MgO Tunnel Barrier (MgO 절연막을 갖는 자기 터널 접합구조에서의 급속 열처리 효과)

  • Min, Kiljoon;Lee, Kyungil;Kim, Taewan;Jang, Joonyeon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.47-51
    • /
    • 2015
  • To achieve a high tunneling magneto resistance (TMR) of sputtered magnetic tunnel junctions (MTJs) with an MgO barrier, the annealing process is indispensable. The structural and compositional changes as consequences of the annealing greatly affect the spin-dependent transport properties of MTJs. Higher TMR could be obtained for MTJs annealed at higher annealing temperature. The diffusion of Ru, Mn and/or Ta in the MTJs may occur during annealing process, which is known to be detrimental to spin-dependent tunneling effect. The rapid thermal annealing (RTA) process was used for annealing the MTJs with synthetic antiferromagnets. To suppress the diffusion of Mn, Ru and/or Ta in the MTJs, the process time and temperature of RTA were minutely controlled.

Ion implatation technology for fabrication of high efficiency crystalline silicon solar cells

  • Jeon, Min-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.81.1-81.1
    • /
    • 2015
  • 최근 실리콘(Si) 원재료 가격의 하락으로 인하여, 태양광 시장에서 성능 좋은 저가의 태양광 모듈을 요구하고 있다. 즉, 와트(W)당 낮은 가격의 태양광 모듈을 선호하기 때문에 경쟁력을 갖추기 위하여서는 많은 출력을 낼 수 있는 고효율의 태양전지가 요구된다. 그래서 주목을 받고 있는 것이 N-type 실리콘 기판을 사용한 고효율 태양전지이다. 하지만, n-type Si 기판의 경우, pn 접합의 형성을 위하여서 기존의 열 확산(Thermal diffusion)법에 의한 에미터(Emitter) 형성방법은 양질의 pn접합을 형성하기에는 한계가 있다. 그로 인하여 주목하고 있는 기술이 반도체 공정에서 널리 사용되고 있는 이온 주입(Ion implantation)방식이다. 이 기술은 양질의 에미터 형성을 위하여, 동일한 양의 불순물(dopant) 주입, 정확한 접합 깊이 제어 등이 가능한 방법으로 고효율 태양전지 제작에 필수적이며, 가능한 기술이라고 할 수 있다. 본 발표에서는 어플라이드 머트리얼즈(Applied Materials)사가 보유하고 있는 고효율 태양전지 제작에 필수적인 이온주입방식의 기술과 양산화 가능한 관련장비 등을 소개 하고자 한다.

  • PDF

Proposal of PC Core System for Modular Housing (모듈러주택 적용을 위한 PC코어 시스템 제안)

  • Minjun, Kim
    • Land and Housing Review
    • /
    • v.14 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • Modular construction is popular as a smart building system because it can shorten the construction period. This study proposed a precast concrete (PC) core system that can further shorten modular construction time. The system was developed and its structural performance was verified through computational analysis. The proposed PC core system is a complete PC construction method using dry bonding. The results of the study indicated that the proposed PC core system has structural stability and performance suitable for modular housing.

Analysis of Junction Temperature Measurement in 20W Module for Street Lighting (20W 가로등 모듈의 접합온도 측정 분석)

  • Lee, Se-Il;Yang, Jong-Kyung;Kim, Nam-Goon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.163-163
    • /
    • 2010
  • 기존 LED의 접합온도 및 열저항은 PKG 단계에서 측정 가능 하였다. PKG에서의 접합온도 측정방식과 같은 방법으로 C사의 1W High Power LED XP2 20개를 직렬 연결하여 모듈을 구성한 20W 가로등 모듈에 대하여 접합온도를 측정 하였다. 측정결과 20W 가로등 모듈의 접합온도는 약 $61^{\circ}C$로 나타났다.

  • PDF

An Experimental Study on Steel Plate Coupling Beam (철골 플레이트 커플링 보의 실험적 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presented an structural efficiency of steel coupling beam jointed single plate shear connections with seat and top angle. Parameters for the test specimens were are seat and top angle, reinforcing of concrete, embedded length, section loss. Steel coupling beam with angle showed excellent strength, stiffness, energy dissipation capacity. The specimen with no reinforcement around the embedded steel plate showed slightly low deformation capacity because of early failure in the precast concrete walls. However, the specimen with reinforcement around the embedded steel plate showed good deformation capacity. Deformation capacity was not decrease despite short embedded length. The specimen with section loss showed excellent deformation capacity. Because shear strength of steel coupling beam was lesser than of connections. These results showed that for workability and cost efficiency, the proposed system is promising for one of steel coupling beam.

  • PDF

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

Flip Chip Bonder for Automactic Parallel Aligning of IR Sensors and Read Out Integrated Circuits (적외선 센서/ROIC 접합을 위한 자동 평행 배열 방식의 플립 칩 본더)

  • Suh, Sang-Hee;Kim, Jin-Sang;An, Se-Young
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.337-342
    • /
    • 2001
  • Infrared sensors with one or two dimensional arrays are usually bonded via indium bumps to Si CMOS read out circuits. Therefore, both sensing of infrared beams and processing of signals are performed at the focal plane. This gives us a benefit of reducing noise as well as size of infrared detectors. We have developed a way of boding indium bumps with keeping sensor and ROIC parallel to each other. The flip chip bonder developed has a very simple structure and is easy to operate. So we expect that reliability will be improved very much.

  • PDF