• Title/Summary/Keyword: 접합강도

Search Result 1,390, Processing Time 0.025 seconds

Strength Prediction of Exterior Beam-column Joint using 3D Strut-Tie Model (3차원 스트럿-타이 모델을 이용한 외측 보-기둥 접합부의 강도 예측)

  • Yun Young Mook;Kim Byung Hun;Lee Won Seok;Shin Hyo Jeong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.183-186
    • /
    • 2005
  • The Current design procedures of ACI 318-02 and CEB-FIP for the exterior beam-column joints do not provide engineers with a clear understanding of the physical behavior of the beam-column joints. In this paper, the failure strengths of the exterior beam-column joint specimens tested to failure were evaluated using the approach implementing 3-dimensional strut-tie models, design criteria of ACI 318-02, ACI-ASCE committee 352 and Park and paulay, and softened strut-tie model approach. The analysis results obtained from the 3-dimensional strut-tie models were compared with those obtained from the other approaches, and the validity of the approach implementing 3-dimensional strut-tie models were examined.

  • PDF

Statistical Analysis on the Shear Strength equation of RC Column-Steel Beam Joints (RC 기둥과 철골보로 이루어진 복합구조 접합부의 전단강도식에 대한 통계적 고찰)

  • Lee Eun-Jin;Moon Jeong-Ho;Lee Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.443-446
    • /
    • 2005
  • The shear strength equations of the joint with RC column and steel beam are used the proposed equations of ASCE, Kanno and AIJ but there are not applied variable joint details. Until now the variable experimental studies are practiced but the studies of predicted shear strength equation are not integrated and only the applicable equations to each case are proposed. The purpose of this study is statistical analysis for the proposed equations applied existing experiments. The proposed equations are ASCE, Kanno, M-Kanno, AIJ and M-AIJ. The 47 of shear failure experiments are used in this study The consequence is that the Kanno's equation is very analogized with the experimental result but ASCE equation underestimates about 42$\%$. AIJ and M-AIJ are not proper equations for estimating the shear strength of RCS joint.

  • PDF

Experimental Study of Glass Fiber Reinforced Plastic-Steel Connection for Decorative Column (의장적 기둥의 설계를 위한 유리섬유강화플라스틱과 철의 접합부 강도의 실험적 연구)

  • Hwang, Kyung-Ju;Choi, Chui-Kyung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.4
    • /
    • pp.41-47
    • /
    • 2013
  • For the artistic column used by Glass Fiber Reinforced Plastic(GFRP), the connection of steel with GFRP were needed. Due to the fabricating characteristics of hand laminating, GFRP surfaces had to be connected. Because there were no existed data of these connection, experimental study has to be followed so that the structural strength and buckling mode could be investigated. In this paper, therefore, the axial tests of steel with GFRP were performed. The connection of GFRP's surfaces could be also tested as well. As a result, it could be figured out that the strength of these connections were determined by the adhesive strength.

Application Review of the Prediction Method of Early-age Strength with Equivalent Age Method (등가재령방식에 의한 조기강도 예측기술의 적용성 검토)

  • Lee, Jae-Hyun;Jung, Yang-Hee;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum;Jeong, Jae-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.51-52
    • /
    • 2010
  • In this study, it is confirmed that the use of equivalent age method can be applied to predict the early-age strength in case of using the new early strength concrete developed for the reduction of construction work period by our company, in apartment.

  • PDF

Improvement of the Flow Characteristics by Optimizing the Leading-Edge Shape Around Airfoil/Flat-Plate Junction (날개-평판 접합부에서의 날개 앞전 형상 최적화를 통한 유동특성 향상)

  • Cho, Jong-Jae;Kim, Kui-Soon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.6
    • /
    • pp.24-33
    • /
    • 2009
  • The present study deals with the optimization of the leading edge shape around a wing-body junction to minimize the strength of the horseshoe vortex, which is one of the main factor generating the secondary flow losses. For this purpose, approximate optimization method is used for the optimization. The study is performed by using $FLUENT^{TM}$ and $iSIGHT^{TM}$. The total pressure coefficient for the optimized model was decreased about 9.79% compared with the baseline model.

Joints Strength Evaluation of light Structure material (경량 구조재료의 접합강도평가)

  • Jang C. S.;Yi W.;Oh S. K.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.234-238
    • /
    • 2005
  • One approach to testing the suitability of a adhesive joint for a particular application is to build and test to destruction of a representative sample of the joint. The nondestructive test will not measure strength directly but will measure a parameter which can be correlated to the strength. It is therefore, essential that a suitable nondestructive test is chosen and its results are correctly interpreted. In this paper, typical ultrasonic signal analysis in adhesive joints are evaluated together with interface stress from the result of finite element analysis.

  • PDF

A Fundmental Study of the Inlastic Behavior of High Strength Concrete Beam-Column Joints. (고강도 콘크리트를 사용한 보-기둥 접합부의 비 선형 거동에 관한 기초적 연구)

  • Min, J.K.;Park, H.S.;Chung, L.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.51-56
    • /
    • 1990
  • Six small-scale reinforced concrete beam-column joint specimens subjected to monotonic and cyclic loading were tested to investigate the effects of strength of concrete. Variables are 1)compressive strength of concrete(f' c=300, 700kg/㎠), 2)shear span to depth ratio (a/d=4.7, 2.0). The major results of this test were: 1)flexural strength of high strength concrete beam-column joint was not affected too much by the compressive strength of concrete, 2) flexural cracks emerge to inside of beam deeply for high strength concrete member.

  • PDF

The Effects of Flexural Strength Ratio on High Strength Beam-Column Joint Subjected to Reversed Cyclic Loads (반복하중을 받는 고강도 철근콘크리트 보-기둥 접합부의 휨강성비에 관한 연구)

  • 이광수;오정근;문정일;권영호;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.63-67
    • /
    • 1990
  • The purpose of this study was to investigate the effects of flexural strength ratio(Mr=$\Sigma$Mc/$\Sigma$Mb) with High-Strength Concrete up to 800Kg/$\textrm{cm}^2$. Five specimens were tested under reversed cyclic loadings. The primary variables were flexural strength ratio of the beam-column, compressive strength of concrete and loading patterns. The results showed that the failure at the beam-column joint in case of high strength concrete was severe more than in case of normal strength concrete when flexural strength ratio 1.4. Thus the part for low limit of flexural strength ratio(Mr=1.4) should be revised for high strengthconcrete.

  • PDF

Strength Prediction of Interior Beam-column Joint using 3D Strut-Tie Model (3차원 스트럿-타이 모델을 이용한 내측 보-기둥 접합부의 강도 예측)

  • Yun, Young-Mook;Kim, Byung-Hun;Lee, Won-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.405-408
    • /
    • 2004
  • The current design procedures of ACI 318-02, CE3-FIP and NZS 3101 for interior beam-column joints do not provide engineers with a clear understanding of the physical behavior of beam-column joints. In this paper, the failure strengths of the interior beam-column joint specimens tested to failure were evaluated using the 3-dimensional strut-tie model approach, design criteria of ACI 318-02, ACI-ASCE committee 352 and Park and paulay, and softened strut-tie model approach. The analysis results obtained from the 3-dimensional strut-tie model approach were compared with those obtained from the other approaches, and the validity of the approach implementing a 3-dimensional strut-tie model was examined.

  • PDF

Effects of details of lattice reinforcement for punching shear strength of slab-column connections (슬래브-기둥 접합부의 뚫림 전단강도에 대한 래티스 보강상세의 영향)

  • Kim, You-Ni;Park, Hong-Gun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.17-20
    • /
    • 2006
  • A flat plate-column connection is susceptible to brittle punching shear failure, which may result in the necessity of shear reinforcement. In previous, experimental tests were performed to study the capacity of slab-column connections strengthened with various shear reinforcement, and the capacity of the specimens with lattice reinforcement are superior to the others. In present study, to study for effects of details of lattice reinforcement, experimental studies was performed. Main parameters are the amount of lattice shear reinforcement, arrangement of lattice and the effect of flexural re-bar. And capacity of the specimen with small amount of lattice reinforcement was higher than the capacity of other shear reinforcement.

  • PDF