• Title/Summary/Keyword: 접촉강도

Search Result 468, Processing Time 0.029 seconds

Property Studies of PAN/PVdF Composite Nanofiber Manufactured from Electrospinning (전기방사법으로 제조된 PAN/PVdF 복합나노섬유의 특성연구)

  • Yun, Jung-Hyun;Choi, Dong-You
    • 전자공학회논문지 IE
    • /
    • v.46 no.3
    • /
    • pp.6-11
    • /
    • 2009
  • In this paper, manufactured composite nanofiber by electrospinning that make spinning solvent according to weight of PAN/PVdF. PVdF content of composite nanofiber decreases, diameter of fiber decreased. Result that measure contact angle to confirm hydrophile property of PAN/PVdF composite nanofiber, PVdF content increases, could confirm that contact angle with water increases. After leave filter measurement sample for 25 hours in temperature of $40^{\circ}C$, humidity of 85%, result PAN/PVdF composite nanofiber that estimate efficiency could confirm that display performance of HEPA more than 99.95% and ULPA more than 99.999%. And fiber diameter is small, could confirm that filter performance increases. Tensile strength of bulk of PAN/PVdF composite nanofiber was 5-8MPa, expansion 100-300%. And strength and expansion could know that increase according as PVdF's content increases. Tensile strength was 3-8MPa degree after annealing PAN/PVdF composite nanofiber during 2 hours in 120t. Tensile strength was no change almost by annealing, and expansion could know that decrease.

Wear Resistance of Crosslinked Ultra-high Molecular Weight Polyethylene (가교된 초고분자량 폴리에틸렌의 내마모성)

  • Im, Chae-Ik;Lee, Gwi-Jong;Jo, Jae-Yeong;Choe, Jae-Bong;Choe, Gwi-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.99-106
    • /
    • 1999
  • Ultra-high molecular weight polyethylene (UHMWPE) was crosslinked in the melt state to enhance wear resistance, Dicumyl peroxide (DCP) and triallyl cyanurate (TAC) was used as a crosslinking agent and a promoter, respectively. With increasing amount of DCP and TAC used, gel content of crosslinked UHMWPE (XUMPE) increased, while the melting temperature, crystallizaiton temperature, crystallinity, and tensile properties decreased. The results of pin-on-disk wear test and ball-on-disk test with small applied load showed reduced wear volumes of XUMPE from that of the unmodified UHMWPE. As the wear mechanism effected in the experimental condition of this study was thought to be deformation rather than adhesion or fatigue, a new parameter, the ratio of maximum contact stress to yield stress, was proposed to correlate well with observed wear resistance. In ball-on-disk wear test with larger applied load, XUMPE showed higher wear volumes than that of the unmodified UHMWPE which were accompanied with increased friction coefficients and surface roughness of the wear tracks. When contact stress was well above yield stress, the failure of XUMPE, as well as deformation, was thought to be much accelerated.

  • PDF

An Experimental Study of Strength Evaluation in Frozen Soils according to Direct Shear Box Systems (직접전단상자 시스템에 따른 동결토의 강도 평가에 관한 실험적 연구)

  • Kim, Sang Yeob;Kim, YoungSeok;Lee, Jangguen;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.3
    • /
    • pp.5-14
    • /
    • 2017
  • Experimental study on strength characteristics of frozen soils is necessary for the safety evaluation of design and construction in cold region. The objective of this study is to evaluate the direct shear strength of frozen soils obtained from traditional system (Type-1), system with roller on the upper shear box (Type-2), and system with fixed upper shear box separated from bottom shear box (Type-3). Specimens mixed with sand, silt, and water are frozen to $-5^{\circ}C$, and then direct shear tests are conducted under the normal stress of 5, 10, 25, and 50 kPa. Experimental results show that the upper shear box of Type-1 touches the bottom shear box due to the rotation of the upper shear box. The shear strength obtained from Type-2 is overestimated because the preventing rotation force is added to shear force. Type-3 may acquire the only strength of the specimen, and shear strain at peak shear strength is similar to that at the beginning of vertical displacement occurrence. In addition, internal friction angle and cohesion at both peak and residual stresses in Type-3 are smaller than those of Type-2. This study shows that high strength specimens including frozen soils can be effectively evaluated using improved shear box system such as Type-3.

A Study on the Effect of Pile Surface Roughness on Adfreeze Bond Strength (말뚝표면 거칠기에 따른 동착강도 변화에 관한 연구)

  • Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.79-88
    • /
    • 2011
  • Adfreeze bond strength develops upon freezing of pore water within soil and at foundation surface. It has been reported that various factors like temperature, soil type, and pile surface roughness affect adfreeze bond strength. Especially, pile surface roughness has been considered as a primary factor to design pile foundation in frozen ground. It has usually been estimated with fixed correction factors for pile materials. However, even if the pile foundation material is the same, the surface roughness could vary depending on the production circumstances. In this study, laboratory test was carried out to quantitatively analyze the effects of surface roughness on the adfreeze bond strength, and fractal dimension was used as a measure for surface roughness. Test results showed that adfreeze bond strength increased with decreasing temperature, increasing vertical stress and surface roughness. The adfreeze bond strength varies sensitively with surface roughness in the early freezing section of $-2^{\circ}C$, but its sensitivity decreased in the temperature ranging between $-2^{\circ}C$ to $-5^{\circ}C$. The results conclude that the roughness highly affects the frictional resistance of pile surface in frozen ground; however, the roughness does not affect considerably when the temperature drops below about $-2^{\circ}C$.

Characteristics of Pore Structures and Compressive Strength in Calcium Leached Concrete Specimens (칼슘이 용출된 콘크리트의 공극 구조 및 강도 특성)

  • Yang, Eun-Ik;Choi, Yoon-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.647-656
    • /
    • 2011
  • In radioactive waste repositories constructed in underground, concrete member could be in contact with groundwater for a long time. However, this pure water creates concentration gradients which lead to the diffusion of Ca ions from the pore water and the degradation of underground concrete. Therefore, this study is aimed at investigating the alteration of pore structure and loss of compressive strength associated with dissolution. The results showed that as the leaching period became longer, the pore volume within 50 nm to 500 nm in diameter is greatly increased. Also, the volume of pores larger than 200 nm rapidly increased during initial leaching time and those below 200 nm gradually increased. Furthermore, the compressive strength gradually decreased with increase of degraded thickness. The residual strength of the degraded concrete with OPC was in the range of 33% to 58%.

Interfacial shear strength test by a hemi-spherical microbond specimen of carbon fiber and epoxy resin (탄소섬유/에폭시의 반구형 미소접합 시험편에 대한 계면강도 평가)

  • Park, Joo-Eon;Gu, Ja-Uk;Kang, Soo-Keun;Choi, Nak-Sam
    • Composites Research
    • /
    • v.21 no.4
    • /
    • pp.15-21
    • /
    • 2008
  • Interfacial shear strength between epoxy and carbon fiber was analyzed utilizing a hemi-spherical microbond specimens adhered onto single carbon fiber. The hemi-spherical microbond specimen showed high regression coefficient and small standard deviation in the measurement of interfacial strength as compared with a droplet and an inverse hemi-spherical one. This seemed to be caused by the reduced meniscus effects and the reduced stress concentration In the region contacting with a pin-hole loading device. Finite element analysis showed that the stress distributions along the fiber/matrix interface in the hemi-spherical specimen had a stable shear stress distribution along the interface without any stress mode change. The experimental data was also different according to the kinds of loading device such as the microvise-tip and the pin-holed plate.

Non-contact Measurement and Analysis of Surface Hardness on Welding Steel using Laser-induced Breakdown Spectroscopy (레이저 유도 플라즈마 분광 기법을 이용한 용접 연강에서의 비접촉 강도 측정과 해석)

  • Kim, Joohan;Ko, Chansol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.2
    • /
    • pp.141-148
    • /
    • 2014
  • In this work, effects of plasma on different hardness of welding steel using laser-induced breakdown spectroscopy were investigated. The ratios of ionic to atomic spectrum peaks were related to its material hardness. The major spectrum peak (Fe) and minor spectrum peak (Mn) were considered as monitoring elements. The stronger repulse plasma was generated, the harder material it was. The ratios of ionic to atomic spectrum peaks increased with respect to the material hardness as well. The correlation of minor spectrum peaks was stronger than that of major spectrum peaks. However, the major spectrum peaks indicated a similar trend, which could be used to estimate the hardness, too. Based on this result, the method could be used as a non-contact remote measurement of material properties.

A study on Insulation Characteristics on Contact Force of Main Contact of Gas Insulated Switchgear (초고압 차단기 메인 접점의 압점력에 따른 절연 특성 연구)

  • Shin, Hansu;Kim, Myounghoo;Oh, Jinseok;Hwang, Dongik;Lim, Hyoungwoo;Cha, Gueesoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.431-432
    • /
    • 2015
  • 본 논문은 초고압 가스절연개폐장치의 메인 접점의 압점력에 따른 절연 특성에 대한 연구이다. 차단기 접점의 접촉이 잘 이루어지지 않는 현상이 발생하게 되면 접촉저항이 증가하여 차단기의 투입 및 개방 시에 전류에 의하여 접점에 손상이 발생한다. 그리고 차단기의 접점의 압점력이 커질수록 큰 조작력이 필요하므로 차단기의 동작에도 영향을 미치는 것은 많이 알려져 있다. 그러나 압점력과 절연 특성의 관계에 대한 연구가 미비하므로 이에 대한 연구가 필요하다. 본 연구는 초고압 가스절연개폐장치의 메인 접점의 압점력에 차이에 따른 전계를 해석하고, 고정측 접점의 쉴드 유무에 따른 절연 내력을 비교 및 분석하였다. 전계 해석 결과를 통해서 메인 접점의 압점력과 절연특성과 고정측 접점 쉴드의 영향을 비교함으로써 차단기 인터럽터 내부의 전계 분포를 확인하고, 전계 강도를 확인함으로 가스절연계폐장치의 적절한 절연내력 확보를 목적으로 한다.

  • PDF

Study on the Development of Road Icing Forecast and Snow Detection System Using State Evaluation Algorithm of Multi Sensoring Method (복합 센서의 상태 판정 알고리즘을 적용한 노면결빙 예측 및 강설 감지 시스템 개발에 관한 연구)

  • Kim, Jong-Woo;Jung, Young-Woo;Nam, Jin-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.113-121
    • /
    • 2013
  • The road icing forecast and snow detection system using state evaluation algorithm of multi sensor optimizes snow melting system to control spread time and amount of chemical spread application This system operates integrated of contact/non-contact sensor and infrared camera. The state evaluation algorithm of the system evaluates road freezing danger condition and snowfall condition (snowfall intensity also) using acquired data such as temperature/humidity, moisture detection and result of image signal processing from field video footage. In the field experiment, it proved excellent and reliable evaluated result of snowfall state detection rate of 89% and wet state detection rate of 94%.

Reliability analysis of LNG unloading arm considering variability of wind load (풍하중의 변동성을 고려한 LNG 하역구조물의 신뢰성해석)

  • Kim, Dong Hyawn;Lim, Jong Kwon;Koh, Jae Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.2
    • /
    • pp.223-231
    • /
    • 2007
  • Considering wind speed uncertainty, reliability analysis of the LNG unloading arm at Tongyoung Production Site was performed. Extreme distribution of wind speed was estimated from the data collected at the weather center and wind load was calculated using wind velocities and coefficients of wind pressure. The unloading arm was modeled with plate and solid elements. Contact elements were used to describe the interface between base of structure andground. Response surface for maximum effective stress was found for reliability analysis and then reliability functions was defined and used to determine exceeding probability of allowable and yield stresses. In addition, sensitivity analysis was also performed to estimate the effect of possible material deterioration in the future.