• 제목/요약/키워드: 접착레진

검색결과 329건 처리시간 0.048초

접착성(接着性) 레진이 가견치수조직(家犬齒髓組織)에 미치는 독성(毒性)에 관(關)한 실험적(實驗的) 연구(硏究) (TOXIC EFFECT OF ADHESIVE RESINS ON THE DOG'S PULP TISSUE)

  • 손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.31-42
    • /
    • 1984
  • The toxic effect of adhesive resins on the dog's pulp tissue was studied with 70 teeth from 5 dogs. The experimental materials were Clearfil, a mixture of Clearfil with calcium hydroxide powder, Panavia-EX, and a mixture of Panavia-EX with calcium hydroxide powder. As a control group, calcium hydroxide powder was used. Each material was placed on the pulpotomized tissue surface. After 3 days, 1, 2,4, and 6 weeks, the teeth and apical tissue were processed routinly and stained with hematoxylin and eosin. Pathological tissue changes due to the toxicity of adhesive resins were observed by light microscope, and the pH of Panavia-EX and the Bonding agent of Clearfil were measured. Following were the results; 1. In the group of calcium hydroxide powder, slight inflammatory change was observed in the pulpotomized surface and adjacent pulp tissue on 3 day. 1 week case showed incomplete dentin bridge. The remaining pulp tissue was normalized according to the days elapsed. 2. In the group of Clearfil, early inflammatory change revealed in the superificial portion of the remaining pulp tissue on 3 day. The inflammation spreaded over the total pulp tissue and partial necrosis was observed in 1 week and 2 week cases. Total necrosis of pulp tissue and moderate inflammatory change at the apical tissue was noticed in 4 week and 6 week cases. 3. In the group of Panavia-EX, moderate inflammatory change appeared in the superficial pulp tissue on 3 day, and severe inflammatory change over all pulp tissue found in 1 week case. Pulp necrosis was obvious in 2 week case. 4 week and 6 week cases were totally necrotized up to the periapical tissue. 4. In the groups of mixtures with calcium hydroxide powder, the pulp tissue destruction was retarded, compared with the groups of Clearfil and Panavia-EX. 5. Panavia-EX was more destructive than Clearfil. 6. The acidity of freshly mixed Bonding agent of Cleafil was pH 4.0, and that of Panavia-EX was pH 2.0.

  • PDF

유구치 아말감 수복물에서 레진 접착성 이장재의 미세 변연 누출에 관한 비교 연구 (AN EXPERIMENTAL STUDY FOR MICROLEAKAGE OF AMALGAM USING RESIN ADHESIVE LINERS IN PRIMARY MOLAR TOOTH)

  • 김종태;최병재;이제호;이종갑
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.401-414
    • /
    • 1996
  • The purpose of this study was to compare the marginal leakage of resin liner which was used as a liner to amalgam restoration. Control group composed of no liner group, copalite group and experimental group composed of All-bond 2, Vitrebond, Superbond D-liner applied groups were evaluated. Cl.V preparation with a size of $3{\times}2{\times}1.5mm$ on 70 extracted primary molars were made and applied appropriate liners for each groups. After amalgam filling and polishing, polished specimens underwent temperature changed from $5^{\circ}C\;to\;55^{\circ}C$ a thousand times. After thermocycling, specimens were placed in 2% methylene blue dye solution for 72 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a spectroscopy. (${\times}30$) The following results were obtained. 1. Vitrebond, All-bond 2, Superbond D-liner group exhibited a statistically significant lower degree of dye penetration than no liner and copalite group. (Kruskal-Wallis analysis, P<0.05) 2. No liner group and copalite group exhibited a similar degree of dye penetration. (Mann-Whitney analysis, P>0.05) 3. All-bond 2 group exhibited a statistically significant lower degree of dye penetration than Vitrebond group, (Mann-Whitney analysis, P<0.05) Superbond D-liner group also exhibited a lower degree of dye penetration than Vitrebond group but was statistically insignificant. (Mann-Whitney analysis, P>0.05)

  • PDF

원자력현미경을 이용한 나노임프린트 재료의 접착력 측정 (Adhesion Force Measurements of Nano-Imprint Materials Using Atomic Force Microscope)

  • 윤형석;이몽룡;송기국
    • 폴리머
    • /
    • 제38권3호
    • /
    • pp.358-363
    • /
    • 2014
  • 원자력현미경(AFM) tip을 표면 처리하여 임프린트용 acrylate 레진과의 접착력을 측정하였다. 표면 처리를 하지 않은 실리콘 tip에 비하여 $CH_4$ 플라즈마로 소수성 처리한 경우 접착력은 38% 감소한 반면 친수성의 $O_2$ 플라즈마로 처리한 경우에는 접착력이 1.6 배 증가하였다. 이러한 AFM 결과들은 정성적 실험 결과 밖에 얻을 수 없는 cross-cut 접착실험에 비하여 매우 구체적인 정량적 결과들을 제공하였다. 나노 크기의 임프린트 패턴을 전사하는 경우, 몰드와 레진 사이 접촉 면적이 커져서 시료 전체의 접착력이 커지기 때문에 패턴 크기가 작아지는 나노임프린트 공정에서는 몰드 표면 처리 문제가 더욱 중요하게 되는 것을 알 수 있었다.

복합레진과 Glass Ionomer Cement수복물에 대한 Bracket의 접착전단강도 (THE SHEAR BOND STRENGTH OF TWO ADHESIVES BONDED TO COMPOSITE RESIN AND GLASS IONOMER CEMENT RESTORATIONS)

  • 한재익;이병태
    • 대한치과교정학회지
    • /
    • 제20권3호
    • /
    • pp.583-591
    • /
    • 1990
  • If the bond strength is sufficient to resist orthodontic force, orthodontic brackets can be bonded to restorations. Orthodontic brackets were bonded to composite resin and glass ionomer cement restorations with no-mix adhesive or glass ionomer cement. The shear bond strength of adhesives bonded to restorations was studied in vitro. Orthodontic brackets were bonded to 10 extracted natural teeth, 40 composite resin restorations and 40 glass ionomer restorations. The surfaces of composite resin restorations were roughened or applied with bonding agent (Scothbond) after surface roughening. The surfaces of glass ionomer cement restorations were conditioned with acid etching or applied with Scotchbond to etched surface. The adhesive was no-mix resin or glass ionomer cement. The shear bond strength was measured. The results were as follows: 1. Orthodontic brackets could be bonded to composite resin restorations effectively as they could be bonded to acid etched enamel with no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was not affected by bonding agent greatly. 2. The shear bond strength of no-mix adhesive bonded to acid etched glass ionomer cement restorations was sufficient to resist orthodontic force. However. the fracture risk of glass ionomer cement restorations was increased during debonding. The bonding agent couldn't increase the shear bond strength greatly. 3. The shear bond strength of glass ionomer cement bonded to glass ionomer cement restorations was lower than that of no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was greatly decreased by bonding agent. 4. The shear bond strength of glass ionomer cement bonded to composite resin restorations was too low to resist orthodontic force.

  • PDF

Silicoating후 시간지연이 금속과 레진 시멘트 간의 접착강도에 미치는 영향 (THE EFFCT OF TIME DELAY AFTER SILICOATING ON THE BOND STRENGTH BETWEEN THE METAL AND RESIN CEMENT)

  • 양진경;배정식
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.1-12
    • /
    • 1995
  • For the purpose of this study, the silicoating on Ni-Cr-Be alloy surface was carried out by using the Silicoater MD. The effect of time delay after silicoating on the bond strength between the metal and resin cement was examined. The groups were divided into 4 : group 1 : Sandblasted with $250{\mu}m$ aluminium oxide, immediatly cemented group 2 : Sandblasted with $250{\mu}m$ aluminium oxide, silicoated and immediatly cemented group 3 : Sandblasted with $250{\mu}m$ aluminium oxide, silicoated and cemented after 7 days group 4 : Sandblasted with $250{\mu}m$ aluminium oxide, silicoated and coated with unfilled resin and cemented after 7 days Specimens were luted with Comspan, Superbond C&B or Panavia EX. The tensile bond strength between the metal and resin cement was measured by using the universal testing machine. The results were as follows : 1. The bond strength in groups 2, 3 and 4 was higher than that of group 1 (p<0.05). There was no statistically significant difference among the bond strength in groups 2, 3 and 4 (p>0.05). 2. In Comspan-cemented groups, there was no significant difference among the bond strength in groups 2, 3 and 4 (p<0.05). 3. In Panavia EX-cemented groups, the bond strength of group 3 was higher than that of group 2 (p<0.05) and there was no significant difference between groups 3 and 4. 4. In Superbond C&B-cemented groups, there was significant difference between groups 2 and 3 (p<0.05) and the bond strength of group 4 was higher than that of group 3 (p<0.05). 5. The highest tensile bond strength was obtained by using the Superbond C&B and no difference in the Panavia EX and Comspan. 6. The modes of bond failure were mainly cohesive failure. The method of storage and transport indicated in this study seems recommendable for laboratory and clinical use at least up to 7 days.

  • PDF

상부구조물과 금원주를 레진시멘트로 접착시킨 임프란트 보철물의 파절에 대한 연구 (A STUDY ON FAILURE STRENGTH OF THE IMPLANT PROSTHESIS LUTED WITH RESIN CEMENT BETWEEN GOLD CYLINDER AND SUPERSTRUCTURE)

  • 김승범;배정식
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.438-447
    • /
    • 1996
  • This study was performed to determine the failure strength and pattern of implant prosthesis luted with resin cement between gold cylinder and superstructure, and to evaluate the bonding strength of resin cement. To evaluate failure strength and pattern, the groups were divided into 2. Group 1 : Casted gold cylinder Group 2 : Luted with resin cement between gold cylinder ans superstructure. To evaluate effects of the bonding strength of the implant prosthesis luted with resin cement according to storage condition, the groups were divided into 3 : Group A : Stored in waste at $37^{\circ}C$ for 24 hours. Group B : 1000 cycles thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ in water. Group C : Stored in water at $37^{\circ}C$ for 30 days. The results were as follows. 1. Failure was found at gold screw in all specimens of group 1 & 2. 2. The bond strength in group 1 and 2 was 189.86 and 188.14kgf. There was no statistically significant difference between group 1 and 2(P>0.05). 3. The bond strength of group A, B and C was 53.28, 45,86 and 39.29Kgf. There result suggest the advantage of an improved fit of superstructure to the abutment and a simple procedure. But there was a measurable decrease of the bond strength according to storage condition. So, Further research is necessary to evaluate of the implant prosthesis luted with resin cement between gold cylinder and superstructure.

  • PDF

점도, 시편형태 그리고 접착의 유무가 광중합 복합레진의 선형중합수축의 측정에 미치는 영향 (THE EFFECT OF VISCOSITY, SPECIMEN GEOMETRY AND ADHESION ON THE LINEAR POLYMERIZATION SHRINKAGE MEASUREMENT OF LIGHT CURED COMPOSITES)

  • 이인복;손호현;권혁춘;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.457-466
    • /
    • 2003
  • The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow-were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bond-ed' free shrinkage method at varying C-factor in the range of 1∼8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. In non-bonded method, the linear shrinkage approximated one third of true volumetric shrink-age by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5∼6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.

인공타액오염이 유치 상아질에서 3종 상아질 접착제의 결합 강도에 미치는 영향 (Effects of Artificial Saliva Contamination on the Bond Strength of Three Dentin Adhesives to Dentin of Primary Teeth)

  • 배영은;김신;정태성;김지연
    • 대한소아치과학회지
    • /
    • 제44권1호
    • /
    • pp.72-81
    • /
    • 2017
  • 본 연구의 목적은 유치 상아질의 복합레진 술식에서 각 단계별로 치면에 인공타액이 오염되었을 때와 이것을 제거하는 방법이 한 단계 자가부식 접착제와 두 단계 산 부식 접착제의 결합강도에 미치는 영향을 비교 분석하는 것이다. 연구 목적을 달성하기 위해, 건전한 유구치 42개를 선정하여 세 종류의 상아질 접착제인 Scotchbond Universal Adhesive(SBU), All-Bond Universal(ABU)과 Prime & Bond NT(PNT)에 따라 3개의 군으로 분류하였다. 이를 다시 각 접착제에서 7개의 하위 그룹으로 나누었다. 대조군인 1군을 제외한 나머지 군은 인공타액으로 오염시킨 군으로 다음과 같이 분류하였다: 2, 3군 - 접착제 도포 전; 4, 5군 - 접착제 중합 전; 6, 7군 - 접착제 중합 후. 인공타액은 수세, 건조(2, 4, 6군)와 건조(3, 5, 7군)로 제거하였다. 처치된 치면에 복합레진(Filtek, Z-350)으로 수복하고 시편을 제작한 후 미세인장 결합강도(Microtensile bond strength, MTBS)를 측정하였다. One-way ANOVA와 Tukey HSD test를 이용해서 통계분석을 실시하였다(p < 0.05). 대조군에서 MTBS의 평균값은 PNT가 ABU와 SBU에 비해 높게 나타났다(p < 0.001). 세 가지 접착제의 각 오염단계에서 수세와 건조를 시행했을 때(2, 4, 6군)가 건조만 시행했을 때(3, 5, 7군)보다 높은 결합강도를 나타내었다. 그리고 접착제 중합 전 단계에서 인공타액의 오염이 발생했을 때(4, 5군)는 대조군에 비해 낮은 MTBS를 보였다(p < 0.001). 전반적으로 두 단계 산 부식 접착제가 한 단계 자가부식 접착제에 비해 높은 MTBS를 보였다. 접착제를 중합하기 전 단계에서 인공타액에 오염되었을 경우에는 접착 강도가 현저히 감소하였고, 수세와 건조 과정으로 접착강도를 회복할 수 없었다.

타액 및 혈액오염 시 유치 지르코니아 기성관 내면의 세척 방법에 따른 결합강도의 비교 (Comparison of Bonding Strength by Cleaning Method of Pediatric Zirconia Crown Contaminated with Saliva or Blood)

  • 김재용;박호원;이주현;서현우
    • 대한소아치과학회지
    • /
    • 제45권2호
    • /
    • pp.185-194
    • /
    • 2018
  • 본 연구의 목적은 타액이나 혈액에 오염된 유치 지르코니아 기성관의 내면을 다양한 세척 방법으로 세척 한 뒤, 레진 시멘트와의 결합력을 비교하고, 열 순환이 결합력에 미치는 효과를 평가하였다. 지르코니아 기성관의 내면과 유사한 상태의 지르코니아 절편($5mm{\times}3mm$)을 아크릴릭 레진에 매몰하였다(n=180). 이 중 160개의 시편을 무작위로 두 군으로 나누어 타액 오염과 혈액 오염을 시행하였다. 양성 대조군은 오염 과정을 거치지 않고 resin cement로 접착을 시행하였고, 음성 대조군은 오염 후 dental unit chair 상의 물로 20초간 세척 후 10초간 건조를 시행하였다. 타액 오염된 시편과 (n=60) 혈액 오염된 시편(n=60)은 각각 세 가지 방법의 세척을 시행하였다. 37% 인산 젤, 상용 세척제(Ivoclean), 2.5% NaOCl을 각 시편에 20초간 적용 후 10초간 물로 세척하고 건조를 시행하였다. 이 후 모든 시편(n=160)에 접착을 시행하였다. 대조군과 각 실험군을 모두 절반으로 나누어 절반은 바로 전단응력을 측정하였고, 절반은 열 순환 과정 후 전단응력을 측정하였다. 타액오염과 혈액오염을 시행한 군 모두에서, 양성 대조군과 상용 세척제, 2.5% NaOCl으로 세척한 군에서 통계학적으로 유의한 차이는 존재하지 않았다. 음성 대조군과 37% 인산 젤로 세척한 군의 전단 결합 강도는 양성 대조군과 비교하였을 때, 유의하게 감소하였다. 열 순환 시행 시 타액 오염을 시행한 군과 혈액 오염을 시행한 모든 군에서 열 순환을 시행하지 않은 군보다 통계적으로 유의하게 낮은 전단 응력 간도를 나타내었다. 유치 지르코니아 기성관 내부의 타액 오염이나 혈액 오염 시, 상용 세척제나 2.5% NaOCl로 세척을 시행하면 원래의 전단응력 값을 얻을 수 있다. 열 순환 시행 시 모든 군에서 유의하게 낮은 전단 응력 값을 보였다.

임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향 (The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses)

  • 신황규;송영균;신수연
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.125-140
    • /
    • 2011
  • 보철물을 기능적으로 평가하기 위해 임시 시멘트로 임시 합착을 한 경우 보철물 내면의 잔여 임시 시멘트는 레진 시멘트를 이용한 최종 합착에 있어서 부정적인 영향을 미칠 수 있다. 이에 본 연구는 다양한 임시 시멘트 제거 방법과 임시 시멘트의 잔여 성분이 임플란트 전용 레진 시멘트와 보철물의 유지력에 어떠한 영향을 미치는지를 알아보고자 하였다. 임플란트 지대주는 일반적인 시멘트 유지형 보철물 제작에 사용되는 높이 5.5 mm, 직경 4.5mm, 6도의 축면 경사도와 chamfer 변연을 갖는 기성품(Solid abutment, GSRAS4621, Osstem Implant Co., Busan, Korea)을 사용하였다. 40개의 주조시편을 제작하여 합착 전 70 psi하에 공기입자 분사법을 시행하였고, 10개의 시편을 임시 시멘트의 합착과정 없이 바로 최종 시멘트로 합착하여 대조군으로 설정하였으며 나머지 시편을 각 10개씩 임시 시멘트 제거를 위하여 오렌지 솔벤트를 이용한 군, 초음파 세척을 이용한 군, 공기입자 분사법을 이용한 군으로 나누었다. 임시 시멘트의 합착과 분리 후 제거과정을 거쳐 최종 시멘트로 임플란트 전용 시멘트($Premier^{(R)}$ Implant $Cement^{TM}$, Premier Co., PA, U.S.A.)를 사용하여 최종 합착을 실시하였다. 각 시편은 10분간 5 kg의 하중 하에 합착하였으며 열순환을 거쳐 만능시험기에서 분당 0.5 mm의 속도로 인장접착강도를 측정하였다. 측정이 끝난 뒤 모든 시편을 초음파 세척과 공기입자 분사법, 증기 세척의 과정을 통해 내면의 잔여 성분을 제거하였다. 완전 건조 후 비유지놀계 임시 시멘트를 사용하여 다시 임시 합착, 분리를 거친 후 동일한 실험 과정을 반복하였고 인장접착강도를 측정하여 다음의 결과를 얻었다. 오렌지 솔벤트를 사용한 군이 가장 작은 유지력을 나타냈으며 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군과 비교시 통계적으로 유의한 차이가 있었다(p<0.05). 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군 간의 비교시 통계적으로 유의한 차이가 없었다. 오렌지 솔벤트를 사용한 군은 대조군과 비교시 통계적으로 유의한 차이가 있었으며(p<0.05), 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군은 대조군과 비교시 통계적으로 유의한 차이가 없었다. 임시 시멘트의 유지놀 성분의 유무에 따른 비교시 통계적으로 유의한 차이가 없었다. 이상의 결과로부터 임시 시멘트 제거를 위해 오렌지 솔벤트만을 사용하는 것은 임플란트 전용 시멘트를 사용한 최종 합착시 유지력 감소의 원인이 될 수 있음을 알 수 있었으며, 임플란트 보철물 내면의 임시 시멘트를 효과적으로 제거하기 위한 방법으로 초음파 세척법, 공기 입자 분사법, 또는 이들의 복합적인 사용이 필요함을 알 수 있었다.