• Title/Summary/Keyword: 접지전류

Search Result 337, Processing Time 0.035 seconds

Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems (배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Kim, You-June;Choi, Jong-Ki;Baek, Nam-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.67-74
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the ground impedance of Magic rods which are commercially available has been measured in frequency ranging from 0[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Ground Impedance Characteristics Analysis of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 동봉 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Oh, Jung-Suk;Park, Sang-Young;Choi, Jong-Ki;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.46-51
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. A cower rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of cower rods has been measured in frequency ranging from 60[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

접지설비

  • 배석명
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.335
    • /
    • pp.37-52
    • /
    • 2004
  • 접지설비는 다른 설비에 비해서 단지 부속설비처럼 안이하게 취급하는 경우가 많다. 그러나 접지설비는 전로의 이상전압을 억제하고 지락시의 고장전류를 안전하게 대지로 흘려 인체의 보호나 화재, 기기의 손상 등의 재해를 방지하는 것뿐만 아니라 제어기기를 안정하게 동작시키는 등의 역할을 위한 필수불가결한 설비이다. 특히 최근 전자기기의 급격한 증가에 따라 안정된 신호계를 확보하기 위한 접지설비가 다양화, 혼재화하고 있다. 접지를 하여야 할 설비에는 전력설비, 정보$\cdot$통신설비(신호, 제어, 유무선통신, 컴퓨터 등), 피뢰설비(피뢰침, 피뢰도선, 가공지선 등)를 비롯하여 정전기 제거설비, 유도장해 방지설비 등 여러 가지 설비가 있다. 접지는 기본적으로 대지에 전기적 단자를 접속하는 것으로 즉, 금속 등의 도전성 물체를 대지와 전기적으로 접속하여 도전성물체의 전위를 대지와 같은 전위 또는 전위차를 최소화시키는 것을 말한다. 금속체와 대지를 접속하는 단자의 역학을 하는 것이 접지전극(Grounding electrode)이라고 하며 보통은 지중에 매설되어 있는 도체가 사용된다. 접지전극과 접지를 하는 설비를 연결하는 도선을 접지도선 또는 접지선(Grounding conductor)이라고 한다. 따라서 접지설비를 설계하기 위해서는 접지의 목적, 기능, 종류를 정확하게 이해하여 접지시스템을 구축함과 동시에 적절한 접지개소, 접지선, 접지극을 선정하고 시공하여야 한다.

  • PDF

Stray Electric Field Energy Harvesting for Power Supply of Ubiquitous Sensor Network (유비쿼터스 무선 센서 네트워크의 전력공급을 위한 표유전계에너지 하베스팅 기술 연구)

  • Chang, Keun-Su;Kang, Sung-Muk;Park, Kyoung-Jin;Shin, Seung-Hwan;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1310-1311
    • /
    • 2011
  • 본 논문에서는 신개념의 에너지 하베스팅 기술로서 전력선의 표유전계에너지 하베스팅을 제안하였고, 저전력 무선 센서노드에 전력공급이 가능함을 실험적으로 확인하였다. 전류가 흐르지 않는 무부하 상태의 220 V 전력선에 20 cm 길이의 알루미늄 포일을 감아서 하베스팅 할 때, 하베스터 회로의 접지가 220 V 전력선의 접지선에 연결되어 있는 경우, 수집 가능한 평균전류는 900 nA, 연구실 콘크리트 바닥에 접지되어 있을 경우, 700 nA의 평균전류를 얻을 수 있음을 확인하였다. 콘크리트 바닥에 접지되어 있는 하베스터 회로의 경우 220 V 전력선으로부터 접지선을 따로 빼 낼 필요가 없기 때문에 충분히 실용적이며 알루미늄 포일의 길이를 60 cm로 느리면 약 2분 만에 저전력 무선 센서노드 구동을 위해 필요한 에너지인 약 2 mJ 만큼 하베스팅이 가능하다. 본 기술을 적용하면 유비쿼터스 센서 네트워크의 전력을 공급할 수 있을 것으로 사료된다.

  • PDF

The study on the spaced grounding conductor (접지도체 간격에 관한 연구)

  • Choi, Hong-Kyoo;Choi, Byoung-Sook;Song, Young-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.140-147
    • /
    • 2004
  • 등간격 접지Grid의 설계에서는 대부분의 전류가 외곽접지도체로 누설되어 Grid 구석 접촉전압이 중심 접촉전압 보다 높아지는 문제점이 있다. 비등간격 접지Grid의 설계는 이러한 문제점을 극복할 수 있으나 적절한 비등간격 접지Grid의 설계방법이나 간격결정 방법은 논의되고 있지 않다. 따라서, 본 논문에서는 비등간격 접지Grid의 장점, 수식, 최적의 간격비율을 제시한다.

  • PDF

Design and Fabrication of a Surge Impedance Meter (서지임피던스 측정기의 설계 및 제작)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Kim, Il-Kwon;Moon, Byung-Doo;Kim, Hwang-Kuk;Park, Chan-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.645-649
    • /
    • 2007
  • Ground systems flow fault currents into the ground, and suppress Ground Potential Rise (GPR) by the current. In this paper, we designed and fabricated a surge impedance meter to analyze the ground impedance in wide frequency ranges. The meter consists of a surge generator, a high speed sample/hold (S/H) circuit and an associated electronics. The surge generator produces surge voltage up to 5kV in ranges of $50\sim500ns$. Field tests were carried out to evaluate the surge impedance meter at a driven-rod ground system. The results showed that surge impedance of ground systems should be measured by various fast surge waveforms, since the impedance increases as the rise time of applied voltage increases.

Relative Error Analysis for Measuring Value of Ground Resistance according to Position Variation of Potential Probe) (전위보조전극의 위치변화에 따른 접지저항 측정값의 상대오차분석)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.96-102
    • /
    • 2009
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error for measuring value of ground resistance due to the position of the potential probe, ground resistance were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from l0[m] to 50[m]. Also, the potential probe was located at 30[$^{\circ}$], 45[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$] and 180[$^{\circ}$]. As a consequence, relative error decreased with increasing the distance of potential probe and decreasing the angle between current probe and potential probe. The results could be help to determine the position of potential probe when the ground resistance was measured at grounding system.

Shunt Current Measurements for Grounding System of Commercial Frequency (상용주파 접지시스템의 분류전류 측정기술개발)

  • Kim, Jae-Yee;Ko, Young-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.223-224
    • /
    • 2002
  • 본 논문에서는 운전중인 변전소접지계의 분류전류를 측정하는 기법을 개발하고자 한다. 접지계의 안전성을 진단하기 위해서는 분류전류의 정확한 측정이 필수적이다. 모델변전소로 최근 부하 밀집지역인 도시지역에 가장 많이 채택하고 있는 옥내 지중변전소를 선정하였다. 가장 악조건인 1차측 지중선로 1회선인 경우 지중선로 분류율의 계산치 및 실측치가 각각 85.60[%]및 84.43[%]로 잘 일치하였다.

  • PDF

A Study on the Application of Temporary Fence as a Ground Electrode (접지전극으로서의 가설울타리 활용방안에 관한 고찰)

  • Park, Sung-Yeol
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.127-128
    • /
    • 2023
  • 본 논문에서는 건설현장에 설치하는 가설울타리와 접지동봉을 매설하여 접지저항을 측정하였다. 접지저항을 측정한 결과 접지동봉은 10.8Ω이고, 가설울타리는 2.07 Ω이었으며, 이는 가설울타리가 접지전극으로 활용될 수 있음을 의미한다. 그러나, 가설울타리를 특별고압설비나 피뢰설비 등의 접지전극으로 활용할 때 가설울타리에 접지전류가 흐르게 되면 전위가 상승하고 접촉전압이나 보폭전압 등으로 인하여 감전사고가 발생할 수 있으므로, 가설울타리를 접지전극으로 활용하는 때는 신중해야 한다. 감전이나 화재 등의 위험이 없도록 안전조치를 한 상태에서 가설울타리를 접지전극으로 제한적으로 활용해야 할 것이다.

  • PDF

A Study on the Characteristics of an Arc-Inducing Driven Rod with Needles (아크유도형 침부 접지봉의 특성 연구)

  • 박중신;정종욱;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.118-123
    • /
    • 2000
  • This paper describes the characteristics of a newly suggested arc-inducing driven rod with needles which could effectively spread out both the failure current with power frequency and the lightning current. The structural characteristic of the driven rod was that needles were attached on the surface of the conventional shaped driven rod and the driven rod with needles was installed inside of a copper pipe.As a result of analyzing the characteristics of this suggested driven rod when it was employed as the driven rod of an arrester in distribution system, it was verified that the primary voltage of the arrester was reduced by effectively exhausting the electrical energy since the arc occurred between the needle and the copper pipe.

  • PDF