• Title/Summary/Keyword: 접면조사

Search Result 6, Processing Time 0.021 seconds

Correction Method on Mismatched Posterior Edge of Medial and Lateral Tangential Fields for Three Fields Techniques in Breast Cancer (유방암 환자의 삼문 조사 시 내외측 접면 조사야의 Posterior Edge의 어긋남의 교정)

  • Kim Hun-Jung;Loh John JK;Kim Woo-Cheol;Park Sung-Young
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.174-181
    • /
    • 2003
  • Purpose: The target volume for the three field technique in breast cancer include the breast tangential and supraclavicular areas. The techniques rotating the gantry and couch angles, to match these two areas, will geometrically produce mismatching of the posterior edge between the medial and lateral tangential beams. This mismatch was confirmed by film dosimetry and three-dimensional computer planning. The correction methods of this mismatching were studied in this article. Materials and Methods: After the supraclavicular field was simulated using a half beam block and the medial and lateral tangential fields, by the rotation of the couch and gantry, we compared the following two methods to correct the mismatch. The first method was the rotation of coillmator until a line drawn on the posterior edge of tangential beams before the rotation of couch aligned the line drawn on the posterior edge after the rotation. The second method was the rotation of collimator according to the formula developed by the author as follows; Co=$2sin^{-1}${$sin\{theta}\{cdot}sin(C/2)$} (Co: collimator angle, $\theta$: angle between tangential beam and table, C: couch angle) Results: The film dosimetry showed the mismatching of posterior edges of the medial and lateral tangential fields prior to the rotation of collimator, while the posterior edges matched well after the rotation of collimator according to the formula. The three-dimensional computer plan also showed that the posterior edges matched well after the rotation of collimator accordingly. The DVH of the ipsilateral lung with the proper rotation of collimator angle was better than that without the rotation of collimator angle. Conclusion: The mismatching of the posterior edges of the medial and lateral tangential fields can be recognized on the three fileld technique in breast irradiation when the gantry and couch are simultaneously rotated and can be corrected with the proper rotation of the collimator angle. The radiation dose to the ipsilateral lung could be lowered with this technique.

Contralateral Breast Dose Reduction Using a Virtual Wedge (가상쐐기를 이용한 반대측 유방선량감소)

  • Yeo, In-Hwan;Kim, Dae-Yong;Kim, Tae-Hyun;Shin, Kyung-Hwan;Chie, Eui-Kyu;Park, Won;Lim, Do-Hoon;Huh, Seung-Jae;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.230-235
    • /
    • 2005
  • Purpose: To evaluate the contralateral breast dose using a virtual wedge compared with that using a Physical wedge and an open beam in a Siemens linear accelerator. Materials and Methods: The contralateral breast dose was measured using diodes placed on a humanoid phantom. Diodes were placed at 5.5 cm (position 1), 9.5 cm (position 2), and 14 cm (position 3) along the medial-lateral line from the medial edge of the treatment field. A 6-MV photon beam was used with tangential irradiation technique at 50 and 230 degrees of gantry angle. Asymmetrically collimated $17{\times}10cm$ field was used. for the first set of experiment, four treatment set-ups were used, which were an open medial beam with a 30-degree wedged lateral beam (physical and virtual wedges, respectively) and a 15-degree wedged medial beam with a 15-degree wedged lateral beam (physical and virtual wedges, respectively). The second set of experiment consists of setting with medial beam without wedge, a 15-degree wedge, and a 50-degree wedge (physical and virtual wedges, respectively). Identical monitor units were delivered. Each set of experiment was repeated for three times. Results: In the first set of experiment, the contralateral breast dose was the highest at the position 1 and decreased in order of the position 2 and 3. The contralateral breast dose was reduced with open beam on the medial side ($2.70{\pm}1.46%$) compared to medial beam with a wedge (both physical and virtual) ($3.25{\pm}1.59%$). The differences were larger with a physical wedge ($0.99{\pm}0.18%$) than a virtual wedge ($0.10{\pm}0.01%$) at all positions. The use of a virtual wedge reduced the contralateral breast dose by 0.12% to 1.20% of the proscribed dose compared to a physical wedge with same technique. In the second experiment, the contralateral breast dose decreased in order of the open beam, the virtual wedge, and the physical wedge at the position 1, and it decreased in order of a physical wedge, an open beam, and a virtual wedge at the position 2 and 3. Conclusion: The virtual wedge equipped in a Siemens linear accelerator was found to be useful in reducing dose to the contralateral breast. Our additional finding was that the surface dose distribution from the Siemens accelerator was different from a Varian accelerator.

ROC Analysis of Acid Demineralized Artificial Caries (인공치아 우식병소 진단의 ROC 분석)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.7-13
    • /
    • 1997
  • 조직학적으로 유용성이 입증된 산탈회법을 이용한 인접면 비교적 초기 치아 우식의 병소를 형성하여 진단율을 조사하였다. 산 용액을 이용하여 20개 인접면 치아우식을 20개 소구치에 형성하였고, 37개 인접면 치아우식을 30개 대구치에 형성하였다. 건전한 소구치 20개, 대구치 30개를 포함하여 총 96개 치아를 4개씩 나누어 24개의 블록을 형성하였고, 각각 2개 블록의 교합면을 교합시켜서, 교익촬영을 하였다. 촬영 결과를 36명의 치과의사들이인접면 치아우식의 유무를 기록하고, 동시에 및 ROC 분석을 위한 5 개 범주의 판독 기준으로 판독하여 기록하였다. 인접면 치아우식증 유, 무만으로 판독한 결과 진단의 sensitivity는 0.71, specificity는 0.78 이였다. ROC 분석 한 결과의 곡선도표 아래부분의 평균 면적은 약 0.806 이였다. 치아우식증 유무만으로 진단한 결과는 특정한 sensitivity와 specificity 만을 나타내지만, ROC 분석 결과는 주관적 진단 기준과 구별되는 고유의 진단 능력을 표시하는 1-specificity(False Positive)의 변화에 따른 sensitivity(True Positive)의 변화를 연속적으로 나타내어 주었다.

  • PDF

A study on the Auto-extraction of Land Characterictics Using a GSIS (GSIS를 이용한 토지 특성의 자동추출에 관한 연구)

  • Park, Sung-Kyu;Lim, Seoung-Hyeon;Park, Jung-Nam;Cho, Gi-Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.2 s.12
    • /
    • pp.59-67
    • /
    • 1998
  • This study deals with a auto-extraction of land characteristics using a GSIS. Major algorithm and a evaluation program was developed to automate the entire Process of land characteristics survey Through the automatic extraction of land information. To establish such a process, a method was provided to automatically extract detailed land information such as the shape, height, direction, road contact conditions, which could not be available in previous studies. The results showed that the adoption of such a automated process could lead the whole works related to the official land-value evaluation and securing residential complex to be more efficient and cost-saving in a scientific way comparing with existing process.

  • PDF

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

Factors Affecting the Appropriateness of Forest Land Transaction Price and Officially Assessed Land Price in Six Districts in Southern and Northern Parts of Han River in Seoul (서울시 강남·강북권 6개구(區) 임야 거래가격과 공시지가 적정성에 영향을 미치는 요인)

  • Kim, Hak Joon;Yoo, Joo Yoen
    • Korea Real Estate Review
    • /
    • v.28 no.4
    • /
    • pp.63-73
    • /
    • 2018
  • The purpose of this study is to identify the key factors affecting official land values and the appropriateness of the assessed land price, to find out what determines the real estate price and to assess the appropriateness of the valuation. This study explored whether actual transaction prices of forest land located in six Gu districts in southern and northern parts of Han river are appropriate using independent sample t-analysis and logistic regression analysis. Results showed that regional differences and shape were adequate for development restriction areas, whether biotope was designated, whether or not to be preserved, differences in pitch, and differences in use, and differences in bearing and approach. Thorough analysis of unique factors that determine forest land prices must be carried out in advance and the findings should be applied to the examination and assessment of official land values. The forest land appraisal system is closely related to the public's economic activity, thus it is necessary to apply forest land value determinants considered to be significant by market participants to the forestland appraisal system. I look forward to seeing variables related to the appropriateness of forest land transactions drawn from this study being used as indices for settlement of forest land transaction orders and market stabilization.