• Title/Summary/Keyword: 전해질 분석

Search Result 435, Processing Time 0.033 seconds

Fabrication of Small SOFC Stack Based on Anode-Supported Unit Cells and Its Power Generating Characteristics (음극지지형 단전지를 사용한 소형 SOFC 스택의 제조 및 출력특성)

  • Jung, Hwa-Young;Kim, Woo-Sik;Choi, Sun-Hee;Kim, Joosun;Lee, Hae-Weon;Ko, Haengjin;Lee, Ki-Chun;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.777-782
    • /
    • 2004
  • In this research, $5\times5cm^2$ unit cells were fabricated via liquid condensation process and uniaxial pressing followed by the screen printing of electrolyte and cathode layer. The SOFC stack was assembled with unit cells, gasket-type sealant and metal interconnect. The stack was designed to have a single column with internal-manifold and cross-flow type gas-channels. The SOFC stack produced 15 W, which is $50\%$ of the maximum power being expected from the maximum power density of the unit cell. Controlling factors for the proper operation of the SOFC stack and other designing factors of stack manifold and gas channels were discussed.

The clinical manifestations, the short- and long-term outcomes of Bartter syndrome (Bartter 증후군의 임상 양상과 장단기 치료 결과)

  • Park, Hye Won;Lee, Joo Hoon;Park, Young Seo
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.12
    • /
    • pp.1231-1240
    • /
    • 2007
  • Purpose : Bartter syndrome is a renal tubular defect in electrolyte transport characterized by hypokalemia, metabolic alkalosis and other clinical signs and symptoms. The aims of this study were to analyze the clinical manifestations and the short- and long-term outcomes of Bartter syndrome. Methods : We retrospectively reviewed clinical history, laboratory finding of blood and urine, renal ultrasonography, and hearing tests of five patients who were diagnosed and managed with Bartter syndrome at Asan Medical Center from April 1992 to May 2007. We also evaluated height and body weight periodically after institution of therapy. Results : All patients had poor oral intake, failure to thrive and polyuria. Three of them had maternal history of polyhydramnios and premature delivery. The mean age at diagnosis was 11.8 months. All children presented with hypokalemia, metabolic alkalosis, hyperreninemia. Their blood pressures were normal. One patient had nephrocalcinosis on renal ultrasonography and all of them had normal result in hearing tests. After treatment with indomethacin or other prostaglandin inhibitors and potassium supplementation,their clinical features improved with catch-up growth and improvement in the development during long-term follow-up. Conclusion : We emphasize that early diagnosis and proper treatment in patient with Bartter syndrome are related to better prognosis.

Electrocatalytic alcohol oxidation on Pt/ATO nanoparticle (ATO nanoparticle에 담지된 백금 촉매의 전기화학적 알콜 산화 반응에 관한 연구)

  • Lee, Kug-Seung;Park, In-Su;Jung, Dae-Sik;Park, Hee-Young;Sung, Yung-Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.463-466
    • /
    • 2006
  • 직접 알콜 연료전지는 액체인 알콜을 직접 연료전지에 공급하여 연소시킴으로써 높은 효율을 갖는 휴대용전원으로 주목받는 장치이다. 직접 알콜 연료전지에 담지체로 사용되는 탄소 소재는 넓은 표면적과 우수한 전기전도도를 가지고 있다는 장점 있으나 금속 촉매와의 상호작용이 약하여 촉매 활성에 영향을 주지 못한다. 산화물을 담지체로 사용할 경우 이러한 금속-담지체 간의 상호작용으로 인한 촉매활성 증가 및 입자성장 억제의 효과를 기대할 수 있다. 본 연구에서는, 안티몬 도핑된 주석산화물 (Sb-doped SnO2 : ATO nanoparticle)을 직접 메탄올 연료전지용 담지체어 적용하였으며 합성 과정은 다음과 같다. SnC14 5H2O SbC13, NaOH, HCl 수용액 혼합물을 삼구 플라스크에 넣고 $100^{\circ}C$ 온도에서 환류(reflux) 시킨 후 세척 및 건조하여 Air 분위기에서 열처리하였다. 합성된 산화물 수용액에 폴리올 방법으로 합성된 백금 콜로이드를 담지하였으며, 세척과 건조를 통하여 산화물에 담지된 백금 촉매를 촉매를 합성하였다. 촉매의 구조분석을 위해 XRD, TEM을 사용하였으며, 전극촉매로서의 활성을 평가하기 위해 cyclic voltammetry을 평가하였다. 본 연구에서는 백금의 담지량에 따른 Costripping voltammetry특성과 메탄올 및 에탄올 산화 반응 특성에 대하여, 탄소를 담지체로 사용한 Pt/C 촉매와 비교 평가하였다. 알콜 산화반응 평가결과, 주석산화물에 담지한 촉매가 탄소를 담지체로 사용한 촉매보다 우수한 활성을 나타내었으며 활성증가는 메탄올에 비해 에탄올 산화 반응의 경우 크게 증가하였다. 막과 비교해 보았다. $ZrO_2$ 입자는 전도성이며 동시에 친수성을 나타내기 때문에 상용 막에 비하여 함수율 및 수소이온 전도도가 우수하게 나타났다. 복합막의 이러한 물성은 $100^{\circ}C$이상의 고온에서 전해질 막 내의 물 관리를 용이하게 한다. 단위 전지 운전 온도 $130^{\circ}C$, 상대습도 37%의 운전 조건에서도 상당히 우수한 전지 성능을 보임에 따라 고온/저가습 조건에서 상용 Nafion 112 막보다 우수한 막 특성을 나타냄을 확인하였다.소/배후방사능비는 각각 $2.18{\pm}0.03,\;2.56{\pm}0.11,\;3.08{\pm}0.18,\;3.77{\pm}0.17,\;4.70{\pm}0.45$ 그리고 $5.59{\pm}0.40$이었고, $^{67}Ga$-citrate의 경우 2시간, 24시간, 48시간에 $3.06{\pm}0.84,\;4.12{\pm}0.54\;4.55{\pm}0.74 $이었다. 결론 : Transferrin에 $^{99m}Tc$을 이용한 방사성표지가 성공적으로 이루어졌고, $^{99m}Tc$-transferrin의 표지효율은 8시간까지 95% 이상의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{99m}Tc$<

  • PDF

Study on Hydrogen Embrittlement for API 5L X65 Steel Using Small Punch Test II : Weld Metal (소형펀치 시험을 이용한 API 5L X65 강의 수소취화에 관한 연구 II : 용접부)

  • Jang, Sang-Yup;Yoon, Kee-Bong
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.56-62
    • /
    • 2009
  • With weld metal of X65 steel, hydrogen was charged by electro-chemical method and mechanical behavior such as strength was measured by the small punch test. The weld metal was more sensitive to hydrogen charging than the case of base metal. The small punch (SP) strength was decreased as the hydrogen contents increased. Magnitude of strength decrease was dependent on current density, temperature, charging time. Current density and charging time have significant effect on the mechanical properties but temperature of electrolyte has limited effect. Fractured surfaces of the tested specimens were observed by SEM (scanning electron microscope). In the hydrogen charged specimens cleavage fracture were observed, which is consistent with the SP test results. Since the testing procedure for studying hydrogen embrittlement proposed in this study has shown good reproducibility of test results, the proposed method can be assumed to be a reliable test procedure. Using the electrochemical charging and the small punch test, the change of SP strength for X65 weld metal due to hydrogen embritlement could be evaluated sensitively.

Electrochemical Degradation of Phenol by Using Reticulated Vitreous Carbon Immobilized Horseradish Peroxidase (Horseradish Peroxidase가 고정화된 다공성 탄소 전극을 이용한 페놀의 전기화학적 분해)

  • Cho, Seung-Hee;Yeon, Kyeong-Ho;Kim, Gha-Young;Shim, Joon-Mok;Moon, Seung-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1263-1269
    • /
    • 2005
  • Horseradish peroxidase, had the phenol degradation rate of 95% in aqueous phase, was covalently immobilized on the surface of reticulated vitreous carbon(RVC) and the degradation of phenol was performed with in situ generated $H_2O_2$-immobilized HRP complex in an electrochemical reactor. The incorporation of carboxylic group on the RVC surface was confirmed by FT/IR spectrometry and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride(EDC) was used for peptide bonds between the carboxylic groups on the RVC surface and amine groups from HRP. The optimal conditions of in situ $H_2O_2$ generation such as concentration($10{\sim}200$ mM) and pH($5.0{\sim}8.0$) of electrolyte, supply of $O_2(10{\sim}50$ mL/min) and applied voltage($-0.2{\sim}-0.8$ volt, vs. Ag/AgCl) from potentiostat/galvanostat were determined by concentration of hydrogen peroxide and current efficiency. It was observed that the RVC immobilized HRP was stable maintaining 89% of the initial activity during 4 weeks. The phenol degradation rate of 86% was attained under the optimal condition of in situ $H_2O_2$ generation.

Preparation and Characterization of PVA/PAM Electrolyte Membranes Containing Silica Compounds for Direct Methanol Fuel Cell Application (실리카 화합물을 함유한 PVA/PAM 전해질 막의 제조 및 특성과 직접메탄올 연료전지로의 응용)

  • Yoon, Seok-Won;Kim, Dae-Hoon;Lee, Byung-Seong;Lee, Bo-Sung;Moon, Go-Young;Byun, Hong-Sik;Rhim, Ji-Won
    • Polymer(Korea)
    • /
    • v.34 no.1
    • /
    • pp.45-51
    • /
    • 2010
  • This study focuses on the investigation of the possibility of the crosslinked poly (vinyl alcohol) membranes with both poly (acrylic acid-co-maleic acid) (PAM) and 3-(trihydroxysilyl)-1-propane-sulfonic acid (THS-PSA) for the direct methanol fuel cell application. In order to characterize the prepared membranes, the water content, the thermal gravimetric analysis, the ion exchange capacity, the ion conductivity and the methanol permeability measurements were carried out and then compared with the existing Nafion 115 membrane. The ion exchange capacity of the resulting membranes showed 1.6~1.8 meq./g membrane which was improved than Nafion 115, 0.91 meq./g membrane. In the case of the proton conductivity, the THS-PSA introduced membranes gave more excellent $0.042{\sim}0.056\;S{\cdot}cm^{-1}$ than Nafion 115, $0.024\;S{\cdot}cm^{-1}$. On the other hand, the methanol permeability was increased more than Nafion 115 for all the range of THA-PSA concentration.

Peritoneal Dialysis in Dogs: 20 cases (2006-2008) (개에서 복막투석 적용: 20 증례 (2006-2008))

  • Nam, So-Jeong;Choi, Ran;Oh, Won-Seok;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Peritoneal dialysis (PD) is a clinical technique that therapeutically removes toxic solutes from body fluids and normalizes endogenous solutes whose aberrant concentrations disrupt normal physiology. This study retrospectively evaluated clinical outcomes and complications of PD in 20 dogs with renal failure. Blood works (total count of red blood cells (RBC), packed cell volume (PCV), the serum biochemical, and electrolyte values related to renal insufficiency) and complications associated with peritoneal dialysis, and clinical outcomes were recorded before and after PD. Additionally, creatinine reduction ratio (CRR) and urea nitrogen reduction ratio (URR) were calculated for evaluating the efficacy of PD. PD resulted in a significant (p < 0.05) reduction in blood urea nitrogen (BUN) concentration in 19 dogs, while a significant (p < 0.05) reduction in creatinine concentration in 17 dogs. The complications of PD were hypoalbuminemia (12/20, 60%), anemia (10/20, 50%), subcutaneous dialysate leakage (9/20, 45%), bacterial peritonitis (6/20, 30%), dialysate retention (5/20, 25%) and limb edema (4/20, 20%). This study demonstrated that PD was effective in reducing the magnitude of azotemia in dogs with renal failure especially in acute phase, although the complication rate was high but manageable.

Structural and electrochemical characterization of K2NiF4 type layered perovskite as cathode for SOFCs (K2NiF4 type 층상 페롭스카이트 구조 La(Ca)2Ni(Cu)O4-δ의 SOFC 양극 특성 및 결정구조 평가)

  • Myung, Jae-ha;Hong, Youn-Woo;Lee, Mi Jai;Jeon, Dae-Woo;Lee, Young-Jin;Hwang, Jonghee;Shin, Tae Ho;Paik, Jong Hoo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.3
    • /
    • pp.116-120
    • /
    • 2015
  • $La_2NiO_{4+{\delta}}$ based oxides, a mixed electronic-ionic conductors (MIECs) with $K_2NiF_4$ type structure, have been considerably investigated in recent decades as electrode materials for advanced solid oxide fuel cells (SOFCs) due to their high electrical conductivity, and oxidation reduction reaction (ORR). In this study, structure properties of $La(Ca)_2Ni(Cu)O_{4+{\delta}}$ were studied as a potential cathode for intermediate temperature SOFCs (IT-SOFCs).

Electrostatic Formation of Chitosan-Polyacrylate Polyplex for the Preparation of Cross-Linked Hydrogel Particles (이온성 상호작용을 통한 키토산-폴리아크릴산 Polyplex의 형성 및 이를 이용한 하이드로젤 특성 분석)

  • Kim, Yeojin;Kwon, Ji-Yeong;Lee, Sang-Min
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.1
    • /
    • pp.24-29
    • /
    • 2018
  • Despite the great potential for the versatile applications in food industry and medical area, chitosan as a biocompatible cationic polysaccharide has suffered from the limited solubility under physiological condition. Herein, we demonstrated the electrostatic formation of chitosan-based polyplex particles, counterbalanced by polyacrylate as an anionic polyelectrolyte. The resulting polyplex exhibited pH- and composition-dependent changes in their surface charges as measured by zeta potential, which can be employed to provide the interparticle repulsive forces for enhanced colloidal stability in homogeneous solution. Subsequently, amide coupling between the acrylates and glucosamine residues of chitosan inside the polyplex further generated the hydrogel particles, which showed the temperature-sensitive swelling property. This aspect can be attributed to the partial formation of acryl amide residues, which have been generally known to possess the lower critical solution temperature (LCST).

Electrochemical Performance on the H3BO3 Treated Soft Carbon modified from PFO as Anode Material (음극소재로 PFO에서 개질된 붕산처리 소프트 카본의 전기화학적 성능)

  • Lee, Ho Yong;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.746-752
    • /
    • 2016
  • In this study, soft carbon was prepared by carbonization of carbon precursor (pitch) obtained from PFO (pyrolysis fuel oil) heat treatment. Three carbon precursors prepared by the thermal reaction were 3903 (at $390^{\circ}C$ for 3 h), 4001 (at $400^{\circ}C$ for 1 h) and 4002 (at $400^{\circ}C$ for 2 h). After the prepared soft carbon was ground to a particle size of $25{\sim}35^{\circ}C$, the soft carbon was synthesised by the chemical treatment with boric acid ($H_3BO_3$). The prepared soft carbon were analysed by XRD, FE-SEM and XPS. Also, the electrochemical performances of soft carbon were investigated by constant current charge/discharge test, cyclic voltammetry and impedance tests in the electrolyte of $LiPF_6$ dissolved inorganic solvents (EC:DMC=1:1 vol%+VC 3 wt%). The coin cell using soft carbon of $25{\sim}35^{\circ}C$ with 3903 soft carbon ($H_3BO_3$/Pitch=3:100 in weight) has better initial capacity and efficiency (330 mAh/g, 82%) than those of other coin cells. Also, it was found that the retention rate capability of 2C/0.1C was 90% after 30 cycles.