• Title/Summary/Keyword: 전하중

Search Result 421, Processing Time 0.032 seconds

Effect of Force-field Types on the Proton Diffusivity Calculation in Molecular Dynamics (MD) Simulation (분자동역학 전산모사에서 force-field의 종류가 수소이온 확산도 계산에 미치는 영향)

  • Lee, Ji Hyun;Park, Chi Hoon
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.358-366
    • /
    • 2017
  • The most important factor in the performances of polymer electrolyte membranes for fuel cells is how fast hydrogen ions can be transported along the water channel formed inside the electrolyte membrane. Since the morphology of the water channel and the diffusivity of the protons are very important factors for the proton transport behavior, various molecular dynamics simulation studies are being carried out to clarify this. The force-field is an important variable parameterizing the movement and interaction of each atom in molecular dynamics simulation. In this study, proton diffusivities of the 3D models of polymer electrolyte membranes were calculated in order to analyze the effects of various types of force-fields on the molecular simulation. It has been found that the charge value determining the non-bonding interaction plays a very important role in the formation of the water channel morphology, and the COMPASS force-field can calculate the accurate proton diffusion behavior. Accordingly, for molecular dynamics simulation of polymer electrolyte membranes, the proper selection of the force-field is very important due to its great effect on the proton diffusion as well as the final molecular structure.

A Semilongitudinal Study on Cranial Base, Maxillary and Mandibular Growth of Korean Children Aging 7 to 17 Years Old (한국인 7-17세 아동의 두개저, 상악, 하악의 성장에 관한 준종단적 연구)

  • Sohn, Byung-Wha;Kim, Hyung-Soon
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.23-35
    • /
    • 1999
  • Lateral cephalograms or 251 males md 286 females were taken and pubertal growth pattern or cranial base, maxillary and mandible of 7 to 17 years old Korean children was evaluated. 10 landmarks and 16 analytical measurements were evaluated. Analytical measurement and annual difference for each age group was calculated and tested for statistical significance. Analytical measurements were classified into three groups which were cranial base, maxillary and mandibular measurements and also classified into make and female measurements. Following results were achieved. 1. The circumpuberal growth spurt was earlier in Korean females than in males. 2. Cranial base, maxilla and mandible showed circumpuberal growth. The cranial base showed a relatively smaller amount of growth than the facial complex. 3. Middle and posterior cranial base length showed a floater increase than anterior cranial base length and circumpuberal growth spurt was also more definite. 4. the forward and downward growth or maxilla results from maxillary growht itself and transposition or the maxilla due to circumsutural growth aroud the maxilla. Ar-ANS and Ar-Pr which represent maxillary position relative to the cranial base showed more growth than ANS-PNS which represents maxillary bone growth. 5. mandible showed more vertical growth than horizontal growth but without significance. 6. Alveolar gwoth of maxilla and mandible show maximum growth rate of the time of permanent teeth eruption following loss of deciduous teeth . After this period alveolar growth shows a decreasing tendency.

  • PDF

Impedance Parameters of Electrical Double Layer I. A Determination Method of Electrolytic Cell Impedance Parameter on the Platinum Electrode (전기이중층의 임피던스 파라미터 I. 백금전극을 사용한 전해쎌 임피던스 파라미터의 결정방법)

  • Kum-Sho Hwang;Un-Sik Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.273-281
    • /
    • 1986
  • This study is focused on the correct measurement of the equations for the determination of the impedance parameters-the differential capacity of the double layer $C_d$, solution resistance $R_Q$, transfer resitance $R_i$, and adsorption pseudcapacity $C_{\phi}$/ The application of only an imaginary part of complex function of ${\omega}$ at the sinusoidal steady state indicates the following equations of total impedance: at low frequency $|Z_{LF}|=1/{\omega}_1\;C_{\phi}\;{\sqrt{1+{{\omega}_1}^2/{\omega}^2}$, at high frequency $|Z_{HF}|={\omega}_2/({\omega}_1{\omega}_3C{\phi})({\omega}^2+{{\omega}_2}^2)\;{\sqrt{{({\omega}^2+{\omega}_2{\omega}_3)}^2+{({\omega}_2{\omega}-{\omega_3{\omega})^2}}$. The values of the total impedance of cell, phase angle, and cell current that are necessary for the calculations of impedance parameters were experimentally measured from 200 to 6000Hz for the following supporting electrolytes, 0.5M $Na_2SO_4$, 1M NaCl, 19.373% sea water, 1M HCl, 1M $KNO_3$ and for $10^{-2}M$ KI and 60mM DBNA (Di-iso-Butylnitrosoamine) in these supporting electrolytes. The derived equations in this study shows that the values of impedance parameters of $C_d,\;C_{\phi},\;R_i\;and\;R_Q\;are\;15{\sim}40\;{\mu}F/cm^2,\;162{\sim}758\;{\mu}F/cm^2\;11.5{\sim}57.6\;ohm{\cdot}cm^2\;and\;0.5{\times}10^{-2}{\sim}4.1{\times}10^{-2}\;ohm{\cdot}cm^2$ respectively.

  • PDF

A STUDY OF THE CHARACTERISTICS OF CRANIOFACIAL SKELETON ON ORTHOGNATHIC SURGICAL GASES WITH SKELETAL GLASS III MALOGGLUSION (악교정술을 요하는 골격성 III급 부정교합자의 악안면 골격 특성에 관한 연구)

  • Lim, Han-Ho;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.189-201
    • /
    • 1998
  • The purpose of this study was to evaluate the characteristics of craniofacial skeleton on orthognathic surgical cases with skeletal Class III malocclusion. For this study, 74 students at the dental college of Chosun University volunteered as a normal occlusion group. They had well-balanced faces and good occlusions with acceptable Class I molar relationship. They had not received orthodontic treatment and had no signs or symptoms of temporomandibular joint dysfunction. 45 malocclusion patients enrolled for orthognathic surgical treatment with skeletal Class III malocclusion at the Department of Orthodontics, College of Dentistry, Chosun University. On the basis of this study. the results of this study were as follows: 1. Skeletal Class III malocclusion was largely due to the overgrowth of mandible in man and the undergrowth of maxilla in woman. 2. The mandible was antero-inferiorly overgrown by large MP-HP angle and large genial angle in orthognathic surgical cases with skeletal Class III malocclusion. And also, upper incisors were severely labioversioned, but on the other hand lower incisors were linguoversioned. 3. In female, lower-third facial height was characteristically shortened in comparison with middle-third facial height and also, lower facial throat angle was small in male.

  • PDF

Analysis of Channel Doping Profile Dependent Threshold Voltage Characteristics for Double Gate MOSFET (이중게이트 MOSFET의 채널도핑분포의 형태에 따른 문턱전압특성분석)

  • Jung, Hak-Kee;Han, Ji-Hyung;Lee, Jae-Hyung;Jeong, Dong-Soo;Lee, Jong-In;Kwon, Oh-Shin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.664-667
    • /
    • 2011
  • In this paper, threshold voltage characteristics have been analyzed as one of short channel effects occurred in double gate(DG)MOSFET to be next-generation devices. The Gaussian function to be nearly experimental distribution has been used as carrier distribution to solve Poisson's equation, and threshold voltage has been investigated according to projected range and standard projected deviation, variables of Gaussian function. The analytical potential distribution model has been derived from Poisson's equation, and threshold voltage has been obtained from this model. Since threshold voltage has been defined as gate voltage when surface potential is twice of Fermi potential, threshold voltage has been derived from analytical model of surface potential. Those results of this potential model are compared with those of numerical simulation to verify this model. As a result, since potential model presented in this paper is good agreement with numerical model, the threshold voltage characteristics have been considered according to the doping profile of DGMOSFET.

  • PDF

The Immediate and Long Term Result of Surgical Angioplasty of Left Main and Proximal Left Anterior Decending Coronary Artery (좌주관상동맥 및 좌전하행지기시부의 수술적 혈관 성형술의 중장기 성적)

  • 안현성;김응중;신윤철;지현근;이원용
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.692-697
    • /
    • 2001
  • Background: The left main coronary artery surgical angioplasty has become the choice of surgical procedure in isolated LM disease. We have performed 22 cases of LMCA surgical angioplasy since 1996. We report the immediate and long term result of the surgical angioplasty with their postoperative angiography. Material and Method: Between July 1994 and October 2000, 22 patients(11 men and 11 women) were subjected to surgical patch angioplasty of the LMCA, 1 patient had an additional angioplasty performed on the proximal right coronary artery. The LMCA was approached anteriorly with or without transection of the main pulmonary artery(21 cases), and in a patient who had undergone an aortic valve replacement, LMCA was approached superiorly with transection of the ascending aorta. Additional grafting was required in 5 cases. The on-lay patch was used with autologous pericardium in 6 cases and bovine pericardium in 16 cases. Result: There was no operative mortality. There was 30~50% stenosis of the anastomosis site in 3 cases at the postop. coronary angiography. Coronary angiography was reperformed in 5 cases between 5th months and 15th months postoperatively. There was 40~60% stenosis of the anastomosis site in 2 cases. There was one death at 42nd months postoperatively but the cause was unknown. No patient complained of angina with a mean follow up of 48.$\pm$22.5 months. Conclusion: There were only several coronary angiographic results in long term follow-up but we had relatively good clinical results for LMCA surgical angioplasty in the immediate and long term. The excellence of LMCA surgical angioplasty needs the result of the long term follow-up.

  • PDF

The Citizen Science Stories in Korea: 1982~2018 (한국의 시민과학이 전하는 메시지: 1982~2018)

  • Kim, Ji Yeon
    • Journal of Science and Technology Studies
    • /
    • v.18 no.2
    • /
    • pp.43-93
    • /
    • 2018
  • The concept of citizen science(CS) is defined as "scientific work carried out by citizens." Here, 'citizen' means someone who has knowledge of everyday life, regardless of whether they have formal expertise in a related field. This definition may encompass scientists, as many scientists participate in scientific democracy and use their expertise in a citizen-oriented manner. That work is derived from their citizenship, so their scientific work is CS. CS in Korea has expanded from the Korea Pollution Research Institute, which was founded in 1982, to the Center for Democracy in Science & Technology, which was founded in 1997. Furthermore, in recent years, government agencies have started using CS approach. In this paper, I introduce Korean CS and examine its accomplishments and difficulties through eight cases. I show that Korea's CS activities have made a significant impact on Korean society and the experience of these activities has implications for the future directions of CS. I do so by examining four modes of CS and explore practical messages for more varied roles of CS. Until now CS has been mainly considered in the context of "CS as education" or "CS as movement" in Korea. However, governance and the platform mode of social decision-making or research, though still rare, have recently emerged as additional CS activities. Although it cannot be said with certainty that CS is better, it is undoubtedly better the more varieties of its modes coexist. The four types of CS will contribute individually or complementarily to social learning. Thus, because of its distinctive potential, CS is not exhausted by the supplementary concept of science.

InSb 적외선 감지 소자용 $Si_3N_4$, $SiO_2$ 절연막 계면 특성 연구

  • Park, Se-Hun;Lee, Jae-Yeol;Kim, Jeong-Seop;Kim, Su-Jin;Seok, Cheol-Gyun;Yang, Chang-Jae;Park, Jin-Seop;Yun, Ui-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.163-163
    • /
    • 2010
  • 중적외선 영역 ($3{\sim}5\;{\mu}m$)은 공기 중에 존재하는 이산화탄소나 수증기에 의해 흡수가 일어나지 않기 때문에 군사적으로 중요한 파장 영역이며, 야간에 적을 탐지하는데 응용되고 있다. InSb는 77 K에서 중적외선 파장 흡수에 적합한 밴드갭 에너지 (0.228 eV)를 갖고 있으며, 다른 화합물 반도체와 달리 전하 수송자 이동도 (전자: $10^6\;cm^2/Vs$, 정공: $10^4\;cm^2/Vs$)가 매우 빠르기 때문에 적외선 화상 감지기 재료로 매우 적합하다. 또한 현재 중적외선 영역대에서 널리 사용되는 HgCdTe (MCT)와 대등한 소자 성능을 나타냄과 동시에 낮은 기판 가격, 소자의 제작 용이성 때문에 MCT를 대체할 물질로 주목 받고 있다. 하지만, 기판과 절연막의 계면에 존재하는 결함 때문에 에너지 밴드갭 내에 에너지 준위를 형성하여 높은 누설 전류 특성을 보인다. 따라서 InSb 적외선 소자의 구현을 위하여 고품질의 절연막의 연구가 필수적이라고 할 수 있겠다. 절연막의 특성을 알아보기 위해, n형 InSb 기판에 플라즈마 화학 기상 증착법 (PECVD)을 이용하여 $SiO_2$, $Si_3N_4$를 증착하였으며, 증착 온도를 $120^{\circ}C$에서 $240^{\circ}C$까지 $40^{\circ}C$ 간격으로 변화하여 증착온도가 미치는 영향에 대하여 알아보았다. 절연막과 기판의 계면 특성을 분석하기 위하여 77 K에서 커패시턴스-전압 (C-V) 분석을 하였으며, 계면 트랩 밀도는 Terman method를 이용하여 계산하였다 [1]. $Si_3N_4$를 증착하였을 경우, $120{\sim}240^{\circ}C$의 증착 온도에서 $2.4{\sim}4.9{\times}10^{12}\;cm^{-2}eV^{-1}$의 계면 트랩 밀도를 가졌으며, 증착 온도가 증가할수록 계면 트랩 밀도가 증가하는 경향을 보였다. 또한 모든 증착 온도에서 flat band voltage가 음의 전압으로 이동하였다. $SiO_2$의 경우 $120{\sim}200^{\circ}C$의 증착온도에서 $7.1{\sim}7.3{\times}10^{11}\;cm^{-2}eV^{-1}$의 계면 트랩 밀도 값을 보였으나, $240^{\circ}C$ 이상에서 계면 트랩밀도가 $12{\times}10^{11}\;cm^{-2}eV^{-1}$로 크게 증가하였다. $SiO_2$ 절연막을 사용함으로써, $Si_3N_4$ 대비 약 25% 정도 낮은 계면 트랩 밀도를 얻을 수 있었으며, 모든 증착 온도에서 양의 전압으로 flat band voltage가 이동하였다. 두 절연막에 대한 계면 트랩의 원인을 분석하기 위하여 XPS 측정을 진행하였으며, 깊이에 따른 조성 분석을 하였다. 본 실험에서 최적화된 $SiO_2$ 절연막을 이용하여 InSb 소자의 pn 접합 연구를 진행하였다. Be+ 이온 주입을 진행하고, 급속열처리(RTA) 공정을 통하여 p층을 형성하였다. -0.1 V에서 16 nA의 누설 전류 값을 보였으며, $2.6{\times}10^3\;{\Omega}\;cm^2$의 RoA (zero bias resistance area)를 얻을 수 있었다.

  • PDF

반도체 검출기의 절연 최적화를 위한 다층 절연막 평가

  • Park, Jeong-Eun;Myeong, Ju-Yeon;Kim, Dae-Guk;Kim, Jin-Seon;Sin, Jeong-Uk;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.372-372
    • /
    • 2014
  • 반도체 검출기는 입사되는 X선 에너지에 의하여 이온화되어 발생하는 전자 전공쌍을 수집함으로 방사선 정보를 확인하는 선량계로써 많은 연구와 활용이 이루어지고 있다. 하지만, X선 에너지에 의하여 반도체 검출기에서 발생하는 전기적 신호량이 높지 않기 때문에 누설 전류의 저감이 필수적이다. 누설 전류를 저감시키기 위한 방안으로 반도체 층과 전극 층의 Schottky Contact 구조의 설계, Insulating Layer의 사용, 높은 비저항의 반도체 물질 연구 등이 이루어지고 있다. 하지만, 기존에 누설 전류 저감을 위하여 Insulating Layer를 전극층과 반도체 층 사이에 형성하는 연구에 있어서 Insulating Layer와 반도체 층의 계면 사이에서 발생하는 Charge Trapping으로 인하여 생성되는 신호의 Reproducibility 저하, 동영상 적용의 제한 등의 문제점을 겪어왔다. 이에 본 논문에서는 누설 전류를 저감시킴과 동시에 Charge Trapping의 최소화를 이루기 위하여 Insulating Layer의 두께 최적화 연구를 수행하였다. 본 연구에서 사용한 Insulating Layer는 검출기 표면에 입사하는 X선 정보 손실을 최소화 시키는 동시에 누설 전류와 Charge Trapping을 최소화 시키는 방법으로써 CVD방법으로 검출기 표면에 균일하게 Insulating Layer를 코팅하였다. Insulating 물질은 Parylene을 사용하였으며, 그 중 온도, 습도 등 외부환경에 영향을 적게 받는 type C를 사용하였다. 증착에 사용한 장비의 진공도는 Torr로 설정하여 증착되는 Parylene의 두께가 약 $0.3{\mu}m$가 되게 하였으며, 실험에는 반도체 물질 PbO를 사용하였다. Parylene의 절연 특성은 Dark Current와 Sensitivity를 측정한 SNR을 이용하여 Parylene코팅이 되지 않은 동일 반도체 검출기와의 신호를 비교하였으며 또한 Parylene를 다층 제작한 검출기의 수집 신호량을 비교하였다. 제작한 검출기의 X선 조사 시의 수집 전하량 측정 결과, 100 kVp, 100mA, 0.03s의 X선 조건에서 $1V/{\mu}m$의 기준 시, Parylene를 코팅하지 않은 PbO 검출기의 Dark current는 0.0501 nA/cm2, Sensitivity는 0.6422 nC/mR-cm2, SNR은 12.184이었으며, Parylene단층의 두께인 $0.3{\mu}m$로 증착된 시편의 Dark current는 0.04097 nA/cm2, Sensitivity는 0.53732 nC/mR-cm2으로 Dark current가 감소되고 sensitivity도 감소하였지만 SNR은 13.1150으로 높아진 것을 확인할 수 있었다. Perylene이 $0.6{\mu}m$로 증착된 시편의 경우, Dark Current는 0.04064 nA/cm2, Sensitivity는 0.31473 nC/mR-cm2, SNR은 7.7443으로써 Insulating Layer가 없는 시편보다 SNR이 약 40% 낮아진 것을 확인할 수 있었다. Parylene이 $0.9{\mu}m$로 증착된 시편의 경우 Dark current는 0.0378 nA/cm2, Sensitivity 0.0461 nC/mR-cm2로 Insulating Layer가 없는 시편에 비해 SNR은 약 1/12배 감소한 1.2196이었고, Parylene이 $1.2{\mu}m$로 증착된 시편의 SNR은 1.1252로서 더 감소하였다. 따라서 Parylene을 다층 코팅한 검출기일수록 절연 효과의 영향이 커짐으로써 SNR 비교 시 수집되는 신호량이 줄어드는 것을 확인하였다. 반도체 검출기의 누설 전류를 저감시킴과 동시에 신호 수집율에 영향을 최소화시키기 위하여 Insulating Layer의 두께를 적절하게 설정하여 적용하면 Insulating Layer가 없는 검출기에 비해 누설전류를 최소한으로 줄일 수 있고 신호 검출효율이 감소하는 것을 방지할 수 있을 것이라 사료된다.

  • PDF

금 나노로드 어레이 박막을 이용한 광학형 바이오 센서 개발

  • Yeom, Se-Hyeok;Lee, Dong-Ik;Sin, Han-Jae;Seo, Chang-Taek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.436-436
    • /
    • 2014
  • 본 연구에서는 전 세계적으로 활발히 연구되고 있는 나노바이오센서 분야 중 가장 주목을 받고 있는 LSPR 원리를 이용한 바이오센서를 제작하였다. 금속 나노입자의 국소 표면 플라즈몬 공명현상에 의한 주위환경에 민감하게 반응하는 특성은 고감도 광학형 바이오센서, 화학물질 검출 센서등에 응용된다. 특히 금 나노막대와 같은 1차 나노구조물은 나노막대의 주변 환경 변화에 따라 뚜렷한 플라즈몬 흡수 밴드 변화를 나타냄으로 센서로 적용 했을 때 고감도의 측정이 가능하다. 본 연구에서는 다공성인 알루미늄 양극산화 박막 주형틀을 이용하여 다양한 종횡비를 가지는 금 나노막대를 합성하고, 나노막대 어레이 형태의 박막을 제작하였다. 금 나노막대의 합성은 알루미늄 양극산화막을 사용한 주형제조 방법(template method)을 사용하는 전기화학 증착법을 사용하였다. 우선 부도체인 알루미늄 양극 산화막의 한쪽면을 열증착 장비를 사용하여 금을 증착하여 작업 전극(working electrode)을 형성하였다. 백금 선(platinum wire)을 보조 전극(counter electrode)으로 사용하고 Ag/AgCl 전극을 기준 전극(reference electrode)으로 사용하여 삼전극계(three-electrode system)를 형성하였으며, 금 도금 용액(orotemp 24 gold plating solution, TECHNIC INC.)을 사용하여, 800 mV 전압에서 금 나노 막대를 합성하였다. 금 나노막대의 길이는 테플론 챔버를 통과한 전하량 또는 전기 증착 시간에 비례하여 결정된다. 금 나노막대를 성장시킨 알루미늄 양극산화막을 실리콘 웨이퍼에 은 페이스트를 사용하여 고정시킨 후 수산화나트륨 (NaOH)용액을 사용하여 알루미늄 양극산화막을 녹여내어 수직방향으로 정렬되어 있는 나노 막대 어레이 박막을 제조 하였다. 또한 제작된 금 나노막대 어레이의 광학적 특성을 평가하였다. 본 연구에서와 같이 나노막대를 직경방향으로 측정할 경우, 직경방향의 transverse mode만 측정된다. 금 나노 막대가 알루미늄 양극산화막 안에 포함된 상태로 측정된 금 나노로드 어레이 박막의 광 스펙트럼 분포는 금 나노막대의 가시광영역에서의 흡수 스펙트럼을 측정하였을시 직경 및 길이에 따라 transverse mode의 ${\lambda}$ max (최대 흡광)의 위치가 변화됨을 나타낸다. 실험 결과를 바탕으로 나노막대의 종횡비가 증가함에 따라 흡수 스펙트럼의 transverse mode ${\lambda}$ max가 미약하게 단파장 영역으로 이동하는 것을 확인할 수 있다. 이러한 결과는 원기둥 형태의 금 나노막대의 흡수 스펙트럼에 대한 이론적인 예측과 부합한다. 바이오센서로의 적용 가능성을 확인하기 위하여 자기조립단분자막을 형성하여 항체를 고정하고 CRP에 대한 응답특성을 평가하였다. CRP 항원-항체의 면역반응에 대한 실험 결과 CRP 항원의 농도가 증가함에 따라 넓은 측정범위에서 선형적으로 흡광도가 증가하는 결과를 나타내었으며, CRP 10 fg/ml의 농도까지 검출할 수 있었다. 센서의 선택성을 확인하기 위하여 감지하고자하는 대상물질이 아닌 Tn T 항원을 감지막에 반응시켜 흡광도 변화를 분석하였다. 결과적으로 제작된 센서칩은 선택성을 가지고 측정하고자하는 물질에만 반응함을 확인하였다. 이러한 결과는 다양한 직경을 사용한 부가적인 LSPR현상의 연구에 활용될 수 있을 것이다.

  • PDF