• Title/Summary/Keyword: 전자선 출력

Search Result 199, Processing Time 0.02 seconds

High Frequency High Voltage 40kW Power System for Diagnosis X-ray (진단 X-선용 40kW 고주파 고압 전원 시스템)

  • 김학성;박영국;오준용;성기봉
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.192-198
    • /
    • 2003
  • Recently, the Inverter type X-ray generator is rapidly replacing the conventional single-phase or three-phase X-ray generator, it has several merits of space-saving: high accuracy and reproducibility. This paper presents a 40kw(12kV, 80mA) high tension generator system for diagnosis X-ray. The control circuit and design consideration of the proposed high tension power supply are given. Issues in the design of high voltage isolating transformer are discussed. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. 1'he proposed apparatus has several advantages, e. g., the fast rising time of tube voltage, accuracy and reduced component size etc.

Novel Quadrature Branch-line Coupler Using CPW-to-Microstrip Transitions (마이크로스트립 전이를 이용하는 CPW Branch-line 커플러)

  • Lee, Jung-Ho;Lee, Hae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.5
    • /
    • pp.10-16
    • /
    • 2000
  • This paper presents new double-sided 3-dB branch-line coupler using CPW-to-Microstrip via-hole transitions for the multi-layer applications. The characteristic impedance is obtained using the even-odd mode method, and the circuit performance Is accurately estimated by the Finite Difference Time Domain(FDTD) method. The fabricated double-sided 3-dB branch-line coupler has less than 0.3 dB power dividing imbalance and 1。 phase imbalance, greater than 30 dB isolation, and 25 dB return loss over a 20% bandwidth centered at 2 GHz. Calculated and fabricated results show that this coupler provides better performance as compared to the conventional microstrip branch-line couplers.

  • PDF

Development of One-channel Gamma ray spectroscope for Automatic Radiopharmaceutical Synthesis System (방사성 의약품 자동합성장치용 단채널 감마선 분광기 보드의 설계 및 제작)

  • Song, Kwanhoon;Kim, Kwangsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.193-200
    • /
    • 2014
  • In this paper, the prototype of one-channel gamma-ray spectroscope for automatic radiopharmaceutical systhesis system was designed and characterized. The prototype employed CZT (CdZnTe) spear detector for gamma-ray detection and employed analog-type signal processing method. A radioactive sample Co-60 was used for measuring performance of the gamma-ray spectroscope and energy spectrum is gained with bandwidth of 1173keV. The analog board is made up of SF (shaping filter) and PHA (peak and hold amplifier) for shaping CZT output signal appropriately and ADC (analog to digital converter) and FPGA (field programmable gate array) for drawing gamma-ray spectrum by counting the digitalized gamma-ray signal data.

Determination of Inverter Circuit Parameters of Electronic Ballasts for Dimming Compact Fluorescent Lamps (콤팩트 형광램프용 Dimming형 전자식 안정기의 회로정수 결정)

  • Gwak, Jae Yeong;Song, Sang Bin;Yeo, In Seon
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.117-117
    • /
    • 1995
  • 본 논문에서는 콤팩트 형광램프용 Dimming형 전자식 안정기의 설계에 있어서, 인버터 공진탱크의 커패시턴스값을 변화시킬 때 전압이득곡선을 분석하여 최적의 회로정수를 결정하는 방법을 제안하였다. 또한 하프브리지 인버터회로의 회로정수에 대한 PSpice 시뮬레이션을 행하여 램프전압과 전류값을 구하였고, 실제 전자식 안정기를 제가하고 시동특성과 조광특성을 비교분석하였다. 시동특성은 일반 전자식 안정기와 거의 동일하였으며, 조광특성은 전체 광출력의 5%까지 안정동작되어, 제안된 방법이 뛰어남을 확인하였다.

A Study for The X-ray Image Acquisition Experiment Using by Gas Electron Multipliers (기체전자증폭기를 이용한 X-선 영상획득실험에 관한 연구)

  • 강상묵;한상효;조효성;남상희
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.83-89
    • /
    • 2003
  • The gas electron multiplier placed in the drift volume of conventional gas detectors, is a conceptually simple device for producing a large gas gain by concentrating the drift electric field over a very short distance to the point that electron avalanching occurs(〉 10$^4$ V/cm), greatly increasing the number of drifting electrons. This device consists of a thin insulating foil of several tens of urn in thickness. covered on each side with a thin metal layer(Cu), with tiny holes, usually 100 ${\mu}{\textrm}{m}$ or less in diameter. and with a spacing of 100-200 ${\mu}{\textrm}{m}$ through the entire foil. perforated by using chemical etching or high-powered laser beam technique In this study, we have investigated its operating properties with various experimental conditions, and demonstrated the possibility of using this device as a digital X-ray imaging sensor, by acquiring X-ray images based on the scintillation properties of the gas electron multiplier with standard CCD camera.

A study of UPFC model for Power system Analysis (전력계통 해석을 위한 UPFC 모델 연구)

  • Chang, Byung-Hoon;Jun, Young-Su;Kim, Jong-Sun;Lee, Ki-Sun;Chu, Jin-Bu;Baek, Young-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.832-834
    • /
    • 1997
  • 최근 전력계통 운용상 문제점을 해결하기 위하여 대용량 반도체 스위칭 소자를 이용한 전력전자 설비인 FACTS에 관한 연구가 활발히 진행되고 있다. FACTS 설비는 신속한 응답, 다양한 출력변화, 정교한 출력제어 등의 특성으로 전력 계통 적용시 송전용량 증대, 조류제어 등의 효과를 가져오고 있다[7,8]. 본 논문에서는 최근 개발된 FACTS설비인 UPFC(Unified Power Flower Controllers)에 대한 실계통 적용검토 연구를 위하여, 계통모의용 모델을 제시하고, 이에 대한 적용효과를 샘플계통에서 기존의 FACTS설비인 SVC, STATCOM과 비교하였다.

  • PDF

Implementation of Physical Unclonable Function(PUF) using Transmission Line Crosstalks (전송선의 크로스토크를 이용한 물리적복제방지기능(PUF) 구현)

  • Lee, Kwan-Hee;Kim, Seung-Youl;Cho, Kyoungrok;You, Younggap
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.75-82
    • /
    • 2013
  • This paper presents a PUF circuit based on the randomness of crosstalk magnitudes in adjacent transmission lines. Conventional PUF circuitry suffers the reliability problem where a consistent output value is not guaranteed due to environmental changes, such as power supply voltage and operating temperature. The proposed circuit consists of three transmission lines. The crosstalk difference between two transmission line pairs can be arbitrary. The proposed circuit compares the crosstalk differences between two transmission line pairs, and yields consistent responses. The crosstalk differences are immune to operating environment changes. The proposed PUF circuit provides with reliable responses for given challenges. It can be utilized by security systems such as authentication and encryption.

The dosimetric Properties of Electron Beam Using Lyon Intraoperative Device for Intraoperative Radiation Therapy (LID (Lyon Intraoperative Device) 이용한 수술중 방사선치료시 전자선의 선량분포 특성)

  • Kim Kye Jun;Park Kyung Ran;Lee Jong Young;Kim Hie Yeon;Sung Ki Jocn;Chu Sung Sil
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.85-93
    • /
    • 1992
  • We have studied the dosimetric properties of electron beam using Lyon intraoperative device for intraoperative radiation therapy. The dosimetry data had compiled in such a way that a quick and correct decision regarding the cone shape, energy, and accurate calculations could be made. Using 3 dimensional water phantom, we have got the following data: cone output ratios, surface dose, $d_{max}$, $d_{90}$, flatness, symmetry, beam profiles, isodose curve, and SSD correction factors. The cone output ratios were measured with straight and bevelled cone, respectively. As the cone size and the energy were reduced, the cone output ratios decreased rapidly. With the flattening filter, the surface dose increased by electron beam to $85.3\%$, $89.2\%$, and $93.4\%$, for 6 MeV, 9 MeV, and 12 MeV, respectively. It is important to increase the surface dose to $90\%$ or more. Inspite of diminishing dose rate and beam penetration, this flattening filter increases the treatment volume significantly. With the combination of the three levels collimation and the flattening filter, we achieved good homogeneity of the beam and better flatness and the diameter of the 90$\%$ isodose curve was increased. It is important to increase the area that is included in the $90\%$ isodose level. The value of measured and calculated SSD correction factors did not agree over the clinically important range from 100 cm to 110 cm.

  • PDF

Numerical Investigation on Propagation Characteristics of Novel Grating-Assisted MMI Coupler (새로운 격자 구조형 다중모드 간섭 결합기의 전파특성에 관한 수치 해석적 고찰)

  • Ho, Kwang-Chun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.29-34
    • /
    • 2008
  • The propagation characteristics of novel grating-assisted multimode interference (GA-MMI) coupler are explicitly and theoretically investigated by using longitudinal modal transmission-line theory (L-MTLT). The coupling efficiency of GA-MMI coupler is evaluated along the variation of grating thickness and duty cycle, and the spectrum is analyzed numerically. The numerical results reveal that the coupling length and the efficiency of $2{\times}2$ GA-MMI coupler along the variation of grating structure have low tolerance and the bandwidth varies dramatically along the output states.

Research on PAE of CMOS Class-E Power Amplifier For Multiple Antenna System (다중 안테나 시스템을 위한 CMOS Class-E 전력증폭기의 효율 개선에 관한 연구)

  • Kim, Hyoung-Jun;Joo, Jin-Hee;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.12
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, bias control circuit structure have been employed to improve the power added efficiency of the CMOS class-E power amplifier on low input power level. The gate and drain bias voltage has been controlled with the envelope of the input RF signal. The proposed CMOS class-E power amplifier using bias controlled circuit has been improved the PAE on low output power level. The operating frequency is 2.14GHz and the output power is 22dBm to 25dBm. In addition to, it has been evident that the designed the structure has showed more than a 80% increase in PAE for flatness over all input power level, respectively.