• Title/Summary/Keyword: 전위

Search Result 3,418, Processing Time 0.04 seconds

TREATMENT OF TRANSPOSED AND IMPACTED MAXILLARY ANTERIOR REGION : A CASE REPORT (전위 매복된 상악 측절치와 상악 견치의 치험례)

  • Lee, Ki-Young;Choi, Hyung-Jun;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.630-635
    • /
    • 1999
  • Transposition has been described as an interchange of position of permanent tooth and is a relatively rare dental anomaly. Transposition of teeth may occur both in the maxillary and mandibular arches. but it appears more often in the maxilla of individual teeth, the maxillary canine is the most often involved. A canine transposes most often with a first premolar and less frequently transposes with a lateral incisor. Incomplete transposition is a condition describing an interchange in the position of the crowns of two permanent teeth, while the root apices remain in their relative position. Complete transposition is a situation in which both the crowns and entire root structure are transposed. The etiologic factors of transposition are tooth buds interchange, retained deciduous canines, migration of the erupting canine, trauma to deciduous teeth etc. This report describes a case of a transposition between a maxillary left canine and a lateral incisor and impaction of a maxillary left central incisor due to trauma to deciduous dentition.

  • PDF

A Technical Review on Principles and Practices of Self-potential Method Based on Streaming Potential (흐름 전위에 기초한 자연 전위 탐사법의 원리 및 활용)

  • Song, Seo Young;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.4
    • /
    • pp.231-243
    • /
    • 2018
  • Streaming potential (SP) arises from fluid flow through effectively connected pores. From this potential, formation water information as well as fluid flow properties can be estimated. As micro particles being located in boundary between subsurface porous media and fluid are charged to form electrical double layer, fluid flow caused by several reasons generates SP, one of electrokinetic phenomena. Occurrence mechanism of SP is complex and signal strength is relatively weak compared to noise. However, application of self potential survey using SP to monitoring of formation fluid is expanding because of its' convenience of exploration without artificial source and repetitiveness of signal. This paper accounts for the occurrence mechanism of SP studied before, including governing equations and analyzes previous various case studies of SP according to the change of physical properties of materials. It helps to increase understanding about SP and also lays the foundations of the application of SP to fields.

Dislocation behavior in the ZnSe crystal (ZnSe 단결정내에서의 전위거동)

  • 이성국;박성수;김준홍;한재용;이상학
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.4
    • /
    • pp.560-566
    • /
    • 1997
  • Dislocation behavior in the ZnSe crystal grown by seeded vapor transport was investigated. Etch pit shape with the ZnSe plane and dislocation arrangement were shown. Also the variation of the dislocation density in the crystal was disclosed. The dislocation density along the lateral growth direction was not changed but the dislocation density along the vertical growth direction was reduced as the crystal grew. The average dislocation density of the grown crystal was $4{\times}10^4 /\textrm{cm}^2$.

  • PDF

The Influence of Distance between Current Supply Points on Potential Drop in DCPD (직류전위차법에서 전류 입출력점 사이 거리가 전위차에 미치는 영향)

  • Lee, Jeong-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.104-107
    • /
    • 2009
  • It was verified that the effect of the distance between current input point and output point on direct current potential drop(DCPD) in the material with two-dimensional surface notch. If the distance between potential drop measuring points was fixed at a certain distance, the potential drop was decreased with increasing the distance between current input and output points. Hence it is the effect way to increase sensitivity in DCPD that the current input and output points should be located near the potential measuring points. DCPD was a useful method for surface crack sizing because the potential drop was proportional to the length of notch. When the current input and output points are located near the potential measuring points, even small length crack can be measured by DCPD technique.

An Analysis of Potential Interference Effects in the Vicinity of a Vertical Ground Rod (수직 접지전극 주변에서 전위간섭 영향분석)

  • Cho, Yong-Seung;Yang, Soon-Man;Yoo, Yang-Woo;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1570-1571
    • /
    • 2011
  • 인접한 독립 접지전극에 접지전류가 인가된 경우 접지전극 상호간 전위간섭을 일으키게 된다. 상용주파수 접지전류에 대한 전위간섭은 많은 분석이 이루어 졌으나, 뇌서지와 같은 고주파수를 포함하는 접지전류에 대한 전위간섭의 분석은 충분히 수행되지 못하였다. 본 논문에서는 상호간 영향을 줄 수 있는 길이 4 m인 수직 접지전극을 대상으로 주파수에 따른 전위간섭의 영향을 분석하였으며, 수직 접지전극의 주변에 나타나는 대지표면전위와 함께 상호 비교 분석하였다. 그 결과, 전위간섭은 접지임피던스의 변화에 의존하는 경향성을 나타내었으며, 수직 접지전극 길이의 1.5배에 해당하는 이격거리에서 접지전극의 전위와 대지표면전위가 거의 일치하는 것으로 나타났다.

  • PDF

Electrolyte Changes of Blood and Rumen Juice in Experimental Abomasal Diseases of Goats (실험적으로 유발시킨 산양의 제4위질병에 있어서 혈액 및 제1위액의 전해질치 변화)

  • 권오덕;이주묵;박진호;이현범;장종식;채준석
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.258-262
    • /
    • 1997
  • 반추수의 제4위질병시 혈액 및 제1위액의 전해질치 변화에 관해 알아보기 위해 산 양을 대상으로 실험적으로 제식위좌측전위, 제4위우측전위 및 제4위염전을 유발시켰다. 혈청내 $Cl^{-}$치는 제실킨좌측전위, 제4위우측전위 및 제4위염전 모두에서 시간이 경과함에 따라 감소경향 을 나타내었으며 이러한 경향은 제4위우측전위 및 제4위염전에서 더욱 현저하였다. 혈청내 $K^{+}$ 룽도는 제4위좌측전위 및 제4위우측전위에서는 실험 120시간 이후부터 감소경향을 나타내었 으며, 제4위염전에서는 24시간 이후부터 심한 감소경향을 나타내었다. 혈청내 $Na^{+}$치는 제4위좌측전위 및 제4위우측전위에서는 각각 48시간 및 72시간 이후부터 감소경향을 나타내었으며, 제4위염전에서는 24시간 이후부터 유의한 감소경향을 나타내었다. 제1위내 $Cl^{-}$치는 제4위좌측전위 및 제4위우측전위에서는 48시간 이후부터, 제4위염전에서는 12시간 이후부터 시간이 경과함에 따라 증가경향을 나타내었으나 $K^{+}및Na^{+}$농도는 유의한 변화가 인정되지 않았다.

  • PDF

Artificial Potential Function for Driving a Road with Traffic Light (신호등 신호에 따른 차량 주행 제어를 위한 인공 전위 함수)

  • Kim, Duksu
    • Journal of KIISE
    • /
    • v.42 no.10
    • /
    • pp.1231-1238
    • /
    • 2015
  • Traffic light rules are one among the most common and important safety rules as the directly correlate with the safety of pedestrians. Consequently, an algorithm is required to cause an automated (or semi-automated) vehicle to observe traffic light signals. We present a novel, artificial potential function to guide an automated vehicle through traffic lights. Our function consists of three potential function components representing the three traffic light colors: green, yellow, and red. The traffic light potential function smoothly changes an artificial potential field using the elapsed time for the current light and light conversion. Our traffic light potential function is combined with other potential functions to guide vehicles' movement and constructs the final artificial potential field. Using various simulations, we found or method successfully guided the vehicle to observe traffic lights while behaving like human-controlled cars.

A Basic Study on Micro-Electric Potential accompanied with Specimen Failure during Uniaxial Compressive Test (일축 압축에 의한 시료 파괴 시 수반되는 미소 전위에 대한 기초 연구)

  • Kim, Jong-Wook;Park, Sam-Gyu;Song, Young-Soo;Sung, Nak-Hun;Kim, Jung-Ho;Cho, Seong-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.203-210
    • /
    • 2007
  • As a part of basic studies on monitoring of landslides and slope stability using SP measurements, micro-electric potentials of rock samples were measured accompanied with the rock failure by a uniaxial loading test were measured. The measurement system consists of a 8 channel A/D converter with 24 bit resolution, uniaxial loading tester, strain gages and 4 sets of electrode attached to a rock sample. Rock samples of granite, limestone, and sandstone were tested. Also, mortar samples were tested in order to monitor electric-potentials of a uniform sample. Micro-electric potentials were detected in all saturated samples and the strength of them increased as the loading force increased. Sandstone samples showed the largest strength of micro-electric potential and it followed limestone and granite samples, which indicates a positive relationship with porosity of rocks. The mechanism generating these micro-electric potential can be explained in terms of electro-kinetics. In case of dry samples, micro-electric potential could be observed only in sandstone samples, where piezoelectric effect played main role due to high contents of quartz in sandstone samples. We found that biggest micro-electric potentials were observed at the electrodes near the crack surface of rock samples. This is very encouraging result that SP monitoring can be applied to predicting landsliding or to estimate collapsing position combining with monitoring of acoustic emissions.

Relative Error Analysis for Measuring Value of Ground Resistance according to Position Variation of Potential Probe) (전위보조전극의 위치변화에 따른 접지저항 측정값의 상대오차분석)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.96-102
    • /
    • 2009
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error for measuring value of ground resistance due to the position of the potential probe, ground resistance were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from l0[m] to 50[m]. Also, the potential probe was located at 30[$^{\circ}$], 45[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$] and 180[$^{\circ}$]. As a consequence, relative error decreased with increasing the distance of potential probe and decreasing the angle between current probe and potential probe. The results could be help to determine the position of potential probe when the ground resistance was measured at grounding system.

Dislocation analyses of semi-brittle fracture I

  • Chung, Soon-Kil;Lee, Byung-Ho
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.2
    • /
    • pp.101-109
    • /
    • 1981
  • 균일 인장하중하에 있는 고체 내부에 고립된 제 1형 탄소성 크랙의 반취성 파괴를 경사슬립밴드모델(inclined slip band model)로서 연속크랙전위(conticuum crack dislocation) 및 연속격자 전위(continum lattice dislocation)을 이용하여 이론적으로 연구하였다. 크랙전위 및 격자전위에 관한 힘평형을 나타애는 연립특이적분방정식의 해는크랙전위 및 격자전위에 관한 적정밀도함수를 가지고 특이함을 해소하는 조건을 부가하여 얻는다. 이특이항 해소조건의 타당성은 처음으로 소성영역의 크기를 그 판단기준으로 검토되었으며, 그결과 합당한 것으로 확인되었다. 또한 상기방법으로부터 산출된 COD는 소규모 성역을 넘어서도 선형적으로 .KAPPA.$^{2}$.EPSILON..sigma.$_{Y}$ 에 따라 변화함을 알게 된다. 상기모델에서 위축적분경로(Shrunk path) 상의 J 적분치를 J=.delta..sigma.$_{Y/}$sin2.theta.의 형태로 유도하였는데, 이것은 J 적분에 관한 Eshelby의 힘개념을 구체적으로 표현한다: J는 크랙전파방향으로 탄소성크랙정점에 작용하는 가상적인 힘이며, 1/2 J의 한 슬립편면상에서의 분력은 그 슬립정면사으이 보든 격자전위에 작용하는 전단력의 총화와 같다. 같다.