• Title/Summary/Keyword: 전여과

Search Result 243, Processing Time 0.032 seconds

Pretreatment of Acrylic Wastewater and Application of UF/RO Processes (Acrylic 폐수의 전처리 및 UF/RO공정의 적용)

  • 이광현
    • Membrane Journal
    • /
    • v.11 no.4
    • /
    • pp.152-160
    • /
    • 2001
  • The pretreatment for COD removal of acrylic wastewater and separation characteristics of ultrafiltration hollow fiber type module and reverse osmosis spiral wound type module with the variation of applied pressure and temperature were discussed. Thc optimum washing time of membranes was decided with long team operation and the degree of fouling was discussed with operating time. Permeate flux was decreased rapidly at 14 hrs and that of reverse osmosis membrane was indicated similarly. CaO find sand filter for the first step, neutralization process with treated acrylic wastewater as the second step, UF/RO processes were used as final strep. It was shown treat COD and TDS were below allowable discharge value with the result.

  • PDF

Development of Non-point Pollution Facility for Forest Filtration Using Oyster Shell and Natural Mineral (굴패각과 천연광물질을 이용한 수목여과용 비점오염시설 장치 개발 연구)

  • Kim, Jeong Ho;Ku, Hyun Woo;Lee, Young Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.53-57
    • /
    • 2018
  • 고도의 산업화에 따라 도시의 성장과 인구의 밀집으로 인하여 물의 수요가 증가하고 이에 따라 각종 오염원의 유입이 증가함에 따라서 적절한 수질 관리에 대한 필요성이 대두되고 있다. 그리고 산업이 다양화됨에 따라 배출되는 하 폐수의 특성도 다양해져 기존의 수질처리장은 효율적인 처리를 하는데 있어 많은 어려움이 발생되고 있다. 굴 패각은 하수처리의 담체로 이용할 경우 살수여상의 문제점 중 하나로 나타나는 막힘 현상을 다소 감소시킬 수 있고, 다공질체로서 표면적이 불규칙하고 비표면적이 크기 때문에 반응기내에 공기를 원활하게 공급할 수 있으며, 중금속 이온과 유기물에 대한 흡착 효율이 뛰어나 미생물이 쉽게 부착, 성장할 수 있는 장점을 가지고 있다. 천연광물질은 전 세계적으로 발견되어 활용된 역사가 짧지만, 그 특징은 산소결핍보충, 유해원소 흡착 성능, 반도체 작용, 인체 면역력 강화, 바이러스성 질병의 예방, 중금속 해독 등의 다양한 특징으로 환경호르몬 제고, 음이온 원적외선 발생으로 세포의 노화방지, 인체 노폐물 제거와 같은 특징을 지닌 매우 유용한 자원으로 확인되고 있으며, 수질정화 능력이 탁월한 것으로 보고 있다. 이에 본 연구는 어촌폐기물인 굴 패각과 수질정화에 탁월한 천연 광물질을 혼합하여 경제적이고, 효율성이 높은 다공성 수질개선 담체를 개발하고, 수목여과용 비점오염시설 장치에 적용하여 혼합 담체가 수처리 시설의 담체로서 사용이 가능한지, 수목여과용 비점오염시설 장치에 적용할 수 있는지 검토하고자 수행하였다. 이 연구는 2017년 중소기업청 기술개발사업에서 연구지원을 받아 연구되었습니다.

  • PDF

Analysis of Hydrophobic Membrane Fouling on the COD Loading Rates at the State of Passive Adsorption in Membrane Bioreactor (생물학적 막분리 공정에서 수동흡착 상태에서의 유기물 유입 부하에 따른 소수성 막의 오염도 분석)

  • Park, Tae-Young;Choi, Changkyoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.152-158
    • /
    • 2015
  • This paper investigated the membrane fouling potential at the state of passive adsorption which is no permeation with the test modules on COD (Chemical oxygen demand) loading rates, examined the recovery rate and resistance on membrane fouling by three cleaning manners of hydrophobic membrane in a bioreactor. The results showed that high COD loading led to the increase of extra-cellular polymeric substances and filtration resistance. The permeability resistance from 1st day to 63rd day was getting increased, however, the value of permeability resistance after 63th day during the operation period was almost same level at three COD loading rates, it was due that the biomass adhesion on membrane surface at the state of passive adsorption reached to the critical state. Also, the final recovery rates after three cleaning manners were 78%, 72% and 69% at the COD loading concentrations of 250 mg/L, 500 mg/L and 750 mg/L respectively, and then recovery rate by physical cleaning at Run 2 and Run 3 was decreased after 40th day, it proved that biomass cake, which is not easily removed, was formed on the membrane surface because of high COD loading rate and EPS concentration.

A Analysis of Effectiveness of Aluminium Filter in the added Compound Filtration by Detective Quantum Efficiency and Image Quality Evaluation (복합부가여과에서 알루미늄 여과판 사용 시 양자검출효율과 화질평가를 통한 효율성 분석)

  • Kim, Sang-Hyeon;Kim, Yun-Min;Kwon, Kyoung-Tae;Ma, Sang-Chull;Han, Dong-Gyoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.10
    • /
    • pp.362-373
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation from high atomic number material by DQE and image evaluation. 1mm Al was applied to each 0.1, 0.2, 0.3 mm copper and befere and after use were evaluated. Beam quality and DQE were tested by IEC regulations and image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by 7 items for resolution and contrast from chest x-ray criteria of national cancer checkup. MTF 10 and 50% were the same by 4.6, 2.54 cycle/mm and NPS, DQE, PSNR MAE, MSE, CNR, SNR and qualitative analysis were all the same or slightly better when Al was not used. PSNR is over 30dB and all significant and at the qualitative analysis, the p-value of t-test was over 0.05. The DQE and image quality evaluation have little difference between before and after use of Al filter and it is effective to use the Al filter for the reduction of skin dose by removal of characteristic radiation.

Biotreatment Technologies for Air Pollution Control (생물학적 처리기술을 이용한 대기오염 제어)

  • Won, Yang-Soo
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.1-15
    • /
    • 2007
  • Biological treatment is a relatively recent air pollution control technology in which off-gases containing biodegradable odors and volatile organic compounds(VOCs) are vented through microbes. It is a promising alternative to conventional air pollution control methods. Bioreactors for air pollution control have found most of their success in the treatment of dilute and high flow waste air streams containing VOCs and odor compounds. They offer several advantages over traditional technologies such as incineration or adsorption. These include lower treatment costs, absence of formation of secondary pollutants, no spent chemicals, low energy demand and low temperature treatment. The three most widely used technologies are described, namely biofiltration, biotrickling filtration, bioscrubbing. The most widely used bioreactor for air pollution control is biofilter, but it has several limitations. In the past years major progress has been accomplished in the development of vapor phase bioreaction systems, for solving problems of biofilter. Biotrickling filters are more complex than biofilters, but are usually more effective, especially for the treatment of compounds which are difficult to degrade or compounds that generate acidic by-products. This, paper reviews fundamental and theoretical/practical aspect of air pollution control in biofilter, biotrickling filter and bioscrubber, focusing more extensively on biotrickling filtration. Special emphasis is given to the operating parameters and the factors influencing performance for air pollution control, and cost estimation in biotreatment technologies.

  • PDF

An Experimental Study on Filtration Efficiency of Sand Filter Layers to TSS and COD in Non-point Source Pollutant (분산형 빗물 저류조용 모래 여과층을 적용한 도심지 비점오염원의 TSS와 COD 정화효율에 대한 실험적 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1477-1488
    • /
    • 2014
  • Prevalent construction of impermeable pavements in urban areas causes diverse water-related environmental issues, such as lowering ground water levels and shortage of water supply for the living. In order to resolve such problems, a rainwater reservoir can be an effective and useful solution. The rainwater reservoir facilitates the hydrologic cycle in urban areas by temporarily retaining precipitation-runoff within a shallow subsurface layer for later use in a dry season. However, in order to use the stored water of precipitation-runoff, non-point source pollutants mostly retained in initial rainfall should be removed before being stored in the reservoir. Therefore, the purification system to filter out the non-point source pollutants is essential for the rainwater reservoir. The conventional soil filtration technology is well known to be able to capture non-point source pollutants in a economical and efficient way. This study adopted a sand filter layer (SFL) as a non-point source pollutant removal system in the rainwater reservoir, and conducted a series of lab-scale chamber tests and field tests to evaluate the pollutant removal efficiency and applicability of SFL. During the laboratory chamber experiments, three types of SFL with the different grain size characteristics were compared in the chamber with a dimension of $20cm{\times}30cm{\times}60cm$. To evaluate performance of the reservoir systems, the concentration of the polluted water in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) were measured and compared. In addition, a reduction in hydraulic conductivity of SFL due to pollutant clogging was indirectly estimated. The optimum SFL selected through the laboratory chamber experiments was verified on the in-situ rainwater reservoir for field applicability.

Filtration characteristic of quantity of coagulant and variable pressure (응집제의 주입량 및 압력변화에 따른 여과특성)

  • Lee, Sung-ho;Lim, Taek-jun;Cho, Jun-hyung
    • Journal of Forest and Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2001
  • Compared to other industries, pulp and paper industry use a lot of water. As a result, a large amount of the waste water is discharged in the pulp and paper industry. This study was investigated to prevent the environmental pollution terribly faced with our society nowadays. In the waste water of pulp and paper, there are so many things in the waste water, like fiber, filler, and other organic solvent etc. so we must remove them from our environment. This study was investigated to experiment on test of impressed filtration with the kind and quantity of coagulant and the variance of pressure. In this study, we used feds, alums. $CaCl_2$, polymer as a coagulant and these pressure was 49, 98, 147, 196kpa. According to this study, we measured the speed of filtration and turbidity, measuring filtrated water. According to the values, we know the fact that as the consistency of coagulant and pressure were high, the filtration was good.

  • PDF

나일틸라피아의 암모니아 배설에 미치는 어체중, 먹이 공급 비율, 사료 내 단백질 함량의 영향

  • 오승용;조재윤
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.05a
    • /
    • pp.311-312
    • /
    • 2001
  • 앞으로의 양식 방법은 자연 환경을 훼손시키지 않는 환경 친화적 양식을 모색해야만 하며 오배수는 자연 수계로 배출하기 전 처리하여 생태계의 균형을 깨뜨리지 않는 양식 방법으로 생산성을 올려야만 한다. 이에 소량의 물 사용과 적절한 수처리 기술을 이용한 순환여과식 양식 방법은 전 세계적으로 관심을 받고 있으며, 환경 단체나 정부 및 지역 단체의 지지를 얻고 있다(Van Rijn, 1996). (중략)

  • PDF

Site Suitability Analysis for Bank Filtration Using AHP (AHP를 이용한 강변여과 적지 분석)

  • Kim, Byeong-Chan;Lee, Seung-Chui;Ryu, Ji-Hyeob
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.2
    • /
    • pp.53-59
    • /
    • 2008
  • The lack of water resources is becoming a serious issue throughout the world. The water shortage in Korea is expected to increase. Groundwater can be a solution to this matter in some places. Especially, bank filtrations are known to be advantageous over conventional reserviors, even if they have some drawbacks such as their limited location for development and small sizes. The AHP(Analytic Hierarchy Process) is an analytical tool, supported by simple mathematics, which enables one to explicitly rank tangible and intangible factors against each other for the purpose of resolving conflicts or setting priorities. In order to check the applicability of AHP to the evaluation of bank filtration sites, four candidate locations were chosen. They have suffered from problems like water-supply shortage and delayed dam construction. The analysis results are compared with those of the previous study using a conventional method. It is believed that the developed method can a basis for reasonable decision-making regarding bank filtration development.

  • PDF

Performance Evaluation for Water Quality Enhancement (수질향상을 위한 정수장 성능평가)

  • Simpson Stephen-L;Singer Charlie
    • 수도
    • /
    • v.24 no.4 s.85
    • /
    • pp.30-38
    • /
    • 1997
  • County는 비용과 부지소요는 최소화하면서도 증가하는 지역적 물수요에 부합되는 높은 유량에서 정수장의 성능을 최대화해야하는 필요성에 직면해있다. 개선사항을 찾아내기 위하여 시설물에 대한 상세한 성능평가가 행해졌다. 성능평가는 여과와 소독공정이 운전방식의 조정과 함께 추가시설의 건설에 의하여 개선될 수 있음을 나타내었다. Pilot test는 실험된 여러 가지 대안들 중에서 혼화, 응집, 이중 여과방식이 입자의 제거와 정수 수질에 가장 좋은 것임을 보여주었다. 소독에 대한 분석 결과는 소독방법을 교정하고 추가적인 염소접촉시간을 주는 것이 소독의 안전성을 확보함과 동시에 정수의 소독부산물 농도를 최소한으로 하고 강화되는 규제치와 부합할 수 있는 최선의 방법이 될 것이라는 것을 보이고 있다. Pilot test는 저수두 자동역세척여과지가 1차여과지(roughing filter)로서 효과적이라는 것을 보여주었다. 실험결과는 이중여과가 최종유출수의 탁도를 평균 0.1NTU이하로 감소시키며 입자의 제거율을 3 log로 증가시킴을 나타내고 있다. 정수공정 전반에서의 입자의 제거는 여러 개의 공정의 개별적 성과의 합이 아니므로 시설물들을 건설하기 전에 정수장 전체적으로 예상되는 개선정도를 수량화하기 위하여 Pilot 실험이 필요하였다. Pilot test중에 탁도보다는 입자측정이 유량, 응집제의 주입량, 및 여타 운전조건의 변화에 훨씬 민감함을 보여주었다. 이러한 점이 입자측정이 특히 저탁도 원수에서 처리공정의 성능을 나타내 주는 적절한 추가적 수질인자라는 결론을 보강하여 주었다. 물수요에 부합하기 위하여 Freedom District 정수장을 성공적으로 개선하는 데는 원수의 수질, 단위공정의 성능, 활용가능한 수리학적 수두, 현시설의 배치, 운전양태 등과 같은 기술적 사항에 대한 고려가 필요하였다. 비록 모든 사항들이 각각 일정정도의 영향을 가지고 있으나, 상기의 모든 것들이 수질에 영향을 미쳤으며 수질의 성공적인 개선은 정수장 운전의 모든 부분을 파악할 수 있는 상세한 성능평가를 통하여 가장 잘 달성될 수 있다.

  • PDF