• Title/Summary/Keyword: 전에너지 방출율

Search Result 10, Processing Time 0.032 seconds

The Evaluation of Fracture Toughness of SMC Composite Material and Carbon/Epoxy Composite Material (SMC 복합재료와 Carbon/Epoxy 복합재료의 파괴인성평가)

  • 최영근;이유태;이태순
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.25-32
    • /
    • 1993
  • In composite materials, the fracture perpendicular to the fiber direction usually shows a non-linear behavior accompannying blunting and plastic deformation around the crack tip. In this study, the fracture thoughness in random short fiber SMC composite material and Carbon/Epoxy composite material is estimated by the A.M.(Area Method) and the G.L.M.(Generalized Locus Method) which can determine a stable total energy release rate(G$_T$) not only in highly elghly elastic material but also in highly non-linear materials.

  • PDF

The Energy Release Rate of the Two Dimensional Cracked Body Under Thermal Stresses, Body Forces and Crack-Face Tractions (열응력, 내력 및 균열 경계하중을 고려한 2차원 균열문제의 에너지방출율)

  • 이태원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2172-2180
    • /
    • 1993
  • Under general loadings, including body forces, crack-face tractions and thermal loading, the energy release rate equation for a two-dimensional cracked body is presented. Defining the virtual crack extension as the variation of the geometry, the equation is directly derived by a shape design sensitivity of the potential energy. Although the form of the derived energy release rate equation is different from other researchers's results, the three example show that the former is exactly the same as the latter. However, the final integral equation do not involve the derivative of the displacement on the crack surface and crack tip region, thereby improving the numerical accuracy in the computation of the energy relase rate. Moreover, as it was derived from the governing equation including non-linear elasticity without special assumptions, the energy release rate of a elasto-plastic fracture can be obtained and any numerical stress analysis method can be applied.

선박의 속도 저하를 고려한 운항효율제고에 관한 연구

  • Gong, Gil-Yeong;Lee, Bo-Gyeong;Lee, Yun-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.198-200
    • /
    • 2013
  • 최근 국제해사기구(IMO)의 해양환경보호위원회에서(MEPC)는 선박에서 대기로 방출되는 CO2의 양을 최소로 하기 위해서 신조선 설계 건조시 에너지효율지수(EEDI : Energy Efficiency Design Index for new ships), 에너지 효율지표(EEOI : Energy Efficiency Operational Indicator), 그리고 에너지 효율관리 계획(SEEMP : Ship Energy Efficiency Management Plan) 지수들을 이용하여 전 세계 이산화탄소 배출 규제 방침을 운영하고 있다. 이러한 환경규제 강화와 발맞추어 세계 각국은 지속적인 Green-ship의 개발과 저탄소 고효율 선박의 운항을 위해 연구와 노력한다. 본 연구에서는 선박이 움직이는데 있어 동력이 시작되는 부분과 그 힘이 전달되어 운항자의 의식이 반영되어 선체의 이동으로 이어지기까지 흐름에 대해 도식 및 수식으로 정리하였다. 그리하여 해상의 상태와 이에 따른 운항결정이 어떤 결과를 초래할 수 있는지 살펴보고 이 부분에서 운항효율을 증대시킬 수 있는 부분에 대해 모색해 보았다. 또한 엔진의 상태에 따른 연료 절감율에 대해 살펴보고 보다 경제적 운항을 위한 적정 RPM과 속도 등에 대해서 고찰해 보았다. 이 같은 정리를 통해 앞으로의 Echo-ship, Green-ship의 연구방향에 대한 초석으로 삼고자 한다.

  • PDF

투명전극용 박막의 제작과 전기적인 특성에 대한 연구

  • O, Teresa
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.42.1-42.1
    • /
    • 2011
  • 박막형 디스플레이구서에 있어서 투명전극은 필수적이다. 투명전극은 정보를 표시하기 위해 빛을 외부로 방출시키거나 태양광 등을 소자 내부로 입사시켜야 한다. 또한 전극을 형성하는 박막은 높은 광투과율과 ${\sim}10-4{\Omega}cm$ 정도의 낮은 전기비저항을 가져야 한다. 가장 널리 사용되는 투명전극으로 ITO (Indium Tin Oxide)는 인듐의 독성, 저온증착의 어려움, 스퍼터링시 음이온 충격에 의한 막 손상으로 저항의 증가 및 액정디스플레이의 투명전극으로 사용될 경우 $400^{\circ}C$정도의 높은 온도와 수소플라즈마 분위기에서 장시간 노출시 열화로 인한 광학적 특성변화가 문제로 지적된다. 이러한 문제 해결의 대안으로 ZnO 산화물 반도체가 있는데 ITO 박막에 비해 비저항이 높기 때문에 도핑을 이용한 비저항을 ${\sim}10-4{\Omega}cm$ 정도로 낮추어야 한다. 투명전도막으로는 ITO, FTO 등과 더블어 체적 저항율은 다소 높으나 환원성 분위기에 대한 내성, 가시광 영역에서의 높은 광투과율과 저렴한 가격 등의 장점 등으로 AZO 박막이 주목 받고 있다. ZnO는 ITO 나 FTO에 비해서 700 kJ/mol의 큰 분해에너지를 가지므로 코팅 때 발생하는 전도도 및 투과율이 나빠지는 현상이 발생하지 않는 특징이 있으며, 위의 두 재료에 비해 밴드갭도 가장 낮아서 자외선 투과율이 낮다. 그러나 내습성이 약하기 때문에 이를 보완하기 위하여 내습성향상과 전도성 향상을 위해서 3족 원소인 B, In, Al, Ga 등을 도핑한 ZnO 투명전도막의 연구가 진행되고 있다. 이러한 원소들 중에서 Al로 도핑했을 때 가장 낮은 비저항을 얻을 수 있다고 알려져 있다. 본 연구에서는 SiOC 박막위에 AZO 박막을 제조하기 위하여 RF 마그네트론 스퍼터링법을 이용하여 박막을 성장시켰으며, 박막의 전기적 및 광학적 특성을 조사하였다. AZO 박막은 rf power가 5~200 W인 RF 마그네트론 스퍼터 방법에 의해서 제작되었다. SiOC 박막은 산소와 DMDMOS 전구체의 유량비를 다르게 하여 플라즈마 발생 화학적 기상 증착방법으로 증착되었다. 증착된 SiOC박막은 UV visible spectroscopy에 의해서 분석하였다. 투명전극의 비저항은 rf 전력이 작을 수록 낮았으며, SiOC 절연막 위에 AZO를 증착시킨 후 반사률은 반대로 바뀌는 것을 확인하였다.

  • PDF

Brown Adipose Tissue Thermogenesis and Obesity (Brown Adipose Tissue의 열생성 기능과 비만)

  • 양경미;서정숙
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.21 no.4
    • /
    • pp.460-470
    • /
    • 1992
  • Thermogenesis in brown adipose tissue (BAT) can serve the animal in the regulation of its body temperature and of its body weight. Thermogenesis can be switched on by exposure of the animal to cold (non-shivering thermogenesis) or by overeating (diet-induced thermogenesis). BAT mitochondria are uniquely specialized for thermogenesis, possessing a specific proton conductance pathway that is regulated by the concentration of fatty acids in the cells of BAT. The level of fatty acids is in turn controlled by the lipolytic action of noradrenaline on the tissue. When the proton conductance pathway operates, the mitochondria are effectively uncoupled and exhibit extremely high rates of substrate oxidation with a great increase in heat production. Thus it is suggested that BAT is of importance in energy balance and human obesity treatment if thermogenesis can be stimulated specifically.

  • PDF

Multiphonon relaxation and frequency upconversion of $Er^{3+}$ ions in heavy metal oxide glasses ($Er^{3+}$첨가 중금속 산화물 유리의 다중포논 완화와 주파수 상향 전이 현상)

  • Choi, yong-Gyu;Kim, Kyong-Hon;Heo, Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.221-226
    • /
    • 1998
  • Ternary heavy metal oxide glasses in the $PbO-Bi_2O_3-Ga_2O_3$ system doped with $Er_2O_3$ were prepared and their spectroscopic properties, such as radiative transition probability, calculated and measured radiative lifetimes and cross-sections of 1.5 $\mu\textrm{m}$ and 2.7 $\mu\textrm{m}$ emissions were analyzed. Enhanced quantum efficiencies of some electronic transitions were evident mainly because of the low vibrational phonon energy ($~500cm^{-1}$) inherent in the host glasses. This seems to be the main reason for obtaining the 2.7 $\mu\textrm{m}$ luminescence which is normally quenched in the conventional oxide glasses. In addition, green and red fluorescence emissions were observed through the frequency upconversion processes of the 798 nm excitation. Non-radiative transition due to the multiphonon relaxation is a dominant lifetime-shortening mechanism in the 4f-4f transitions in $Er^{3+}$ ion except for the $^4S_{3/2}{\rightarrow}^4I_{15/2}$ transition where a non-radiative transfer to band-gap excitation of the host glasses is dominant. Melting of glasses under an inert gas atmosphere and (or) addition of the typical glass-network former into glasses is necessary in order to enhance the quantum efficiency of the transition.

  • PDF

Evaluation of SHCC on Direct Tensile Load using Acoustic Emission Technique (음향방출기법을 이용한 혼입되는 섬유의 종류에 따른 SHCC의 직접인장거동특성 평가)

  • Kim, Yun-Su;Yun, Hyun-Do;Jeon, Esther;Park, Wan-Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.177-180
    • /
    • 2008
  • SHCC shows the high energy tolerance capacity due to the interfacial bonding of the fibers to the cement matrix. For effective material design and application of SHCC, it is needed to investigate the damage process and micro-fracture mechanism of cement matrix reinforced with different types of fibers. The objective of this paper is to investigate the direct tensile response of cement composites reinforced with single and hybrid fibers using acoustic emission(AE) technique. In this study, the correlations between AE signal and result of the direct tensile response of SHCC. For these purposes, three kinds of fibers were used: PET1.5%, PET1.0+PE0.5%, PET1.0%+PVA0.5%. The result of the direct tensile response of SHCC, for the same volume fraction of fibers, ultimate strength of PET-PE specimen was 2.7 times higher than specimens with PET fibers. And from AE signal value, AE event numbers and cumulative energy were different according to kind of fiber because of the different material properties of reinforced fiber.

  • PDF

A Study on the Performance and Combustion Characteristics with CNG Substitution Rate in a Diesel Engine (CNG 혼소율 변화에 따른 디젤엔진의 성능 및 연소 특성에 관한 연구)

  • Jang, Hyeong-Jun;Lee, Sun-Youp;Kim, Chang-Gi;Cho, Jeong-Kwon;Lim, Jong-Han;Yoon, Jun-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.700-707
    • /
    • 2017
  • In the international natural gas market, natural gas has markedly low calories. The domestic calories standard of natural gas was changed and the performance and efficiency of many industrial machines using natural gas were affected because of low caloric natural gas. Therefore, in this study, a dual fuel engine fueled with natural gas and diesel was tested to examine the effects of the CNG substitution rate on the combustion characteristics, such as thermal efficiency, COVimep and heat release rate. The CNG substitution rate was defined as the ratio of CNG instead of diesel, which was calculated as the total energy. The conditions of the tested engine were fixed $1800rpm/500N{\cdot}m$. In addition, diesel fuel was injected at $16^{\circ}CA$ BTDC and the fuel pressure was fixed at 85 MPa; the lower heating value of CNG was $10,400kcal/Nm^3$. The results of the engine test showed that the amount of diesel fuel was changed according to the CNG substitution rate. Therefore, when the substitution rate was increased, the amount of diesel fuel was decreased, which affected the energy for ignition. In addition, the ignition delay duration was increased, which affected the thermal efficiency and torque. On the other hand, the COVimep was less than 5% and a stable combustion state of the engine was shown.

The Construction and Application of Planning Support System for the Sustainable Urban Development (지속가능한 도시개발을 위한 계획지원시스템의 구축과 활용에 관한 연구)

  • Lee, Hee-Yeon
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.1 s.118
    • /
    • pp.133-155
    • /
    • 2007
  • The sustainable urban development has emerged as a new paradigm of urban studies in recent years. A review of the literature of land use and transport policies in relation to sustainable development reveals a consensus that the main objectives of sustainable strategy should decrease the numbers and length of journeys, and change the land use pattern towards mixed use and high density. However, there is a lack of empirical research as to what types of policies might influence effectively the reduction in the energy consumption and emission of $CO_2$. in order to sustain urban development. This paper tries to construct the conceptual structure of the PSS(planning support system), which is designed to the simulation of the probable effects of policies and planning of different kinds in cities, and evaluate the sustainablilty level according to construct the structure of the PSS(planning support system), which is designed to the simulation of the probable effects of policies and planning of different kinds in cities, and evaluate the sustainablilty level according to the alternative scenarios. The PSS is composed of three components (input-modeling-output). The core of PSS is integrating land use-transport-environment modeling. The advantages of integrating land use-transport-environment modeling are well known, but there are very few such integrated modeling packages in practice. So this paper tries to apply TRANUS software, which is an integrated land use and transport model. The TRANUS system was calibrated to city of Yongin for the base year. The purpose of the application of TRANUS to Yongin is to examine the operability of TRANUS system in Korea. From the outputs and results of operating the system, TRANUS may be effectively used to evaluate the effects of alternative sustainable urban development policies, since sustainablilty indicators can be extracted from several aspects such as land use consumption, total trips, distance and cost, energy consumption, ratio of transport split.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF