• Title/Summary/Keyword: 전압 발생기

Search Result 1,068, Processing Time 0.029 seconds

Effects of Shape Anisotropy on Memory Characteristics of NiFe/Co/Cu/Co Spin Valve Memory Cells (NiFe/Co/Cu/Co 스핀밸브 자기저항 메모리 셀에서 형상자기이방성이 메모리 특성에 미치는 영향)

  • 김형준;조권구;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.301-305
    • /
    • 1999
  • NiFe(60$\AA$)/Co(5$\AA$)/Cu(60$\AA$)/Co(30$\AA$) spin valve thin films were patterned into magnetoresistive random access memory (MRAM) cells by a conventional optical lithography process and their output and switching properties were characterized with respect to the cell size and geometry. When 1 mA of constant sense current was applied to the cells, a few or a few tens of mV of output voltage was measured within about 30 Oe of external magnetic field, which is an adequate output property for the commercializing of competitive MRAM devices. In order to resolve the problem of increase in the switching thresholds of magnetic layers with the downsizing of MRAM cells, a new approach using the controlled shape anisotropy was suggested and interpreted by a simple calculation of anisotropy energies of magnetic layers consisting of the cells. This concept gave a reduced switching threshold in NiFe(60$\AA$)/Co(5$\AA$) layer consisting of the patterned cells from about 15 Oe to 5 Oe and it was thought that this concept would be much helpful for the realization of competitive MRAM devices.

  • PDF

Ionization Behaviors in Various Soils Subjected to Impulse Currents (임펄스전류에 의한 토양의 종류별 이온화 특성)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Geon-Hun;Baek, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.87-94
    • /
    • 2008
  • This parer presents the soil ionization phenomena and parameters associated to characterize the transient performances of grounding system under lightning impulse Currents. Ionization properties in occurring some soil media were experimentally investigated. The cylindrical test cell was employed in order to facilitate the analysis of soil breakdown field intensity and ionized radius. The soil breakdown field intensity, dependence of impedance on the amplitude of impulse current, V-I curves and transient impedances were discussed based on the voltage and current oscillograms. It was found that the ionization process and dynamic behaviors were strongly dependent on the types of soil and two current peaks were not observed in highly water-saturated soils. The results presented in this paper will provide useful information on the improvement of transient performance of a grounding system subjected to lightning impulse Current considering the soil ionization.

A Study on Fault Model end Performance Evaluation under Power Switch Open Fault in an Inverter-Driven Permanent Magnets Synchronous Motor (영구자석 동기전동기 구동 인버터 스위치의 개방 고장에 의한 제어 특성해석 및 고장모델 연구)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.40-51
    • /
    • 2009
  • To analyze influences under open faults in switching devices of the PWM inverter and under the isolation between the inverter and motor terminal, a faulty model for the inverter-driven permanent magnet synchronous motor is presented. Even though the conventional dq motor model obtained through the transformation of phase voltage model is widely used to analyze and control AC motor, it can not be used under open faults in switching devices since the 3-phase balanced condition is no longer hold under the open fault and it is not easy to obtain motor input voltages in open phase from the pole voltage. To deal with this problem, a faulty model for an inverter-driven permanent magnet synchronous motor is derived by using the line voltage of motor according to switch open, which can be effectively used for performance evaluation of the diagnostic algorithm. The validity of the proposed faulty model is verified through comparative simulations and experiments using DSP TMS320F28335.

Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System (비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2619-2627
    • /
    • 2009
  • The ground fault is occupying 70% among the total number of faults in ungrounded distribution power system. When the ground fault occurs in ungrounded system, the fault current is so small that it is hard to detect. But fault handling is very important because to continue power supply during fault conditions may cause the fault spreading and the distribution device in trouble. This paper presents the fault line detection method by using GPT signal detecting zero sequence voltage, and the fault section detection method by detecting whether GPT signal is disappeared or not during shifting normally open switch, which is connecting switch between distribution lines with open state in order to restore the outage area under emergency situation, and during isolating each section one by one which belongs to the fault line. This method is efficient because there is no whole power interruption during the fault section detection, and it is possible to perform both the fault section detection and the service restoration for the outage area at the same time, and it can apply to various distribution system configuration. Program for the fault restoration was developed applying proposed method, and it has been validated by applying to the pilot project of distribution automation system in Vietnam which has the ungrounded distribution system.

Development of a continuous electrolytic system with an ion exchange membrane for pH-control with only one discharge of electrolytic solution and its characteristics (단일 전해액 배출만을 가지는 pH조절용 연속식 이온 교환막 전해 시스템의 개발과 그 특성)

  • Kim Kwang-Wook;Kim In-Tae;Park Geun-Il;Lee Eil-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.269-278
    • /
    • 2005
  • In order to produce only a pH-controlled solution without discharging any unwanted solution, this work has developed a continuous electrolytic system with a pH-adjustment reservoir being placed before an ion exchange membrane-equipped electrolyzer, where as a target solution was fed into the pH-adjustment reservoir, some portion of the solution in the pH-adjustment reservoir was circulated through the cathodic or anodic chamber of the electrolyzer depending on the type of the ion exchange membrane used, and some other portion of the solution in the pH-adjustment reservoir was discharged from the electrolytic system through the other counter chamber with its pH being controlled. The internal circulation of the pH-adjustment reservoir solution through the anodic chamber in the case of using a cation exchange membrane and that through the cathodic chamber in the case of using an anion exchange membrane could make the solution discharged from the other counter chamber effectively acidic and basic, respectively. The phenomena of the pH being controlled in the system could be explained by the electro-migration of the ion species in the solution through the ion exchange membrane under a cell potential difference between anode and cathode and its consequently-occurring non-charge equilibriums and electrolytic water- split reactions in the anodic and cathodic chambers.

  • PDF

Effect of Electrode Process Variables in case of Decomposition of $NO_x$ by SPCP (연면방전에 의한 질소산화물의 분해시 전극 공정변수에 대한 영향)

  • 안형환;강현춘
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.543-563
    • /
    • 1999
  • For hazardous air pollutants(HAP) such as NO and $NO_2$ decomposition efficiency, power consumption, and applied voltage were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of HAP with various electric frequencies(5~50 kHz), flow rates(100~1,000 mL/min) initial concentrations(100~1,000 ppm), electrode materials(W, Cu, Al), electrode thickness(1, 2, 3 mm) and number of electrode windings(7, 9, 11) were measured. Experimental results showed that for the frequency of 10 kHz, the highest decomposition efficiency of 94.3% for NO and 84.7% for $NO_2$ were observed at the poser consumptions of 19.8 and 29W respectively and that decomposition efficiency decreased with increasing frequency above 20 kHz. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3mm in this experiment. As the electrode material, decomposition efficiency was in order : tungsten(W), copper(Cu), aluminum(Al).

  • PDF

A Charge Pump Circuit in a Phase Locked Loop for a CMOS X-Ray Detector (CMOS X-Ray 검출기를 위한 위상 고정 루프의 전하 펌프 회로)

  • Hwang, Jun-Sub;Lee, Yong-Man;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.359-369
    • /
    • 2020
  • In this paper, we proposed a charge pump (CP) circuit that has a wide operating range while reducing the current mismatch for the PLL that generates the main clock of the CMOS X-Ray detector. The operating range and current mismatch of the CP circuit are determined by the characteristics of the current source circuit for the CP circuit. The proposed CP circuit is implemented with a wide operating current mirror bias circuit to secure a wide operating range and a cascode structure with a large output resistance to reduce current mismatch. The proposed wide operating range cascode CP circuit was fabricated as a chip using a 350nm CMOS process, and current matching characteristics were measured using a source measurement unit. At this time, the power supply voltage was 3.3 V and the CP circuit current ICP = 100 ㎂. The operating range of the proposed CP circuit is △VO_Swing=2.7V, and the maximum current mismatch is 5.15 % and the maximum current deviation is 2.64 %. The proposed CP circuit has low current mismatch characteristics and can cope with a wide frequency range, so it can be applied to systems requiring various clock speed.

Operational Properties and Microbial Inactivation Performance of Dielectric Barrier Discharge Plasma Treatment System (유전체장벽방전 플라즈마 장치의 조작특성과 살균력)

  • Mok, Chulkyoon;Lee, Taehoon
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.398-403
    • /
    • 2011
  • A dielectric barrier discharge plasma (DBDP) treatment system was fabricated and the optimum operating conditions for the plasma generation were determined in order to explore the potential of cold plasma as a non-thermal proessing technology. The microbial inactivation performance of the system was also evaluated against Staphyloocus aureus. The system consisted of power supply, transformer, electrode assembly and sample treatment plate. The input power was 220 V single phase AC and amplified to 10.0-50.0 kV on a transformer. A pulsed sine wave of frequency 10.0-50.0 kHz was introduced to the electrode embedded in ceramic as a dielectric barrier material in order to generate plasma at atmospheric pressure. Higher currents and consequently greater power were required for the plasma generation as the frequencies increased. A homogeneous and stable plasma was generated at currents of 1.0-2.0, and frequencies of 32.0-35.3 kHz. The optimum electrode-gaps for the plasma generation were 1.85 mm without loaded samples. More power was consumed as the electrode-gaps increased. The practically optimum electrode- gap was, however, 2.65 mm when samples were treated on slide-glasses for microbial inactivation. The maximum temperature increase after 10 min treatment was less than 20$^{\circ}C$, indicating no microbial inactivation effect by heat and thereby insuring a non-thermal method. The DBDP inactivation effect against Staphyloocus aureus increased linearly with treatment time up to 5 min, but plateaued afterward. More than 5 log reduction was achieved by 10 min treatment at 1.25 A.

Development of Multi-channel Detector of X-ray Backscatter Imaging (후방산란 엑스선 영상획득을 위한 다채널 검출기 개발)

  • Lee, Jeonghee;Park, Jongwon;Choi, Yungchul;Lim, Chang Hwy;Lee, Sangheon;Park, Jaeheung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.245-247
    • /
    • 2022
  • Backscattered x-ray imaging is a technology capable of acquiring an image inside an irradiated object by measuring X-rays scattered from an object. For image acquisition, the system must include an X-ray generator and a detection system for measuring scattered x-rays. The imaging device must acquire a real-time signal at sampling intervals for x-rays generated by passing through a high-speed rotating collimator, and for this purpose, a high-speed signal acquisition device is required. We developed a high-speed multi-channel signal acquisition device for converting and transmitting signals generated by the sensor unit composed of a large-area plastic scintillator and a photomultiplier tube. The developed detector is a system capable of acquiring signals at intervals of at least 15u seconds and converting and transmitting signals of up to 6 channels. And a system includes remote control functions such as high voltage, signal gain, and low level discrimination for individual calibration of each sensor. Currently, we are conducting an application test for image acquisition under various conditions.

  • PDF

The development of the Ionizer using clean room (청정환경용 정전기 제거장치 개발)

  • Jeong, Jong-Hyeog;Woo, Dong Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.603-608
    • /
    • 2018
  • Although the voltage-applied discharge method is most widely used in the semiconductor and display industries, periodic management costs are incurred because the method causes defects due to the absorption of ambient fine dust and causes emitter tip contamination due to the discharge. The emitter tip contamination problem is caused by the accumulation of fine particles in ambient air due to the corona discharge of the ionizer. Fuzzy ball generation accelerates the wear of the emitter tip and deteriorates the performance of the ionizer. Although a mechanical cleaning method using a manual brush or an automatic brush is effective for contaminant removal, it requires management of additional mechanical parts by the user. In some cases, contaminants accumulated in the emitter may be transferred to the wafer or product. In order to solve this problem, we developed an ionizer for a clean environment that can remove the pencil-type emitter tip and directly ionize the surrounding gas molecules using the tungsten wire located inside the ion tank. As a result of testing and certification by the Korea Institute of Machinery and Materials, the average concentration was $0.7572particles/ft^3$, the decay time was less than two seconds, and the ion valance was 7.6 V, which is satisfactory.