• Title/Summary/Keyword: 전산화 단층 촬영

Search Result 1,092, Processing Time 0.032 seconds

A Clinical Study of Pulmonary Hamartoma -Analysis of 41 Reported Cases in Korea Including 13 Cases in Severance Hospitol- (폐과오종에 대한 임상적 고찰 -국내 문헌 보고 41예를 포함한 세브란스 병원 13예에 대한 분석-)

  • Kim, Sung-Eun;Lee, Hong-Lyeol;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Kim, Sung-Kyu;Lee, Won-Young;Choe, Kyu-Ok;Chung, Kyung-Young;Shin, Dong-Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.565-574
    • /
    • 1993
  • Background: Pulmonary hamartomas are benign tumors that occur in the parenchyma or in the bronchi. They present as a solitary pulmonary nodule(SPN) or as a cause of bronchial obstruction. The incidence, once minimal, is increasing in Korea. To get clinical spectrum about the tumor, we analyzed all the reported cases in Korea since 1964. Methods: We reviewed the clinical, radiological and pathological findings of 13 patients of intrapulmonary or endobronchial hamartomas in Severance Hospital and of 38 reported cases in Korea published in literatures from 1964 to 1992 retrospectively. Results: Including 17 endobronchial hamartomas, 54 cases were studied. There were 25 men and 29 women, with a mean age of 47.2 years; 45.3 years in endobronchial type and 51.3 years in parenchymal type. Pulmonary symptoms were present in 8 patients (22%) of intrapulmonary type and in all patients of endobronchial type: cough (65%), dyspnea (53%), sputum (35%), fever (29%) in order. On chest X-rays, atelectasis was seen in 10 patients (59%) in endobronchial type; but SPN was noted in 36 patients (97%) of intrapulmonary type. Calcification was present in 7 intapulmonary hamartomas (23%); but is in 2 endobronchial hamartomas (12%). The diagnostic yield was 6 out of 14(43%) in endobronchial ones; 4 out of 7(57%) in intrapulmonary ones. Fifty patients underwent operations as follows: lobectomy (28), enucleation (8), resection (8), bilobectomy (4), pneumonectomy (2). The hamartomas were 1.2 times more common in the right lung; mean transverse diameter at the time of operation was 2.3 cm in endobronchial type, 3.8 cm in intrapulmonary ones. Chondroid components were present in 11(65%) of 17 endobronehial ones but in 30(91%) of 33 intrapulmonary hamartomas. No malignant changes were seen perioperative period and up to early 1993. Conclusion: The younger age in endobronchial hamartomas, the preponderance of the female sex and the more incidence in the right lung, and the diagnostic choice of lobectomies were different from the studies of the Western countries.

  • PDF

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices: Dental X-ray Equipment (치과용엑스선장치의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Lee, Jun-Ho;Park, Chang-Won
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.651-660
    • /
    • 2016
  • Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

Clinical and Radiographic Characteristics of 12 Patients with Mycobacterium abscessus Pulmonary Disease (Mycobacterium abscessus 폐질환 환자 12명의 임상적, 방사선학적 특징)

  • Koh, Won-Jung;Kwon, O Jung;Kang, Eun Hae;Jeon, Ik Soo;Pyun, Yu Jang;Ham, Hyoung Suk;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Han, Daehee;Kim, Tae Sung;Lee, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.1
    • /
    • pp.45-56
    • /
    • 2003
  • Background : Mycobacterium abscessus is the most common respiratory pathogen in rapidly growing mycobacteria and is resistant to all of the first-line antituberculosis drugs. This report describes the clinical and radiographic characteristics in patients with pulmonary disease caused by M. abscessus. Materials and Methods : Twelve patients with pulmonary disease caused by M. abscessus who fulfilled the 1997 American Thoracic Society diagnostic criteria for a nontuberculous mycobacterial pulmonary infection were observed over a five-and-a-half year period. The clinical characteristics and chest radiographic findings were analyzed, retrospectively. Results : The patients were predominantly female(11/12, 92%) and nonsmokers(12/12, 100%). Coughing (10/12, 83%), sputum(10/12, 83%) and hemoptysis(10/12, 83%) were the common symptoms and they had prolonged periods from the onset of symptoms to the diagnosis of their disease(median 6.5 years). Eleven (92%) patients had a previous history of being treated for pulmonary tuberculosis. The sputum specimens were acid-fast bacilli smear-positive in all patients. All patients were administered antituberculosis drugs. Six (50%) patients were treated with second-line antituberculosis drugs on account of persistent smear-positive sputum specimens. The chest radiographs showed that reticulonodular opacities(11/12, 92%) were the most common pattern of abnormality, followed by cavitary lesions(5/12, 42%). The computed tomography findings suggested bronchiolitis from the centrilobular nodules with a tree-in-bud appearances(9/10, 90%) and bronchiectasis (9/10, 90%) were the most common, followed by well-defined nodules smaller than 10-mm in diameter(7/10, 70%). Conclusions : M. abscessus pulmonary disease should be recognized as a cause of chronic mycobacterial lung disease, and respiratory isolates should be assessed carefully.

The Radiation Therapy for Spinal Cord Compression in Hematologic Malignancy (혈암에서 발생한 척추압박증상의 방사선 치료)

  • Kim In Ah;Choi Ihl Bohng;Chung Su Mi;Kang Ki Mun;Kay Chul Seong;Choi Byung Ok;Jang Ji Young;Shinn Kyung Sub;Kim Chun Choo
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.393-399
    • /
    • 1994
  • Spinal cord compression, an oncologic emergency, is a rare complication of hematologic malignancy Our experience was obtained with a series 32 Patients following retrospective analysis for assessing the role of radiation therapy and identifying the prognostic factors affecting on treatment outcome. Diagnosis was usually made by means of radiologic study such as myelography or computerized tomography (CT) or magnetic resonance imaging (MRI) and neurologic examination. Five cases were diagnosed by subjective symptom only with high index of suspicion. In 31 cases, the treatment consisted in radiation therapy alone and the remained one patient had laminectomy before radiation therapy because of diagnostic doubts. Total treatment doses ranged from 800 cGy to 4000 cGy with median of 2000 cGy. Initially large fraction size more than 250 cGy were used in 13 patients with rapidly progressed neurologic deficit. The clinical parameters considered in evaluating the response to treatment were backache, motor-sensory performance and sphincter function. Half of all patients showed good response. Partial response and no response were noted in $37.5\%$ and $12.5\%$, respectively. Our results showed higher response rate than those of other solid tumor series. The degree of neurologic deficit at that time of diagnosis was the most important predictor of treatment outcome. The elapsed time from development of symptoms to start of treatment was significantly affected on the outcome. But histology of primary tumor total dose and use of initial large fraction size were not significantly affect on the outcome. These results confirmed the value of early diagnosis and treatment especially in radiosensitive hematologic malignancy.

  • PDF

Effectiveness of MDCT for the Followup of CABG Patients with LIMA to LAD and Saphenous Veins to Others (좌내흉동맥과 복재정맥편을 사용한 관상동맥우회로술 환자에서의 추적조사에서 MDCT의 유용성)

  • Kang Joon Kyu;Kim Hyung Tai;Park In Duk;Chung Young Mi;Lee Cheol Joo
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.410-414
    • /
    • 2005
  • There are several options for choosing a graft in CABG, we routinely chose LIMA for LAD and great saphenous vein for other target vessels. To evaluate the posoperative graft patency, we have studied the results using a 16 slices multi-detector computed tomography. Material and Method: From 1995 to 2003, 80 CABG patients who did not complain any event of MACE have been examined by 16-MDCT, mostly in an out patient clinic. Result: There were 61 men and 19 women. MDCT was used as early as 7 days to 9 years post-operatively with a median follow-up period of 6.5 years, and mean follow-up peiod of $31.5\pm25.4$ months. Mean age was $58.4\pm12.6$ years old in men and $61.5\pm17.2$ years old in women. 72180 patients received LIMA to LAD, and all other patients received vein grafts for bypass. The target vessel of vein grafts were 8 in LAD, 47 in RCA, 60 in diagonals, and 61 in obtuse marginals. Among them 42 sequential anastomoses were performed. The mean graft number was $3.1\pm1.8$ grafts. 5 year graft patency rate of each grafts was as followings; $93.1\%$ in LIMA to LAD, $94.9\%$ in vein to diagonals, $92.1\%$ in vein to obtuse marginals, and $79.2\%$ in vein to RCA. Sequential grafting showed better graft patency than the isolated grafting $(95.2\%\;vs\;78.7\~95.0\%)$. Conclusion: In this study, CABG with LIMA and saphenous veins showed satisfactory longterm results. 16-MDCT provided good images for follow-up study after CABG. Additionally, as radiologic tools (64-MDCT, MRI) improve more in the future, they can be used for diagnosing preoperative anatomical coronary disease as well as cardiac functions.

Giant Coronary Artery Aneurysm Presenting as a Calcified Mediastinal Mass a, Coronary Artery Fistula - A case report - (종격동 종양으로 오인된 거대관상동맥류와 관상동맥루 - 치험 1례 -)

  • Yoon, You-Sang;Lee, Cheol-Joo;Choi, Ho;Kang, Jun-Kyu;Choi, Jin-Wook;Kim, Hyung-Tae
    • Journal of Chest Surgery
    • /
    • v.34 no.10
    • /
    • pp.787-791
    • /
    • 2001
  • Coronary artery aneurysm is a rare disorder. It is defined as abnormal dilatation of coronary artery with diameter exceeding 1.5 times the adjacent normal segments. The incidence of coronary aneurysm is 2.6% in Caucasians and 0.25% in Asians. Over half of the former were associated with atherosclerotic coronary artery disease. However, 70 percents of the latter were nonobstructive coronary artery aneurysms. Coronary artery fistula is a rare disorder. It has been identified in only 0.2% of routine cardiac angiographic studies conducted over a 10-year period. The clinical spectrums are various, asymtomatic, asymptomatic murmur, dyspnea on exertion, fatigue, and congestive heart failure. The right coronary artery (56%) and left coronary artery(36%) are mainly involved in the origin site of congenital coronary artery fistula. The draining site of fistula are right ventricle(39%), right atrium(33%), and pulmonary artery(20%) and so on. This 54 years-old woman had intermittent chest tightness and an abnormal mediastinal shadow on chest roentgenogram and chest C-T examination, which was diagnosed as a mediastinal mass such as teratoma. We performed the operation under left anterolateral thoracotomy for mass excision. However, we knew the mass had the pulsating arterial blood flow through a fine needle puncture of the mass and that it was attached to the left ventricle. We believed the excision of mass on beating heart would be very dangerous. Therefore, we closed the wound without excising the mass. After several days, we performed an echocardiography and coronary angiography, We knew it was cardiac tumor. Incidentally, the patient had a tortuous coronary fistula from the right coronary artery to pulmonary trunk. Using cardiopulmonary bypass with moderate systemic hypothermia, the mass was resected and the fistula was clipped with surgical clips. Pathology of the specimen was a giant coronary arterial aneurysm.

  • PDF

Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT (간의 단일선원 Twin Beam과 이중선원 이중에너지 전산화단층촬영의 비조영증강 영상과 가상 비조영증강 영상의 비교 연구)

  • Jeong Sub Lee;Guk Myung Choi;Bong Soo Kim;Su Yeon Ko;Kyung Ryeol Lee;Jeong Jae Kim;Doo Ri Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.170-184
    • /
    • 2023
  • Purpose To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.